Healthcare Environments

Slides:



Advertisements
Similar presentations
Safety Absolutes Green Lake
Advertisements

Wi-Fi Technology.
Cabling system components
BSA Health System, May 2009 Next Slide Previous Slide BSA HEALTH SYSTEM Infection Control during Construction, Renovation, Repairs, and Maintenance All.
1 CNS/GSS/2008/M1 1 Module 1 Basic Terminologies and Characteristics of Switchgear.
© 2010 AT&T Intellectual Property. All rights reserved. AT&T, the AT&T logo and all other AT&T marks contained herein are trademarks of AT&T Intellectual.
Installation. Indoor Unit Installation Typical Installation.
Is Your Network Ready for the iPad? George Bentinck MBCS MIET Sales Engineer, EMEA +44 (0) Twitter: meraki_se.
Subpart R Steel Erection
WiFi VS Cellular “Bringing Secure Payment to the Point Of Service”
The Cable Guys Inc. Drew Leach Tom McLoughlin Philip Mauldin Bill Smith.
Emergency Lighting Code Review Presented by Iota Engineering LLC.
Nurse Call Systems & Emergency Call Systems Overview of ANSI/UL 1069 and ANSI/UL 2560 NOTES ABOUT THIS PRESENTATION: Review Oxygen-Enriched Environments.
Smart Grid - Cyber Security Small Rural Electric George Gamble Black & Veatch
ABANDONED CABLE REMOVAL Big Opportunity for Contractors By Frank Bisbee.
© 2012 International Business Machines Corporation 1 North America IOT 1Q All Manager and Executive Call IBM Smarter Healthcare Networks A better medical.
Cisco Networking Academy ProgramCopyright 2003Fundamentals of Voice and Data Cabling 1.2 Overview Hand out graded Labs Worldwide standards organizations.
3/4/2009. Cabling for n Scott D. Thompson President, Oberon, Inc. Cabling for n Scott D. Thompson President, Oberon, Inc.
1CUL.PPT Last Revised: 10 June 2005 The Role of the Communications Unit Leader Developed as part of the National Emergency Services Curriculum Project.
Confidential and proprietary materials for authorized Verizon personnel and outside agencies only. Use, disclosure or distribution of this material is.
© 2012 International Business Machines Corporation 1 North America IOT 1Q All Manager and Executive Call IBM Smarter Healthcare Networks A better medical.
Introduction to Oberon Products Wireless LAN infrastructure, Workspace telecom enclosures, AV equipment enclosures and mounting solutions Introduction.
Oberon Webinar: Cabling and Infrastructure for Enterprise Wireless Networks 1 Wireless Connectivity in Healthcare Facilities Scott D. Thompson President.
Chap 9 Structure Cabling Project Andres, Wen-Yuan Liao Department of Computer Science and Engineering De Lin Institute of Technology
CIM Webcast Wireless in Education Wireless Needs in Education Facilities Scott D. Thompson President Oberon, Inc. Senior Member, IEEE August.
Health Facilities Planning Seminar Plan Review Division Irvin J. Poke, AIA, Chief Todd Y. Cordill, NCARB, Assistant Chief Providing for Michigan’s Safety.
© 2006 Cisco Systems, Inc. All rights reserved.Cisco ConfidentialPresentation_ID 1 FCC-NTIA Joint Advisory Committee on Communications Capabilities of.
Shaping Tomorrow’s Built Environments Today. Who We Are 52,000 volunteer members in over 130 countries – More than 170 chapters – More than 250 student.
Commissioning of Fire Protection and Life Safety Systems Presented by: Charles Kilfoil Bechtel National Waste Treatment Plant Richland WA.
ARCHITECTURAL DESIGN Residential Design Criteria 1 1 Copyright © Texas Education Agency, All rights reserved.
Safety Training Presentation
Cabling and Infrastructure for Enterprise Wireless Networks
Security Professional Services. Security Assessments Vulnerability Assessment IT Security Assessment Firewall Migration Custom Professional Security Services.
Oberon Webinar: Cabling and Infrastructure for Enterprise Wireless Networks Link-Up Cabling and Infrastructure for Enterprise Wireless Networks.
The University of Bolton School of Business & Creative Technologies Wireless Networks Introduction 1.
1 Telecom Cabling THE NATIONAL ELECTRIC CODE AND THE STANDARDS THE NATIONAL ELECTRIC CODE AND THE STANDARDS.
The Association of Electrical and Medical Imaging Equipment Manufacturers Nurse Call Systems & Emergency Call Systems Overview of ANSI/UL 1069 and ANSI/UL.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. CENTERLINE 2100 Motor Control Center - SecureConnect™ September 1, 2011.
© 2015 American Society for Healthcare Engineering, a personal membership group of the American Hospital Association 155 N. Wacker Drive, Suite 400 | Chicago,
CIM Webcast New Gigabit Wireless Technologies New Gigabit Wireless Connectivity Scott D. Thompson President Oberon, Inc. Senior Member, IEEE.
2 IMPACT - THE FIRE PERMIT = Hot Work Permit 3 Welcome ! This course is linked to the use of IMPACT, so it is assumed that: You know how to use IMPACT.
Signamax™ Cabling System Review Revision E. INTRODUCTION.
ORGANIZING IT SERVICES AND PERSONNEL (PART 1) Lecture 7.
TELECOMMUNICATIONS SPACES
Electromagnetic Interference (EMI) in the Hospital Lake Regional Health System.
Cisco Aironet 350 Series: The Right Choice for the Enterprise.
HEALTHCARE SYSTEM Infection Control during Construction, Renovation, Repairs, and Maintenance All workers engaged in the construction, renovation, repair,
Fundamental Concepts for Design of Special Hazard and Fire Alarm Systems Chapter 1.
S305 – Network Infrastructure Chapter 6 Local Area Network.
Wired for Wireless with Twisted Pair Cabling Bree Murphy, RCDD Applications Engineer Oberon, Inc. Wired for Wireless with Twisted Pair Cabling Bree Murphy,
Steve Griffith February 28th, 2017
Radio Frequency (RF) Safety When Working Near Cellular Antennas
Practicalities of Deploying Wireless LANs In Healthcare
Professional Wi-Fi Installation Solutions
Professional Wi-Fi Installation Solutions
with Twisted Pair Cabling
Photovoltaic Systems Engineering Session 19
Institution Affiliated
THUM Adapter Impact on Hazardous Area Classification
Improving the WiFi Customer Experience
Professional Wi-Fi Installation Solutions
ASHRAE, California Title 24, NEC
ICT & Environment Seminar
Wired and Wireless Troubleshooting
General Requirements of NFPA 101
1 Stadium Company Network. The Stadium Company Project Is a sports facility management company that manages a stadium. Stadium Company needs to upgrade.
Photovoltaic Systems Engineering Session 12
Environmental factors need to be taken into account within healthcare and other settings For example Ceiling systems of a lay-in ceiling tile design should.
Presentation transcript:

