Presentation is loading. Please wait.

Presentation is loading. Please wait.

Indiana Mine Rescue Statement 2013 Thank your for assisting us with our emergency at the Vincennes No. 1 Mine. You are located at the fresh air base established.

Similar presentations


Presentation on theme: "Indiana Mine Rescue Statement 2013 Thank your for assisting us with our emergency at the Vincennes No. 1 Mine. You are located at the fresh air base established."— Presentation transcript:

1 Indiana Mine Rescue Statement 2013 Thank your for assisting us with our emergency at the Vincennes No. 1 Mine. You are located at the fresh air base established by the previous exploring mine rescue team. At around 4 am this morning a 7 man crew entered the 4 North Section to prep the unit and to load coal once the Main West belt was spliced and turned back on. The belt began running at approximately 5 am and the crew called out at 5:30 and stated they had loaded their first car of coal. The belt went down at approximately 6:50 and the mines tracking system showed that 2 men off the 4 South Section traveled out to the Main West drive unit. These 2 miners were able to get the belt running again and left the area and traveled back to the section. These 2 miners contacted the tracker on the surface and stated they felt larger rush of air, were overcome by dust and smoke and had traveled back to the Main West belt drive. They could not make contact with the miners of the 4 North section, so they were leaving the area and heading to the surface. These 2 miners have made it out of the mine and are being debriefed. The tracker has not been able to contact the miners on the 4 North Section and the mines tracking and communication is not working. This mine has experienced poor roof conditions and high concentrations of methane gas in the past. It is mining adjacent to the abandoned and sealed Vincennes No. 2 mine. The mine is being ventilated with blowing fan that can be shut off to reverse the fan, but not stalled out. The mine maps you will receive were up to date prior to the 7 man crew entering the 4 North section at 4 am this morning. That is all the information we have available at this time. Teams and working order 1.Viper 6. Five Star 2.Francisco 7. Gateway 3.Ky. Coal Academy 8. Gibson 4.Shoal Creek 9. Wildcat Hills 5.Indiana State 10. Lively Grove

2 Written Instructions Explore all areas of the mine that can be done safely Account for all missing persons Bring all survivors to the fresh air base Report all irrespirable atmospheres encountered to the Mine Superintendent You may not carry more than 2 sets of building materials at one time. Stoppings and barricades found intact can not be moved to another location

3 Patient Statement Help! Get me out of here. I am the only one in here, and I am feeling lighted headed and can’t breathe. Patient will be unconscious when team goes to remove him.

4 Person 2013 Indiana Mine Rescue Contest TEAM NO. ______ FIELD NO. ______ SCALE 1” = 10’ BO B xx x x x FACE Continuous Mining Machine Battery Ram car 13 Timbers Overcast Wall Door Open 5% CH4 0 PPM CO 12.0% 02 5% CH4 0 PPM CO 20.8% O2 1.5% CH4 0 PPM CO 18% O2 5.0% CH4 0 PPM CO 20.8% O2 BC LC Operable Battery Scoop 5% CH4 10 PPM CO 18.0% 02 B D D XXXXXXXX XXXXXXXXXXXX AIR TIGHT X Overcast Wall Door Closed XXXXXXXX 0.0% CH4 0 PPM CO 20.8%O2 BC Battery Ram Car X 5.0% CH4 0 PPM CO 20.8% O2 0.0% CH4 0 PPM CO 20.8% O2 BC X Person GT R/R DIDI DIDI DIDI GT DIDI R/R GT DIDI DIDI R/R GT DIDI R/R GT DIDI R/R GT DIDI DIDI R/R GT R/R DIDI GT DIDI DIDI DIDI DIDI R/R GT DIDI R/R GT DIDI R/R GT DI DIDI R/R GT DIDI Battery Mine Phone x D Cut into old works

