Cisco Unified Computing System Nuts & Bolts

Slides:



Advertisements
Similar presentations
Virtual Trunk Protocol
Advertisements

Chapter 1: Introduction to Scaling Networks
Network Devices Repeaters, hubs, bridges, switches, routers, NICs.
LAN Segmentation Virtual LAN (VLAN).
© 2006 Cisco Systems, Inc. All rights reserved. ICND v2.3—2-1 Extending Switched Networks with Virtual LANs Introducing VLAN Operations.
UTC-N Overview of Campus Networks Design.
© 2011 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 1 Unified Computing System The Platform of Innovation Justin Bigger Solution.
Virtual LANs.
© 2006 Cisco Systems, Inc. All rights reserved.Presentation_ID 1 Configuring Cisco Nexus 5000 Switches in NPV Mode Module 9.
Cisco UCS Mini Martin Hegarty| Product Manager | Comstor
Switching & Operations. Address learning Forward/filter decision Loop avoidance Three Switch Functions.
Brocade VDX 6746 switch module for Hitachi Cb500
Switching Topic 4 Inter-VLAN routing. Agenda Routing process Routing VLANs – Traditional model – Router-on-a-stick – Multilayer switches EtherChannel.
Cisco 3 - Switch Perrine. J Page 15/8/2015 Chapter 8 What happens to the member ports of a VLAN when the VLAN is deleted? 1.They become inactive. 2.They.
VLANs Virtual LANs CIS 278.
Multi-Layer Switching Layers 1, 2, and 3. Cisco Hierarchical Model Access Layer –Workgroup –Access layer aggregation and L3/L4 services Distribution Layer.
© 2008 Cisco Systems, Inc. All rights reserved.Cisco ConfidentialPresentation_ID 1 Chapter 5: Inter-VLAN Routing Routing & Switching.
5.3 Ethernet connectivity and options. Unit objectives After completing this unit, you should be able to: List the BladeCenter components required for.
1 Version 3 Module 8 Ethernet Switching. 2 Version 3 Ethernet Switching Ethernet is a shared media –One node can transmit data at a time More nodes increases.
(part 3).  Switches, also known as switching hubs, have become an increasingly important part of our networking today, because when working with hubs,
LOGO Local Area Network (LAN) Layer 2 Switching and Virtual LANs (VLANs) Local Area Network (LAN) Layer 2 Switching and Virtual LANs (VLANs) Chapter 6.
Layer 2 Switch  Layer 2 Switching is hardware based.  Uses the host's Media Access Control (MAC) address.  Uses Application Specific Integrated Circuits.
Virtual LANs. VLAN introduction VLANs logically segment switched networks based on the functions, project teams, or applications of the organization regardless.
Connecting LANs, Backbone Networks, and Virtual LANs
We will be covering VLANs this week. In addition we will do a practical involving setting up a router and how to create a VLAN.
Module 12 MXL DCB <Place supporting graphic here>
InterVLAN Routing Design and Implementation. What Routers Do Intelligent, dynamic routing protocols for packet transport Packet filtering capabilities.
1 © 2003, Cisco Systems, Inc. All rights reserved. CCNA 3 v3.0 Module 7 Spanning-Tree Protocol Cisco Networking Academy.
Repeaters and Hubs Repeaters: simplest type of connectivity devices that regenerate a digital signal Operate in Physical layer Cannot improve or correct.
VLAN V irtual L ocal A rea N etwork VLAN Network performance is a key factor in the productivity of an organization. One of the technologies used to.
Cisco 3 - LAN Perrine. J Page 110/20/2015 Chapter 8 VLAN VLAN: is a logical grouping grouped by: function department application VLAN configuration is.