Healthcare Environments Scott D. Thompson President Oberon, Inc. Task Group Member TIA-1179 Healthcare Facility Cabling Standard Senior Member, IEEE Wireless Systems in Healthcare Environments Including ICRA and TIA 1179

Oberon’s Mission: Oberon is the preferred source for wireless LAN access point enclosures, installation and mounting solutions, antennas, and workspace telecom enclosures for cost effective, secure, code compliant, aesthetic enterprise Wi-Fi deployments. Oberon's products are designed by experts with exceptional in-the-field, wireless LAN industry experience. Oberon has formalized agreements with the following manufacturers for engineered enclosure and mounting solutions for wireless networks:          

We manufacture ceiling and wall mounted Tele- communications Enclosures (TEs) for wireless LAN access points and other networking components Oberon is leading manufacturer of telecommunications enclosures and wireless access point enclosures, mounting solutions antennas, cables, and other accessories. TIA, IEEE and various healthcare standards and procedures impact how we design our products Wireless AP enclosure Workspace Telecom Enclosures

Agenda How are (Wi-Fi, DAS) endpoints (Access points, Remotes) installed? Infection control requirements (ICR) in Hospitals Code Compliance: Working in the “plenum” space TIA-1179 and wireless networks Reliable performance mandates Aesthetics Who to sell to The agenda today is comprised of the following : Wireless design specifics for healthcare Standards that apply for cabling and wireless TIA-1179 and wireless networks Infection control requirements (ICR) Working in the plenum space

Healthcare Wi-Fi and DAS - Hospitals were “early adopters” of wireless networking In hospitals, wireless networking is mission critical, serving point of care (bedside) applications, mobile workstations on carts (COWS), EHR, mobile asset tracking, RFID, telemetry, voice, etc. Hospitals have special requirements that are becoming more widely adopted: Infection Control Risk Assessment (ICRA) Strict adherence to codes and standards (NEC and TIA) Physical Security Preservation of the design for mandated performance Aesthetics

