Application Notes for Line Testing with ET 91 To learn more click on note! Single Sided Measurements END to END Measurements LCL Balance Impedance Return.

Slides:



Advertisements
Similar presentations
Trouble Shooting with ELQ 30 CROSSTALK BRIDGED TAPS INTERRUPTION UNBALANCE Typical Cable Problems ELEKTR NIKA To learn more click on the selected topic!
Advertisements

1 / 13 Fourier, bandwidth, filter. 2 / 13 The important roles of Fourier series and Fourier transforms: –To analysis and synthesis signals in frequency.
Automatic xDSL Test Sequences of ELQ 30A
Application Notes for Frequency Division Multiplex System Testing with ET 91 To learn more click on note! Basic, Super & Master Group Voice Frequency Noise.
BE-2110i VF/WIDEBAND TRANSMISSION TEST SET OPERATING OVERVIEW Slide 1 of 9.
ELEKTR NIKA To learn more click on the selected topic! Manual End to End Measuring Modes of ELQ 30A ► ► ► ► ► ► Loss Measurement with MTTS Group Delay.
Rohde & Schwarz Precision Power Measurement
Automatic Single Sided Test Sequence of ELQ 30A To learn more click on the selected topic! ELQ 30A provides single sided test sequences to estimate the.
FREQUENCY CONTROL MODES OF ET 91 To learn more click on note! END to END Loss Measurement Group Delay Distortion Measurement Frequency Tracking with Sweep.
PH4705 ET4305 Interface Standards A number of standard digital data interfaces are used in measurement systems to connect instruments and computers for.
Pipeline Current Mapper PCM+
Spectrum analyser basics Spectrum analyser basics 1.
Chapter 8. Impact of Noise Husheng Li The University of Tennessee.
FREQUENCY CONTROL MODES OF ET 92 To learn more click on note! END to END Loss Measurement Group Delay Distortion Measurement Frequency Tracking with Sweep.
HIAPER Cloud Radar Transceiver Exciter Receiver Oscillators High-Powered Amplifier Calibration Exciter Receiver Oscillators High-Powered Amplifier Calibration.
airQrate line of calibrators
Handheld Spectrum Analyzer R&S FSH
RF Equipment AFFORDABLE, SIMPLE, RELIABLE.. Compact and Reliable All of our equipment is packaged in sturdy powder- coated aluminum cases just a few inches.
Spectrum Analyzer Basics Copyright 2000 Agenda Overview: What is spectrum analysis? What measurements do we make? Theory of Operation: Spectrum analyzer.
Spectrum Analyzer Basics Copyright 2000 Agenda Overview: What is spectrum analysis? What measurements do we make? Theory of Operation: Spectrum analyzer.
NESCOT CATC1 Cable Testing CCNA 1 v3 – Module 4. NESCOT CATC2 Waves 1. The _________ of the waves is the amount of time between each wave, measured in.
Genuine random number generator demo software explanation What happens in this demo LeTech Co.,ltd.
Single Ended Measuring Modes of ELQ 30A To learn more click on the selected topic! ELEKTR NIKA Receiving Modes Impulse Noise Measurement Spectrum Analyzer.
SCAD 508 Strain Measurement System Click Here To Download Complete Information On SCAD Products EXCITATION VOLTAGESelectable from 0.5VDC to 10 VDC in steps.
Lab Group L2Bx EECE 380 – Electrical Engineering Design Studio (Spring 2014) 1 Spectrum Analyzer Michael Halpenny-Mason, Presenter 2, Presenter 3, Presenter.
Doppler Ultrasound Dr Mohamed El Safwany, MD.. Introduction The Doppler Effect refers to the change in frequency that results when either the detector/observer.
SPECTRUM ANALYZER 9 kHz GHz
Long Time Spectrogram Measurement with ET 91 The results are displayed on a 3 dimension picture ■ The time is on the vertical axis ■ The frequency is on.
WEATHER SIGNALS Chapter 4 (Focus is on weather signals or echoes from radar resolution volumes filled with countless discrete scatterers---rain, insects,
RADITEK inc RADITEK-RFTS-M1-L21WORLD HQ: 1702L Meridian Ave. Suite 127, San Jose, Ca 95125, U.S.A. Tel: (408) FAX: (408) WEB:
Automatic Voice Frequency Test Sequences of ELQ 30A To learn more click on the selected topic! The Automatic Master-Slave Measuring mode is intended for.
Single Ended Line Test with Upgraded ECFL 30
AUDIOMETRY An Audiometer is a machine, which is used to determine the hearing loss in an individual.
XDSL Line Tester Modem EX 30M ELEKTR NIKA EX 30M is a handheld, cost-effective test set to check DSL services and the copper cable capability. It is a.
PLC Testing with ET 91 Level Test Set To learn more click on note! Pilot Level Measurement on RF Test Point Measurements in Special Tracking Mode Pilot.
Frequency Division Multiplex System Testing with ET 92 To learn more click on note! Basic, Super & Master Group Voice Frequency Noise END to END Measurements.
Downstream Power Back Off (DPBO)
Manual Measuring Modes of ELA 10 To learn more click on the selected topic! Level, Loss Noise, Spectrum Line Parameter Optional Measurements Transmitting.
FREQUENCY CONTROL MODES OF ET 91 To learn more click on note! END to END Loss Measurement Group Delay Distortion Measurement Conventional Setting Modes.
ANALOG SPECTRUM ANALYSIS. TOPICS Bank-of-filters spectrum analyzer Sequential spectrum analyzer –Variable tuning filter spectrum analyzer –Superheterodyne.
Fletcher’s band-widening experiment (1940) Present a pure tone in the presence of a broadband noise. Present a pure tone in the presence of a broadband.
By.  The main aim of this project is to get information about the condition of the baby, which is in ICU through blue tooth medium.  In earlier days,
By. Jadhav Avinash J Roll no - 2K13E11. Reference: Hewlett Packard Agilent Technology Wikipedia GwINSTEK.
Module 8 Tutorial  An 8086 system is used for controlling the speed of a motor. The motor can operate at 5 different speeds (1- 5).  The speed.
Piero Belforte, HDT, July 2000: MERITA Methodology to Evaluate Radiation in Information Technology Application, methodologies and software solutions by Carla Giachino,
Single Ended Measuring Modes of ELQ 30A+
Manual End to End Measuring Modes of ELQ 30A+
Automatic xDSL Test Sequences of ELQ 30A+
Trouble Shooting with ELQ 35
Discussion today Using Lumerical INTERCONNECT we will simulate a full 50Gbps (25Gbps X 2) 2-channel WDM optical link. Today we will look at the following:
Single Ended Line Test with Upgraded ECFL 30
Telephone & Exchange Tester ETET 30
xDSL Line Tester Modem EX 30M
Telephone & Exchange Tester ETET 30
Trouble Shooting with ELQ 30
Automatic Voice Frequency Test Sequences of ELQ 30A+
Downstream Power Back Off (DPBO)
xDSL Line Tester Modem EX 30M
Downstream Power Back Off (DPBO)
Long Time Spectrogram Measurement with ET 92
Single Ended Line Test with Upgraded ECFL 30
xDSL Line Tester Modem EX 30M
Automatic Single Sided Test Sequence of ELQ 30A+
10.5 Fourier Transform NMR Instrumentation
Manual Measuring Modes of ELA 10
Manual Measuring Modes of ELA 10
Automatic Test Sequences in Master-Slave Mode
Automatic Test Sequences in Master-Slave Mode
Trouble Shooting with ELQ 30A+
Presentation transcript:

Application Notes for Line Testing with ET 91 To learn more click on note! Single Sided Measurements END to END Measurements LCL Balance Impedance Return Loss Near End Crosstalk Spectrum Analyser Frequency Response with MTTS Automatic Master Slave Test Micro Interruption Analysis ELEKTR NIKA

LCL Balance Measurement with ET 91 Two balance measuring modes are provided: ■ Measurement with one single frequency ■ Measurement with one single frequency ■ Measurement in sweep mode ■ Measurement in sweep mode ET 91 performs LCL measurement using the test circuit described in ITU-T Rec. 0.9 Test results are available in graphic or numeric formats. Selectable ranges ELEKTR NIKA

Impedance Measurement with ET 91 ET 91 provides impedance measurement for balanced and coaxial test objects in fix frequency or sweep modes without any external adapter. Test results are available in graphic or numeric formats. Selectable ranges ELEKTR NIKA

Return Loss Measurement with ET 91 ET 91 provides return loss measurement for balanced and coaxial test objects in fix frequency or sweep modes without any external adapter. Test results are available in graphic or numeric formats. Selectable ranges ELEKTR NIKA

Near End Crosstalk measurement with ET 91 ET 91 provides Near End Crosstalk measurement for balanced and coaxial test objects by transmitting on socket L2 and receiving on L1. Fix frequency or sweep modes are available Test results are available in graphic or numeric formats. Selectable ranges ELEKTR NIKA

Spectrum Analyzer Measurement with ET 91 Noise Level MeasurementPower Spectral Density (PSD) Measurement ET 91 provides sophisticated spectrum analyser measurements with extremely large dynamic range and high resolution. Display range: down to -140 dBm/Hz Evaluation: NORM, PEAK, AVG, SAWG Test results are available in graphic or numeric formats. Selectable ranges ELEKTR NIKA

Quick Frequency Response Test of ET 91 with Multi Tone Test Signal MTTS METHOD : ■ The transmitter generates 35 test tones ■ The receiver measures the 35 test tones simultaneously ADVANTAGES: ■ No synchronisation is necessary between the two instruments ■ The measuring time is shorter than that of other methods Selectable ranges ELEKTR NIKA

Automatic Line Test in Master Slave Mode of ET 91 ▼ Click here to see detailed results ELEKTR NIKA

Detailed Test Results of Automatic Master Slave Line Measurement All the test results are available also in numeric form and they can be transferred to PC via USB interface. ELEKTR NIKA

Micro Interruption Measurement with ET 91 ▼ Click here to see detailed results in numeric and graphic forms An interruption is detected when the level of test tone drops below a designated threshold for more than 0,6 ms. The detected interruptions are included into five categories by duration ELEKTR NIKA

Detailed Results of Micro Interruption Measurement All the test results are available also in numeric form and they can be transferred to PC via USB interface. ELEKTR NIKA

THANK YOU FOR YOUR ATTENTION !