LOGO Local Area Network (LAN) Layer 2 Switching and Virtual LANs (VLANs) Local Area Network (LAN) Layer 2 Switching and Virtual LANs (VLANs) Chapter 6.
© 2008 Cisco Systems, Inc. All rights reserved.Cisco ConfidentialPresentation_ID 1 Chapter 1: Introduction to Scaling Networks Scaling Networks.
Configuring Cisco Switches Chapter 13 powered by DJ 1.
S7C5 – Spanning Tree Protocol And other topics. Switch Port Aggregation Bundling –Combining 2 to 8 links of FE (Fast Ethernet) or GE (Gigabit) Full duplex.
Sem1 - Module 8 Ethernet Switching. Shared media environments Shared media environment: –Occurs when multiple hosts have access to the same medium. –For.
1 © 2003, Cisco Systems, Inc. All rights reserved. CCNA 3 v3.0 Module 9 Virtual Trunking Protocol.
Cisco S3C3 Virtual LANS. Why VLANs? You can define groupings of workstations even if separated by switches and on different LAN segments –They are one.
1 © 2003, Cisco Systems, Inc. All rights reserved. CCNA 3 v3.0 Module 8 Virtual LANs Cisco Networking Academy.
Chapter 3 - VLANs. VLANs Logical grouping of devices or users Configuration done at switch via software Not standardized – proprietary software from vendor.
STORE AND FORWARD & CUT THROUGH FORWARD Switches can use different forwarding techniques— two of these are store-and-forward switching and cut-through.
1 © 2003, Cisco Systems, Inc. All rights reserved. CCNA 3 v3.0 Module 7 Spanning Tree Protocol.
Finish up from Monday:. Today’s Agenda…  Day 1 Switching Technologies (Chapter 2 Sybex)Switching Technologies (Chapter 2 Sybex) VIRTUAL LAN’s [VLAN’S]
1 Version 3.0 Module 7 Spanning Tree Protocol. 2 Version 3.0 Redundancy Redundancy in a network is needed in case there is loss of connectivity in one.
Chapter 4 Version 1 Virtual LANs. Introduction By default, switches forward broadcasts, this means that all segments connected to a switch are in one.
BZUPAGES.COM Introduction to Cisco Devices Interfaces and modules –LAN interfaces (Fast Ethernet, Gigabit Ethernet) –WAN interfaces(Basic Rate Interface.
Cisco Confidential © 2010 Cisco and/or its affiliates. All rights reserved. 1 Multicasting within UCS Qiese Dides.
Chapter-5 STP. Introduction Examine a redundant design In a hierarchical design, redundancy is achieved at the distribution and core layers through additional.
Pass Cisco CCIE Data Center Written exam in just 24 HOURS! 100% REAL EXAM QUESTIONS ANSWERS Cisco CCIE Data Center Written Buy Complete.
Cisco Confidential 1 © 2010 Cisco and/or its affiliates. All rights reserved. Fiber Channel over Ethernet Marco Voi – Cisco Systems – Workshop CCR INFN.
1 Implementing a Virtualized Dynamic Data Center Solution Jim Sweeney, Principal Solutions Architect, GTSI.
Connectors, Repeaters, Hubs, Bridges, Switches, Routers, NIC’s
Cisco UCS.
Implementing Cisco Data Center Unified Computing
Instructor Materials Chapter 1: LAN Design
SECURITY ZONES.
© 2002, Cisco Systems, Inc. All rights reserved.
Chapter 4 Data Link Layer Switching
100% REAL EXAM QUESTIONS ANSWERS
Braindumps4IT Braindumps Ream Exam Questions Answers
Chapter 5: Inter-VLAN Routing
Configuring EtherChannels and Switch Troubleshooting
Virtual LANs.
If you Want pass Your Exam In first Attempt practice-questions.html.
If You are really Worried About your Cisco exam dumps practice-questions.html Introducing Cisco Data.
2018 Real Cisco Dumps IT-Dumps
Latest Free Exam Questions - Free Full Training
Module – 6 IP san and fcOe Module 6: IP SAN and FCoE 1
Connectors, Repeaters, Hubs, Bridges, Switches, Routers, NIC’s
Presentation transcript:

Cisco Unified Computing System Nuts & Bolts Sean Hicks General DataTech, L.P. Managing Principal - Compute & Storage

What the heck is a UCS? Cisco UCS is a next-generation compute platform designed to address the following concerns: Data Center Sprawl Points of Management Cabling Power & Cooling Virtualization Changing Admin Boundaries Resource Bottlenecks Software-based L2 Overhead Reliability & Scalability High Availability Minimal Effort Rapid Deployment Stateless Hardware

Fabric Interconnects – G1 Cisco UCS 6120XP 1 RU, Redundant Power, Front-to-Back Air Flow 20 x 10 Gbps Ethernet, L1, L2, Mgmt0, Mgmt1 (unused) & Console 1 Expansion Bay Cisco UCS 6140XP 2 RU, Redundant Power, Front-to-Back Air Flow 40 x 10 Gbps Ethernet, L1, L2, Mgmt0, Mgmt1 (unused) & Console 2 Expansion Bays Expansion Modules N10-E0080: 8 x 4 Gbps FC N10-E0060: 6 x 8 Gbps FC N10-E0440: 4 x 10 Gbps Ethernet + 4 x 4 Gbps FC N10-E0600: 6 x 10 Gbps Ethernet

Fabric Interconnects – G2 Cisco UCS 6248UP 1 RU, Redundant Power, Front-to-Back Air Flow 32 x Unified Fabric Ports, L1, L2, Mgmt0 & Console 1 Expansion Bay Cisco UCS 6296UP 2 RU, Redundant Power, Front-to-Back Air Flow 48 x Unified Fabric Ports, L1, L2, Mgmt0 & Console 3 Expansion Bays Expansion Modules UCS E16UP: 16 x Unified Fabric Ports

End-Host Virtualization In its default configuration (End-Host mode), a Fabric Interconnect appears to the network as a server with a bunch of NICs, much like a Hypervisor. It is not a true Ethernet switch! Does not participate in Spanning Tree elections. Allows for rapid L2 link establishment and multiple active uplinks. Does not learn northbound MAC addresses. Makes intelligent forwarding decisions based on learned (internal server) versus unlearned (external network) MAC addresses. Traversing frames are forwarded/dropped based on pinning traffic to interfaces. Déjà vu check, reverse path forwarding check, inter-uplink port blocking and bcast/mcast link election defeat the purpose of Spanning Tree between the FI and the northbound switch. Server-to-server in same VLAN is the only locally switched traffic. Ethernet Switch Visio Stencil Fabric Interconnect Visio Stencil You see, Kyle?! Totally different!!!

Historical Need For Spanning Tree Broadcast Broadcast frame enters Switch 1. Switch 1 learns Src MAC, floods to every port except the originator. Switches 2 and 3 do the same, creating a loop. Broadcast storm begins. Trogdor strikes again! And again, and again, and again…

Spanning Tree Behavior Broadcast Switches hold Spanning Tree election, Switch 1 blocks port to Switch 3. Broadcast frame enters Switch 1. Learns Src MAC then floods. Switch 2 does the same. No loop, but… Trogdor strikes again! Half of Switch 3’s cabled bandwidth is unused. Redundant link convergence is very slow.

EHV Bcast/Mcast Behavior Broadcast Bcast/Mcast LAN Uplink Broadcast frame enters Switch 1. Learns Src MAC and floods. Broadcast frame enters Switch 3. Learns Src MAC and floods. FI sees unlearned Bcast on Bcast/Mcast LAN Uplink, forwards to Server Ports. FI sees unlearned Bcast on any other LAN Uplink, drops the frame. All LAN Uplinks on FI are active and utilized for pinned MAC addresses. MAC’s dynamically and rapidly re-pin for LAN Uplink state change.

EHV Bcast/Mcast Behavior Broadcast Bcast/Mcast LAN Uplink Learned Bcast enters FI on Server Port. FI forwards out pinned LAN Uplink. Broadcast frame enters Switch 1. Switch 1 learns Src MAC and floods. Broadcast frame enters Switch 3. Switch 3 learns Src MAC and floods. If Bcast gets back to FI it will drop since Src isn’t pinned to that LAN Uplink. All LAN Uplinks on FI are still active and utilized for pinned MAC addresses. MAC’s still dynamically and rapidly re-pin for LAN Uplink state change.

