B. A. T. Basic Appliance Training

Slides:



Advertisements
Similar presentations
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Advertisements

Residential Gas – Honeywell Valve - Thermopile Powered Series 300/301
Fired And Unfired Pressure Vessels
International Mechanical Codes Scald Protection. – Where a combination potable water-heating and space-heating system requires water for space.
HEAT PUMPS.
Refrigerators.
Student Book © 2004 Propane Education & Research CouncilPage Placing Appliances into Initial Operation Knowing the proper techniques and.
3.1.9 Student Book © 2004 Propane Education & Research CouncilPage Replacing Valves and Fittings in ASME Tanks Replacing ASME tank valves and fittings.
Safety Gas Plus.
1 THE LACLEDE GROUP Natural Gas Distribution Overview and Safety MISSOURI ONE CALL SYSTEM OPERATING COMMITTEE MEETING DECEMBER 19, 2013.
Heating Control Devices
Millivolt Troubleshooting Guide Gas Products NOVA SIT Valves 1) Thermocouple Millivolt Check 2) Safety Magnet Testing 3) Thermopile Millivolt Check 4)
1 Direct Fired Gas Heating Presented by Jim Jagers of Applied Air.
Student Book © 2004 Propane Education & Research CouncilPage Installing Vapor Meters Vapor meters are precision measuring devices that.
Environmental Health Issue- Carbon Monoxide Presented by QBE Loss Control Services.
Oxygen Concentrators.
11-1 Copyright  2010 McGraw-Hill Australia Pty Ltd PowerPoint slides to accompany Puffett, Hossack, Stone, Burn & Miles, Gasfitting 2e Chapter 11 OPERATION.
HVAC121 – Gas Heat Flame Rectification.
7.3.2 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components and Operating Characteristics of Electronic Ignition.
Gas Furnace Controls Part 4.
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
Natural Gas Pipeline Safety EDM Services, Inc. April 2009.
Fire safety is an important business. You need to take proper precaution in order to prevent a fire. Yes, fire may be inevitable but if prepared, you can.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 5 Validating Combustion Air.
California Friendly ® Landscape Training Irrigation System Troubleshooting The Metropolitan Water District of Southern California and the Family of Southern.
AccuMax Multi-Point Injection Mechanics
Carbon Monoxide Response Cole County Fire Protection District.
STEAM HEATING.
Electrical Electricity Fuses Relays Solenoids Electrical Testing
Pressure Switches. New modulating and multi-stage furnaces are more complex and require that installation instructions and procedures be followed so that.
Gas Furnace Planned Maintenance
MODULE 5 Complete and Incomplete Combustion Characteristics.
7.2.3 Student Book © 2005 Propane Education & Research CouncilPage Identifying Procedures for Measuring Resistance Between Two Given Points in.
BOILER PLANT OPERATION Presented By Mr. Sivanand Ray
NFPA 31 Standard for the installation of Oil- Burning Equipment
Placing Vapor Distribution Systems and Appliances into Operation MODULE 8 System Tests.
Student Book © 2004 Propane Education & Research CouncilPage Purging Vapor Distribution Lines & Appliances Purging is the controlled displacement.
Safety Training Presentation
Air Conditioning International Mechanical Code
7.3.5 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Function and Characteristics of Draft Fans & Controls High efficiency.
Placing Vapor Distribution Systems and Appliances into Operation MODULE 10 Spillage Test.
HVACR116 – Trade Skills Longest length method.
Furnace Safety. AS WEATHER TURNS COLDER, BE AWARE OF AN INVISIBLE KILLER THAT CAN SEEP THROUGH THE HOME, CAUSING SERIOUS INJURY OR DEATH.
Unit 4: General Safety Practices
Why Maintenance Tasks are Important Produced by Joe Marchese.
Student Book © 2004 Propane Education & Research CouncilPage Performing Gas Distribution System Leak Checks Requirements for vapor distribution.
Student Handout Packet – Page A7
3.0 Comprehensive Performance Audit Fossil Fuel Appliances Health & Safety 3.2.
Day 1 Part 4 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Piston Engine Propulsion Ignition. Ignition in a piston engine requires: Spark plugs Magneto Condensers Distributor Contact breakers electronic systems.
Process Safety Advisory on Boiler Incidents
E3 HVACR Controls and Devices
RV Safety Alarm Testing Procedures
Unit 13 Oil-Burning Equipment
Unit 7 Gas Heat: Natural and LP
Teknologi Dan Rekayasa
Using Gas Welding Equipment
Installing DOT/ICC Exchange or Stationary Cylinders
General Safety Practices
E3 HVACR Controls and Devices
Flammable and Combustible Liquids
Student CD for Commercial Refrigeration for A/C Technicians Chapter 12 Ice Machines.
RV Safety Alarms Education Test
Automotive Technology Principles, Diagnosis, and Service
Presentation transcript:

B. A. T. Basic Appliance Training Basic Gas Appliance Service presented by Jim Campbell, Mcap

Outline Gas Basics Fuel Gas Code Requirements Gas Testing Devices Safety Characteristics Fuel Gas Code Requirements Gas Testing Devices Gas Ranges Gas Dryers Gas Water Heaters

Gas Basics This program is not designed to give you all the necessary skills and information to service all gas appliances but will form a foundation to help build your skills and knowledge. Further information and experience will be necessary to completely understand all aspects of servicing gas products.

References NFPA 54 – National Fuel Gas Code NFPA 58 – Liquefied Petroleum Gas Code NFPA 501 & 501A – Standards for Manufactured Homes Various service guides & training programs from Gas Appliance manufacturers

Gas Basics - Safety For your personal Safety: Always use a combustible gas indicator to check for gas in the atmosphere as you enter the service area. Don’t trust your nose to warn you. Ask the customer if they have been smelling gas. Check high for Natural Gas, check low for LP Gas.

Gas Basics - Safety Combustible gas indicators (CGI)

Gas Basics - Safety Mops, brooms, newspapers or any flammable materials should not be stored near gas appliances. Paints, solvents, gasoline or any combustible products should not be in the same room.

Gas Basics - Safety Make sure a flexible gas line connection is installed connecting the gas houseline to the appliance to reduce the likelihood of damage if movement should occur. All gas appliances should have a gas shut-off valve installed in the gas line that lets you turn off the gas to that appliance if there is a gas leak.

Gas Basics - Safety Make yourself aware of where the main shut-off is or the gas meter / shut-off in case of any emergency while you are in the customer’s home. Main shut-off

Gas Basics – Safety Safe Servicing Practices Be sure to wear Safety Glasses and any other Personal Protection Equipment while performing service work. Before servicing or moving an appliance: Disconnect power Turn off the gas supply Turn off the water supply Be sure to exercise “Lock-Out / Tag-Out” procedures

Gas Basics - Safety NEVER interfere with the proper operation of any safety device. It is never acceptable to bypass a Safety or an operating control and leave the unit in operation. Use only replacement parts designed for that specific appliance. NO MacGyver-ing

Gas Basics - Safety Prior to returning an appliance to service: Make sure all electrical connections are correct and secure, dressed, away from sharp edges and moving parts and well insulated and protected from damage. See that access panels are securely reassembled and all screws back where they belong.

Gas Basics - Safety One of the major concerns when working on Gas Burning appliances is the production of CO (Carbon Monoxide). All Gas Burning appliances have the potential for creating CO.