Installing Wireless LAN Access Points (APs) and Cellular in-building wireless (or DAS) remote units (herein referred to as “APs” Method 1: AP above the ceiling Method 2: AP attached to ceiling grid Method 3: AP in a ceiling enclosure or locking mount Method 4: AP on the wall

Preferred installation orientation for best coverage AP above ceiling AP on the ceiling grid AP in enclosure AP on the wall

Method 1: AP above the ceiling- things to avoid Cracked ceiling tile A lot of metal “Poke thru” antenna

Method 1: AP above the ceiling Use a hanger sturdy enough for AP, use a support wire Equipment should be UL 2043 “Plenum rated” Support Wire Oberon P/N 1045-00 above-ceiling hanger

Method 2: AP on the Ceiling Grid Avoid lifting ceiling tile Minimize hole in tile Conceal cable Lock AP

Infection Control Risk Assessment (ICRA) In Healthcare, the Joint Commission on Hospital Accreditation requires that hospitals establish procedures for mitigating the spread of infectious disease and contaminants- limiting access to the space above suspended ceilings (where dust has accumulated) Infection control risk assessment (ICRA) could have a serious impact on the times and conditions for cabling installation, moves, adds and changes, particularly in the air-handling “plenum” space, above suspended ceilings, or walls Breaches in the ceiling system should be avoided Contractors performing work in violation of ICRA procedures will be precluded from future bidding

Infection Control Requirements (ICR) Lifting or removing ceiling tiles requires the installer to: Use Negative Air Pressure Enclosure (NAPE), or “tent off” the work area Use a HEPA air filter OR Work in the plenum space, which requires ceiling tiles to be lifted or removed, entails building a negative air pressure tent (or tenting-off the area) and providing for HEPA air filtration

Method 3: Install AP in a ceiling enclosure or locking mount to simplify ICRA procedure compliance Oberon model 1052 With ZDUAL antennas on door

Method 3: Install AP in a ceiling enclosure or locking mount to simplify ICRA procedure compliance Oberon model 1059 ICRA in Healthcare

Antennas on door AP in the Door Method 3: Install AP in a ceiling enclosure or locking mount to simplify ICRA procedure compliance Oberon 1052-CCOANT Oberon 1052-CCOAP Antennas on door AP in the Door

Code Compliance Hospitals are strict adherents to building safety codes and telecommunications standards Many Authorities Having Jurisdiction (AHJs) will require strict NEC compliance and UL listing of installed components Burn ratings of ceiling systems must be retained Oberon’s enclosures are designed to satisfy National Electric Code (NEC) paragraphs 300.22 and 300.23 for installation in the air-handling (plenum) space All of Oberon’s ceiling enclosure products are UL listed

N.E.C COMPLIANCE Article 300.22(C)(3) “Electrical equipment with a metal enclosure, or electrical equipment with a nonmetallic enclosure listed for use within an air-handling space……. shall be permitted to be installed in such other space unless prohibited elsewhere in this Code”. Article 300.23 “cables, race-ways and equipment installed behind panels, including suspended ceiling tiles, shall be arranged and secured so as to allow removal of panels and access to the equipment.” Now with the definition of the air-handling/ plenum space in hand, this section of the code then goes on to state that “Electrical equipment with a metal enclosure, or electrical equipment with a nonmetallic enclosure listed for use within an air-handling space……. shall be permitted to be installed in such other space unless prohibited elsewhere in this Code”. AND Article 300.23 “cables, race-ways and equipment installed behind panels, including suspended ceiling tiles, shall be arranged and secured so as to allow removal of panels and access to the equipment.”

Method 3: Install AP in a ceiling enclosure or locking mount to ensure code compliance Oberon model 1028 w ZDUAL Antennas Code Compliance

TIA-1179 Healthcare Facility Telecommunications Cabling Standard Recognizes that “adding or changing horizontal cabling may cause disruption to occupants and their work once the buildings ceiling and walls are closed” Adding or changing horizontal cabling could result in a net decrease in care being provide, jeopardizing infection control measures…. Advocates use of enclosed pathways in air-handling spaces to avoid disruption of operations Advocates planning well ahead in cabling design and capacity Telecommunications enclosures (TEs) are an option in areas subject to infection control measures TRs and TEs should incorporate additional security measures to restrict access (Workgroup switches and APs)

TIA-1179 Healthcare Facility Telecommunications Cabling Standard Recognizing that many healthcare installations make use of a number of wireless applications, “It is recommended that the wireless environment be characterized and understood prior to the design, choice, and installation of cabling to ensure satisfactory operation” Telecommunications Industry Association TIA 569-B – accepts use of telecommunications enclosures in the ceiling space to secure wireless access points and other networking appliances, and advocates protecting infrastructure

