Ventilating The Face Area

Slides:



Advertisements
Similar presentations
1 Construction and Renovation Activities in Healthcare Facilities What construction crews should know, but were afraid to ask!
Advertisements

BRATTICE CLOTH 3.2 % CH4 10 PPM CO 19.1% 02 UNSAFE ROOF.
Booster fan applications for sections in longwall and room-and-pillar mining Christopher Pritchard MS PE Acting Team Lead Ventilation Group Fires and Explosions.
UTILIZATION OF BOOSTER FANS IN UNDERGROUND COAL MINES
1 Mine Ventilation Risks & Controls Jason Wagstaffe Wagstaffe & Associates.
Buildings and Structures 2 Natural and Mechanical Ventilation.
Keynote Address 14 th US/North American Mine Ventilation Symposium Christopher J Pritchard MS PE Mining Engineer Team Leader (Acting) Ventilation Group.
FABFAB FABFAB Field layout. FABFAB D DD e1e2e3e4w4w3w2w1 N Team Map.
1 Booster Fans - Some considerations for their usage in underground coal mines S. Gillies, C. Slaughter, F. Calizaya and H. W. Wu 13th United States/North.
Dust Division Pittsburgh Safety and Health Technology Center Mark Schultz Senior Mining Engineer.
Ventilation for Confined Spaces requires ventilation as follows: An employee may not enter the space until the forced air ventilation has eliminated.
1 2 Outline Airflow Measurements –How to take air readings –Measuring areas –Mean Entry Velocity Principals of Airflow When and Where to take Air Measurements.
TRI MARTIANA.  A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants such as dust, fumes,
MINE RESCUE ACTIVITY BOOK – Section II-a MSHA 2208 NOVEMBER 1981 JUNE 2005.
Felipe Calizaya Miles Stephens 2010 UTILIZATION OF BOOSTER FANS IN UNDERGROUND COAL MINES Stewart Gillies Univ. of Utah, Salt Lake City, UT Missouri Univ.
VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
2011 Colorado Metal and Nonmetal Mine Rescue Contest July 12 th thru 14 th, 2011 Idaho Springs, Colorado.
Code of Federal Regulations 30 Part 57 – Safety and Health Standards – Underground Metal and Nonmetal Mines Subpart J – Travelways and Escapeways
Chapter 4. Subsurface Ventilation Systems Mine Ventilation and Safety Jiangxi University of Science and Technology 1 Review for Last Classes 
Preventing Silicosis in the Mining Environment. 1.Prevention of Silicosis to Improve Mine Workers Health and Quality of Life. 2. Compliance with MSHA.
Contestant Briefing Hello I am ______and this is ________. You are to conduct a Pre-shift examination of the Bee No. 1 head gate section, for the oncoming.
2014 SOUTHEAST REGION FAB MAP FRESH AIR BASE BC x 20 POST.
SOME CRITICAL ISSUES OF THE INDIAN COAL MINING INDUSTRY PREPARED BY : KALYANI JHA.
Colorado Mine Rescue May 2015
Control of Airborne Respirable Dust Hazards: A Training Program for Underground Coal Miners The Penn State Miner Training Program University Park, PA
C CCC C CC X D x x x x #2 Pump x Section Transformer D D C C C C C C C R D D D D D D D D R #2 Belt Drive (Transfer Point – 2000’ to Surface) x NORTH MAINS.
On-Shift Examination Scenario Continuous Miner Section What you will need: Pencil and paper to take notes or perform calculations Calculator to calculate.
Aug 1 st 2014 Mine Rescue Practice Problem Ole Smokey # 9 mine.
Penn State The Penn State Miner Training Program
2013 MTTC Pennsylvania Regional Skills Contest April 22-25, 2013.
Mark J. Schultz, P.E. Chief, Environmental Assessment and Contaminant Control Branch Dust Division Mine Safety and Health Administration Pittsburgh Safety.
