Entry-level, Ethernet-to-serial-line gateway

Slides:



Advertisements
Similar presentations
INTRODUCTION TO Wi-Fi TECHNOLOGY.
Advertisements

PV String Monitoring Solution
1 Series V4T 1/4 DIN Temperature Controllers. 2 3 Watlows Next Generation Styling Series 97 Matching 1/16 DIN Limit Controller Series F4S and F4D Ramping.
Introduction to the WatchGuard AP Device
PGA309 EVM Multi-Cal-Tools-V1.6a User’s Guide
1 UNIT I (Contd..) High-Speed LANs. 2 Introduction Fast Ethernet and Gigabit Ethernet Fast Ethernet and Gigabit Ethernet Fibre Channel Fibre Channel High-speed.
Follow the instruction to install the PC Suite from the SD card: 1.Go to the settings -> SD Card & phone storage -> Enable the mass storage only mode 2.Connect.
Virtual Trunk Protocol
Communicating over the Network
Orion Telecom Networks Inc Remote Alarm Reporting and Site Monitoring Equipment Slide 1 Updated : January 1st, , Avenue of Fountains, Suite.
CL100D series DSP controlled Uninterruptible power supplies.
1 Chapter One Introduction to Computer Networks and Data Communications.
Version 1.0 digitaloffice.intel.com Intel ® vPro Technology Intel ® Active Management Technology Setup and Configuration HP Laptop – Compaq 6910p Small.
The VARAN Bus, the Real-Time Ethernet Bus System 1 / 23 The VARAN Bus.
Chapter 1: Introduction to Scaling Networks
Local Area Networks - Internetworking
© 2008 Cisco Systems, Inc. All rights reserved.Cisco ConfidentialPresentation_ID 1 Chapter 8: Subnetting IP Networks Network Fundamentals.
Square D Electrical Protection And Monitoring
Facility Monitoring System (FMSNet) PoE Ethernet HPC600 RPC200.
Telemetry Modules Quick Start
KX-HGT100 SIP-Phone. KX-HGT100 Configuration (1) User name: KX-HGT100 Password: kx-hgt100 1.Connect the HGT100 to the LAN via a suitable switch port 2.Power.
© 2007 Cisco Systems, Inc. All rights reserved.Cisco Public 1 EN0129 PC AND NETWORK TECHNOLOGY I IP ADDRESSING AND SUBNETS Derived From CCNA Network Fundamentals.
CY-SWR1100 Dual Band Wireless N Router
1 © 2004, Cisco Systems, Inc. All rights reserved. CCNA 1 v3.1 Module 1 Introduction to Networking.
Chapter 9: Subnetting IP Networks
25 seconds left…...
How To Set Up A Wireless Network Using A D-Link Wireless Router
© 2007 Cisco Systems, Inc. All rights reserved.Cisco Public 1 Addressing the Network – IPv4 Network Fundamentals – Chapter 6.
Field Proven Performance – Industrial Grade Support DATA-LINC GROUP Training: CIX “30” Series I/O Extenders Released: 2012/12/10.
1 © 2004, Cisco Systems, Inc. All rights reserved. CCNA 1 v3.1 Module 1 Introduction to Networking.
Orion Telecom Networks Inc Slide 1 STM-1 63 E1 (Optical / Electrical) SDH Add-Drop Multiplexer Updated: Dec, 2010Orion Telecom Networks Inc
Niobrara R&D Corp Compact PLC Upgrades With the CERI.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
Eycon Visual Supervisor
© 2003, Cisco Systems, Inc. All rights reserved. FWL 1.0— © 2003, Cisco Systems, Inc. All rights reserved.
ADAM-4572 Ethernet To Modbus Solution Ethernet to Modbus Data Gateway
Applying Wireless in Legacy Systems
1 Introduction to Jan. 20, 2011 Vio Fan ICP DAS Co., Ltd. tDS-700 Series tGW-700 Series.
ZIGBEE Network Introduction Integrated with Zigbee or Bluetooth products Operation voltage : DC 7V ~ 40V. RS232 Interface Meets or Exceeds TIA/EIA-232-F.
Advantys ETB Ethernet IP67 I/O
Cyprus Conference 2007 Simplex PoE Clocks. 2 Simplex PoE Clocks.
Make the most of your energy June 2008 Power Meter 800 PowerLogic ® Power Meter 8ECC.
P.1 Examples of Applications for the tDS-700 Dec.22, 2010.
P.1 Examples of Applications for the tGW-700 Dec.22, 2010.
eAutomation Enabler – Advantech Industrial NETworking
Integrated gateway-server for entry-level system monitoring
Make the most of your energy December 2008 ECC21 Needing a total network solution? PowerLogic Ethernet Communications Card (ECC21)
Ch. 5 – Access Points. Overview Access Point Connection.
Looking for a more powerful circuit monitor?
MC-1610MR / MC-1610MR48 16-Slot Managed Media Converter Chassis Copyright © PLANET Technology Corporation. All rights reserved.
A BRIEF INTRODUCTION TO FIELDBUS 4 hf NETLOGIC PLC TRADITIONAL CABLING SYSTEM TERMINAL BOARD.
Need to enhance your network?
ETHLON LonWorks Ethernet Adapter Conventional Approach SIPAI Solution ETHLON DIRECTLY REPLACES SLTA-10 OR SLTA CONNECTIONS.
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
Make the most of your energy December 2008 PM8ECC Need improved Network capabilities out of your meter? PowerLogic ® PM8ECC.
Advancing eAutomation 2-port Ethernet to RS-232/422/485 Data Gateway ADAM-4570 Reported by Alex Hsueh IAG Web & Comm. PM
M340 Modbus Plus Proxy Link legacy systems to Ethernet
Internet 0 for Industrial Applications Fred Cohn 13-Dec-07.
New product introduction:
Industrial Ethernet active portfolio All models available in standard temperature variants 0°C to +60°C and extended temperature variants -40°C to +75°C.
Serial / Ethernet Converter - IE-CS-2TX-XRS232/485
Serial/Fiber-Converter - IE-MCT-1RS232/485-1SC/ST
1-Port Ultra PoE to 4-Port 802.3af/at Gigabit PoE Extender
IFIP-UNU ADVANCED COURSE ON NETWORKING AND SECURITY Module II-Wireless Communications Section 5 Access Points.
Industrial 1-port RS422/485 Modbus Gateway
Industrial Ethernet Solution
Network Peripheral.
NT24k® & 1000 PoE+ Offerings October 2016.
Ethernet Gateway EGX200 - EGX400
Integrated gateway-server
Presentation transcript:

Entry-level, Ethernet-to-serial-line gateway PowerLogic EGX100 Entry-level, Ethernet-to-serial-line gateway

Why an Ethernet-based network? Ethernet networks are commonly used for power monitoring for the following reasons: High performance and reliable communication Does not require high-level knowledge of Ethernet and communication Wide use of Intranet and Internet Easy system expansion: On-the-fly device additions Compliant with Industry Standards (UL, CSA, FCC, CE)

Workstation Modbus TCP/IP Web browser PowerLogic EGX100 The EGX100 is an intelligent Ethernet gateway that provides fast, reliable Ethernet-to-serial line connectivity between intelligent meters, sensors, and other remote instruments Ethernet provides high-speed access to critical information. Use the existing LAN to greatly reduce comms, wiring, and network management costs. Workstation Modbus TCP/IP Web browser PLC Modbus TCP/IP Master Ethernet TCP/IP Connect up to 32 Modbus or Powerlogic serial devices per gateway — more with repeaters. Serial line Serial line Control devices Energy management devices

PowerLogic EGX100 benefits Easy to install — Power over Ethernet eliminates the need for control power transformers, disconnects and AC/DC power supplies reducing installation time/cost Easy to set up — Configure the gateway using web pages viewed in Internet Explorer. Simply enter an IP address, set the serial port baud rate, and the gateway is ready to go! Easy to maintain — Field upgradeable firmware lets you add new features in a flash, minimizing costly downtime Detailed diagnostics for Ethernet and serial ports viewable via web pages Support for future option modules (protocols, I/O, etc.) Robust — An extended operating temperature range of -25 to 70° C enables operation in harsh environments

Benefits Secure Windows-style username and password login TCP/IP filtering to control access to serial devices Only the specified master devices can connect Each master can be assigned Read-only, Full- or No-access TCP/IP Filtering lets you specify an access level for up to ten Modbus TCP/IP masters An administrator can control access to individual web pages by user group

Benefits Serial Master Support (Subnet initiated communications) — Allows a serial Modbus RTU or Modbus ASCII master device to access devices across the Ethernet network Provides connectivity to sixteen (16) Modbus TCP/IP interfaces supporting up to 128 serial slave devices Modbus serial link Modbus master device EGX EGX100 serial slave mode PLC RS232 RS85 Ethernet TCP/IP The PowerLogic EGX100 configured for Serial Master Support is ideal for converting legacy serial-based systems to Ethernet Up to 16 TCP/IP interfaces Up to 128 serial devices

Exterior features RJ45 Ethernet port Control power (IEEE802.3af) (screw terminal connector) RJ45 Ethernet port (IEEE802.3af) LED indicator for power & status Recessed reset button LED indicators for Ethernet and serial communications

