Perform Calibration Certification

Slides:



Advertisements
Similar presentations
EPOCH 1000 Series Software Feature AWS D1.1/1.5
Advertisements

EPOCH 1000 Series Procedure Conventional Straight Beam Calibration
EPOCH 1000 Series Procedure Conventional Angle Beam Calibration
HARP-B Local Oscillator
Velleman Arbitrary Function Generator: Windows 7 by Mr. David Fritz
EPOCH 1000 Series Software Update New Features - March 2010.
Crown CDi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
Intermediate Course (4) Transmitters Karl Davies East Kent Radio Society EKRS 1.
© 2002 QxDesign, Inc. Building a PI controller This unit discusses Installation of Visual ModelQ The Visual ModelQ default model Placing and configuring.
Introduction to the Oscilloscope Professor Ahmadi ECE 002.
1 Cathode Ray Oscilloscope Introduction Look and play Read instructions Break into smaller parts Decide on a simple measurement Increase your level of.
Introduction 1st semester King Saud University
Introduction to electronics lab ENGRI 1810 Using: Solderless prototype board (white board) Digital multimeter (DMM) Power Supply Signal Generator Oscilloscope.
EPOCH 1000 Series Procedure Phase Array Straight Beam Calibration
PRINCIPLES OF MEASUREMENT AND INSTRUMENTATION EKT 112
Introduction to the Oscilloscope
1 EE 188L Lab #2 Test Bench Photos. 2 Vout R1 R5 R4 R3 R C2 C1 R7 R6 At this end there will be a cut-out and/or a dot next to pin 1 -15V.
EE311: Junior EE Lab Phase Locked Loop J. Carroll 9/3/02.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
1 Lab #9 AC Circuits Activity #1 – Simulating a Low Pass Circuit Activity #2 – Building & Testing a Low Pass Circuit Activity #3 – Comparison of 3 methods.
The Oscilloscope: Basic Features & Functions  Source –Determines which signal is compared to the trigger settings.  Level –Determines where on the edge.
USE OF THE OSCILLOSCOPE Modified from a presentation written by David Matzke by: Donald Wisniewski, Dawn Wisniewski, Huzefa Mamoola and Angela Nolte Under.
Familiarizing Yourself with the Oscilloscope The Digital Oscilloscope On the oscilloscope at your station identify the following items. In the course of.
1 AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz.
Introduction to the FONIX 7000 Hearing Aid Test System Software version 1.60.
The Function Generator and the Oscilloscope Dr. Len Trombetta 1 ECE 2100.
Oscilloscope Tutorial
 Popular instrument to show time, voltage both DC and AC. Shows Volts / Time.  Display waveforms. Spectrum scope shows volts to Frequency  Cathode (-ve.
Introduction to the Oscilloscope Professor Ahmadi ECE002 George Washington University.
Institute Of Applied Technology ATE 1012 Grade 10 Eng. Rose Hasan.
CHAPTER 9 Oscilloscopes and Graphing Multimeters
Waveform 2.1 Basic Digital Waveforms 2 Measurement Paul Godin Updated October 2009.
General Engineering Polytechnic University Laboratory 9: Electrical Filters.
1 Cathode Ray Oscilloscope Introduction Look and play Look and play Read instructions Read instructions Break into smaller parts Break into smaller parts.
Laboratory Equipment 1 st semester King Saud University College of Applied studies and Community Service 1302CT By: Nour Alhariqi.
Project Work 1Lecture LECTURE 4 Repetitive signals Time varying signals e.g. RS-232 signals Oscilloscope.
Single Ended Measuring Modes of ELQ 30A To learn more click on the selected topic! ELEKTR NIKA Receiving Modes Impulse Noise Measurement Spectrum Analyzer.
EPOCH 1000 Series Procedure Linear Scan and C-scan.

