Prevention of Accidental Exposures to Patients Undergoing Radiation Therapy INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————

Slides:



Advertisements
Similar presentations
Preventing accidental exposures from new external beam radiation therapy technologies ICRP Publication 112 Task Group: P. Ortiz López (chairman), J.M.
Advertisements

Building a Cradle-to-Grave Approach with Your Design Documentation and Data Denise D. Dion, EduQuest, Inc. and Gina To, Breathe Technologies, Inc.
INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION —————————————————————————————————————— Prevention of Accidental Exposures to Patients Undergoing Radiation.
Configuration Management
IAEA International Atomic Energy Agency Module 3.3: Incidents in any clinic IAEA Training Course.
بسم الله الرحمن الرحيم ﴿و قل رب زدنى علماً﴾ صدق الله العظيم.
The Therac-25: A Software Fatal Failure
RADIOTHERAPY ACCIDENT IN COSTA RICA - CAUSE AND PREVENTION OF RADIATION ACCIDENTS IN HOSPITALS Module XIX.
PERTEMUAN - 2 SOFTWARE QUALITY. OBJECTIVES After completing this chapter, you will be able to: ■ Define software, software quality and software quality.
IAEA International Atomic Energy Agency Responsibility for Radiation Safety Day 8 – Lecture 4.
©Ian Sommerville 2004Software Engineering, 7th edition. Chapter 20 Slide 1 Critical systems development.
INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION —————————————————————————————————————— Interventional Procedures – Avoiding Radiation Injuries.
IAEA International Atomic Energy Agency Module 2.2: Erroneous use of TPS (UK) IAEA Training Course.
CSCU 411 Software Engineering Chapter 2 Introduction to Software Engineering Management.
Overview Lesson 10,11 - Software Quality Assurance
(c) 2007 Mauro Pezzè & Michal Young Ch 1, slide 1 Software Test and Analysis in a Nutshell.
Gauges and well logging
Quality Assurance: Manufacturer & Clinical Aspects  Alan Cohen, M.S. DABR  Paul Naine, MSc. MIPEM  Jim Schewe, PhD, DABMP Accuray Incorporated Elekta.
Accidents in Radiotherapy
IAEA International Atomic Energy Agency PREVENTION OF ACCIDENTAL EXPOSURE IN RADIOTHERAPY Part 3: Analysis of causes and contributing factors IAEA Training.
Radiation Protection in Radiotherapy
Short Course on Introduction to Meteorological Instrumentation and Observations Techniques QA and QC Procedures Short Course on Introduction to Meteorological.
Software Quality Assurance
IAEA International Atomic Energy Agency International Reporting Systems Ola Holmberg, PhD Head, Radiation Protection of Patients Unit Radiation Safety.
Protection Against Occupational Exposure
Radiotherapy for Kidney cancer
Unit #7 - Basic Quality Control for the Clinical Laboratory
Software Dependability CIS 376 Bruce R. Maxim UM-Dearborn.
 Quality & Safety Considerationsin Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy.
Quality Assurance for a modern treatment planning system
IAEA International Atomic Energy Agency PREVENTION OF ACCIDENTAL EXPOSURE IN RADIOTHERAPY Part 5: Reporting, investigating and preventing accidental exposures.
IAEA International Atomic Energy Agency Module 2.7: Error in TPS data entry (Panama) IAEA Training Course.
Event Management & ITIL V3
This chapter is extracted from Sommerville’s slides. Text book chapter
IAEA International Atomic Energy Agency Module 3.2: Other cases (brachytherapy) IAEA Training Course.
FDA Public Meeting: Device Improvements to Reduce the Number of Under-doses and Misaligned Exposures from Therapeutic Radiation.
IN THE NAME OF GOD Quality Assurance and Blood Bank S. AMINI KAFI ABAD CLINICAL AND ANATOMICAL PATHOLOGIST IRANIAN BLOOD TRANSFUSION ORGANIZATION(IBTO)
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Inspection Part II.
Prime Responsibility for Radiation Safety
Institute for Advanced Radiation Oncology
Ergonomics Regulatory Requirements Bawan Saravanabawan, Labour Program, HRSDC February 4, 2008.
IAEA International Atomic Energy Agency Module 2.6: Miscalibration of beam (Costa Rica) IAEA Training Course.
IAEA International Atomic Energy Agency Safety Reports Series No. 7 Lessons Learned from Accidents in Industrial Radiography Practical Radiation Safety.
Programme Performance Criteria. Regulatory Authority Objectives To identify criteria against which the status of each element of the regulatory programme.
Configuration Management and Change Control Change is inevitable! So it has to be planned for and managed.
Biological Effects of Ionizing Radiation Deterministic effects
Software Quality Assurance and Testing Fazal Rehman Shamil.
Part VIII:Medical Exposures in Radiotherapy Lecture 2 : Scope and Responsibilities – Training of staff IAEA Post Graduate Educational Course on Radiation.
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Program Performance Criteria.
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Need for a Regulatory program.
IAEA International Atomic Energy Agency PREVENTION OF ACCIDENTAL EXPOSURE IN RADIOTHERAPY Part 1: Review of International Basic Safety Standards (BSS)
Dr. Kęstutis Adamonis, Dr. Romanas Zykus,
Configuration Management
Radiological Protection in Ion Beam Radiotherapy
Unit #6 - Basic Quality Control for the Clinical Laboratory
IAEA E-learning Program
IAEA E-learning Program
Quality Assurance in the clinical laboratory
Sharan Packer Specialist Inspector (Radiation)
IAEA E-learning Program
Configuration Management
IAEA E-learning Program
IAEA E-learning Program
IAEA E-learning Program
Flooding Walkdown Guidance
Regulatory Oversight of HOF in Finland
Chapter 13 Quality Management
11 iii. Define management and supervision roles and responsibilities
Kingdom of Saudi Arabia
Internal Control Internal control is the process designed and affected by owners, management, and other personnel. It is implemented to address business.
Presentation transcript:

Prevention of Accidental Exposures to Patients Undergoing Radiation Therapy INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

International Commission on Radiological Protection Information abstracted from ICRP Publication 86 Available at www.icrp.org Task Group: P. Ortiz, P. Andreo, J-M. Cosset, A. Dutreix, T. Landberg, L.V. Pinillos, W. Yin, P.J.Biggs INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Use and disclaimer This is a PowerPoint file It may be downloaded free of charge It is intended for teaching and not for commercial purposes This slide set is intended to be used with the complete text provided in ICRP Publication 86 INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Contents Case histories of major accidental exposure in radiotherapy Clinical consequences of accidental exposures Recommendations for prevention INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Case Histories of Major Accidental Exposures of Patients in Radiotherapy INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Case 1: Use of an incorrect decay curve for 60Co (USA, 1974-76) Initial calibration of a 60Co beam was correct, but .. A decay curve for 60Co was drawn: by mistake, the slope was steeper than the real decay and the curve underestimated the dose rate Treatment times based on it were longer than appropriate, thus leading to overdoses, which increased with time reaching up to 50% when the error was discovered There were no beam measurements in 22 months and a total of 426 patients affected Of the 183 patients who survived one year 34% had severe complications INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Case 2: Incomplete understanding & testing of a treatment planning system (TPS) (UK, 1982-90) In a hospital, most of the treatments were with a SSD of 100 cm For treatments treatments with SSD different from standard (100 cm), corrections for distance were usually done by the technologists When a TPS was acquired, technologists continued to apply manual distance correction, without realising that the TPS algorithm already accounted for distance INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Cont’d: Incomplete understanding and testing of a treatment planning system (UK, 1982-1990) As a result, distance correction was applied twice, leading to underdosage (up to 30%) The procedure was not written, and therefore, it was not modified when new TPS was used Problem remained undiscovered during eight years and affected 1,045 patients 492 patients who developed local recurrence probably due to the underexposure INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Case 3: Untested change of procedure for data entry into TPS (Panama, 2000) A TPS allowed entry of four shielding blocks for isodose calculations, one block at a time Need for five shielding blocks led to deviation from standard procedure for block data entry: several blocks were entered in one step Instructions for users had some ambiguity with respect to shielding block data entry TPS computer calculated treatment time, which was double the normal one (leading to 100% overdose) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Cont’d: Untested change of procedure for data entry into TPS (Panama, 2000) There was no written procedure for the use of TPS, and therefore, a change of procedure was neither written nor tested for validity Computer output was not checked for treatment time with manual calculations The error affected 28 patients One year after the event, at least five had died from the overexposure INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Case 3: Patient treated with overdose Colonoscopy of a patient treated with overdoses of 100% Necrotic tissue Telangiectasia Ulceration and necrosis INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Case 4: Accelerator software problems (USA & Canada, 1985-87) Software from an older accelerator design was used for a new, substantially different, design Software flaws were later identified in the software used to enter treatment parameters, such as type of radiation and energy Six accidental exposures occurred in different hospitals and three patients died from overexposure INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Case 5: Reuse of outdated computer file for 60Co treatments (USA, 1987-88) After source change, TPS computer files were updated… Except a computer file, which was no longer in use (this was intended for brain treatments with trimmer bars) The computer file was not removed although no longer in use INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Cont’d: Reuse of outdated computer file for 60Co treatments (USA, 1987-88) A new radiation oncologist decided to treat with trimmer bars and took the file corresponding to the prior 60Co source There was no double or manual check for dose calculation 33 patients received 75% higher overexposure INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Case 6: Incorrect accelerator repair & communication problems (Spain, 1990) Accelerator fault followed by an attempt to repair it Electron beam was restored but electron energy was misadjusted Accelerator delivered 36 MeV electrons, regardless of energy selected Treatments resumed without notifying physicists for beam checks INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Cont’d: Incorrect accelerator repair & communication problems (Spain, 1990) There was a discrepancy between