MAVS Current Measurement

Slides:



Advertisements
Similar presentations
Stratagem EH4 Field Evaluation of Data Quality.
Advertisements

Crown XTi Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display Updating.
MP200 Presentation MICRO-BIT TECHNOLOGY, INC..
Chapter 5 Computing Components.
Chapter 5 Computing Components. 5-2 Chapter Goals Read an ad for a computer and understand the jargon List the components and their function in a von.
MAO Flow Meters Sales Deck | Presentation Title What is the MAO Flow Meter? The MAO flow meter is an instrument used for monitoring or measuring.
SPiiPlus Feedback Tuning
Chapter3 Pulse-Echo Ultrasound Instrumentation
Crown CDi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
Analog Representations of Sound Magnified phonograph grooves, viewed from above: When viewed from the side, channel 1 goes up and down, and channel 2 goes.
Construction Surveys
Operating Functions.
MULTIMEDIA TUTORIAL PART - III SHASHI BHUSHAN SOCIS, IGNOU.
Crown DSi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
RD Instruments Home of the ADCP Measuring Water in Motion and Motion in Water THETIS Waves Data QA RD Instruments Home of the ADCP.
Using a DPS as a Coherent Scatter HF Radar Lindsay Magnus Lee-Anne McKinnell Hermanus Magnetic Observatory Hermanus, South Africa.
Lock-in amplifiers Signals and noise Frequency dependence of noise Low frequency ~ 1 / f –example: temperature (0.1 Hz), pressure.
BE-2110i VF/WIDEBAND TRANSMISSION TEST SET OPERATING OVERVIEW Slide 1 of 9.
Rotary Encoder. Wikipedia- Definition  A rotary encoder, also called a shaft encoder, is an electro- mechanical device that converts the angular position.
1 ADCP Primer OC679: Acoustical Oceanography. 2 Outline ► Principles of Operation   The Doppler Effect The Doppler Effect   BroadBand Doppler Processing.
Data Acquisition Concepts Data Translation, Inc. Basics of Data Acquisition.
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Closed Conduit Measurement Techniques  Pipeline systems  Transmission lines  Pipe.
MWAVES Wave Sampling Nobska Development, Inc. Albert J. Williams 3 rd Archie Todd Morrison III.
RAPID-MOC Mooring Array Instrumentation l Instrument types and specifications l Telemetry.
Initial Position Orientation Tracking System (IPOTS) Group Members: Keiichi McGuireHenry Pham Marc TakamoriScott Spiro.
How can we get a vertical profile of the wind in the atmosphere?
Lecture161 Instrumentation Prof. Phillips March 14, 2003.
William Stallings Data and Computer Communications 7th Edition (Selected slides used for lectures at Bina Nusantara University) Data, Signal.
How can we get a vertical profile of the atmosphere?
Monroe L. Weber-Shirk S chool of Civil and Environmental Engineering Closed Conduit Measurement Techniques ä Pipeline systems ä pipe networks ä measurements.
NorCal Tech 2005 Technical Conference
Electromagnetic Flowmeter Why use flow meters What is a magnetic flow meter – How do they work – How are the different from other meters Items that will.
AccuMax Multi-Point Injection Mechanics
Doppler Radar From Josh Wurman NCAR S-POL DOPPLER RADAR.
Lease Automatic Custody Transfer
Presented by Emil Melamed
1 AFPS. 2 AFPS: Automatic Floor Pressurization System This special application, which modulates the fan speed by means of a differential pressure sensor.
GML-3 GPRS BASED METER AND LOGGER THREE PHASE METER WITH INBUILT DATA LOGGER © Embuilt Technologies Visit us at Or For.
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
Copyright © 2010 Pearson Education, Inc. Lecture Outline Chapter 25 Physics, 4 th Edition James S. Walker.
Ircon ® ScanIR ® 3 Linescanner How to work with Snapshots? Confidential Rev. A 07/2013.
MagicInfo Pro Scheduler Now that a template has been created from content imported into the Library, the user is ready to begin scheduling content to.
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
GCS 300 System Operation Application – Level 1.
Bertinoro Advanced Training T-RDI: Marine Measurements 1Mar2007.
You Can Measure the Benefits… Training Course SmartScan Setup & Configuration.
Measuring the flow of water
8114A Overview. 8114A Overview 10-Feb-04 Page A Overview 1) Specifications and Applications 2) Operational Overview 3) Block Diagram.
1 April 29, 1999 ZENO DATALOGGER Texas Natural Resource Conservation Commission.
First results from the Biocams J. Brunner. Cameras on floor 1 and floor 5 together with an OM and an ADCP Floor 1 –80m above sea floor Floor 5 –270m above.
Chapter 25 Electromagnetic Waves. Units of Chapter 25 The Production of Electromagnetic Waves The Propagation of Electromagnetic Waves The Electromagnetic.
CHAPTER 5: Data sampling design, data quality, calibration, presentation Sampling Physical variables are continuous, but samples (water samples) and digital.
Hardware Introduction – Standard vs Q.i
Calibration instructions for Quarknet Cosmic-Ray Detector How to Plateau the Counters A friendly guide for students and teachers Edited by Jeremy Paschke,
Sounding Board Programming and Data Retrieval 1. Sensoplex Software Download the Sensoplex files onto your computer’s desktop Extract all files Install.
F-900 PORTABLE ETHYLENE ANALYZER INSTRUMENT TRAINING
ATM-900 Series Acoustic Telemetry Modems Introduction and Overview Communication Group: Justin Manley – Senior Director of Business Development Debbie.
Electronic instrumentation Digitization of Analog Signal in TD
Calibration Instructions for Quarknet Cosmic Ray Detector
BME 312 BIOMEDICAL INSTRUMENTATION II LECTURER: ALİ IŞIN
Ultrasound Physics Image Formation ‘97.
Residential Metering: iPERL vs Ultrasonic meters
SONARtrac® vs Ultrasonic Flowmeters
Ultrasound Physics Image Formation ‘97.
McCrometer Nano Board Test Procedure
Neurochip3.
The Instrumentation Unit of The KM3NeT Calibration Unit
Diagnostics Analytical 920 LC Semi-Prep 940 LC
Wavewin Sniffer 24 Configuration & Polling Software
724 Temperature Calibrator
Presentation transcript:

MAVS Current Measurement Nobska Development, Inc. Albert J. Williams 3rd Archie Todd Morrison III

Current Measurements Mechanical Sensors Electro-Magnetic Sensors Doppler Sensors LDV Acoustic Doppler Acoustic Doppler Profiling Acoustic Travel-Time Sensors

Mechanical and EM Sensors Rotor, vane – operate at very low power but have poor response in low flows and in oscillatory motion Fan type – operate at low power, have good response in oscillatory flow but exhibit dead band in low flows Electro-Magnetic 2-D, no dead band but response is poor to accelerating flow, far field of electric field makes calibration awkward in a tow tank

Doppler Sensors LDV – Laser Doppler velocimeters Narrow range of particle densities over which it has good signal, requires many realizations to obtain low velocity noise Acoustic Doppler single point sensors df=(f1-f0)=2f0(u/c)cos(a), where a is the angle between the acoustic beam and the current ADV sensor is bistatic and measures velocity components at a point. There are three acoustic paths Acoustic Doppler current sensors suffer from weak returns if there are few scatterers and may lock onto spurious returns from supporting structures with zero velocity. Scattering volume is remote from sensor head and fairly large

Doppler Sensors Acoustic Doppler profilers (ADCP) An entire profile of velocity is obtained Monostatic, three or four acoustic axes diverge from transducer head Pulse burst must decay before next burst is transmitted Range depends on frequency, 300kHz gives about 150 meters range with good scatterers Individual burst has large ambiguity in velocity, many pings must be averaged to obtain speed resolution desired

Doppler Sensors Acoustic Doppler profilers (continued) Velocity resolution*repetition rate = constant for any particular frequency Range*velocity resolution*repetition rate = constant allowing frequency to be selected for desired range. This tradeoff limits use of ADP for turbulence measurements as well as large ensonified volume Broadband encoded bursts in BBADCP permit effectively more pulses at once and this constant is increased proportionally

Acoustic Travel-Time Sensors Defined acoustic path along which fluid velocities are averaged Depends only on the ability of the fluid to transmit sound, no penalty for moderate attenuation or for perfect clarity Linear velocity response through zero velocity

Acoustic Travel-Time Sensors c + u c - u L

Applications of Current Measurement, Requirements Transport Average over waves and mooring motions, typically 20 seconds Long deployment duration, typically 3 to 12 months Excellent directional resolution and low velocity threshold, linearity over large range in velocities Waves Bursts of duration capable of resolving spectrum at modest sampling rate, typically 20 minutes at 2 Hz Burst interval related to wave development, typically 2 hours Boundary layer turbulence High frequency sampling, typically 20 Hz Fine spatial resolution, typically 1/3 of distance from the boundary