Gas Basics - Safety Gas Burning appliances produce excessive CO if: Burners are not properly adjusted Flame impingement is occurring Improper venting Lack of air for complete combustion

Gas Basics – Safety Effects of CO Poisoning 9 ppm The maximum allowable concentration for short-term exposure in a living area according to ASHRAE. 35 ppm The maximum allowable concentration for continuous exposure in any eight-hour period, according to federal law. 200* ppm Slight headache, tiredness, dizziness, and nausea after two to three hours. 400 ppm Frontal headaches within one to two hours, life-threatening after three hours, also maximum parts per million in flue gas according to EPA and AGA. 800 ppm Dizziness, nausea, and convulsions within 45 minutes. Unconsciousness within two hours. Death within two to three hours. 1,600 ppm Headache, dizziness, and nausea within 20 minutes. Death within one hour. 3,200 ppm Headache, dizziness, and nausea within 5 to 10 minutes. Death within 30 minutes. 6,400 ppm Headache, dizziness, and nausea within 1 to 2 minutes. Death within 10 to 15 minutes. 12,800 ppm Death within 1 to 3 minutes. * Maximum CO concentration for exposure at any time as prescribed by OSHA. Effects can vary significantly based on age, sex, weight, and overall state of health.

Gas Basics - Safety The CPSC (Consumer Product Safety Commission) recommends that an approved CO detector be installed in every home. CO detectors should be mounted in and around the sleeping areas, not in a kitchen or near gas burning appliances.

Gas Basics - Characteristics

Gas Basics - Characteristics Natural Gas ratio Gas to Air 4% to 14% Propane ration Gas to Air 2% to 10%

Gas Appliance Testing Devices If you use Soap Solution when testing for leaks, you must clean it off to eliminate corrosion.

Gas Appliance Testing Devices - Manometers Manometers are primarily used to measure pressures of less than 1 PSI. If you use a spring gauge to check gas pressures, always check your spring gauge for accuracy by comparison to known pressures or a manometer. Manometers normally indicate pressures in “Inches of Water Column” (“wc).

Gas Appliance Testing Devices - Manometers How to read a manometer:

Gas Appliance Testing Devices - Manometers This is a commonly used Direct Read manometer. Upright mode for common measurements. Incline mode for pressures less than 1”wc

Fuel Gas Codes If you work on Gas burning appliances you should have the applicable code available to you National Fuel Gas Code – NFPA54 NFPA 501 & 501A – Standards for Manufactured Homes NFPA 58 – LP Code International Fuel Gas Code Local Jurisdiction codes

Fuel Gas Codes Fuel Gas Codes establish the bare minimum requirements for gas burning equipment: Installation Piping Connections to fuel system Combustion Air Requirements Venting

Fuel Gas Codes Appliances must have a shut-off valve within 6 feet of the appliance. Connectors must be approved connectors Primarily Stainless Steel or Coated connectors Appliances must be supplied with the required gas supply, pressure & quantity

Fuel Gas Codes The major concern when it comes to the gas burning appliances that we deal with; gas ranges, gas dryers and gas water heaters, is the amount of air available for proper combustion. Unless we go through exhaustive measures to determine the amount of infiltration air into the structure where the appliance is installed, we fall back on the minimum requirements for equipment.

Fuel Gas Codes The minimum amount of air required by Standard Method: The minimum required volume shall be 50ft3 / 1000 Btu / hr If we have a standard gas range with 4 surface burners and the two oven burners, bake and broil; it is rated for 65,000 Btus input, how much air is required? _________________ft3

Gas Ranges Gas ranges are different from Electric ranges because the heat comes from a gas flame instead of a heating element. Natural Gas is delivered to the range at approx. 7”wc. A regulator inside the range drops the pressure to a normal manifold pressure of 3.5 to 4”wc. Measuring the gas pressure would be done using a manometer or magnehelic gauge.