5 Person 2013 Indiana Mine Rescue Contest TEAM NO. ______ FIELD NO. ______ SCALE 1” = 10’ BO B xx x x x FACE Continuous Mining Machine Battery Ram car 13 Timbers Overcast Wall Door Open 5% CH4 0 PPM CO 12.0% 02 5% CH4 0 PPM CO 20.8% O2 1.5% CH4 0 PPM CO 18% O2 5.0% CH4 0 PPM CO 20.8% O2 BC LC Operable Battery Scoop 5% CH4 10 PPM CO 18.0% 02 B D D XXXXXXXXXXX XXXXXXXXXXXX AIR TIGHT X Overcast Wall Door Closed XXXXXXXXXXX 0.0% CH4 0 PPM CO 20.8%O2 BC Battery Ram Car X 5.0% CH4 0 PPM CO 20.8% O2 0.0% CH4 0 PPM CO 20.8% O2 BC X Person D Cut into old works X Battery mine phone Note: Team must build two airlocks and rescue patient at this team stop Blowing / Exhaust

6 Person 2013 Indiana Mine Rescue Contest TEAM NO. ______ FIELD NO. ______ SCALE 1” = 10’ BO B xx x x x FACE Continuous Mining Machine Battery Ram car 13 Timbers Overcast Wall Door Open 5% CH4 0 PPM CO 12.0% 02 5% CH4 0 PPM CO 20.8% O2 1.5% CH4 0 PPM CO 18% O2 5.0% CH4 0 PPM CO 20.8% O2 BC LC Operable Battery Scoop 5% CH4 10 PPM CO 18.0% 02 B D D XXXXXXXXXXX XXXXXXXXXXXX AIR TIGHT X Overcast Wall Door Closed XXXXXXXXXXX 0.0% CH4 0 PPM CO 20.8%O2 BC Battery Ram Car X 5.0% CH4 0 PPM CO 20.8% O2 0.0% CH4 0 PPM CO 20.8% O2 BC X Person FIRST VENT BLOWING FAN Moved D Cut into old works X Battery mine phone move this vent to clear low O2 in intersection Blowing / Exhaust

7 Person 2013 Indiana Mine Rescue Contest TEAM NO. ______ FIELD NO. ______ SCALE 1” = 10’ BO B xx x x x FACE Continuous Mining Machine Battery Ram car 13 Timbers Overcast Wall Door closed 5% CH4 0 PPM CO 12.0% 02 5.0% CH4 0 PPM CO 20.8% O2 BC LC Operable Battery Scoop 5% CH4 10 PPM CO 18.0% 02 B D D XXXXXXXXXXX XXXXXXXXXXXX AIR TIGHT X Overcast Wall Door Closed XXXXXXXXXXX 0.0% CH4 0 PPM CO 20.8%O2 BC Battery Ram Car X BC X Harden Room Person SECOND VENT EXHAUSTING FAN Moved 1.5% CH4 0 PPM CO 18% O2 Cut into old works Blowing / Exhaust

8 ITEMS TO DISCUSS 75 minute time limit All placards in the entries to and including the first cross cut need to be turned upside down once you have checked to ensure they are in proper location. At the first team stop have the captain check to ensure all cap lamps are working. If one is not working discount under rule 50. Team can explore up any entry they chose, due to gases stopping at the temp stopping in 1,2 and 3. The patient behind the barricade in No. 3 is talking with team during initial exploration, but when team goes into recover the patient needs to be unconscious with head toward face against the left rib. Map judges the patient behind barricade will be talking at first, but then unconscious when team gets to them. Please mark on final vent map if the team explores outby the intersection once they timber through the unsafe roof in the 3rd xc. This needs to be noted so the map judges know what should and should not be on the maps. Written instructions require team not to carry more than 2 sets of building materials, relocate intact vent structures found, report low O2 to superintendent etc.…. Watch for these. If a team violates either of these it is discounted under rule 51. If they violate the same written instruction multiple times it is only discounted 1 time under rule 51. Two low O2 will have to be reported. Problem is designed for two vents but some teams may use 3 vents. Vent 1 = The fan will have to be reversed, then for 2 nd vent it will have to be reversed back to original direction. The superintendent will have a sign to hold up and show judges if fan is blowing or exhausting One vent 2 if the BO installs the curtain in the FAB the team will have sent low O2 over him if the fan is moving air from left to right. Once the team make a vent change please flip over the placards that are cleared with vent change. Once the team finds the 5% ch4 in the face of No. 1 they must FPA

9 xxxxxxxxxxxxxx B xx x x x x D x BC


Download ppt "Indiana Mine Rescue Statement 2013 Thank your for assisting us with our emergency at the Vincennes No. 1 Mine. You are located at the fresh air base established."

Similar presentations


Ads by Google