Electric Machine Design Course

Slides:



Advertisements
Similar presentations
Stator Voltage Control
Advertisements

The stator winding are supplied with balanced three-phase AC voltage, which produce induced voltage in the rotor windings. It is possible to arrange the.
ENERGY CONVERSION ONE (Course 25741)
AC DRIVES There are two type of AC motor Drives :
Induction Motor •Why induction motor (IM)?
ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.
Power System Fundamentals
Chapter 4 Synchronous Generators
SYNCHRONOUS MACHINES SUBMITTED BY: Ms. APOORVA KANTHWAL
Electro Mechanical System
Lesson 33 AC Generators.
Prepared by: Luis Fernando Montoya Chun-Ju Huang Ashish K. Solanki
Three-Phase AC machines
16.11s June 2006 L s Notes for Lecture 4 Analysis of Induction Machines June 15, 2006 J.L. Kirtley Jr.
Department of Electrical and Computer Engineering
Induction Motors.
Induction Motor Why induction motor (IM)? –Robust; No brushes. No contacts on rotor shaft –High Power/Weight ratio compared to Dc motor –Lower Cost/Power.
Induction Motors Prepared By : PRAGNESH, MEET, SAGAR, SAAVAN, KANISH
Induction Motors.
Power System Fundamentals EE 317 Lecture 7 20 October 2010.
Induction Machine The machines are called induction machines because of the rotor voltage which produces the rotor current and the rotor magnetic field.
EET 221 Synchronous Machines Rafiqi.
Motors and Generators.
Electric motors KON-C2004 Mechatronics Basics Tapio Lantela, Nov 2nd, 2015.
Magnetic field due to an electric current
Induction Motors. Introduction  Three-phase induction motors are the most common and frequently encountered machines in industry -simple design, rugged,
BASIC ELECTRICAL TECHNOLOGY DET 211/3
SMJE 2103 Induction Motor.
Induction motor National Research Tomsk Polytechnic University Student: R.N.Kalimbekov Group 5GM42 Teacher: O.S.Kachin Tomsk 2015.
SMJE 2103 Synchronous Generator. Scope of discussion 1)Construction 2)Rotation speed 3)Generated voltage 4)Equivalent circuit 5)Power and Torque 6)Testing.
SMJE 2103 Induction Motor.
Lesson 12a: Three Phase Induction Motors
THREE-PHASE INDUCTION MOTOR
Equations, Performance, Electrical Equivalent Circuits
Chapter 5: Speed-Torque Characteristics of Electric Motors
Induction Motors.
SINGLE-PHASE INDUCTION MOTOR
Speed control of three phase induction motor
Electric Machine Induction Motor
Lesson 16: Asynchronous Generators/Induction Generators
Induction motor control
TOPIC : 3 PHASE INDUCTION MOTOR Present By : Amit kumar.
SPEED TORQUE CHARACTERSTICS OF 3 PHASE INDUCTION MOTOR
Dr. Zainal salam; Power Electronics and Drives (Version 2),2002, UTMJB
SPEED TORQUE CHARACTERSTICS OF 3 PHASE INDUCTION MOTOR
Advanced Power Systems
Energy Conversion and Transport George G. Karady & Keith Holbert
Three Phase Induction Motors
Determination of Induction-Motor Parameters
Utilisation of Electrical Energy
Induction Motor Drives
AC Drives Dr. Adel A. El-Samahy Department of Electrical Engineering University of Helwan.
Equations, Performance, Electrical Equivalent Circuits
Electrical Machines (EELE 3351)
Summary of Material on Electric Drives Covered on July 24, 2019
Electric Machine Design Course
Electric Machine Design Course
Electric Machine Design Course
Induction Motors (Lecture 1&2)
Electric Machine Design Course
Electric Machine Design Course
Electric Machine Design Course
Electric Machine Design Course
Electric Machine Design Course
Electric Machine Design Course
Electric Machine Design Course
Electric Machine Design Course
Electric Machine Design Course
Electric Machine Design Course
Electric Machine Design Course
Presentation transcript:

Electric Machine Design Course Equivalent Circuit Parameters., Measurements and Torque vs. Speed Plots Lecture # 19 Mod 19 Copyright: JR Hendershot 2012

Measurements of IM equivalent circuit parameters The classic and oldest method for calculating the performance of the AC induction machine is by use of single phase equivalent circuits. This method is used for three principle purposes : For teaching and understanding the principles of IMs E.E. Engineering teams commissioning an IM machine with an inverter for the first time to optimize all software parameters to achieve the required output performance of the system. Before availability of simulation tools, The E.C. was used to predict performance curve results during the design process. All E.Q. Parameter values were initially calculated Validation based upon parameter measurements. Mod 19 Copyright: JR Hendershot 2012