Oscilloscope Muhajir Ab. Rahim School of Mechatronic Engineering
Vertical deflection system: * The function of the deflection system provides an amplified signal of the proper level to derive the vertical deflection.
Analog Discovery Arbitrary Function Generator for Windows 7 by Mr
Scopes  An oscilloscope is a visual voltmeter.  An oscilloscope converts electrical signals into a visual image representing voltage changes over a.
Laboratory 9: Electronic Filters. Overview Objectives Background Materials Procedure Report / Presentation Closing.
EPOCH 1000 Series Procedure Phased Array Angle Beam Calibration
Introduction to the Oscilloscope Professor Ahmadi ECE 002.
Generator Frequency Knob Frequency display Frequency Range Output Amplitude (output Level) Knob -20 db (output attenuate) Functions.
Laboratory 10: Electronic Filters. Overview  Objectives  Background  Materials  Procedure  Report / Presentation  Closing.
Velleman Oscilloscope: Windows 7 by Mr. David Fritz.
The University of Texas at Arlington Electrical Engineering Department
Lecture 5: DMM & Oscilloscope 1. DMM can be used to measure: DC & AC voltages – current - resistance - BJT (β test) - diode test - short circuit test,
EPOCH 1000 Series Procedure Phased Array DAC/TVG.
BASIC INSTRUMENTS - oscilloscopes
1 Phase Angle Measurement Using the Oscilloscope This procedure measures the phase angle difference between two sinusoidal waveforms connected to channels.
SPM Users Basic Training August 2010 Lecture VIII – AC Imaging Modes: ACAFM and MAC Imaging methods using oscillating cantilevers.
By. Jadhav Avinash J Roll no - 2K13E11. Reference: Hewlett Packard Agilent Technology Wikipedia GwINSTEK.
The Function Generator and the Oscilloscope Dr. Len Trombetta and Dr. Dave Shattuck 1 ECE 2100.
Oscilloscopes. Objectives –After completing this chapter, the student should be able to: Explain the function of an oscilloscope. Identify the basic parts.
National Highway Institute 5-1 REV-2, JAN 2006 EQUIPMENT FACTORS AFFECTING INERTIAL PROFILER MEASUREMENTS BLOCK 5.
Residential Cabling Technologies Copyright © 2005 Heathkit Company, Inc. All Rights Reserved Electrical Measurements.
Cathode Ray Oscilloscope Introduction
Cathode Ray Oscilloscope Introduction
(5) DMM & Oscilloscope.
Oscilloscope.
Cathode Ray Oscilloscope Introduction
Introduction to the Oscilloscope
McCrometer Nano Board Test Procedure
Oscilloscopes HP 54600B Digital Oscilloscope Alex Jones COE 0501.
Lab 8 Induction to Oscilloscope
Automotive Technology Principles, Diagnosis, and Service
Presentation transcript:

Perform Calibration Certification on Your Own Eddy Current Instrument without Costly Shipments and Down Time ! P.O. Box 44926, Tacoma, WA 98444 Tel: (253) 841-2939 / Fax: (253) 841-3016 www.vmproducts.net * sales@vmproducts.net VM Products, Inc. Specialists in Eddy Current Probes, Reference Standards, Applications, Research & Development

Is the screen display showing you a true representation of the defect? Are you sure the inspection results you obtain from your Eddy Current Instrument are accurate? Is your instrument actually performing at the frequency you have selected? Is the screen display showing you a true representation of the defect? Now, you can Measure and Verify your Eddy Current Instrument Calibration. The VMGTB-100 Gain Test Box system will Verify: Internal Oscillator Frequency Internal Oscillator Amplitude Receiver Amplification Gain Receiver Linearity Receiver Stability Alarms

The military does not presently require periodic certification of eddy current instrument calibration. Instruments not working properly could possibly be used for critical inspections. This is not the case in the commercial aviation sector. The FAA does require periodic certification of instrument calibration.

This presents the problem of taking the instrument out of service for the period of time it takes to send it in for calibration. This also creates another expense for the operator. This procedure together with the normal calibration using a certified reference standard before performing an inspection, will ensure the integrity of the instrument for the job.

This Calibration Verification procedure can be divided into two parts. Part # 1 Internal Oscillator Output The internal oscillator provides the signal to the probe and has to meet frequency and amplitude requirements. Part # 2 Receiver (Detection and Amplification) The probe signals are processed by electronic circuits such as detectors and amplifiers, before they are sent to the display. The Gain and Linearity of this part of the instrument needs to be tested.

This verification method follows the guidelines set forth in Section 5 This verification method follows the guidelines set forth in Section 5.2.2 Instrument Calibration/Certification of: Boeing Specification Support Standard - BSS 7048, Eddy Current Inspection, Discontinuities. This method for eddy current instrument certification has been in satisfactory operation at the Boeing Metrology Laboratory for over 7 years and has been acceptable to the FAA.

