CVD Diamond Sensor Studies for the Beam Calorimeter of the ILC Detector K. Afanaciev 2, I.Emelianchik 2, Ch. Grah 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann.

Similar presentations


Presentation on theme: "CVD Diamond Sensor Studies for the Beam Calorimeter of the ILC Detector K. Afanaciev 2, I.Emelianchik 2, Ch. Grah 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann."— Presentation transcript:

1 CVD Diamond Sensor Studies for the Beam Calorimeter of the ILC Detector K. Afanaciev 2, I.Emelianchik 2, Ch. Grah 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann 1 1 DESY, Zeuthen 2 NCPHEP, Minsk

2 Beam Calorimeter BeamCal: (4-28) mrad fast beam diagnostics detection and measurement of high energetic electrons and photons at very small angles -- e+e+ e-e- Z0Z0 μ-μ- ~ χ0χ0 μ+μ+ ~ ++ χ0χ0 e + e - e + e -   +  -  σ ~ 10 2 fb (SPS1a) σ ~ 10 6 fb

3 Beam Calorimeter Requirements: Diamond/Tungsten sandwich ~15000 e + e - per BX (30 – 60 TeV) ~10 MGy / year for some area => radiation hard material with small Moliere radius ILC bunch: small size high charge -> beamstrahlung : -> high energy deposition in the Beam Cal:

4 pCVD Sensor Measurements Requirements : - stability under irradiation - linearity of response Measurements : Current-Voltage characteristics Charge Collection Efficiency Qmeas/Qcreated = CCD/L Qcreated(MIP) = 36 eh/mm Irradiation tests (up to 100 Gy) Linearity measurements Samples : Fraunhofer IAF, Element Six 12x12 mm 2, 300-900  m & Gate PA discr delay ADC Sr 90 PM1 PM2 diamond scint.

5 pCVD Sensors Irradiation Measurements: ~ 0.15 Gy/h ~ 0.60 Gy/h ~50%

6 Hadronic beam, 3 & 5 GeV ( CERN PS) Fast extraction mode ~10 4 -10 8 / ~10 ns ADC Diamond (+ PA) Scint.+PMT& signal gate pCVD Sensors linearity test: 10 ns 17 s

7 Linearity test wide intensity range: + absolute intensity measurement ( Thermoluminescence dosimetry) relative intensities estimated from PMT’s: ~(1- 600) HV(PMT) intensity L R

8 PMT calibration

9 Back to the testbeam data… HV(PMT) intensity L R + absolute calibration for one of the runs 1 RI = (27.3+/-2.9) 10 3 MIP/cm 2

10 Linearity of diamond response E64 FAP2

11 The covered range : the particle fluence up to 10 7 MIPs per bunch The obtained deviation from a linear response: ~30% - at the level of systematic errors of the fluence calibration Conclusions