energy displayed and energy selected, which was attributed to a faulty indicator, instead of investigating the reason for the discrepancy A total of 27 patients were affected with massive overdoses and by distorted dose distribution due to wrong electron energy At least 15 of these patients died from the accidental overexposure and two more died with overexposure as major contributor INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Case 7: Malfunction of HDR brachytherapy equipment (USA, 1992) HDR brachytherapy source detached from the driving mechanism while still inside the patient While the console display indicated that the source was in retracted to the shielded position, an external radiation monitor was indicating that there was radiation Staff failed to investigate the discrepancy with available portable monitor The source remained in the patient for several days and the patient died from overexposure INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Case 8: Beam miscalibration of 60Co (Costa Rica, 1996) Radioactive source of a teletherapy unit was exchanged During beam calibration, reading of the timer was confused, leading to underestimation of the dose rate Subsequent treatment times were calculated with the wrong dose rate and were about 60% longer than required 115 patients were affected; two years after the event, at least 17 patients had died from the overexposure INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Case 8: Beam miscalibration of 60Co (Costa Rica, 1996) Failure to perform independent calibration Failure to notice that treatment times were too long for a new source with higher activity Child affected by overdoses to brain and spinal cord and lost his ability to speak and walk INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Clinical Consequences INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Side effects and complications in radiotherapy Side effects are usually minor and transient e.g : xerostomia and localised subcutaneous fibrosis Relatively high frequency acceptable to achieve cure Complications are more severe and long lasting e.g : radiation myelitis Expected only at very low frequency INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Impact of accidental underexposure Accidental underdosage may jeopardise tumour control probability They are difficult to discover, may only be detected after relatively long time and, therefore, may involve a large number of patients INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Impact of overdoses on early (or acute) complications Usually observed in tissues with rapid cell turnover (skin, mucosa, bone marrow …) Overexposure may increase the frequency and severity (up to necrosis) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Early (acute) complications Determinant factors for acute complications are: 1) total delivered dose 2) total duration (protraction) 3) size and location of irradiated volume Little correlation of early complications with fraction size and dose rate (except if the latter is very high) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Late complications Mainly observed in tissues with slowly proliferating cells (arteriolar narrowing which occurs with a time delay) Can also become manifest in rapidly proliferating cells (in addition to and after acute effects) Manifest more than six months after irradiation and even much later Usually irreversible and often slowly progressive INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Example of late complications due to an accidental overexposure… Extensive fibrosis of the left groin with limitation of hip motion as a result of accidental overexposure INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Impact of overexposure on late complications (cont’d) Determinant factors: 1) total delivered dose 2) fraction size and dose rate In the case of accidental exposure, increased fraction size may amplify the effects (as occurred in some accidents) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Late complications (cont’d) In serial organs (spinal cord, intestine, large arteries), a lesion of small volume irradiated above threshold may cause major incapacity, for example paralysis In organs arranged in parallel (e.g. lung and liver), severity is related to the tissue volume irradiated above threshold Organs with serial arrangement (example spinal cord) Organs with parallel arrangement (example, liver) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Example of late complication on organ with serial arrangement (spinal cord) Young woman who became quadri-plegic as a result of accidental over-exposure to the spinal cord INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Clinical detection of accidental medical exposure Careful clinical follow-up may lead to detect accidental overdose through early enhanced reactions Experienced radiation oncologists can detect overdoses of 10 % during regular weekly consultations Some overdoses may cause late severe effects without abnormal early effects INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Clinical detection of accidental medical exposure (cont’d) In the case of unusual reactions in a single patient, other patients treated in the same period may need to be recalled INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Recommendations for Prevention INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