This presentation will feature the Nortec 2000D Eddy Current Instrument as an example. Required Equipment will include: Standard Oscilloscope with a minimum of 20 MHz bandwidth & 10 mVolt sensitivity Frequency Counter with a minimum range of 100Hz - 2MHz Gain Test Box – VMGTB-100 Adapter Cable – VM99L16-102F Lemo 16-pin to Fischer Triaxial adapter VM99BB2 BNC to BNC Cable, 2 Ft. long We have selected the Fluke 123 Scopemeter because it incorporates the Oscilloscope and Frequency Counter in one small package.

Test Set-Up Attach the VM99L16-102F Adapter Cable to the Nortec 2000D and the VMGTB-100 Gain Test Box. Attach the counter/oscilloscope to the Coil A connector on the test box using the BNC-BNC cable.

Preliminary Set Up for the Fluke 123 Scopemeter Turn Instrument ON Press SCOPE MENU – Select DC & NORMAL under INPUT A, Select DC & OFF under INPUT B. Press the ENTER key. Press SCOPE MENU – Press the F1 key under SCOPE OPTIONS… Select NORMAL for SCOPE MODE and SMOOTH under WAVEFORM MODE. Press the ENTER key. Press SCOPE MENU – Press the F2 key under PROBES… Select PROBE on A. Press the ENTER key. Select 1:1 LEADS under INPUT A. Press the ENTER key. Press SCOPE MENU– Press the F3 key under TRIGGER… Select A under INPUT…Select FREE RUN under SCREEN UPDATE… Select 15Hz under AUTO RANGE. Press the Press the V Hz A key under A. Select Hz and press the Press the V Hz A key. under B. Select OFF and PEAK. Press the ENTER key. Press the mV/V key under A until 1V/d appears in the lower left of the screen. Press the TIME key until 10µs/d appears in the lower left of the screen, next to V/d.

General Set-Up for the Nortec 2000D Eddy Current Instrument Set the FREQ to 100 kHz Set the ANGLE to 92° Set the H-GAIN & V-GAIN to 82.0 dB Set the LP FILTER to 100 Set the HP FILTER to OFF Set the CONT NULL to OFF Set the DISPLAY to SWEEP OFF Set both the V-POS & H-POS to 50.0% Set all ERASE to OFF Set DOT/BOX to DOT Set GRATICULE to ON On SETUP MENU select PROBE DRIVE LOW On SETUP MENU select FREQ SINGLE

Internal Oscillator Frequency Verification BSS 7048 section 5.2.2.2.a. “Internal Oscillator Output” requires that instrument frequency be within ±20% of the indicated value and shall not drift more than ±10% in a 15 minute period. Set the Nortec 2000D to the frequencies listed in the first column of the following table. Adjust the Scopemeter sweep display up or down using the “TIME” button to maintain enough cycles to trigger the readings. Observe the frequency displayed on the Scopemeter display. FREQUENCY ±20% MINIMUM MAXIMUM STABILITY 100 Hz 80 Hz 120 Hz Check (at a frequency of 100 kHz only) that any frequency drift is below 10% during 15 minutes. Pass / Fail 500 Hz 400 Hz 600 Hz 1 kHz 800 Hz 1.2 kHz 5 kHz 4 kHz 6 kHz 10 kHz 8 kHz 12 kHz 50 kHz 40 kHz 60 kHz 100 kHz 80 kHz 120 kHz 500 kHz 400 kHz 600 kHz 1 MHz 800 kHz 1.2 MHz 5 MHz 4 MHz 6 MHz 10 MHz 8 MHz 12 MHz 9.6 MHz 14.4 MHz

Internal Oscillator Amplitude Verification BSS 7048 section 5.2.2.2.a. “Internal Oscillator Output” requires that signal amplitude shall not vary more than ±10% in a 15 minute period or more than ±20% over the calibration period. With frequency set at 100 kHz, measure and record the following peak to peak amplitudes using the oscilloscope (measure the base waveform, disregarding the spikes. These are outside of the frequency band and do not affect the eddy current test). Oscillator Output (PROBE DRIVE) MINIMUM MAXIMUM STABILITY (HIGH) Nominal = 12 Volts 12 Volts – 20% = 9.6 Volts 12 Volts + 20% = 14.4 Volts Check (at a frequency of 100 kHz only) that the amplitude has a variation of less than 10% during 15 minutes. Pass / Fail (MID) Nominal = 6 Volts 6 Volts – 20% = 4.8 Volts 6 Volts + 20% = 7.2 Volts (LOW) Nominal = 2 Volts 2 Volts – 20% = 1.6 Volts 2 Volts + 20% = 2.4 Volts Measure Peak to Peak Voltage X 2 * The voltage on the Scopemeter will read ½ the actual value on the Nortec 2000D. Double this reading for actual voltage.