Per-phase equivalent circuit of (3) IM Rotor Leakage Reactance Stator Current Rotor Current Stator Leakage Reactance Phase Resistance Magnetizing Current Stator terminal voltage Rotor Resist. Magnetizing Reactance Mod 19 Copyright: JR Hendershot 2012

Equivalent circuit of one phase of (3) phase machine Supply current = I1 = magnetizing I2 + working I2 Working current or torque producing current circulates in the rotor cage Flux vector drives regulate the two current components of the phase current Using constant V/Hz variable speed control magnetizing current is regulated by ratios: 460V/60Hz = 7.67 V/Hz 230V/60Hz = 3.8 V/Hz Mod 19 Copyright: JR Hendershot 2012

Mod 19 Copyright: JR Hendershot 2012 The equivalent circuit parameter (ECP) measurements for AC induction machines Three standard test for AC induction motor parameters DC Test (Line to Line Resistance) No-Load Test Locked-Rotor Test Mod 19 Copyright: JR Hendershot 2012

DC Test for phase resistance The stator phase resistance (RS). Apply a DC voltage across stator windings. Measure DC voltage and current Line to line values/2 = phase values (RS) = voltage / current Mod 19 Copyright: JR Hendershot 2012

Mod 19 Copyright: JR Hendershot 2012 No-Load Test Conduct no load motor test with uncouples shaft Apply (3) balanced AC voltages to terminals @ rated f . Measure current, voltage & input power Record total losses (core, ohmic, windage & friction) Mod 19 Copyright: JR Hendershot 2012

Mod 19 Copyright: JR Hendershot 2012 Blocked Rotor Test Block rotor shaft to prevent rotation Apply (3) balanced AC voltages @ 0.25 f . Adjust AC voltage to produce rate current Measure Voltage, current and input power Mod 19 Copyright: JR Hendershot 2012

Effect of supply voltage variation with no current control Fixed frequency Prof. TJE Miller Mod 19 Copyright: JR Hendershot 2012

Torque vs. speed from grid test Mod 19 Copyright: JR Hendershot 2012

Four quadrant Torque vs. Speed plots Peak torque @ base speed Family of curves tested on an IM using a variable voltage/frequency converter Note: Peak torques below base speed limited to short times ABB Mod 19 Copyright: JR Hendershot 2012

Mod 198 Copyright: JR Hendershot 2012 Reactance components Stator Leakage Reactance X1 Slot leakage End-turn leakage Belt leakage Zig-Zag leakage Skew leakage Stator Leakage Reactance X2 Slot leakage End-ring leakage Belt leakage Zig-Zag leakage Skew leakage Mod 198 Copyright: JR Hendershot 2012

Reactances & Resistances of AC Induction machines The following causes & effects at a given voltage and frequency Magnetizing current & power factor determined by Xm If rotor saturates at low speed (f), decrease voltage Breakdown torque & starting current are determined by the leakage reactances Excessive current causes saturation near stall & breakdown Starting current controlled by voltage for constant V/Hz drives Stator & Rotor ohmic losses determined by R1 & R2 Starting torque inversely proportional to R2 Torque vs speed effected by R2 Mod 19 Copyright: JR Hendershot 2012

Equivalent Circuit solution produces Torque vs. Speed curves AC machine torque @ any fixed voltage and frequency. Breakdown Slip @ breakdown Prof. TJE Miller Mod 19 Copyright: JR Hendershot 2012

Use of Torque vs. Speed curve analysis As previously explained, IMs operating from fixed grid AC volts & frequency display speed vs torque plots featuring performance analysis with limited slip, close to synchronous rpm. Break down torque and starting torques are also of interest For IMs powered with inverters with capabilities to control both the voltage & frequency, the entire Torque vs. Speed plotted curves of both motor and inverter operating together are of interest. The motor’s peak torque is limited by it’s rotor teeth saturation as well as the inverter’s maximum current capability. The max. motor rpm is limited by the max. inverter frequency capability as well as the number of poles in the motor. Therefore this plotted capability can best be predicted by a study and analysis of 5 or 6 torque vs speed defining load points Mod 19 Copyright: JR Hendershot 2012

Torque & output power vs. RPM for an AC traction motor & inverter Requires long simulation time to calculate & plot Mod 19 Copyright: JR Hendershot 2012

(5) Load points for performance predictions The voltage & frequency is optimized for the (5) defining points on the required torque vs. speed plot. The rotor teeth must not be in saturation at load points #1 & #2 Mod 19 Copyright: JR Hendershot 2012

Phase currents & two currents vectors Mod 19 Copyright: JR Hendershot 2012

Mod 19 Copyright: JR Hendershot 2012 Title Mod 19 Copyright: JR Hendershot 2012