List of Recommendations for prevention Overall preventive measure: a Quality Assurance Programme, involving Organisation Education and training Acceptance testing and commissioning Follow-up of equipment faults Communication Patient identification and patient charts Specific recommendations for teletherapy Specific recommendations for brachytherapy INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Quality Assurance Programme for Radiation Therapy (QART) Quality assurance programmes have evolved from equipment verifications to include the entire process, from the prescription to delivery and post treatment follow-up Major accidental exposures occurred in the absence of written procedures and checks (QART); either because a QART did not exist or it was not fully implemented (checks omitted) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Organisation Comprehensive QA is crucial in prevention and involve clinical, physical and safety components: Its implementation requires complex multi-professional team work clear allocation of functions and responsibilities functions and responsibilities understood number of qualified staff, commensurate to workload INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Education and training The most important component of QA is qualified personnel, including radiation oncologists, medical physicists, technologists and maintenance engineers Comprehensive education together with specific training on procedures and responsibilities everyone’s role in the QART programme lessons from typical accidents with a description of methods for prevention additional training when new equipment and techniques are being introduced INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Acceptance testing & commissioning Errors in these phases may affect many patients Acceptance testing: Should include test of safety interlocks, verification of equipment specifications, as well as understanding and testing TPS Commissioning: Should includes measuring and entering all basic data for future treatments into computer Systematic acceptance and commissioning, including a cross check and independent verification, form a major part of accident prevention INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Follow-up on equipment faults Experience has shown that some equipment faults are difficult to isolate and to correct If an equipment fault or malfunction has not been fully understood and corrected, there is a need for communication and follow-up with manufacturer dissemination of information and experience to other maintenance engineers INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Communication and repairs Need for a written communication policy, including: Reporting of unusual equipment behaviour Notification to the physicist and clearance by before resuming treatments (because of possible need for control checks after repairs) Reporting of unusual patient reactions INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Patient identification and patient chart Effective patient identification procedures and treatment charts (consideration of photographs for identification …) Double check of chart data at the beginning of treatment, before changes in the course of treatment (for example, a new field) and once a week at least INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Specific items for external beam therapy Calibration Provisions for initial beam calibration and follow-up calibrations Independent verification of the calibration Following an accepted protocol Participation in dose quality audits Treatment planning Include TPS in the programme of acceptance testing commissioning and quality assurance Cross-checks and manual verification Adequate in-vivo dosimetry would prevent most accidental exposures INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Specific items for brachytherapy Provisions for checking source activity and source identification before use Dose calculation and treatment planning Provisions for dose calculation and cross-checks Source positioning and source removal Provisions to verify source position Provisions to ensure that sources do not remain in the patient (including monitoring patients and clothes) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Summary Radiotherapy has unique features from the point of view of the potential for accidental exposure Consequences of accidental exposure can be very severe and affect many patients Careful clinical follow up may detect overdoses from about 10% A quality assurance programme is the key element in prevention of accidental exposure INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————  

Web sites for additional information on radiation sources and effects European Commission (radiological protection pages): europa.eu.int/comm/environment/radprot International Atomic Energy Agency: www.iaea.org International Commission on Radiological Protection: www.icrp.org United Nations Scientific Committee on the Effects of Atomic Radiation: www.unscear.org World Health Organization: www.who.int INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION ——————————————————————————————————————