Closed Transition ATS’s

Slides:



Advertisements
Similar presentations
All Russelectric 4 pole Open Transition ATS’s have a fully rated -break before make- switched neutral, identical in every way to the main power poles and.
Advertisements

“Power Factor” In Transmission System
Seminar on Circuit Breaker
CONDITIONS FOR SUCCESSFUL INTERRUPTION:
POWER QUALITY BACKGROUND & ELEC-SAVER TVSS
Automatic Transfer Switch (ATS)
Variable Frequency Drives Bypass Options
Introduction to Switchgear
Electrical Installation
1. Four LLs were published in February Transmission Relaying – Undesired Blocking 2.Lack of Separation for Critical Control Power Supply Leads.
Submitted by: Name:Rajendra Kumar Choudhury Branch:Electrical Engg.
Traction Control of Electric Locomotives
DOD Microgrids The Missing Link: Microgrid Applications Michael Dempsey P.E. Burns & McDonnell June 12, 2013 © 2013 Burns & McDonnell. All Rights Reserved.
©2011, The McGraw-Hill Companies, Inc. Chapter 4.
Hydraulic Circuits.
LP33 Series UPS kVA 400Vac/CE
LAFA Food Distribution July 26, Introduction:
© 2010 Eaton Corporation. All rights reserved. Neutral Switching of Grounded Sources Dave Loucks, PE.
ATS Popular Features and Accessories John J. Stark Marketing Services Coordinator, Russelectric Inc.
Transferring Inductive Type Loads John J. Stark Marketing Services Coordinator, Russelectric Inc. (Refer to Russelectric Technical Brief: “Eliminating.
IMPACTS OF LARGE DISTRIBUTED GENERATORS ON CENTERPOINT ENERGY’S DISTRIBUTION SYSTEM 1 Presented by Ed Briggs, P.E. Manager of Electric Distribution Planning.
SHUNT CAPACITOR FUNDAMENTALS AND PROTECTION
Shipboard Electrical Distribution …“Shifting the Electric Plant to a Normal Full Power Lineup.”
Basic Electricity.
One solution, many application Integrated Electronic Solution PowerSupply Flex.
Solar Home UPS 850VA & 1400VA India’s first Sine wave inverter with in built Solar Charge Controller and Controlled DC Load Output. Simultaneous Charging.
PowerPoint ® Presentation Chapter 12 Utility Interconnection Distributed Generation Generators Inverters Interconnection Codes and Standards Interconnection.
Chapter 7 SYSTEM PROTECTION
UMKC Senior SUBSTATION DESIGN TEAM
SISTEMA Example One. Schneider Electric – Sistema Example 1 – June Example 1: Start/Stop Facility with Emergency Stop Device Circuit Diagram.
Interconnect Protection of Dispersed Generators
THE ELECTRIC SUB STATION
Shipboard Electrical Distribution References Required Introduction to Naval Engineering – Ch 17.
1 Power Quality Mary Santori, P.E. Senior Engineer September 12, 2013.
Motors in Power System Dynamics Studies John Undrill NATF - Dallas - June 2015.
Prepared By :.  Introduction  Techniques Used  Case Study  Advantages  Application  Conclusion OUTLINE.
Hydraulic Circuits.
LAFA Food Distribution
Frankfurt (Germany), 6-9 June 2011  PV in Spain: Basically Large plants connected to MV or HV Mainly in rural areas (generation exceeds consumption) 3,000.
Power System Fundamentals EE 317 Lecture 9 27 October 2010.
Need for protection Power system must be kept in operation continuously without major breakdowns This can be achieved in two ways: 1.Implement a system.
Queensland University of Technology CRICOS No J Protection of distributed generation connected networks with coordination of overcurrent relays.
Power Plant Construction and QA/QC Section 4.3 – Electrical Interconnections Engineering Technology Division.
Announcements Read Chapters 10 and 11
1 Distributed Generation and Power Quality-Continued.
Submitted to: Submitted by:
Neptune Power Versions compared 1 All rights reserved © 2003, Neptune Power sub-system Versions 1 and 2 Key features V2 is functionally equivalent to V1.
Main contacts closed – RED Colour with ON
1 © 2015 Eaton. All Rights Reserved.. Suggestion on How to Use Industry Trainers are encouraged to use this material in their sessions Download the presentation.
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
VACUUM CIRCUIT BREAKER. WHAT IS A CIRCUIT BREAKER A circuit breaker is an equipment that breaks a circuit either manually or automatically under all conditions.
ECE 498HZ: Power Distribution System Analysis
MCB Connor, Sunny, Kia. What does it do? A circuit breaker is an automatically operated electrical switch designed to protect an electrical circuit from.
This project on Primary sub station of Visakhapatnam port trust at Visakhapatnam. It is 132kv/11kv substation with incoming feeder from APTransco and 11.
Machine Protection Review, Markus Zerlauth, 12 th April Magnet powering system and beam dump requests Markus Zerlauth, AB-CO-IN.
 The figure below shows a protection system for a transmission line, consisting of a CT, PT, a relay and its associated circuit breaker.
Power System Protective Relaying-Part One
Protection of Power Systems
Automatic Transfer Switches
Sub Station.
Interconnect Protection of Dispersed Generators
Shipboard Electrical Distribution
LV Safe Powering from UPS to Clients
What is Braking? The term braking comes from the term brake. We know that brake is an equipment to reduce the speed of any moving or rotating equipment,
Chapter 7 System Protection
DISTRIBUTED GENERATION (DG) MODELING CRITERIA SWEDE 2016
Electric braking Powerpoint presentation by:- Poonam sharma
Electrical Distribution System Basics
-Bypass/Isolation Switches-
Presentation transcript:

Closed Transition ATS’s John J. Stark Marketing Services Coordinator, Russelectric Inc.

Why Operate in Parallel with the Utility? Closed Transition Transfer of non-utility generator, re-transfer and generator test Cogeneration Peak Shaving Curtailable Rate Structure Distributed Generation I would expect most of you have a good idea why a facility would want to parallel with the utility. Since this discussion is based on parallel operation with the utility, lets take a second and quickly review the reasons one might parallel onsite generators with the utility Review Last item has gotten a lot of play these days particularly with deregulation and in many cases may be more attractive to the utility companies, than adding their own generating facilities..

Types of Operational Modes Open Transition Closed Transition

First let’s talk about open transition mode An open transition mode of operation is a method of transferring a load between two sources with an interruption of power during transfer.

L L L E E E N N N M1 M2 Open transition ATS Motor #1 drives the normal source contacts Open. M1 This is all done with very reliable mechanical interlocking and does not require an elaborate electrical interlocking design. The load source is disconnected for an adjustable period to allow regenerative power to decay Motor #2 then drives the emergency source contacts closed M2

Closed Transition Mode A closed transition mode of operation is a method of either: 1) Transferring a facility’s load between the utility and generator or 2) operating a generator in continuous parallel with the utility service, without an interruption of service.

Utility Concerns Reliability and quality of utility power to other customers Safety and protection of utility service personnel Protection of utility equipment

Type of Parallel Operation Passive Momentary utility parallel operation 100ms or less There are basically two types of parallel operation of a NUG (Non-Utility Generator) with the utility 100 ms overlap is accepted by many utilities with no interconnection requirements at all. However, some utilities have some minimum requirements while still others treat it no differently than if the NUG were operated in parallel for an indefinite period of time The minimum requirements for short time operation in parallel could be a simple timing circuit that times out if the contacts are in parallel for a definite set period of time and send a signal to trip the utility breaker if this time is exceeded. Still others might have some minimum protective relay requirements such aas the use of a device 32 or 27/59.

L E L E L E N N N S1 S2 Closed Transition Operation Closed transition ATS L N E L N E L N E Operator #1 drives the normal source contacts open S1 The load source is connected to both sources momentarily S2 Operator #2 drives the emergency source contacts closed Closed Transition Operation

Closed Transition Transfer Switches Advantages No interruption of power for load test and return to utility as well as peak shave operation Fast transfer operation

Closed Transition Transfer Switches Disadvantages No phase lock synchronizing No Protective relays No mechanical interlock, thus no safe manual operation Lacks true load test function Higher fault current requirements

Full 3-Phase over and under voltage and frequency Sophisticated Controls and Safety Features Full 3-Phase over and under voltage and frequency sensing on both normal and emergency sources. Protection against running over 100 msecs: Signals to operators Fail to Transfer Function Provides trip signals to the generator or utility breakers. Our Switches are controlled by the MODEL 2000 Microprocessor Control System. It Features: Full 3-Phase over and under voltage and frequency sensing on both normal and emergency sources. Voltage differential sensing for single-phase loss detection Over 30 standard accessories built in. RS 422/485 Communications Port. Windows based SCADA package available