HS-30 Hydrostatic Pressure Sensor Presented By Peter Ward Hydrological Services Pty Ltd.

Slides:



Advertisements
Similar presentations
3 rd Generation SunSaver. SunSaver Generation 3 Legacy Design: Same Size Controller Same Amp and Voltage Ratings Same Mounting Plates Same Easy Battery.
Advertisements

Residential Gas – Honeywell Valve - Thermopile Powered Series 300/301
Page 1 Koasis II Specifications & Operation. Page 2 1.System Design Map Water Tank Fertilizer Tank A Fertilizer Tank B Fertilizer Tank C Filter Automatic.
FLUID BED GRANULATION SWITCH CABINET MANUFACTURER : GLATT AG
IGVC Power Team (BZZZZT!) Presentation October 17 th Electrical Engineering Senior Projects 1 Nate – Jake – Tim.
Unit C: Agricultural Power Systems
Pneumatic Valves Lesson 4.
CLASSIFY SIDES PYTHAGOREAN THEOREM CLASSIFY ANGLES SIMPLIFY RADICALS MISC
VSH2 Nitrogen Over Hydraulic Unit
Hydrological Services Pty Ltd Sydney, Australia Bill Barratt CEO AHA Conference July,04 © Copyright.
SITOP power Automation and Drives SITOP modular The First Modular Power Supply SITOP - a step ahead.
Click left mouse button to advance, back to return Refrigeration HVAC control & monitor system Presscon Network & Pressnet Software Click left mouse button.
ONE LAPTOP PER CHILD This works are licensed under a Creative Commons Attribution 2.5 License. One Laptop per Child Laptop Power November 18, 2008 One.
Coach Air Conditioning
WATER LEVEL MEASUREMENT
Aquaox ECS series The new standard in ECA technology
It all started simple…. One Alternator One Battery One Starter Motor.
CLEAN FORMAT FASTER NAVIGATION PRODUCT SELECTION GUIDES UPDATED INFORMATION WEBSITE ENHANCEMENTS.
Convection Temperature Device
THE DEVICE, THE FEATURES & Centralized Management System (CMS)
Hydrological Services Pty Ltd Heater Model TB323LP For Model TB3 Tipping Bucket Raingauge Presented By W.R. Barratt CEO Copyright.
Energy Efficient Steam Systems
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
1 The YL9100S HPLC All your needs for semi-preparative applications.
ERA SOLAR PRODUCTS ERA Renewable Energy. Solar energy is the ultimate source of energy from millions of years and it is a renewable energy. This energy.
Product information. System Overview Functions: The inside of the [ventilationVest] is made of 3- dimensional pressure-resistant flexible fabric. It is.
BATTERIES AND BATTERY CHARGING
BeginningNext SlideBack End Program AVADAL 1 of 16 SK-13 PRESSURE REDUCING MODULE.
Rainfall (Siren Activated) Flood Warning System Hanoi, Vietnam 7 th November 2008.
SITOP power facets A&D SE PS SITOP power Automation and Drives SITOP power flexi The power pack handles it all - from 3 to 52V SITOP power.
Making Landmark or Friendly Numbers (Multiplication)
AIM Armstrong’s Intelligent Monitoring Training presentation.
JOHN DAY SCREEN AND PASSAGE PROGRAM: CURRENT ISSUES Presented by Michael Jensen John Day Shop Manager.
BeginningNext SlideBack End Program AVADAL 1 of 21 SK-1 Roller Apron Segment Overview.
Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
Customer Service – International dept. STAR 24 3 E.
ADVANTAGES Water savings Crop response Labour savings Fertilizer savings Less weed growth Drip Irrigation System Layout & Design.
1 Kraft Fuels LPG Products & Services Your Logo Here Franz Keiling An Overview about LPG Dispensers and Technology Franz Keiling An Overview about LPG.
Service Export VICTRIX. VICTRIX Instantaneous boiler  VICTRIX 26 2 I Heating only prearranged for external cylinder connection  VICTRIX X 12 2 I  VICTRIX.
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Chapter 31B - Transient Currents and Inductance
Engineer Training XL1200 Ink System. Engineer Training XL1200 Ink System Confidential 2 Ink System The XL1200 Ink System consists of the following elements:
DRIP DISPERSAL SYSTEMS Problems and Solutions Presented by Keith Surface.
Home Refueling. Phill Technical Training Natural Gas Vehicle Components What is a Natural Gas Vehicle?
Perform Control Test. Check for Consistent Liquid Temperatures Entering and Leaving Liquid Temperatures should be close when the water pumps are on but.
FoamPro 1600 Series Fully automatic Class A foam ONLY
Thermal Power Station Plant. Introduction 150 MW Thermal power station plant, produce 450t/hr steam at full load The max steam pressure is 150 bar with.
GAS PURGE SYSTEMS ‘Manly Hydraulics Laboratory’ 28 th June 2011.
1 Expansion Tanks. 2 3 Expansion Tanks WHY USE THEM TYPES LOCATION SIZING.
Booster System Basics: Constant Speed Systems
Medical Gas Alarm Panels
Normal Operating Parameters Maintenance Schedule Common Problems Normal Operating Parameters Maintenance Schedule Common Problems ClearWater Tech, LLC.
Actuators.
Solar Home UPS 850VA & 1400VA India’s first Sine wave inverter with in built Solar Charge Controller and Controlled DC Load Output. Simultaneous Charging.
Hydronic Mechanical Controls
OZONE DRINKING WATER SYSTEM. CONTENTS Properties of Ozone Production of Ozone Water Treatment Plant – 25 m 3 /hr Ozone Generation System.
PUMP. AUTOMATIC WATER LEVEL CONTROL HARD WIRED PUMP AUTOMATIC WATER LEVEL CONTROL WITH INDICATOR.
Fly Ash Collection System The most important factor in determining the type of fly ash collection technology to be used is the permissible particulate.
UPS Battery Battery Sizing
Solar Powered Stop light The stop light consist of three main parts. The power source The Power converter/controller The stop light There are also a Remote.
ERU WATSAN MOD. 15 SETA plant centrifugal pump: Maintenance and replacement.
Pressure-Enthalpy and the Variable Refrigerant Cycle
CUE – Make Any Pump an E-Pump
Solar Sausage Project Water Purification Device 2/17/16.
Oil-free Vacuum Pump / Compressor Today’s Instruments Co., Ltd.
Elite Marine Yachts. Marine Boat Refrigeration Products Leading supplier of marine refrigerators and freezers Dometic Marine presents enhanced lines of.
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
14 Refrigerant Recovery, Recycling, and Recharging.
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Presentation transcript:

HS-30 Hydrostatic Pressure Sensor Presented By Peter Ward Hydrological Services Pty Ltd

HS-30 What is the HS-30? –complete Hydrostatic Level Sensor for measuring water level in dams, rivers, canals and tanks with up to 30m (164ft) of water head.

HS-30 What are the advantages? –The unit can be used with any pressure transducer – Must be used with the GCO1 – Low Power Consumption –Automatic Purge every 3 hours –Automatic Purge when the water level increases by 100mm or more –No gas bottle replacement or bubble rates to set up –Compact size Easy to install –Long periods unattended –Ideal for high silt areas –Reduced lag between water level rise and orifice pressure

HS-30 Product Overview –The Trident Model HS-30 is designed to be used with a GCO (Gas Chamber Orifice) and replace conventional Dry Nitrogen or Compressed Air bubbler systems. –A dot point view of the product is as follows : –Must be used with a GCO !! –Can be used with any pressure transducer. –Purge sequence : 1. Switch Valve (to connect pump to GCO). 2. Operate pump for 5 secs. 3. Monitor pressure for 30 secs. 4. Switch Valve back (to connect transducer to GCO). –Purge when : 1. Every 3 hours (fixed) and 2. When water level rises by more than 100mm (4 inches) or 3. Manual purge by operator. –Falling water level – excess pressure vents automatically from GCO. –Pressure on transducer is held constant during a purge. –Operates with a 12V 38Ah Battery, average consumption is 30mA (=> 40 days batt life - based on 7 x 3 hr purges and a 1m (3ft) water level rise per day) –A small 5 Watt Solar panel is sufficient to keep the battery fully charged. –Operates with up to 30m (100ft) head of water.

HS-30 OPERATION: The GCO is connected to the user’s pressure transducer through a solenoid valve. The water level is continually monitored through an internal pressure sensor (inside the HS-30 Controller) for control purposes. A purge sequence is performed every 3 hours and when the water level increases by 100mm or more. The purge sequence consists of the GCO line being switched to a pump which purges the GCO line for 5 seconds, the GCO pressure should then return to normal within 25 seconds, at which time the GCO line is switched back to the users pressure transducer for normal water level monitoring. (During this purging time, the pressure on the pressure transducer is held relatively constant through the solenoid valve – causing a minimum effect to the water level measurement – if one occurs at this instant.) When the water level is falling, excess pressure vents automatically from the GCO – so a purge is not necessary. If the battery voltage falls below 10.0V at any time (even during a purge) a low battery indication is given (red LED flash) and the purge pump will not be operated until the battery voltage rises to 12.0V, allowing battery recovery. A small 5W solar panel would be sufficient to keep the battery fully charged with an autonomy of 40 days.

HS-30 Specifications –Power : –Operating Voltage : 12V DC Nominal –Recommended Battery :12V DC Sealed Lead Acid (38Ah) This will provide approx 40 days continuous operation. (allowing for battery self discharge) –Low Battery cut-out : 10.0 V DC –Battery recharge recovery : 12.0V DC –Operation Range : Up to 30m (100ft) of water pressure head –Purge : –Compressor Current : 15.5 Amps for 5 secs –Solenoid Current : 0.6 Amps for 30 secs –Electronics Quiescent :10 mA –Average battery consumption :30mA continuous (based on 7 x 3hr purges and a 1m water level rise) –Solar : A small 5Watt solar panel is sufficient to keep the battery fully charged. –Purge Sequence : 5 secs - compressor – 25 secs - solenoid valve – Once every 3 hours (fixed) and when the water level increases by 100mmor a manually initiated purge –Maximum Pump Pressure : 600 kPa (85 psi) –Minimum Pump Pressure : 400 kPa (60 psi) –Transducer Pressure Connection :1/4 inch tube –River Line Connection : 3/8 inch tube –Max River-line Length : 200m (600ft) using 3/8 in OD and 1/8 ID tubing –Air Dryer : 5 year maintenance free “Self Purging” Hydrophobic filter –Operating Temperature Range : -30oC to +70oC –Cabinet Size : 400mm x 300mm x 200mm (H x W x D), 16 inch x 12inch x 8 inch –Weight : 13 kg (29 lbs)

HS-30 Questions?