Exterior features RS485 serial port (screw terminal connector) Bias, Termination, and 2-wire / 4-wire jumper switches RS232 serial port (RJ45 connector)

Technical highlights Ethernet Serial Environmental 10/100BaseTX Concurrent ModbusTCP/IP connections: 32 Serial All lines optically isolated Protocols: ModbusRTU, ModbusASCII, Powerlogic, Jbus Environmental Operating temperature: -25 to 70oC Enclosure: Din-rail mount, Multi-9 (72mm) IP rating: IP30

Accessory: Configuration kit (TCSEAK0100) Allows configuration via RS232 serial or Ethernet port Kit contents: RJ45 to DB9F adapter CAT5 Crossover cable, 3-meters (10-feet), orange Instruction sheet

Accessory: PoE Injector (TCSEAV0100) Typically, the largest cost associated with installing a gateway into an existing installation is the cost to provide control power The Power Over Ethernet (PoE) standard (IEEE 802.3af) defines how control power can be provided to an end device through a standard CAT5 Ethernet cable PoE eliminates the need for CPTs, disconnects, and AC-DC power supplies while greatly reducing installation time Kit contents: PoE midspan injector Universal power cord, 2 meters Plug adapters for Australia, Europe, UK, USA CAT 5 Ethernet patch cable, 2 meters Instructions

PowerLogic EGX100 user interface The home page provides access to Diagnostics and Setup functions.

PowerLogic EGX100 user interface The ‘Ethernet & TCP/IP’ page lets you configure the Ethernet connection and address.

PowerLogic EGX100 user interface The EGX100’s flexible serial port can be configured as a master (for connection to serial slave devices) or a slave (for connection to a serial master).

PowerLogic EGX100 user interface When the serial port is in ‘master’ mode, the EGX100 supports mixed-mode daisy chains in which devices of different protocols share the same serial line.

PowerLogic EGX100 user interface When configured for serial master support (serial port in ‘slave’ mode), the EGX100 provides connectivity to sixteen Modbus TCP/IP interfaces.

PowerLogic EGX100 user interface When configured for serial master support (serial port in ‘slave’ mode), the EGX100 can route to 128 serial slave devices.

PowerLogic EGX100 user interface Windows-style user and group security provides customizable, password-protected access to configuration screens.

PowerLogic EGX100 user interface An Administrator can assign access to web pages by user group.

PowerLogic EGX100 user interface TCP/IP filtering lets an administrator control which TCP/IP master devices can access serial devices through the gateway. Each master device can be assigned Read-only, Full- or No-access.

PowerLogic EGX100 user interface Simple Network Management Protocol MIB2 provides IT managers information about the EGX.

PowerLogic EGX100 user interface Detailed statistics can help troubleshoot network problems.

PowerLogic EGX100 user interface When the serial port is in “master” mode, a pop-up window shows the active ModbusTCP/IP connections.

PowerLogic EGX100 user interface The Read Register feature lets you read the register contents of connected serial devices.

Technical specifications Transparent Ready Classification: B15 Ethernet 10/100BaseTx Media Type: 10T/100Tx Auto 10BaseT-HD 10BaseT-FD 100BaseTx-HD 100BaseTx-FD Framing: Ethernet II & 802.3 (SNAP) IP Parameters: Address, Subnet Mask, & Default Gateway Protocols: HTTP, ModbusTCP/IP, FTP, SNMP (MIB2), TCP, UDP, ARP, ICMP Connector: RJ45; Industry standard pinout Concurrent ModbusTCP/IP connections: 32 Duplicate IP address detection (FDR basic)

Technical specifications Serial line Isolation: All lines optically isolated Physical interface: RS485 4-wire, RS485 2-wire, RS232 Protocols: Modbus RTU, Powerlogic (SY/MAX), Modbus ASCII, Jbus Baud: 2400–38400bps (RS485); 2400-57600bps (RS232) Parity: None & Even Response timeout: 0.1 to 10-seconds (default = 3-seconds) Connector: RS485 – 5-position plugable screw-terminal RS232 – RJ45; industry standard pinout

Technical specifications Diagnostics available through web interface: Specific counters for Ethernet, ModbusTCP/IP, and Serial Line On-board READ register viewer Environmental Operating temperature: -25 to 70oC Enclosure: Multi-9 (72mm) IP rating: IP30 Emissions: EN55022; EN55011; EN61000-3-2, 3 FCC Part15 Class A Immunity: EN61000-6-2; EN61000-4-2, 3, 4, 5, 6, 8 Safety: EN60950 CB Scheme Agency: UL, cUL, CE Control power: PoE (IEEE802.3af) or 24Vdc, 4w

For more information … Please visit www.PowerLogic.com