Receiver Verification BSS 7048 section 5.2.2.2.b. “Receiver” requires that the instrument produce deflection of 80% of full scale given a calibrated input. The signal response must not vary more than ±10% in a 15 minute period or more than ±20% over the calibration period. Gain must be within ±2 dB for any combination of gain setting changes. Vertical and horizontal displays must be within 5% of the full scale calibrated height and width. The alarm shall activate when the signal is within ±10% of the indicated alarm value. Null the instrument Depress the button on the gain test box toward coil “A”. Adjust the phase so that the resultant indication moves horizontally to the left and that depressing the button towards “B” moves the indication to the right. Adjust Gain to verify that the signal moves at least 80% of full screen. Record Pass or Fail. Adjust Gain so that depressing the button on the gain test box yields an indication of 5 divisions on the instrument screen (approximately 84 dB setting). While holding the button depressed toward Coil “A”, use the phase control to rotate the dot around the screen and verify that a circle with a radius of 5 divisions ± ½ division is drawn on the screen. Record Pass or Fail.

Receiver Verification (Continued) Repeat while holding the button depressed toward Coil “B”. Record Pass or Fail. Reduce Gain by 3 dB and verify that the circle is reduced to a radius of 3.5 divisions (70%) ±0.35 divisions for both Coil “A” and “B”. Record Pass or Fail. Reduce Gain by 6 dB from the initial Gain setting and verify that the circle is reduced to a radius of 2.5 divisions (50%) ± ¼ division for both Coil “A” and Coil “B”. Record Pass or Fail. Reduce Gain by 20 dB from the initial Gain setting and verify that the circle is reduced to a radius of .5 divisions (10%) with no visible ovality for both Coil “A” and Coil “B”. Record Pass or Fail. Return Gain to the initial setting and verify that the circle does not change more than ½ division over a 15 minute period for both Coil “A” and Coil “B”. Record Pass or Fail. -3dB (70%) -6dB (50%) -20dB (10%)

CERTIFICATE OF CALIBRATION Nortec 2000D Eddy Current Test Instrument Serial Number: ________ Test Date: __________ Date Due: __________ Technician: ________________ Counter: __________ Ser #: ___________ Cal Due Date: _________ Oscilloscope: __________ Ser #: ___________ Cal Due Date: _________ Gain Test Box: __________ Ser #: ___________ Cal Due Date: _________ Frequency (+/-20%): 100 Hz ______ 500 Hz ______ 1 kHz ______ 5 kHz ______ 10 kHz______ 50 kHz______ 100 kHz______ 500 kHz______ 1 MHz ______ 5 MHz ______ 10 MHz______ 12 MHz______ Frequency Drift (+/-10% over 15 min.): Pass ____ Fail ____ Oscillator Amplitude (+/-20%): High (4.5 Vp-p) ______ Mid (3 Vp-p) ______ Low (1 Vp-p) ______ Oscillator Amplitude Drift (+/-10% over 15 min.): Pass ____ Fail ____ Receiver Gain (80% full screen deflection): Pass ____ Fail ____

Receiver Linearity (+/-5% full scale height & width): Frequency 1: Gain Display Reduction Amplitude Coil A Amplitude Coil B Amplitude Ref 100% Pass ____ Fail ____ Pass ____ Fail ____ -3dB 70% Pass ____ Fail ____ Pass ____ Fail ____ -6dB 50% Pass ____ Fail ____ Pass ____ Fail ____ -20dB 10% Pass ____ Fail ____ Pass ____ Fail ____ Receiver Linearity Drift (+/-10% over 15 min.): Pass ____ Fail ____ Alarm: Pass ____ Fail ____ Alarm Level (+/- 10% of indicated value): Pass ____ Fail ____ Oscillator Amplitude Drift (+/-20% over test period): Pass ____ Fail ____ Receiver Linearity Drift (+/-10% over test period): Pass ____ Fail ____