Irradiated Components

Slides:



Advertisements
Similar presentations
HB2008 Aug. 26, 2008 Beam loss monitoring using proportional counters at J-PARC T. Toyama, K. Satou, S. Lee, A. Akiyama, Y. Hashimoto, N. Hayashi, H. Nakagawa.
Advertisements

Slide 1 Irradiation Study of Single Crystal Diamond Sensors for the PLT Irradiation of sensors at the PS 1.5 years ago Comparison to RD42 irradiated poly.
G2p Safety Readiness Review January 17, 2012 Expected Radiation Exposure Levels from Activated Local Dump George Kharashvili, Radiation Control.
BLM thresholds for MQW magnets V. Raginel, B. Auchmann, D. Wollmann BLM Threshold Working Group meeting, 24/02/2015.
LECC 2006 Ewald Effinger AB-BI-BL The LHC beam loss monitoring system’s data acquisition card Ewald Effinger AB-BI-BL.
TS-LEA, CERN, 1211 Geneva 23 1 T. Wijnands TS/LEA, C. Pignard AB-CORADWG-RADMON day – 1 December 2004 LHC Power Converters & Radiation T. Wijnands TS/LEA.
R2E Weekly Report status AT/MB/MC – 4 th R2E Project Meeting – 7 th April 2011.
Oliver Bitterling  Introduction to the QPS  Radiation damage in electronic systems  Construction of radiation tolerant systems  Radiation test and.
Background Issues: Real Time Radiation Measurement S.M.Yang EPC.IHEP Mini-Workshop on BEPCII Background Study March 2008 Institute of High Energy.
BIW May 2004 LHCSILSystemsBLMSSoftwareResults Reliability of BLMS for the LHC. G.Guaglio, B Dehning, C. Santoni 1/15 Reliability of Beam Loss Monitors.
FIPDiag PSI Radiation test Presentation Radwg meeting August 2011 Julien Palluel BE/CO/FE 1 1.Devices Under test 2.Description of the test setup 3.Beam.
Radiation Tolerant Electronics New Policy? Ph. Farthouat, CERN.
CVD Diamond Sensor Studies for the Beam Calorimeter of the ILC Detector K. Afanaciev 2, I.Emelianchik 2, Ch. Grah 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann.
JgimenoIWM-12/1/2004 Fiber Optic module 1 STUDIES AND DEVELOPMENT OF A FIRST FIBER OPTIC MODULE PROTOTYPE Javier Gimeno Vicente.
Radiation Tolerant Electronics Expected changes Ph. Farthouat, CERN.
BLM AUDIT 2010Ewald Effinger BE-BI-BL BLM tunnel installation and data acquisition card (BLECF) Ewald Effinger AB-BI-BL.
FIBER OPTIC TRANSMISSION
LHC Beam Loss Monitors, B.Dehning 1/15 LHC Beam loss Monitors Loss monitor specifications Radiation tolerant Electronics Ionisation chamber development.
M.Moll, M.Silari, H.Vincke – 3.April Feedback  In total 134 forms filled:
Numerical signal processing for LVDT reading based on rad tol components Salvatore Danzeca Ph.D. STUDENT (CERN EN/STI/ECE ) Students’ coffee meeting 1/3/2012.
Update on radiation estimates for the CLIC Main and Drive beams Sophie Mallows, Thomas Otto CLIC OMPWG.
M.Moll, M.Silari, H.Vincke – 3.April Mixed field irradiation -- Who answered ?  In total 36 forms filled / 34 persons answered: 38% 62% CERN:
Chamonix 2006, B.Dehning 1 Commissioning of Beam Loss Monitors B. Dehning CERN AB/BDI.
Secondary Emission Monitor for very high radiation areas of LHC Daniel Kramer for the BLM team.
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.
Radiation Damage Studies for Si Diode Sensors Subject to MRaD Doses Bruce Schum UC Santa Cruz July
Radiation Damage Studies for Si Diode Sensors Subject to MRaD Doses Bruce Schum UC Santa Cruz June
Radiation 4-5 December 2005 AB/BDI/BL.
LHC Radiation Day, B. Dehning1 Beam Loss Monitors B. Dehning.
1 Single event upset test of the voltage limiter for the ATLAS Semiconductor tracker TSL Experiment Number: F151 distance between power supplies and modules.
BLM System R2E and Availability Workshop, B.Dehning 1 Bernd Dehning CERN BE-BI
16 December 2005 IntroductionIntroduction System Layout Dependable Design Dependability Analysis Sensitivity ConclusionsSystem LayoutDependable DesignDependability.
NMLTA Protection System Update -Loss Monitors- Arden Warner September 2 nd, 2009.
Results of the 2007 BLM hardware tests in LSS5
ProtoDUNE SP – Slow control temperature gradient monitor
DerivFIP – Radiation test
Belle-II VXD radiation monitoring and beam abort with sCVD diamond sensors Lorenzo Vitale, Belle-II SVD collaboration INFN and Univ. Trieste, ITALY Requirements.
HEC I chip design Short summary (J.Bán).
Quantum noise reduction using squeezed states in LIGO
Radiation monitoring and follow up during LHC commissioning
Plans for Radiation Damage Studies for Si Diode Sensors Subject to 1 GRaD Doses SLAC Testbeam Workshop March
Next generation rad-hard links
MATerials Research: Topics and Activities
Beam Loss: New Developments, Detectors and Electronics
Injection region BLMs – ECR
Beam Loss Monitors and Ion Chambers for protecting Hall Equipment Tommy Michaelides (SSG) Stay Treat 2016.
Radiation Damage Studies for Solid State Sensors Subject to Mrad Doses
TI8/WIC Incident & UJ87/UA87 Radiation Levels & Analysis
Beam Loss Monitor System Reliability and False Signals
LHC BLM system: system overview
Radiation Damage Studies for Solid State Sensors Subject to MRaD Doses
Remote setting of LHC BLM thresholds?
Direct Dump Tests Modify
A New OEO Design Using Optical Phase Modulation and Modulation Suppression G. John Dick and Nan Yu Jet Propulsion Laboratory, California Institute of Technology.
LHC Radiation Day, B. Dehning
Agenda 9:00-10:00 Beam Interlock System Changes Following the 2006 Audit Benjamin Todd 10:00-11:00 Beam Dump System follow-up from the 2008 Audit Jan Uythoven.
CMS ECAL Endcaps: Fluence/Dose (500 fb-1)
BEAM LOSS MONITORS DEPENDABILITY
C.Octavio Domínguez, Humberto Maury Cuna
BLM changes HV software interlock (SIS)
Commissioning of BLM system
Why do BLMs need to know the Quench Levels?
Warm Magnet Thresholds
Commissioning of the Beam Conditions Monitor of the LHCb Experiment at CERN Ch. Ilgner, October 23, 2008 on behalf of the LHCb BCM group at TU Dortmund:
How do elements bond?.
Report on Beam Loss Monitors
Group 5 – ECE 4006: Week 2 Jason Young 5/2/2019.
Activation of the innate immune response may be radioprotective during larval development. Activation of the innate immune response may be radioprotective.
Placement of the LHC BLMIs around TI8 TED (Q9)
Irradiated Components
Presentation transcript:

Irradiated Components SIL Approach Electronic Our Situation Radiations Tests Dump Levels Irradiated Components Component Supplier Name Integral dose (effects after irradiation) Single event (5E8 p/s/cm2) CFC JFET TEMIC J176 70 pA after 500 Gy ( → calibration) +700 pA (dark current) CFC Amplifier BURR-BROWN OPA627 No -800 pA (current into the component) CFC threshold comparator PHILIPS NE521 ~+100 pA (threshold value is lower) CFC monostable 74HCT123 Small Monodirectional Transceiver ITEC TRX03-SX5SC 1oo2 lasers dies at 500 Gy. PDs worsen at 300 Gy, break at 500 Gy. Photodiodes lose ~ 18 dB of sensitivity PHOTONTEC PT7311-31-1 No laser breaks up to 1000 Gy. PDs worsen at 300 Gy, breaks at 430 Gy. Bidirectional Transceiver WBR 03-3SX5SC Lasers die at 400 Gy. Photodiodes don’t break up to 500 Gy PT8X52-31-1 No laser break up to 700 Gy. Photodiodes break at 700 Gy. BLM Dependability. G.Guaglio

SIL Approach Electronic Our Situation Radiations Tests Dump Levels JFET integral dose Increasing of (low) signal for irradiation and integral dose. BLM Dependability. G.Guaglio

JFET Single event Increasing of signal above 1E7 p/cm2/s SIL Approach Electronic Our Situation Radiations Tests Dump Levels JFET Single event Increasing of signal above 1E7 p/cm2/s BLM Dependability. G.Guaglio

Amplifier Single Event SIL Approach Electronic Our Situation Radiations Tests Dump Levels Amplifier Single Event Decreasing of signal above 1E7 p/cm2/s BLM Dependability. G.Guaglio

Comparator Single Event SIL Approach Electronic Our Situation Radiations Tests Dump Levels Comparator Single Event Little increasing of signal above 1E7 p/cm2/s BLM Dependability. G.Guaglio

SIL Approach Electronic Our Situation Radiations Tests Dump Levels AMPL+JFETs General irradiation of Amplifier and JFET brings to signal increasing. BLM Dependability. G.Guaglio

SIL Approach Electronic Our Situation Radiations Tests Dump Levels Single Event Effect For steady state loss we should not see single event effects: fluence on CFC too low. When we will have 5E6 MIP/s/cm2 on CFC, we will have 1 nA of error current. At this fluence there are 476 nA coming from IC (corresponding to losses of 5.6E9 p/m/s @ 450 GeV, 4.2E8 p/m/s @ 7 Tev). Error of 1nA / 476nA = 0.2% at the dump limits: negligible error for the dump levels. BLM Dependability. G.Guaglio