N-Port Virtualization In its default configuration (NPV mode), a Fabric Interconnect is also not a true Fibre Channel switch! Does not have a Fibre Channel domain ID. Conserves FC domain ID’s, but unable to assign FCID’s to connected N-ports. Keeps SAN Uplinks from becoming E-ports. No ISL means no FSPF negotiation. Acts as a “N-port Proxy” for connected N-ports. Requires “N-Port ID Virtualization” (NPIV) be enabled on an upstream Fibre Channel switch. Do not confuse the two! A Cisco MDS or Nexus switch can be enabled for NPV mode, too, but this setting erases the config and reboots the switch. An additional FC switch is then needed farther upstream to be enabled for NPIV. Cisco MDS Switch Visio Stencil Fabric Interconnect Visio Stencil You see, Kyle?! Still different!!!

Historical Fibre Channel N-port F-port FLOGI FCID 0x010001 WWPNA Domain ID 0x01 Server with WWPNA needs an FCID so its HBA can begin forwarding FC frames. Sends FLOGI to FC switch with FC Domain ID 0x01. FC switch responds with an FCID built off its FC Domain ID. The server’s HBA is now logged into the fabric and can begin forwarding FC frames. The same process happens between the FC switch and the FC storage array. It is often likened to DHCP in IP networks. In traditional FC design, there are dual fabrics such as this one for path redundancy. Storage Array

Blade Server Considerations FLOGI FLOGI FLOGI FLOGI WTF?! LOL!!! WWPNA WWPNB Domain ID 0x01 WWPNC WWPND Servers need FCIDs so HBAs can begin forwarding FC frames. The problem is there is traditionally a 1:1 relationship between N-port and F-port. Storage Array

NPV/NPIV Behavior NPV NP-port NPIV FLOGI FCID 0x010001 FLOGI 0x010002 FDISC Domain ID 0x01 FCID 0x010002 Storage Array Only one FLOGI is received on the switchport for the FI’s WWPN. FI Looks like F-port to Blade’s N-port, but acts as an N-port Proxy. FLOGI received by FI from Blade, FI kicks off FDISC to switch. Switch issues FCID for the FDISC, FI forwards on to Blade.

IO Modules (Fabric Extenders) Cisco UCS 2104XP (G1) External: 4 x 10 Gbps Ethernet Internal: 8 x 10 Gbps Ethernet 1 x 10 Gbps to each blade slot 2:1 Oversubscription, Static Pinning Cisco UCS 2204XP (G2) Internal: 16 x 10 Gbps Ethernet 2 x 10 Gbps to each blade slot 2:1 Oversubscription, Static Pinning or Port Channel Cisco UCS 2208XP (G2) External: 8 x 10 Gbps Ethernet Internal: 32 x 10 Gbps Ethernet 4 x 10 Gbps to each blade slot 1:1 Oversubscription, Static Pinning or Port Channel

What is a Fabric Extender Extends the presence of the Fabric Interconnect into the blade server chassis. Works exactly like Nexus Fabric Extenders. In fact… C-series integration! Unable to make any L2 decisions on its own. Must rely on parent switch or FI. Looks exactly like line cards in a modular switch. Single point of management!

VIFs and VNTags Each upstream port is a FEX port (external ports on IOM). Each downstream port is a Virtual Interface or VIF (internal ports on IOM). VIFs are identified at the parent switch using VNTags (Virtual Networking Tags). A VNTag is sort of like a virtual cable inside an actual cable. vEth VNTag 1 FI Port VNTag 2 VNTag 3 vFC

Fibre Channel Over Ethernet Creates a virtual SAN fabric over physical LAN links. Encapsulates FC frames inside Ethernet frames. Ethertype is FCoE (0x8906) Uses Priority Flow Control (PFC) to match the lossless behavior of Fibre Channel. Uses Jumbo Frames. SCSI data cannot be fragmented. CoS is on by default in UCS. Requires FCoE VLAN ID’s. Cannot overlap with existing VLANs. FI requires VSANs to pin FC traffic to SAN Uplinks. Needs a VLAN ID to reference for each VSAN. Allows cabling consolidation between FI’s and chassis. Inherits SAN fabric separation, which is why each IOM is connected to only one FI. Fibre Channel Payload Maximum 2112 Bytes Ethernet Header FCoE Header FC Header CRC EOF FCS

