CS-100 CS Marketing Group, LLC.

Slides:



Advertisements
Similar presentations
EEE 491 Biomedical Engineering Compiled by Dr. Khawza I Ahmed
Advertisements

2/9/2014 The Prevalence and Prognostic Significance of ECG Abnormalities For: ECG in Ischemic Heart Disease By: V. Froelicher, MD Palo Alto VAHCS and Stanford.
Cardiac Cycle The two atria contract at the same time, then they relax while the two ventricles simultaneously contract. The contraction phase of the ventricle.
1 Supersensitive magnetocardiographic system for early recognition, precise diagnostics and monitoring of heart diseases Kiev Dr.Volodymyr Sosnytskyy.
Chapter 25 Medical Testing
Filters and Enveloping - A Practical Discussion -
PET AND PET/CT IN ISCHEMIC HEART DISEASE
Off pump CABG has been performed for the first time 40 years ago. Although conventional CABG is considered both safe and effective, the use of CBP.
10/10/2014Copyright, Adams Meditech, CS-100 (CardioStation – Model 100) An ECG Acquisition and FCG (Frequency CardioGram) Diagnostic System A Preliminary.
Copyright, Trigon Medical Inc., 2008
Electrocardiography A recording of the electrical activity of the heart over time Gold standard for diagnosis of cardiac arrhythmias Helps detect electrolyte.
SEPTEMBER 2011MASSACHUSETTS MEDICAID POLICY INSTITUTE DUAL ELIGIBLES IN MASSACHUSETTS: A PROFILE OF HEALTH CARE SERVICES AND SPENDING FOR NON-ELDERLY ADULTS.
Benjamin Banneker Charter Academy of Technology Making AYP Benjamin Banneker Charter Academy of Technology Making AYP.
Confidential and Proprietary Information © 2011 Express Scripts, Inc. All Rights Reserved 1 The State of New Mexico Prescription Drug Program 2013.
Chapter 16 Anatomy of the Heart
Resting 12-Lead ECG Hillmed HM-Cardio MD.
ELECTROCARDIOGRAM (ECG)
Copyright, Trigon Medical Inc., 2008
Early Heart Disease Detection and Prevention Programs.
1st practice Medical Informatics Biomedical Signal Processing TAMUS, Zoltán Ádám
DOMENICO CORRADO, MD, PhD University of Padova, Italy
Clinical Trials. Date & location – January-November 1998, stress SPECT patients randomly received tetrofosmin or sestamibi (n~1550) Inclusion criteria.
SIGNAL PROCESSING TECHNIQUES USED FOR THE ANALYSIS OF ACOUSTIC SIGNALS FROM HEART AND LUNGS TO DETECT PULMONARY EDEMA 1 Pratibha Sharma Electrical, Computer.
A Classification Approach for Effective Noninvasive Diagnosis of Coronary Artery Disease Advisor: 黃三益 教授 Student: 李建祥 D 楊宗憲 D 張珀銀 D
Copyright © 2005 Pearson Education, Inc., publishing as Benjamin Cummings PowerPoint ® Lecture prepared by Jan Campbell T H E B A S I C S SIXTH EDITION.
ECE 501 Introduction to BME
Cardiovascular Block Electrocardiogram (ECG)
CURRENT STATUS OF STRESS TESTING JOHN HAMATY D.O..
The PARCECG system is a new revolutionizing non- invasive diagnostic tool used for testing ischemic heart disease It’s technology generates high quality.
Coronary Artery Disease. What is coronary artery disease? A narrowing of the coronary arteries that prevents adequate blood supply to the heart muscle.
Characterization of Arterial Biomechanical Properties with Ultrasound for Coronary Heart Disease (CHD) Diagnostics Group 8 Laura Tanenbaum, Sam Tavakoli,
Myocardial Ischemia, Injury, and Infarction
Ischemic Heart Diseases IHD
Cardiovascular System Block Cardiac Arrhythmias (Physiology)
Dean Handimulya UIEU 2005 Congestive Heart Failure Dean Handimulya, M.D.
Diagnostic Stress Testing
20 Cardiovascular Disease and Physical Activity chapter.
Principles of diagnsosis of ischemic heart disease Mohammad Hashemi Interventional cardiologist Department of cardiology.
Chapter 13 HEART.
Chapter 16 Cardiac Care Skills.
Predicting Coronary Stenosis by Computer-Enhanced, Resting Electrocardiogram Effect of Gender, Age, and Revascularization on Sensitivity and Specificity.
Noninvasive evaluation of patients who are at risk for sudden cardiac death DR.A.YAMINISHARIF Tehran Heart Center.
Normal electrocardiogram
Cardio Investigations. Patients presenting with chest pain may be identified as having definite or possible angina from their history alone. Risk Factor.
Copyright © 2007 by Saunders, Inc., an imprint of Elsevier Inc. Principles of Electrocardiography Chapter 48.
Lesson 3 How to diagnose Coronary Artery Disease? Diagnostic.
Silent Ischemia STABLE CAD
Cardiac Cycle ► The two atria contract at the same time, then they relax while the two ventricles simultaneously contract. ► The contraction phase of the.
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
School of Biomedical Engineering, Science & Health Systems V 2.0 SD [020204] Impedance Cardiography for Non-invasive.
Basic ElectroCardiogram (ECG) Basic ElectroCardiogram (ECG) Prepared by Ms: Alwah M. Alkathiri Mr. Hamza Ratrout Revised by: Dr. Irene Roco.
Electrocardiographs ECG. OUTLINES : Introducing what is meant by Biopotential signals. what is Electrocardiograph (ECG). The conduction system. The standard.
SEVERAL MAJOR CAPABILITIES OF CRITICAL CARE INVIRONMENT 1.Process store and intergrate physiologic and diagnostic information from various sources. 2.Accept.
Electrocardiography for Healthcare Professionals
INVESTIGATION IN CARDIOVASCULAR DISEASE. Electrocardiography ECG Process of recording the electrical activity of the heart over a period of time using.
TAHAR EL KANDOUSSI, SARA ECHERKI, NAWAL DOGHMI, MOHAMED CHERTI. SEcurite de l’Echocardiographie de stress : plutôt l’effort. Cardiology B Department, Ibn.
Electrocardiography. Anatomy of the Heart Circulation.
CLASSIFICATION OF ECG SIGNAL USING WAVELET ANALYSIS
Journal of Nuclear Cardiology | Official Journal of the American Society of Nuclear Cardiology The EXERRT trial – “EXErcise to Regadenoson in Recovery.
Electrocardiography A recording of the electrical activity of the heart over time Gold standard for diagnosis of cardiac arrhythmias Helps detect electrolyte.
The Cardiovascular System
Multi Modality Approach to Diagnosis of Ischemia in Post CABG Cases
The Structure and Function of the Heart
The European Society of Cardiology Presented by Dr. Bo Lagerqvist
Cardiac Diagnostics.
ELI 350 Late Potential Ron Amero January 2010 Features and Benefits.
Slide of 39.
Real-Time 12-Lead High-Frequency QRS Electrocardiography for Enhanced Detection of Myocardial Ischemia and Coronary Artery Disease  Todd T. Schlegel,
The Role of Stress Cardiac Magnetic Resonance in Women
Presentation transcript:

CS-100 CS Marketing Group, LLC

Copyright, Trigon Medical Devices Inc. 2011 CS-100 (Cardio Scan 100) An Acquisition and FCG (Frequency Cardiograph) Spectrum Diagnostic System A Preliminary Screening Tool To Detect Coronary Artery Diseases (CAD) Early Ischemia to Myocardial Infarction presentation 4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 Cardiovascular Disease The #1 killer and cause of disability in the world - 1 million deaths in the U.S. and 17 million worldwide every year. - Debilitates more than 5 million every year. Approximately 23% of myocardial infarctions go undetected. - #1 cause of sudden death - Irreversible debilitating condition Over $30 billion in payments were made to Medicare beneficiaries for hospital expenses. CS-100 meets the need for a risk free and cost effective screening tool to detect ischemic heart diseases in its early stage. - Preventive screening tool for primary care physicians - Detect ischemic condition that is reversible by exercise and dietary change 4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 CS-100 RESEARCH AND DEVELOPMENT A Different Approach More than 30 years research and development. Heart is a dual functioning machine – electric generator and pump. Change in heart’s physiology will cause change in EKG waveform. Apply Digital Signal Processing Principles in digitizing and transforming 12 lead ECG into frequency components of energy value (uV) at frequency (Hz). - Use differential diagnosis to identify and select diagnostic indexes. Statistically compare the value of each index against the value from the data base to determine abnormal (+) or normal (-) for each diagnostic index. From (+) indexes to detect ischemic condition from early ischemia to myocardial infarction. 4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 Schematic Flow Chart of CS-100 Electrodes Time Domain Cardiac Electrical Currents ECG Electrocardiogram Complied and Recorded FFT (Fast Fourier Transformation) Into Frequency Components Digital Signal Analysis (1) Power Spectrum (2) Phase Shift (3) Impulse Response FCG Frequency Cardiograph and Diagnostic Indexes Index Value - Data Base (30,000 tests) 4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