Problem Briefing 2013 Day 1 Problem Briefing ACA DAY 1 Statement You are located on the surface of RT #15 mine. This is a new highwall mine that.
Mine Health & Safety Inspectorate Northren Cape Region – May 2014 MH Sease - IOM.
Pre-Shift Examination Scenario Continuous Miner Section What you will need to complete this exercise: Pencil and paper to take notes or perform calculations.
Ventilation Map N FAB Entry 1 Entry 2 Entry 3 D East Decline West Shaft (Intake) Door Closed Temporary Stopping A Temporary Stopping B Mine Fan ON/OFF.
A ventilation curtain was hung from the roof bolt plates and extended across the last open crosscut. The ventilation curtain was rolled up by the victim.
Indiana Mine Rescue Statement 2013 Thank your for assisting us with our emergency at the Vincennes No. 1 Mine. You are located at the fresh air base established.
N FAB Entry 1 Entry 2 Entry 3 #3 (Intake) Check Curtain Caved Tight #2 (Intake) #1 (exhaust) Bear E. Bill E. Continuous Miner T-4 Haul Truck W/bed up On.
2012 Mine Rescue Contest Day 1 36 th May 15 th 2012 Judge’s Briefing.
D D PC B Loose Roof End of Water x x x x Suction hose 6 posts x x Posts set Refuge chamber Sump with pump Door opened Door closed Water over knee deep.
BY Dr. P. S. Paul Dept. of Mining Engineering Indian School of Mines University, Dhanbad.
This presentation is for illustrative and general educational purposes only and is not intended to substitute for the official MSHA Investigation Report.
Electrical system : Operator station PLC display Engine under operation - Operating the unit is carried out from the Operator Station. - Two rotary switch.
STATEMENT Welcome to the TG Mine and thank you for your help. We have a 5 person crew that was tagged in on the mine tag board. They were working an idle.
Rock Springs Mine Rescue June 2016 – Day 1
Maria’s Restaurant Chapter 1 Section 4
Controlled Recirculation of Air
VENTILATION OF GASSY UNDERGROUND MINES IN THE KARVINÁ REGION
Placement Considerations
Rock Dusting in Coal Mines
N N D D C Ventilation Map FAB Entry 1 Entry 2 Entry 3 Jim Swan 30-inch
38th 2014 Day 1 Problem Briefing Problem Briefing.
Price 2017 Day 2.
Tankabel Mining Co., Inc. I.D. No Rochester, NY Map Legend:
2013 Indiana Pre-Shift Contest
Projected Development
2012 PA Regional Skills Contest
Day Two.
2012 Mine Rescue Contest Day 2
OVERCAST WALL DOOR OPEN
2014 MTTC Pennsylvania Regional Skills Contest
2014 KCA Regional Skills Contest
DAY ONE.
FRESH AIR BASE Placard 1.
Fresh Air Base Statement
Exhaust gas intake to cabin air.
FACE.
2016 Illinois State Mine Rescue Contest
2016 Mine Rescue.
BLOWING FAN.
Presentation transcript:

Ventilating The Face Area Coal Mine Ventilation Ventilating The Face Area

Purpose of Ventilation Dilute, render harmless and carry off accumulations of dangerous gasses and dust from the mines. Supply fresh or uncontaminated air to persons working in the mine.

The Ventilation Current The Body of Air which is moved through a mine. Intake and Return

Ventilating Pressure Air, like any fluid body, will always move from a point of High Pressure to a point of Low Pressure.

Diagram of Main Fan at a Shaft Automatic Doors Explosion Door or Weak Wall Fan Impeller 15' Overburden Shaft Mine Entry

DIRECTION OF AIRFLOW INTAKE AIR

DIRECTION OF AIRFLOW RETURN AIR

PERMANENT STOPPING

TEMPORARY STOPPING

CHECK CURTAIN

LINE CURTAIN

OVERCAST Over Return Air Under Intake Air

REGULATOR

C C C R R

Longwall Ventilation

R R R c c c                              R                                 R R R R R R

Multi-Section Ventilation

c c c R R R R c R c c c c c

END