Current Meter Moorings and Rigid Supports Mooring cage Carry mooring tension around current sensor Bottom Tripod Sensor inside tripod or sticking up in cage, MAVS illustrated In-line support Near bottom with float, MAVS illustrated at Juan de Fuca hydrothermal vent Piling Rigid mount above bottom in shallow water

Nobska - MAVS3 Modular Acoustic Velocity Sensor 3rd Generation "Standard" MAVS3 with CTD option Nobska

Memory TT8 MAVS Flash (ROM) SCP RAM Run-time EEPROM Configuration Deployment Definition MAVS Flash Card Data Configuration

Net Relative Velocity, Tilt, Heading COD END DIRECTION OF TOW

MAVS Specifications Sensitivity and linearity 0.05 cm/s sensitivity, 0.5% linearity (corrected to that in 2003)

MAVS Specifications Velocity zero offset stability 0.5 cm/s per deployment, no net drift with time Demonstrated sensitivity to pressure and temperature on deployment in gel to 2000 m

MAVS Specifications Cosine response Horizontal cosine response within 5% through 360° Vertical cosine response within 10% to 30° and within 20% to 45° On-axis response is 20% low but turbulence is minimum Tow tank shows test run with sensor at +45°

MAVS Specifications Compass Three magneto inductive axes in orthogonal array Tilt measured with two axis solid state accelerometer for resolution of earth magnetic field onto horizontal plane Second socket for remounting of tilt sensor for horizontal deployment of MAVS

MAVS Specifications Tilt Linearity within 1° out to 50° Temperature compensated to 0.3° of tilt between 5°C and 45°C Works equally well inverted or on 90° bracket for horizontal mounting

MAVS Specifications Toughness Fouling sensitivity Carried by submarine landslide 550 m down Monterey Canyon. Still recording pressure although sensor rings sheared off and tube bent 90°. Fouling sensitivity Stops measuring only when flow is totally blocked as in illustration Insensitive to particles, bubbles, or perfectly clear water. Only hard obstruction or swim bladder stops acoustic signal

MAVS Carried 550 m in Monterey Canyon Landslide and Buried Alive MAVS on MBARI Frame with Homer acoustic beacon ROV manipulated sand lifter exhuming frame Upper portion of MAVS exposed MAVS on deck, sensor stripped of rings and bent 90°

MAVS Operation Setup with PC and deck box: Menu mode Run a terminal emulator: Crosscut, Hyperterm, TTOOLS, Kermit, etc. Connect through the endcap to the deck box, which provides power and a DB9 connector for the PC’s RS232 serial comport Configure the comport for 38,400 baud, 8 bits, no parity Turn on power and type Control C

MAVS Operation Setup with PC and deck box: MAVSoft mode Bring up MAVSoft on the PC Connect through the endcap to the deck box, which provides power and a DB9 connector for the PC’s RS232 serial comport Turn on power

MAVS Operation Set time: Menu mode Set time: MAVSoft Mode When screen says “Change time & date?” type y <enter> Type month_day_year_hour_minute_second <enter> Set time: MAVSoft Mode Push button “SET TIME” Push button “Send PC Time to MAVS”

MAVS Operation Calibration: Menu mode, select Calibration Select Velocity Offsets: V <enter> Place sensor in still water Type M, <enter>, <enter> Accept if STDV values are less than 0.15 cm/s Select Compass Offsets: C <enter> Follow instructions Select Tilt Offsets: T <enter> Save constants and exit Type x, <enter>

MAVS Operation Calibration: MAVSoft mode, select MavsTerm Select Calibration: 3 <enter> Select Velocity: V <enter> Place sensor in still water Type M, <enter>, <enter> Accept if STDV values are less than 0.15 cm/s Select Compass Offsets: C <enter> Follow instructions Select Tilt Offsets: T <enter> Save constants and exit Type x, <enter>

MAVS Operation Deploy: Menu mode, select Deploy Frame, select MAVS, earth Cartesian, or earth speed and direction Logging enabled as append or overwrite Beware of overwriting data before reading it but beware of starting with a partially filled compact flash Measurement frequency, number of measurements per sample Samples per burst, burst interval Delayed start (Start Time), duration of deployment G <enter> to get analysis of battery and data storage duration There are opportunities to revise deployment parameters

MAVS Operation Deploy: MAVSoft mode, from Control Panel select Parameters, press UPLOAD Select frame (MAVS, earth Cartesian, or earth speed and direction) Enter measurement rate, number of measurements per sample, samples per burst Set burst interval and bursts per file Establish the deployment schedule Select Enable Logging to Flash Card and check append or uncheck for overwrite Press DOWNLOAD to put these parameters into MAVS In Control Panel push DEPLOY As data appear, select START LOGGING and name file for capturing data on the screen.