UCS 5108 Blade Server Chassis 6 RU, Front-to-Back Air Flow 2 x IO Module Slots 8 x Half-width Blade Slots Maximum 8 Half-width Blades Maximum 4 Full-width Blades Can combine Half- and Full-width Blades 4 x 2500 Watt Power Supplies 2 Required for Full Population (Non-redundant) 3 for N+1 Redundancy 4 for Full Grid Redundancy Up to 20 per FI Cluster Up to 160 Half-width Blade Servers Current Supported Limit, Not Hard Limit “Rolled Steel”

UCS B-Series Blade Servers Sub-light Speed: UCS B22 M3 2 x Intel Xeon E5-2400 (16 Cores Max) 192 GB Maximum Half-width Light Speed: UCS B200 M3 2 x Intel Xeon E5-2600 (16 Cores Max) 768 GB Maximum Ridiculous Speed: UCS B230 M2 2 x Intel Xeon E7-2800 (20 Cores Max) 512 GB Maximum Ludicrous Speed: UCS B420 M3 4 x Intel Xeon E5-4600 (32 Cores Max) 1.5 TB Maximum Full-width Plaid: UCS B440 M2 4 x Intel Xeon E7-4800 (40 Cores Max) 1 TB Maximum

Stateless Hardware A Service Profile is a logical representation of a server. Contains unique identifiers (UUID, MACs & WWNs). Makes them portable! Also contains policies related to network and storage connectivity, management. Can be rapidly deployed from a Service Profile Template.

Virtual Interface Cards (VICs) M81KR “Palo” (G1) 2 x 10 Gbps, 1 to each IOM Maximum 128 Virtual Interfaces* Mezzanine Adaptor (PCIe x16) VIC 1240 (G2) 4 x 10 Gbps, 2 to each IOM Maximum 256 Virtual Interfaces* mLOM (M3 blades only) Expansion Module VIC 1280 (G2) 8 x 10 Gbps, 4 to each IOM Architectural limit. Real limit based on the number of server ports cabled between FI and IOM.

Single Root IO Virtualization SR-IOV allows a PCIe device to appear as multiple devices of the same type. Made possible by distinction between Physical Functions and Virtual Functions. Physical Functions (PF’s) can control the device and move data in or out of the device. Virtual Functions (VF’s) can only move data in or out of the device. Requires Hardware, Firmware and Software (OS) support to implement. Cisco VICs have the intelligence to handle all of it on board. Transparent to the OS (no support needed). Multiple adaptors for different CoS/QoS markings. Allows “Shadow NIC” capability (aka Fabric Failover). Allows for VM-FEX capability… Replaces Hypervisor soft-switch, off-loading L2 overhead to real, dedicated hardware. Returns control of the access layer switching environment to the network administrators. Does not break vMotion!

Cable Less, Scale Rapidly 2 Fabric Interconnects 1 Chassis, 8 Blades, 2 Cables 2 Chassis, 16 Blades, 4 Cables 3 Chassis, 24 Blades, 6 Cables 4 Chassis, 32 Blades, 8 Cables 5 Chassis, 40 Blades, 10 Cables 6 Chassis, 48 Blades, 12 Cables 13 Chassis, 104 Blades, 26 Cables 20 Chassis, 160 Blades, 40 Cables Assumes bandwidth requirement of 2 x 10 Gbps to each UCS 5108.

Single Point of Management The pair of Fabric Interconnects represents a single UCS Manager domain. Every connected physical blade server chassis is actually a module in a single logical blade server chassis. Every component in this larger, logical chassis is configured, operated and monitored via the pair of Fabric Interconnects across their Mgmt0 ports. Mgmt0 ports and Cluster IP address must be in the same broadcast domain.

High Availability The Fabric Interconnects negotiate high availability for the cluster IP address of the UCS Manager domain through a primary-subordinate election over their L1 and L2 ports (known as cluster links) and through the connected chassis (failsafe mechanism to prevent management split brain in the event of cluster links loss). The dual fabric, active-active design provides LAN and SAN connectivity to every blade in every chassis even if one of the Fabric Interconnects malfunctions. HA for UCS Manager is unavailable until the first connected chassis is acknowledged.

Questions & Answers Contact Information: shicks@gdt.com (214) 857-6281 http://www.linkedin.com/in/seanphicks