Interconnection of AES With The Grid

Slides:



Advertisements
Similar presentations
Beckett Energy Systems
Advertisements

DOD Microgrids The Missing Link: Microgrid Applications Michael Dempsey P.E. Burns & McDonnell June 12, 2013 © 2013 Burns & McDonnell. All Rights Reserved.
1 Pacific Gas & Electric Company MTS: Evolution of the Electric Distribution System Manho Yeung, Senior Director, System Planning and Reliability PG&E.
Project 1.4 Operational Strategies and Storage Technologies to Address Barriers for Very High Penetration of DG Units in Intelligent.
Net Metering and Utility Interconnection Presented by : Bill Brooks Brooks Engineering.
EE 369 POWER SYSTEM ANALYSIS
Chapter 8 Inverters AC Power • Inverters • Power Conditioning Units • Inverter Features and Specifications.
Grid-Microgrids Interconnection
Disconnect Switches There are many purposes for disconnect switches in substations and power lines. They are used to isolate or deenergize equipment for.
PowerPoint ® Presentation Chapter 12 Utility Interconnection Distributed Generation Generators Inverters Interconnection Codes and Standards Interconnection.
Terry Chandler Power Quality Inc, USA Power Quality Thailand LTD Sept /6/20091www.powerquality.org all rights reserve.
2015 World Forum on Energy Regulation May 25, 2015
1 Power Quality Mary Santori, P.E. Senior Engineer September 12, 2013.
Overcurrent Protection and Voltage Sag Coordination in Systems with Distributed Generation J. Carlos Gomez 1 M. M. Morcos 2 1 Rio Cuarto National University,
Distributed Generation & Distribution Companies Darius Vaiciunas Collingwood.
IEEE 1547: The DG Interconnection Standard
Module 5, Unit A Vocabulary Review Game. 2 pt 3 pt 4 pt 5pt 1 pt 2 pt 3 pt 4 pt 5 pt 1 pt 2pt 3 pt 4pt 5 pt 1pt 2pt 3 pt 4 pt 5 pt 1 pt 2 pt 3 pt 4pt.
Prepared By :.  Introduction  Techniques Used  Case Study  Advantages  Application  Conclusion OUTLINE.
Frankfurt (Germany), 6-9 June 2011 Smart Grid Protection in China Wu Guopei Guangzhou Power Supply Bureau Guangdong Power Grid, China.
Overview What's is micro grid Over view of electric grid
Assumption University Thailand EE4503 Electrical Systems Design Main Circuit 1.
CLEMSON UNIVERSITY DG CONFERENCE UPDATE ON THE CURRENT STATUS OF DG INTERCONNECTION PROTECTION WHAT IEEE 1547 DOESN’T TELL YOU ABOUT INTERCONNECTION PROTECTION.
Frankfurt (Germany), 6-9 June 2011  PV in Spain: Basically Large plants connected to MV or HV Mainly in rural areas (generation exceeds consumption) 3,000.
Grid Connection Issues Micro Hydro Projects Rachel Hodges.
05/18/001 N.Treadway Distributed Resources and Competitive Energy Markets in Illinois Workshop Session III, “Interconnection Issues” Thursday, May 18,
Queensland University of Technology CRICOS No J Protection of distributed generation connected networks with coordination of overcurrent relays.
Grid connection of distributed generation
1 Distributed Generation and Power Quality-Continued.
A common 400 Hz AC Power Supply Distribution System for CMS FEE. Authors C. Rivetta– Fermilab. F. Arteche, F. Szoncso, - CERN.
A Training Presentation On 220 KV GSS CHOMU,JAIPUR
A Training Presentation On 132 KV GSS JAIPUR Submitted in partial fulfillment For the award of the degree of BACHELOR OF TECHNOLOGY Submitted To:- Submitted.
Power Quality Issues Power Electronics Group.
Renewable Energy Systems David Buchla | Thomas Kissell | Thomas Floyd Copyright © 2015 by Pearson Education, Inc. All Rights Reserved Buchla, Kissell,
Equipment 1.Circuit Breaker. 3.Fuses. 4.Protecti- ve relay.2.Bus bar. TYPES OF SWITCH GEAR EQUIPMENT:-
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
A smart grid delivers electricity from suppliers to consumers using two-way digital technology to control appliances at consumers' homes to save energy,
Announcements Design Project has firm due date of Dec 4
Power Quality at Solar Distributed Generation Facilities
Sub Station.
Protection of Power Systems
Introduction to Global AC Power
Distributed Generation
IG BASED WINDFARMS USING STATCOM
Management Of Tulkarm Electrical Network
Interconnect Protection of Dispersed Generators
Microgrid Concepts and Distributed Generation Technologies
EE6501 POWER SYSTEM ANALYSIS
One Line Diagram Example
Circuit Breakers & Reclosers
APPLICATIONS Reference: Textbook-Chapter 6,8 & 9 'Power Electronics',C
Chapter 7 System Protection
Indian Grid Code and Commissioning Test Procedure Dr
Working with Utilities Sean W. Carr, P.E., PMP®
EU-IPA12/CS02 Development of the Renewable Energy Sector
Anna Brinck, M.S. Student Robert Cuzner, Assistant Professor
Training on Dr. Sudhir Kumar Grid Connected Rooftop PV Systems
Distributed Generation (DG) Modeling Criteria
Protective Relaying Conference
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
ELECTRICAL POWER-II Electrical engineering sixth semester
EET 323 – Electrical System Design Lecture 9: Grounding
EE362G Smart Grids: Architecture
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Ahmed Kulab Moh. Abed Foaad Al-Habeel
Waleed Iftikhar Michel Mabano
Components inverters Except where otherwise noted these materials are licensed Creative Commons Attribution 4.0 (CC BY)
Substation Equipment's
Long Island Interconnection Working Group Meeting August 22, 2019
Presentation transcript:

Interconnection of AES With The Grid And Its Considerations Emad-Eldin Mohamed-Ahmed Supervisor: Dr. Tan Chee Wei

AES: Alternative Energy Source EPS: Electrical Power Supply (Grid) Abbreviations AES: Alternative Energy Source EPS: Electrical Power Supply (Grid) PCC: Point of Common Coupling

Islanding AES continues to energize a portion of the area EPS that has been isolated fro the rest of the area EPS Up stream Breaker Fuse Automatic Sectionalizing Switch Manual

Islanding

Interconnection of AES with EPS The interconnection system is the means by which an AES unit connects electrically with the outside Electric Power System (EPS). It can also provide monitoring, control, metering, and dispatch of the AES unit.

Power conversion and conditioning Protection functions

Functions Autonomous and semiautonomous functions and operations AES and load controls. Ancillary services. voltage support, regulation, operating reserve, and backup supply. Communications. Communications allow the AES and local loads to interact and operate as part of a larger network of power systems or micro-grids. Metering. The metering function allows billing for AES energy production and local loads Net Metering FiT

Interconnection Technologies Synchronous Interconnection Induction Interconnection Inverter Interconnection

Standards And Codes IEEE 1547 NFPA 70 UL 1741, 1008, 2200

Considerations of Interconnection Voltage Regulation Maintain approximately constant voltage to users Machines Efficiency. Integration with Area EPS Grounding It is defined by its isolation or lack of isolation from adjacent grounding systems.

Considerations of Interconnection Synchronization To synchronize an AES with an area EPS. Isolation A readily accessible, lockable, visible-break isolation should be located between the area EPS and the AES. These switches provide visible isolation points to allow for safe work practices. Disconnect switches should be strategically installed to permit disconnection from all sources.

Considerations of Interconnection Response to Voltage Disturbance

Considerations of Interconnection Response to Frequency Disturbance When generation is matched inadequately with system load, the area EPS frequency will decline. System operator seeks to match load quickly with available generation. Under-frequency relays are installed on the distribution system to shed load automatically to stabilize operations.

Considerations of Interconnection Disconnection for Faults The AES should have, as a minimum, an interrupting device that is: Of sufficient capacity to interrupt maximum available fault current at its location Sized to meet all applicable ANSI and IEEE standards Installed to meet all local, state, and federal codes

Considerations of Interconnection Loss of Synchronism Result of islanding Transient during reclosing Phase angle separation magnitude across the isolation

Considerations of Interconnection Feeder Reclosing Coordination The AES is designed to cease energizing the area EPS before the reclosing event. The Re-closer is designed to delay reclosing event until AES has ceased energizing the area EPS The AES is controlled to ensure that the voltage phase-angle separation magnitude across the islation is less than one fourth of a cycle when the reclosing event occurs The The Re-closer is controlled to ensure that the voltage phase-angle separation magnitude across the islation is less than one fourth of a cycle when the reclosing event occurs The AES capacity is less than 33% of the minimum load in the feeder.

Considerations of Interconnection DC Injection Dc injection produces a dc offset in the basic power system waveform The increased half cycle voltage has the potential to increase saturation of magnetic components (transformers). This saturation causes increased power system distortion.

Considerations of Interconnection Voltage Flicker The AES has the potential of creating the flicker in voltage AES should not create objectionable flicker for other customers on the area EPS.

Considerations of Interconnection Harmonics

Considerations of Interconnection Unintentional Islanding Protection Undesired for an AES Safety and Power Quality Problems (area EPS and Local Loads) Repair Operations: Pose a threat Repair Operations: Delay of Service Restoration Prevention Limit AES installed capacity Reverse Power Protection at PCC Active anti islanding method (inverter based)

Thank You