Automation and Drives s SIRIUS 1 s s Class 70/71 Enclosed Starters.

Slides:



Advertisements
Similar presentations
Automation and Drives s SIRIUS 1 s SIRIUS Soft Starts.
Advertisements

Chapter 6 NEMA Products Training Session
Automation and Drives s SIRIUS 1 s s SIKOSTART Soft Starts.
SIRIUS Motor Management
Automation and Drives SIRIUS SC Solidstate Switching DevicesA&D CD CC PM4, Jan. 21, Gliederungspunkt 10 Gliederungspunkt 1 Gliederungspunkt 2 Gliederungspunkt.
Variable Frequency Drives Bypass Options
Sequential Process Control
Brake System Fundamentals
Your universal enclosure. 159 LC  159 Cubic inches of space with a hinged lid  Made from all galvanized steel, powder coated white, with a rubber.
AC-SSC-1 Installation and operation manual
Programming Logic Controllers
RMM Systems, LLC By Sam Rietta RMM Systems, LLC is a manufacturer's representative firm focused on providing value added sales solutions by providing.
Sales Training Outline 2006 Klaus Tum Product Manager Motor Disconnect Switches 35 Royal Road Flemington, NJ
©2011, The McGraw-Hill Companies, Inc. Chapter 4.
 Salient characteristics / Approvals  Non-illuminated Switches  Illuminated Switches  Pilot Lights  Contact Elements Control & Signalling Devices.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
Contactor, Relays and Overloads
Engineer Training Electrical Cabinet (EC) TJ8300 / TJ8500 Electrical Cabinet (EC)
Application Types Variable Torque Constant Torque.
GO ORDNANCE !!! ORDNANCECORPS 1 Troubleshoot the DC Electrical Control System on the EPP III.
Lesson 15: Dc Motor Control Components and Diagrams
Chapter 8 Output Modules.
Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams
1. Presentation Overview  Solar Industry Overview  Intro into Solar Photovoltaics  Types of PV Systems  Solar Product Offering –Solar Combiner Boxes.
Sales Training Outline 2006 Laszlo Gyorgypal Product Manager Push Buttons 35 Royal Road Flemington, NJ
Two Phase Control. Depending on their design, soft starters control one, two or three phases. The CSX controls only two phases because this allows the.
Engineer Training UV Electrical Cabinet (16 and above) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 16 and above)
1 HVAC 214 Electricity For Oil Heat Fan Center Relays.
Chapter 3 Manual Starters.
Install IntelSteer Power Saver Device
Chapter 6 Control_relays.
Industrial Machine Control
1 FUNDAMENTOS DEL CONTROLADOR PROGRAMABLE. 2 ¿QUE ES UN CONTROLADOR PROGRAMABLE? PROGRAMMABLE CONTROLLER ENTRADAS A solid state device that controls output.
Ladder Diagram Symbols Flashcard Exercise Get Started.
Description of various components/sub-assemblies.
1 The problem : M3 too big (and too expensive) for 38A starters The solution : Introduction of a new size intermediate between M2 and M3 Features -Possibility.
Sprecher + Schuh has shipped stock components under the Platinum and Gold Shipment program for several years while the demands on our Custom Control.
Engineer Training UV Electrical Cabinet (1-15) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 1-15)
Why Maintenance Tasks are Important Produced by Joe Marchese.
CLIQ unit Integration. General view: -Schroff rack 19’’ 25U (500mm x 600mm x 1120mm). -2 fixed wheels +2 castor wheels with brake ⦰100mm. Capacitors Capacitors.
Suggestion on How to Use
1 © 2015 Eaton. All Rights Reserved.. Suggestion on How to Use Industry Trainers are encouraged to use this material in their sessions Download the presentation.
Symbols and Schematic Diagrams
© 2009 Eaton Corporation. All rights reserved. Industrial Control Division Overview Milwaukee, WI.
Switches and Over Current Protective Devices Class Instructor ALPHER E. DE VERA, uap.
Design of starters for AC motors C.K. PITHAWALA COLLAGE OF ENGINEERING & TECHNOLOGY Group no - 3 Name Enrolment no Chaudhari Darshan M Chaudhari.
BASIC ELECTRICITY AND MAGNETISM
Last updated: 6/28/2016www.alto-shaam.com Rotisserie Training Rotisserie.
Push Button Station and Relay
Copyright © 2009 Toshiba International Corporation. All rights reserved. Hx7+Pack Drive Severe Duty Adjustable Speed Drive Prepared By: ASD Marketing.
CGS Ground School Technical The Vigilant Electrical System © Crown Copyright 2012 No Part of this presentation may be reproduced without the permission.
Asahi/America Electric Actuators
Kenneth A. Stone Senior Automation Specialist UL508 Standards
Section 6: Air-Conditioning (Heating And Humidification)
Presented by SARAVANA KUMAR . M (EEE III Year) SBM CET
Understanding Olympian Generator Set Schematics
CH 5 – Electricity and Magnetism
Stainless Steel Water Well Casing.
Asahi/America Electric Actuators
Lesson 14: Introduction To Sequential Control
ET 438B Sequential Control and Data Acquisition
Electrical Quantities
HVAC Schematic Symbols
23.2 Applications of Circuits
Electric Potential Difference aka Voltage
Presentation transcript:

Automation and Drives s SIRIUS 1 s s Class 70/71 Enclosed Starters

Automation and Drives s SIRIUS 2 s s Class 70/71 Enclosed Starters Topics –Whats inside? –Difference between Class 70 and 71 –Enclosure Types –Starter options –Custom panels

Automation and Drives s SIRIUS 3 s s Class 70/71 Enclosed Starters Whats inside? –Soft Start Controller (34RW34) –Control Power Transformer –Motor Overload Protection –Terminal Blocks –Two Pilot Device holes (30mm) –Back Panel predrilled for options

Automation and Drives s SIRIUS 4 s s Class 70/71 Enclosed Starters Class 70 Starter –Non-Combination design >Customer supplies disconnect means –Available Enclosures >N1, N12, N3R, N4, N4X –Options include >Start/Stop, HOA, Pilot lights, & Relays –Custom Engineered Panels >Minimum Order Quantities

Automation and Drives s SIRIUS 5 s s Class 70/71 Enclosed Starters Class 70 Starter –NEMA 1 Enclosure >Vented Enclosure >Uses fans to circulate the air –NEMA 12/4 Enclosure >Enclosure is not vented >Uses a Bypass Contactor

Automation and Drives s SIRIUS 6 s s Class 70/71 Enclosed Starters Class 71 Starter –Combination design >Disconnect is supplied –MCP, Thermal-Mag (720A), Fusible –Available Enclosures >N1, N12, N3R, N4, N4X –Options include >Start/Stop, HOA, Pilot lights, & Relays –Custom Engineered Panels >Minimum Order Quantities

Automation and Drives s SIRIUS 7 s s Class 70/71 Enclosed Starters Class 71 Starter –NEMA 1 Enclosure >Vented Enclosure >Uses fans to circulate the air –NEMA 12/4 Enclosure >Enclosure is not vented >Uses a Bypass Contactor

Automation and Drives s SIRIUS 8 s s Class 70/71 Enclosed Starters NEMA 12 Enclosure –Bypass Contactor Required >Eliminates heat buildup >Up to Voltage output energizes Bypass Contactor >Contactor is horsepower rated allowing for ATL emergency start option without derating >Optional Run/Bypass Selector Switch available –Enclosure is painted steel >Dust tight and gasketed >Class 52 pilot devices used

Automation and Drives s SIRIUS 9 s s Class 70/71 Enclosed Starters NEMA 4 Enclosure –Bypass Contactor Required >Eliminates heat buildup >Up to Voltage output energizes Bypass Contactor >Contactor is horsepower rated allowing for ATL emergency start option without derating >Optional Run/Bypass Selector Switch available –Enclosure is painted steel >Water tight and gasketed >Class 52 pilot devices used

Automation and Drives s SIRIUS 10 SIRIUS s s Class 70/71 Enclosed Starters NEMA 4X Enclosure –Available for 36A – 248A Ratings –Bypass Contactor Required >Eliminates heat buildup >Up to Voltage output energizes Bypass Contactor >Contactor is horsepower rated allowing for ATL emergency start option without derating –Enclosure is Stainless Steel >Water tight and gasketed >Class 52 pilot devices used >Option for Non-Metallic 4X enclosure

Automation and Drives s SIRIUS 11 SIRIUS s s Class 70/71 Enclosed Starters Class 70/71 Starter Options –Pilot Devices >Start/Stop Push Buttons >Selector Switches >Control Relays & Time Relays >Meters (Ammeter, Voltmeter, ETM) –Contactors >Isolation Contactors >Reversing Contactors

Automation and Drives s SIRIUS 12 SIRIUS s s Class 70/71 Enclosed Starters Class 70/71 Starters Questions?