How to design the size of heatsink

Slides:



Advertisements
Similar presentations
MOSFET SELECTION FOR A THREE PHASE INVERTER Team 9 JR Alvarez, Matt Myers Chris Sommer, Scott OConnor.
Advertisements

Lecture-6 Thermal Design-2 Dr. Tahir Izhar
TUTORIAL 3 Q1 Draw and label a block diagram the elements of a DC power supply which receives an input from the 240 V; 50 Hz mains and produces an output.
Diodes 1.
Electronics Cooling MPE 635
Air Flow Bench Presented By: Saket Karajgikar & Nikhil Lakhkar Advisor: Prof. Dereje Agonafer.
Extended Surfaces Chapter Three Section 3.6.
Young Jo Fontaine – ME Dan Higgins – EE Shawn Hoskins – ME Luke Poandl – EE Dan Scannell - ME.
Jed Goodell Jesse Williams. Introduction Problem How much heat does a particular heat sink dissipate How many fins are needed to dissipate a specific.
Thermal Design And Analysis of High Power Electronic Boards J. Collado CHT, April 13, 2000.
Output Stages and Power Amplifiers
Output Transistors Current gain / input impedance is a vital parameter of a power amplifier. In the class A analysis, the load impedance is scaled by a.
Thermal Equivalent Circuit for a Transistor. Junction Temperature Case TemperatureHeat Sink Temperature Ambient Temperature.
CHE/ME 109 Heat Transfer in Electronics LECTURE 7 – EXAMPLES OF CONDUCTION MODELS.
Optimal Fin Shapes & Profiles P M V Subbarao Associate Professor Mechanical Engineering Department IIT Delhi Geometrical Optimization is the Basic Goal.
Output Transistors Current gain / input impedance is a vital parameter of a power amplifier. In the class A analysis, the load impedance is scaled by a.
EKT214 - ANALOG ELECTRONIC CIRCUIT II
VOLTAGE REGULATORS. Types of Voltage Regulators Zener Diode Regulators Series Transistor Regulators Low Dropout (LDO) Regulators Packaged Regulators.
Heat Sink Selection Thermal Management of Electronics
Design of Heat Sinks P M V Subbarao Mechanical Engineering Department IIT Delhi Success Based on Cooling Challenges …….
Cooling of power semiconductor devices
Lab-1,Week 1, EML 3016 C- Spring 2003 Electronic Device Cooling A thin (assume zero thickness) electronic chip has a square shape of an area 5x5 cm 2,
 Components have ratings  Ratings can be Voltage, Current or Power (Volts, Amps or Watts  If a Current of Power rating is exceeded the component overheats.
Cooling design of the frequency converter for a wind power station
CHAPTER 16 Power Circuits: Switching and Amplifying.
CHAPTER 18 Power Supplies. Objectives Describe and Analyze: Power Supply Systems Regulation Buck & Boost Regulators Flyback Regulators Off-Line Power.
Click to edit Master subtitle style 4/25/12 Thermal Management By using PLPCB technology with HEAVY Copper in PCB Pratish Patel CEO, Electronic Interconnect.
© International Rectifier DirectFET  MOSFETs Double Current Density In High Current DC-DC Converters With Double Sided Cooling.
Two Dimensional Steady State Heat Conduction
October 11,2013 ECEN 2060 Lecture 21 Fall 2013 Homework Problems\ Chapter 5 problems.
ⓒ 2013 Zalman Tech Co., Ltd. CNPS2X CNPS2X Mini-ITX CPU Cooler Sales Guide.
ⓒ 2013 Zalman Tech Co., Ltd. CNPS10X Optima CNPS10X Optima 2011 Shark Fin Blade CPU Cooler Sales Guide.
Cooling Systems. High temperatures can shorten the life expectancy of electronic components. High temperatures can shorten the life expectancy of electronic.
Copyright  2004 by Oxford University Press, Inc. 1 Diode Circuits.
TEST PROCEDURE Testing the Controller Board, Power Supply Board, and Unit as a Whole.
Voltage Divider Circuits Input transducers Input transducers are devices that convert a change in physical conditions (for example, temperature) into a.
Heat Transfer System By Team Awesome: Sub-team Awesomer.
Output Stages and Power Amplifiers Classification of Output Stages Class A,B & AB Biasing AB Power BJT.
 jc ( ° C/W): thermal resistance from transistor junction to transistor case  cs (°C/W): thermal resistance from transistor case to heat sink  sa (°C/W):
Heat Transfer Review. What type of heat transfer does this picture describe? Radiation.
Power Electronics and Switch Mode Power Supply
Modelling LED Lamps with Thermal Phenomena Taken into Account Krzysztof Górecki and Przemysław Ptak Gdynia Maritime University Department of Marine Electronics.
HNC/D Engineering Science
Heat Sinks and Component Temperature Control
From: Optimal Shapes of Straight Fins and Finned Heat Sinks
Electric-Heat Equipment
National Conference on Recent Trends in Power Engineering
Section 6: Air-Conditioning (Heating And Humidification)
Power amplifiers EL= IxRL
Chapter 21 Zener Diodes.
ECE Engineering Design Thermal Considerations
Part -3 Diode characteristics
Date of download: 12/19/2017 Copyright © ASME. All rights reserved.
Written by Tim Keyser Georgia CTAE Resource Network 2010
International Conference Power Plants 2014-Zlatibor
Dr John Fletcher Thermal Management Dr John Fletcher
Mechanical Dimensions
FREE CONVECTION – FIXED POWER TD1005
Heat Transfer in Extended Surface
THERMODYNAMIC IN ELECTRONICS
FORCED CONVECTION AND EFFECTIVE VELOCITY
MOTOR SELECTION Electric motors should be selected to satisfy the requirements of the machines on which they are applied without exceeding rated electric.
Heat transfer Chapter 7.
Introduction to Motor Drives
Written by Tim Keyser Georgia CTAE Resource Network 2010
Cooling System In I.C.E.
Mechanical Dimensions
Example Example 1: An electric lamp is rated 110 W, 200 V. When the lamp is operated at its rated power and voltage, calculate a) the current flowing through.
Output Stages and Power Amplifiers
Electric Machine Design Course
Presentation transcript:

How to design the size of heatsink

How to design the size of heatsink To ensure operation of the power module, it is necessary to keep baseplate temperature within the allowable temperature limit. The heat dissipation structure (the size of the heat sink and presence/absence of the fan etc.) also has an influence on the exterior and dimension of the equipment, and designing in advance is important. Eventually, measuring the temperature with the actual application is required. How much air volume is necessary? Is it possible to use without a fan? Fig.1 About heat radiation design of power modules

①Baseplate Temperature  The power module is designed for using within the derating curve shown in Figure 2. For example, in the CBS series, the maximum temperature of baseplate at 100% load is 85℃ and should not exceed the derating curve. Fig.2 Derating curves by the aluminum base plate temperature

②Efficiency of Power Supply and Dissipation power Not all of the input power is converted to output power, and some loss is dissipated as heat from the power module. To determine the internal power dissipation, 1 - 2 % margin of the efficiency shall be considered to select sufficient heatsink. Efficiency is defined as the percentage of Output power vs Input power. Efficiency (E) depends on the input voltage and output current. Refer to the TEST DATA. Fig.3  Power supply efficiency and Dissipation power

③ Thermal resistance In most applications, heat will be conducted from the baseplate into an attached heat sink. The thermal resistance of heatsink shall be designed so that junction temperature becomes less than rated temperature by thermal calculation. As shown in Fig.4, the heat dissipation and heatsink can be modeled as a thermal circuit. Contact thermal resistance is between baseplate and heat sink. To decrease the contact thermal resistance, please use thermal grease (low thermal resistance (0.2 - 0.3℃/W). The thermal grease shall apply to the baseplate thinly and uniformly.. Fig.4  Model of thermal resistance

④Heat sink mounting The interface of the baseplate and heat sink is smooth, flat and free of debris. If the heatsink and the baseplate aren't contacted sufficiently, contact thermal resistance would increase and heat radiation becomes insufficient. Either thermal grease or thermal pads shall be used for sufficient thermal conduction. To install the heat sink, screws shall be tightened at all four mounting holes. When mounting heat sinks to modules, screws shall be tightened uniform torque. The following tightening order should be applied. Please tighten the screw under the maximum torque. Fig.5 Heat sink mounting Fig.6  Tightening order

⑤Installation of modules Mount the module not to block airflow for other modules Use a heat sink with vertical fins along the natural convection. Avoid blocking the airflow to the modules with other components. Fig.7  Installation of modules

Thermal design example The following process describes thermal design with an example of CBS504805.

Thermal design example Fig.10 Fig.9 F-CBS-F1 (external view) Fig.10 Heat sink thermal resistance curves

Thermal design example

Thermal design example The following process describes thermal design with an example of TUNS700F28.

Thermal design example Cutting dimension (℃/W) H = 50㎜ Thermal resistance wind velocity (m/s) Fig.12 50WC240-L200T4P27 (Sankyo Thermo-Tech,lnc.) Fig.13 Heat sink thermal resistance curves

Thermal design example

Thermal design example Fig.14 Heat sink mounting of CBS504805 Fig.15 Heat sink mounting of TUNS700F48 High power module power supply requires a large heat sink as the internal loss increases.