Product Presentation C-PTD 180/AIR/QC Air-cooled Peltier Temperature System 28.02.2013
Article Number and Price Configuration Example Content Pictures Features and Benefits Specification Performance Measurements Special Features Article Number and Price Configuration Example Applications and Markets Competition Summary 28.02.2013
Pictures P-CTD 180/AIR/QC 28.02.2013
Features and Benefits C-PTD 180/AIR/QC Temperature Range Complete range: 0 °C to 180 °C Measuring Systems Concentric Cylinder Measuring Systems Disposable Measuring Systems Stirrers and Spindles Air-cooled Peltier system No counter cooling necessary Typical Measurements Isothermal temperature tests Temperature ramps Temperature swing tests 28.02.2013
C-PTD 180/AIR/QC - Specification Temperature range 0 °C to 180 °C Measuring systems Standard systems, DG42 Beaker Standard beaker, max. CC39 or DG42 General Good cleanability Radiation system for counter cooling Surrounding conditions Temperature range 5 °C to 35 °C Relative humidity, not condensing < 80 % Altitude Up to 2000 m Pollution Pollution degree 2 according to EN 61010 Surrounding Laboratory, indoor us only Supply Supply voltage 85 to 265 V Frequency 50 … 60 Hz Overvoltage Overvoltage category II according to EN 6100 28.02.2013
Technical Specification – Heating Rates Comparison Peltier / Liquid Temperature Control Heating rate (Peltier): 8.0 °C/min Heating rate (Liquid): 5.0 °C/min 28.02.2013
Technical Specification – Cooling Rates Comparison Peltier / Liquid Temperature Control Cooling rate (Liquid): 0.5 °C/min Cooling rate (Peltier): 4.0 °C/min 28.02.2013
Examples - Heating Stable Conditions after approx. 15 min 28.02.2013
Examples - Cooling Stable Conditions after approx. 15 min 28.02.2013
Wide temperature range: 0 °C to 180 °C Special Features Wide temperature range: 0 °C to 180 °C Air cooled Peltier temperature system Rapid changes in temperature No external controller necessary No counter cooling by an external circulator Easy to install Space saving design Noise reduced 28.02.2013
Peltier Temp. Control System Temp. range: 0 to 180 °C Article Number Item-no.108642 C-PTD 180/AIR/QC Peltier Temp. Control System Temp. range: 0 to 180 °C 28.02.2013
Standard Configuration Basic Instrument RheolabQC 108642 C-PTD 180/AIR/QC 20654 Disposable Measuring System CC39/D/QC-LTD 20655 Disposable Measuring System CC27/D/QC-LTD Option: 18385 Software Rheoplus 28.02.2013
Applications & Markets Coatings: Flow Curve, Yield Point, 3ITT (Thixotropy) Food: Flow Curve, Yield Point, Temperature Test, Building Materials: Flow Curve, Yield Point, 28.02.2013
Applications & Markets Adhesives: Flow Curve, 3ITT (Thixotropy), Temperature Test Cosmetics: Flow Curve, Yield Point, Temperature Swing Test Pharma: Flow Curve, Yield Point, Soft Gels: Yield Point, 3ITT (Thixotropy) Lubricants, Oils: Flow Curve, Temperature Test Asphalt: Flow Curve, Temperature Test 28.02.2013
Wide temperature range: 0 °C to 180 °C Summary C-PTD 180/AIR/QC is the new Peltier temperature system for the RheolabQC with: Wide temperature range: 0 °C to 180 °C Air cooled Peltier temperature system Cheaper configuration compared with the liquid temp. control systems Compact design, no counter cooling by an external circulator Easy handling Small footprint Noise reduced compared to a fluid circulator Low power consumption Fast and accurate temperature setting no thermal fluids/oil necessary Firmware V1.26 for the RheolabQC required 28.02.2013