IPES-IR3 Flame Sensor By Tim Quine ENGR 518. Purpose Detect fires in industrial applications such as refineries, paint productions, oil and gas boilers.

Slides:



Advertisements
Similar presentations
RS232 and RS485 Fundamental.
Advertisements

PV String Monitoring Solution
P f a n n e n b e r g Group © Since 2008 company Pfannenberg introduced a new Range of Alarming Products, as so called Marine Range. The main characteristic.
1 INTRODUCTION TO ELECTRICAL THEORY 2 What is Electricity? The controlled flow of electrons in an electrical circuit. A circuit must always be a complete.
and 6.855J Cycle Canceling Algorithm. 2 A minimum cost flow problem , $4 20, $1 20, $2 25, $2 25, $5 20, $6 30, $
PT. GlobalNine Indonesia, Niaga Kalimas Blok-A No.5 Bekasi Timur, Bekasi Phone: / Fax , Web: PRESENTED.
Sequential Process Control
INTRUSION ALARM TECHNOLOGY
Click left mouse button to advance, back to return Refrigeration HVAC control & monitor system Presscon Network & Pressnet Software Click left mouse button.
3G Monitor. 3G Camera Contents 3G camera Function Features 3G Camera's Application Scenes 3G camera's business mode 3G Camera Technical parameters.
Mehdi Naghavi Spring 1386 Operating Systems Mehdi Naghavi Spring 1386.
Wireless Controllers. Building block for remote control & alarming Functions Local control Measurement SMS alarming Remote control via SMS Data transmission.
HWg-Juno HW group is a manufacturer of IP-based sensors from Prague, Czech republic. HWg delivers remote monitoring & control solutions.
Modern Ethernet UTP and Fiber Optic Cable-based Ethernet
AUTO SELECTION OF ANY AVAILABLE PHASE,
Transducers PHYS3360/AEP3630 Lecture 33.
MEMS Thermal & Fluid Control Lab. RFID tag powered by solar cell was set up and integrated with multiple sensors, such as temperature, humidity, light.
14-4 Rev. A Sept. 18, 2007 Fire Detection System Model S64F Helicopter.
Open-Path Gas Detection - Philosophy of Use or The Story of Clouds.
… for Combustible Gas Detection S4000C Intelligent Sensors..
Sensor Operating Theory
CONTROL VISION Set-up. Step 1 Step 2 Step 3 Step 5 Step 4.
True or False? 20 questions. Question 1 Sound is a transverse wave.
Practical Considerations for Digital Design
Nokia 30 technical specification
Autonomous Control of a Scalextric Slot Car on a User-Defined Track Siddharth Kamath Souma Mondal Dhaval Patel School of Electrical and Computer Engineering.
Restricted © Siemens AG 2013siemens.com/answers Flexible fire protection engineered for data centers Very Early Warning Detection Systems & Technologies.
Programming Logic Controllers
GS3055-I GSM Universal Wireless Alarm Communicator

E VERY L IFE H AS A P URPOSE… Flame Detection Theory.
Protecting life, environment and property... 1 Flame Detection Design: A Balancing Act Detection Capability Range Fuel Interference Rejection Resistance.
EML 2023 – Motor Control Lecture 4 – DAQ and Motor Controller.
E VERY L IFE H AS A P URPOSE… FlameGard 5 UV/IR Flame Detector The Benefits of HART on Installation and Maintenance of Flame Detectors.
EUT 1040 Lecture 10: Programmable Logic Controllers.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
IR Object Detection living with the lab IR light from LED IR light reflected off object IR LED IR receiver Infrared (IR) light leaving an LED reflects.
Gas Sensor and Transmitter
Ultima® X Series Gas Monitors
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
Thermal imaging and SMS alert for farmers Ninad Mehendale.
SCADA and Telemetry Presented By:.
Fire Detection Presentation
Benefit and advantages using Iris conventional detectors range.
Open and Closed Loops Standard Grade Computing Studies.
1 Applied Control Systems Technology. 2 Pin configuration Applied Control Systems.
Engineer Training Motion Control TJ8300 / TJ8500 Motion Control.
U-GAGE ® T30UX Series Ultrasonic Sensor with TEACH-Mode Configuration.
COMPONENTS REQUIRED STEP DOWN PRANSFORMER:
An Introduction to the R3 19 inch Rack The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
GS3055-I GSM Universal Wireless Alarm Communicator
E VERY L IFE H AS A P URPOSE… FlameGard 5 MSIR Flame Detector.
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Europe & Africa More Than.
Prepared by: Engr. Qurban Ali Memon 11ES (SEC- 1 & 2)
Scanner  We can use it to convert printed images or docs into a digital format.  After obtaining a digital image we can make some modifications it on.
EE 4BD4 Lecture 14 Position Sensors 1. Types of Sensors Potentiometers and linear resistors Capacitive sensors (mm distances, e.g. capacitive microphone)
Infrared IR Sensor Circuit Diagram and Working Principle.
IR Object Detection living with the lab IR light from LED IR light reflected off object IR LED IR receiver Infrared (IR) light leaving an LED reflects.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
GmbH Specialist hotel application ComplianceCommercial refrigeration Industrial refrigeration Light Industrial Gas Detection MGS-550 Product Portfolio.
Hearty Welcome!.
Light Detection Circuit
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
Input-Output-Process Demo
TD-1235 Loop Group Multiplexer
Presentation transcript:

IPES-IR3 Flame Sensor By Tim Quine ENGR 518

Purpose Detect fires in industrial applications such as refineries, paint productions, oil and gas boilers. Send alarm signals to users receiving devices or alarm systems. This is done via closed loop current signals.

Device Characteristics Enclosure Material – Stainless Steel Grade 316 or Aluminum 6061 Weight – Stainless Steel 11 lbs. or Aluminum 5.5 lbs. Cable – 6,200 ft. (18 AWG)

Device Components IR Detectors LED Status Lights Explosive Proof Casing

Differential Signaling Lesson RS232RS423RS422RS485 Differentialno yes Max number of drivers11132 Max number of receivers Modes of operation half duplex full duplex half duplex Network topologypoint-to-pointmultidrop multipoint Max distance (acc. standard)15 m1200 m Max speed at 12 m20 kbs100 kbs10 Mbs35 Mbs Max speed at 1200 m(1 kbs)1 kbs100 kbs Max slew rate30 V/μsadjustablen/a Receiver input resistance3..7 k 4 k 12 k Driver load impedance3..7 k Receiver input sensitivity ±3 V±200 mV Receiver input range ±15 V±12 V±10 V –7..12 V Max driver output voltage ±25 V±6 V –7..12 V Min driver output voltage (with load)±5 V±3.6 V±2.0 V±1.5 V

Device Specifications

Square Law and Wavelengths

Signaling Outputs – Industry Standard 4-20 mA +/- 0.1 mA, 2 alarm relays, digital and analog. StateIR3 Status Fire Relay StateFault Relay Status Output signal, mA LED Status Condition Normally open when energized Normally closed when energized 1 No power supply voltageOpen 0Off 2 After switching on during 45 sec. Open 2 Continuous green LED light for first 10 sec, then flashing green LED 3 Fault or optical interference (dust)Open 2 Alternate flashing of the yellow and green LED lights 4 Normal (no faults or fire during operation)OpenClosed4 Continuous lighting of the green LED light 5FireClosed 18Continuous red LED light 6 Fire & Fault ClosedOpen8 Alternate flashing of the yellow and green LED light 7 Test mode (magnetic collar is on)Open 2 Magnetic collar is on. Fire relay is blocked

Sensitivity FuelDistanceFire SizeAvg. Time N-Heptane2111 ft x 1 ft9 sec Methanol1511 ft x 1 ft9 sec Ethanol1511 ft x 1 ft11 sec Diesel1511 ft x 1 ft15 sec Diesel1512 ft x 2 ft10 sec Gasoline1751 ft x 1 ft10 sec JP ft x 1 ft10 sec JP ft x 2 ft10 sec Methane1513/8 x 310 sec Stimuli modulated at 1.5 Hz and also un-modulated Field of vision

Probability Review Times 9 sec 11 sec 15 sec 10 sec

False Alarms Cost industries money due to down time. Must know difference or the result could be catastrophic. Uses microprocessor, algorithms, multiple sensors and wavelength range settings.

Competitors Technologies Bimetal thermal switches Computer Imaging Programs Smoke detectors SAFE air sample analysis

My Future Uses Compressed Air Foam System Small scale flame sensors Detecting all fires

References files/files/IPES-IR3rep-WEB pdfhttp:// files/files/IPES-IR3rep-WEB pdf /files/IPES%20IR3%2003_28_2012.pdfhttp:// /files/IPES%20IR3%2003_28_2012.pdf multi-spectral-flame-detector.phphttp:// multi-spectral-flame-detector.php **All images in powerpoint are from Google Images**

Questions?