Gas Ranges The surface burners are supplied with gas through the burner valve

Gas Ranges Actual surface burner gas valve operation Burner adjustment

Gas Ranges Checking burners Which flame indicates proper combustion? A B C D

Gas Ranges Flame quenching – normally results in a complaint about odors. Customers may complain about gas odors or even CO. They are actually smelling the Aldehydes from incomplete combustion. Improper flame diagnostics Cleaning burners

Gas Ranges Gas burner ignition systems include: Standing pilot Spark (Electronic) ignition Hot Surface ignition Standing pilot, surface burners

Gas Ranges Relighting standing pilot Adjusting the pilot Ensure pilot is not too high, causes soot under pilot hood and creates Aldahydes Adjusting the pilot Turn the pilot up just enough to keep it lit Cleaning the pilot Never, Never use a broach to clean a pilot. A broach is a three sided file and will enlarge the pilot and cause problems. Use compressed air.

Gas Ranges Electronic ignition Consists of the following components: Ignitor switches Ignitor spark module Surface burner ignitors (electrodes) Ignitor switches for the surface burners are wired in parallel to each other.

Gas Ranges When the burner control is turned to “Lite”, the switch closes a 120 Volt circuit to an Electronic Spark Module. The module steps up the 120 Volt input to approximately 10,000 to 20,000 volts. The high voltage causes the current to jump from the electrode to ground.

Gas Ranges Spark Module and Spark Electrode

Gas Ranges Surface burner layout

Gas Ranges Sealed burner layout

Gas Ranges Types of Electronic ignition systems for surface burners: All burners spark & oven sparks One side of burners & oven independent One burner sparks & oven is independent Electronic ignition diagnostics Burners spark for no reason, middle of night.

Gas Ranges Oven ignition systems: Standing pilot Intermittent spark Hot Surface (Glow bar)

Gas Ranges Standing Pilot

Gas Ranges Oven Safety Valve Stand-by vs. Heater pilot

Gas Ranges Oven Safety Valve opening

Gas Ranges Hot Surface (Glo-Bar) Ignition, aka – HIS

Gas Ranges HSI operation 1 2 3

Gas Ranges Testing components Oven control Burner switches Limits May have to Choke it Burner switches Test for open and close Limits Should all be normally closed Locking mechanisms Are the switches in the correct positions Now what about this Choking thing?

Gas Ranges Testing components, Glo-Bar ignitors Either ignitor should read about 50 to 150 ohms resistance when cold. 2.5 to 3.0 Amps 3.0 to 3.6 Amps

Gas Ranges Testing oven temperature sensor

Gas Dryers Everything about Gas Dryers is the same as Electric Dryers except for the source of heat and Gas Dryers operate on 120 Volts instead of 240. Timers / PCB boards are about the same Thermostats are the same Pretty much the same except for the gas burner.

Gas Dryers Provides heat, either electric elements or gas burner. Circulates air Tumbles the clothes

Gas Dryers Natural gas is supplied to gas dryers at approx. 7”wc. A pressure regulator inside the dryer cuts that pressure down to an operating pressure of 3.5 to 4”wc. The gas is normally ignited with a hot surface ignitor.

Gas Dryers Gas dryer heating system. Burner Tube Gas Valve Inlet Operating Coils This Gas Valve assembly is referred to as a “K” series. The coils are wired.

Gas Dryers Gas dryer heating system. Hot Surface Ignitor

Gas Dryers Gas dryer heating system. Oven cone with High Limit Flame Sensor Operating Coils This Gas Valve assembly is referred to as an “M” series. The coils are modular plug-in instead of wired.

Gas Dryers Gas dryer heating system. Hot Surface Ignitor 120 Volt Power in

Gas Dryers Gas dryer heating system. N 1300  600  L1 700 

Gas Water Heaters

Gas Water Heaters Typical components

Gas Water Heater Power Vented Water Heater

Gas Water Heater Water Heater with FVIR

Gas Water Heater Troubleshooting Pilot outages Thermocouple Gas Valve FVIR system cleaning

Gas Water Heater

Gas Appliance Service For reference- Available by email: Email address: jim@repair2000.com Available by email: please put ( BAT training ) in the subject line: Whirlpool – Adjustments and Repairs to minimize CO emissions Frigidaire – Procedures for Repair and Adjustments to minimize CO GE – CO training manual Cleaning instructions for Sealed water heaters