MAVS Operation Offload: Menu mode Offload: MAVSoft mode Control C to get control (may need to do this three times if MAVS is in a Low Power Sleep) 7 <enter> Capture conversation with terminal (alt z in Crosscut) Offload: MAVSoft mode Select Offload Name file to which the data will be captured

MAVS Operations Flash Card Ops: Menu mode Control C to get control 2 <enter> Note data files with selection 2 Data files contain data Config.bin, Deploy.bin, and f_count.bin are required for unpacking data Select 4 <enter>, open MAVS case, and remove compact flash card Copy card contents to PC with Microsoft copy command. Then return compact flash to MAVS and type <enter> again.

MAVS Data Analysis MAVSPack Plot Run MAVSPack selecting the folder into which the contents of the compact flash were copied. This converts from binary files to ASCII data files and ASCII configuration and deploy files. Plot Load into Excel Select columns for time, u, v, w and other ancillary parameters. Time may be generated from hours, minutes, and seconds as fractional hours Select plot as scatter plot Or load into Matlab Generate m files for data manipulation and plotting

MAVS Deployment Choices Low energy flow Long deployments, infrequent samples Wave “interference” Average over wave or mooring motion, measurement frequency high enough to resolve motion Wave spectra Measurement frequency high enough to resolve highest frequency wave Burst long enough to resolve wave bands Burst interval short enough to resolve change in wave climate Turbulence Highest frequency to resolve turbulent eddies, burst to extend duration of deployment

Batteries for MAVS Basic alkaline Lithium Double lithium 4.8 ah at 12 volts Lithium 9.6 ah at 12 volts Double lithium 19.2 ah at 12 volts Power consumption is reduced by allowing time between bursts so MAVS can go into low power sleep

Data Storage for MAVS Compact flash memory 16 MByte CF 64 MByte CF 256 MByte CF Other capacities available to 1 GByte or more Industrial rating required for temperature range of application

Real Time MAVS RS232 output RS485 output Power source 100 foot limit Half duplex, not supported by MAVSoft More than 1000 feet possible Power source 12 volt low impedance (must provide 2 amps for 15 ms each measurement) 24 volt with internal regulator, typically 60 ma

Ancillary Sensors for MAVS Pressure Omega or Druck, 20 meters to 6000 meters full scale range External temperature Precision of 0.03°C and accuracy of 0.1°C Internal temperature standard with precision of 0.03°C and accuracy of 0.5°C Conductivity Aanderaa inductive head, range 0 to 75, resolution 0.02, and accuracy 0.2 mS/cm Optical turbidity OBS, LBSS, or SeaPoint Analog voltage from external source

Analog Output MAVS Integration with existing data systems Output voltage range +/- 5 v for +/- 180 cm/s External strobe possible Calibration signals provided

Other Specials for MAVS Bent sensor 90° right or left bend of sensor from body 90° up or down bend from body Inverted sensor, vertical up or down With solid state compass and tilt meter, this is standard, selectable by user from the setup menu Horizontal sensor Internal tilt sensor must be moved from vertical socket to horizontal socket and the change entered in the setup menu

Setup Menu for MAVS Configuration parameters may be changed in the setup menu, accessible with a password to prevent accidental entries S <enter> WHIPR <enter> gives entry Orientation can be selected Ancillary sensors can be disabled or enabled X <enter> stores new configuration

Downloading New Versions of MAVS Firmware Enter TOM8 monitor Type q <enter> nobska <enter> Change communications setup for a baud rate of 9600 Download and open new distribution software, MAVSxy_z.zip MPREPxyz.rhx and MAVSxy_z.ahx is the new software release to load to MAVS In Crosscut select Tattletale, Load S-record, and MPREPxyz.rhx Type G, select previous version from the menu Next load MAVSxyz.ahx Accept the burn to flash memory Type G Change baud rate back to 38,400