Method 3: Install AP in a ceiling enclosure or locking mount for standards compliance and best practice Oberon 1072-00 DAS, Wi-Fi AP and Switch in Enclosure

Physical Security and Reliable Performance Mandates Some jurisdictions have enacted ordinances that include provisions for radio coverage of public safety signals within the building as a condition of occupancy Includes signal level and reliability Grapevine, TX - Ord. No. 109.2 , Min signal -107 dBm, 95 % of each floor 800 MHz band, Adjacent band filtering, 8 hour battery backup Suggests requirement to “lock down” the wireless infrastructure Furthermore, protection of confidential patient information (HIPAA), suggests access points should be physically secured

Method 3: Install AP in a ceiling enclosure or locking mount for physical security and reliable performance mandates Oberon model 1030 w/ ceiling flange Improve RF coverage and preserve the site survey

Method 3: Install AP in a ceiling enclosure or locking mount for physical security and reliable performance mandates Oberon model 1052 with ZDUAL antennas Physical Protection of AP and Antennas

Method 4: Install AP on wall enclosure or locking mount for physical security and reliable performance mandates Oberon model 1022 w ZDUAL Antennas Prevent obstruction or tampering

Method 4: Install AP on wall enclosure or locking mount for physical security and reliable performance mandates Oberon 1032-C Oberon 1029-00 Locking Case Right Angle Wall Bracket

Method 4: Install AP on wall enclosure or locking mount for physical security and reliable performance mandates When using NEMA boxes outside: Avoid direct sun Avoid Metal Consider thermal rise. See Oberon application note at NEMA Enclosures http://www.oberonwireless.com/WebDocs/App_Note_Calculating_temperature_rise_in_Enclosures.pdf

Aesthetics Unlike most data com infrastructure products, the wireless access point or antenna is highly visible Many hospitals have aesthetics committees Architects may specify color and style Custom styles and colors are available

Method 3: Install AP in a ceiling enclosure or locking mount for aesthetic, professional installation Oberon model 1053 with Cisco antennas Aesthetics and Convenience

Method 3: Install AP in a ceiling enclosure or locking mount for aesthetic, professional installation Oberon model 1064 w Cisco 1140 AP Architectural style match

Simplify Moves, Adds, Changes, and technology upgrades Terminate cable at the enclosure, test and verify cabling at that point Un-necessary to lift ceiling tile to service access points Methods to easily migrate to new vendors and technologies

Method 3: Install AP in a ceiling enclosure or locking mount to simplify moves, adds, changes, and technology upgrades Oberon model 38-1052-ADPDOOR-AP105 Interchangeable doors permit simple upgrades to completely different access points

Method 3: Install AP in a ceiling enclosure or locking mount to simplify moves, adds, changes, and technology upgrades Oberon 1068-00 Oberon 1068-00 with Cisco AP Oberon 1068-00 with Aruba Networks AP Oberon 1068-00 with Ruckus AP Universal locking ceiling mount

Who to sell to Telecom/datacom infrastructure- cabling and wireless personnel Plant Services or Facilities Personnel Infection prevention and control coordinator or Infection Preventionist- in Quality Control or Patient Services Department Public safety/in-building comm coordinator Bio-Medical personnel

Other verticals where Oberon wireless enclosures may be required: Healthcare- Many hospitals have Infection Control Risk Assessment (ICRA) procedures. These procedures mitigate access to the space above ceiling tiles to restrict the spread of infectious diseases. Retail – The Payment Card Industry Data Security Standard (PCI-DSS) requirement 9.1.3 states that the operator must “Restrict physical access to wireless access points, gateways, and handheld devices” Government – Directive 8100.2 mandates FIPS 140-2 compliance wherein FIPS 140-2 paragraph 4.5 requires “physical security mechanisms” to be applied Certain Municipalities - Some jurisdictions have enacted ordinances that include provisions for radio coverage of public safety signals within the building as a condition of occupancy Education- Wireless is mission critical, mass notification systems must be reliable

Enclosures in Healthcare? Why use Oberon AP Enclosures in Healthcare? Simplify ICRA procedure compliance when installing and servicing wireless access points Clear-cut National Electric Code (N.E.C.) compliance Physical security Protect the integrity of the RF coverage design Verify cabling to the enclosure prior to AP install Simplified Moves, Adds, and Changes (MACs) Clean, professional, aesthetic installation

See the wireless AP mounting solution finder at: www.oberonwireless.com