COMPARISON OF TESTS TO DIAGNOSE HEART DISEASES Test Average Test Risk Time Cost/Test Accuracy Limitation Stress Test Moderate 20 min. $300 50-70% High false reading for abnormal ECG Chemical Moderate 4 hours. $3,800 80-90% Higher false positive if Stress Test hypertensive Angiogram High 8 hours. $10,000 95-98% Highly invasive, expensive CS-100 None 12 min. $2,000 94-97% Accuracy is similar to heart catheterization, non- invasive. * The expensive and non-routinely used Ultra-Fast CT Scan & PET technology are not included for comparison. 4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 CS - 100 ADVANTAGES & BENEFITS - Non-Invasive (No Injection or catheters required) - No Strenuous Exercise Required (Patient is at rest) Safe and Easy to Operate On-site Diagnosis for CAD in 12 minutes High Sensitivity High Specificity Limited Training Required Cost Efficient 4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 What the Experts Say: “This technology (cardio spectrum diagnostic system) is a signature new method of early Screening for heart diseases. It is --- a very simple, fast, and non-invasive method ----- and should be used in clinics where cardiac screening is performed, as well as by primary care physicians.” William J. Tenet, M.D., New York Hospital – Medical Center of Queens “This technology (cardio spectrum diagnostic system) will provide a significant new method of early diagnosis of heart diseases.” Marne Def. Gomes, M.D., Dean of Institute of Cardiology, Foundation University of Cardiology – Brazil “Frequency Domain FCG may index LVH with a high accuracy and the prediction of MID is largely superior (based on F statistics) to standard time-domain ECG parameters, either taking voltage alone or time-voltage integral into consideration. It may thus be a new tool to help indexing the probabilistic presentation of LVH.” Paolo Emilio Puddu, Institute of Heart and Great Vessels, Ls Sapienza University, Rome, Italy 4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 CS – 100 Opening Page FCG Spectrum Analysis 4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 CS-100 Important Features This device complies with the accepted specifications to provide the maximum safety to patients and operators. A Window based touch screen diagnostic system with an easy to operate menu. Acquire 10 leads ECG signal simultaneously and continuously for up to one hundred and ten seconds. Two ECG time-domain waveform display (6x2 and 12x1). Frequency Analysis with CS-100 spectrum displays. Five power spectrum diagnostic indexes for each of the 12 leads. - Five special diagnostic indexes for Lead II and V5.   4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 ECG (Electrocardiograph) CS-100 has the ECG data acquisition capability to acquire and record a conventional 12 lead ECG simultaneously; and to display and print out the ECG graph in two different formats: 12x1 and 6x2 12x1 ECG Wave Display 4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 - Also can display and print out a 6 x 2 ECG 6 x 2 ECG Wave Display 4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 FCG (Frequency Cardiogram) Unique and Valuable System - An Innovative and scientifically proven system. - High degree of sensitivity and accuracy. - Cardiac screening for early diagnosis of heart disease. - Preventive warning for reversible ischemia. - Detection of ischemic myocardium injuries which may eventually lead to more serious heart problems.   4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 FCG (Frequency Cardiogram) Advanced Technology - Automatically amplify, filter and digitize the 12 lead cardio-electrical signals; - Transform those digitized signals into 12 individual frequency domain spectra; - Calculate and Determine (+) or (-) for each diagnostic index; - Frequency range from 0 Hz to 25.6 Hz with much refine 0.2 Hz resolution Display and Print-out one page of power spectra with 60 diagnostic indexes (one power spectrum with 5 indexes for each of the 12 lead); - a multi-color CAD location picture, and frequency graph for power spectrum, phase angle shift and impulse response and their respective diagnostic indexes for lead II and V. 4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 FCG Power Spectrum - CS-100 displays and prints out a power spectrum with all 12 leads on one page; - Each power spectrum lists five (5) ischemic diagnostic indexes 12-Lead FCG Power Spectra with Ischemic Diagnostic Indexes 4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 12 LEAD POWER SPECTRUM can detect   - Insufficient myocardial energy caused by lack of blood supply (Early Ischemia) - Myocardium injuries - Ventricular hypertrophy or Ischemic Cardiomyopathy - Myocardial Ischemia - Myocardial compensation has set in for one or more years - CAD and its location 4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 Two Lead Analysis: analyze the digitized data from the two leads (V5 and II) to determine the (+) or (-) for one diagnostic index designated for phase shift and five (5) indexes for impulse response; and Display and print out a two-lead frequency graph showing two power spectra (one for lead II and one for lead V5, one phase shift and one impulse response. FCG Power Spectra for Lead II and Lead V5, and Their Phase Shift and Impulse Response 4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

Copyright, Trigon Medical Devices Inc. 2011 Two Lead Analysis can detect: - Poor blood flow to the heart, poor blood circulation and change of blood dynamics. - Poor or defective conduction function, unstable cardiac electricity. - Left bundle branch conduction block. - CAD , coronary artery blockage, or myocardial infarction (MI).   - Unstable latent cardiac electrical activities at the beginning of contraction.   4/6/2017 Copyright, Trigon Medical Devices Inc. 2011

For More Information Contact: CS Marketing Group, LLC Email: webmaster@cs100group.com   4/6/2017 Copyright, Trigon Medical Devices Inc. 2011 19