HMIs Human Machine Interfaces.

Slides:



Advertisements
Similar presentations
1. XP 2 * The Web is a collection of files that reside on computers, called Web servers. * Web servers are connected to each other through the Internet.
Advertisements

Schutzvermerk nach DIN 34 beachten XControl XC100 + XI/OC I/O-Modules + XVision Text-Display The convincing machine and system control by Moeller XControl.
PMU (Programmable Monitoring Unit)
Yokogawa Network Solutions Presents:
SYNAPSE I.S. Ticket Sales & Management. SYNAPSE I.S. What is Olympia ? Olympia is NOT just another internet sales service. Olympia is a tool for the ticketing.
Copyright © 2012 Rockwell Automation, Inc. All rights reserved.Rev 5058-CO900C PanelView Plus 6 700/1000/1250/1500 Machine-level HMI Presenter Name Date.
PLC Selection, Components, and Communication
PC Technology Chapter 6 Teacher: Manju JEOPARDY.
Computer Buses Ref: Burd, Chp – 220 Englander, Chp 7 p
HARDWARE Rashedul Hasan..
Module 3 Configuring Hardware on a Computer Running Windows XP Professional.
TOP Server: Understanding Modbus for Device Connectivity
Automation and Drives SIMATIC HMI Human Machine Interface Panel_PC_remotemount_vee8_SH4213.ppt/ SIMATIC Panel PC remote mount SIMATIC Panel PC 670.
Samsung Digital Signage
SIMATIC HMI Panels Product Spectrum
DeviceNet 2400, 2500, 26/2700.
Windows XP Operating Systems  COSC513 Operating Systems  Mr. Nut Prommongkonkun  Student ID #
XP New Perspectives on Browser and Basics Tutorial 1 1 Browser and Basics Tutorial 1.
OPC and the 5000 Connections made even easier! Adrian Oliver iTools Development Team
Engineering Redefined
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
6000 Series Recorders. The Best Paperless Graphic Recorder in the World.
Efficient Management for Building Automation. Market Trend.
IDEC AUSTRALIA PTY LTD, UNIT 17, 104 FERNTREE GULLY RD, OAKLEIGH, VIC 3166 High Performance, Compact and Economical.
Sales Manual B.Braun Space
Multi Instruments Data Acquisition Software Evolution
SCADA Solutions.
Optimizing Windows Vista Performance Lesson 10. Skills Matrix Technology SkillObjective DomainObjective # Introducing ReadyBoostTroubleshoot performance.
Open-source SCADA systems Denis Ulybyshev SCADA Open Source Solutions By Denis Ulybyshev.
Copyright © 2002 Delmar Thomson Learning Chapter 3 Programming a Programmable Controller.
Introducing the ……... Chessell DAQ Series 5000.
2500 Series® HMI Panels.
eAutomation Enabler – Advantech Industrial NETworking
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
 COMPUTER & INDUSTRY LANGUAGE For Commercial Art.
RemoteDrive. OVERVIEW OVERVIEW The RemoteDrive is a special software running on Windows TM and controlling the devices manufactured by Elettronica Santerno.
Chapter-4 Windows 2000 Professional Win2K Professional provides a very usable interface and was designed for use in the desktop PC. Microsoft server system.
Introduction to Computers Personal Computing 10. What is a computer? Electronic device Performs instructions in a program Performs four functions –Accepts.
Industrial HMI Solution TOP
Chapter 7 AC 800M Hardware Course T314.
Schutzvermerk nach DIN 34 beachten XC200 Hardware Overview.
Who is Inner Range? Inner Range is an Australian Electronic Security Manufacturing Company. Established in 1988 with a Major focus on the Australian Security.
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
M340 Modbus Plus Proxy Link legacy systems to Ethernet
COMPUTER ARCHITECTURE. Recommended Text 1Computer Organization and Architecture by William Stallings 2Structured Computer Organisation Andrew S. Tanenbaum.
Yokogawa Electric Corporation Solution Marketing Gr., International Business Headquarters Copyright © Yokogawa Electric Corporation April 3, 2003-Rev2.
Chapter 3 Programming a Programmable Controller. Objectives Describe the available options for programming a PLC. Explain what online is in comparison.
© Paradigm Publishing, Inc. 4-1 Chapter 4 System Software Chapter 4 System Software.
CIMON TOUCH KDT SYSTEMS Introduction  Excellent Durability  The mobile CPU of the TOUCH gives excellent durability under industrial environment.
1 Syllabus at a glance – CMCN 6103 Introduction Introduction to Networking Network Fundamentals Number Systems Ethernet IP Addressing Subnetting ARP DNS.
Homework Explain these terms in your own words. If they are not your own words, they need to be in quotes with a source given. Sources 1.Wilson 2.Webopedia.
1 Chapter Overview Modems The Internet and Web Browsers.
TS8000 TS8000 Series HMI. Key Features Standard support for current SSD products. Support For Common third party Hardware. Programming software Included.
SEPTEMBER 8, 2015 Computer Hardware 1-1. HARDWARE TERMS CPU — Central Processing Unit RAM — Random-Access Memory  “random-access” means the CPU can read.
An Overview When Connecting to Yaskawa Drives Date: 8/14/06, Rev: PP.AFD.26.
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
October 2010 SmartAXIS Controller. High Performance, Compact and Economical.
Frequently Asked Questions (FAQ)
Basic Computer Hardware and Software.
OCS Configuration Software:
Basic Computer Hardware & Software
DT80 range Modbus capability
CP220x The Industry’s Smallest Ethernet Controller
Basic Computer Hardware and Software.
Identifying SLC 500™ System Components
HMI CP Range General Presentation.
TS8000 Series HMI.
Ethernet Gateway EGX200 - EGX400
Presentation transcript:

HMIs Human Machine Interfaces

Human Machine Interfaces Terminals Future MP+ TCP / IP Allen-Bradl Omro iemens Mitsubish n End

The E-series of HMIs E900VT E910 E900 E710 E700 E600 E300 E50 E200

E50 - low cost Background lit text display 2x16 4 function keys RS422 with RS232 in the same Dsub +5 VDC, external or from PLC Text blocks

E100 - small but strong Background lit text LCD-display 2 rows x 20 characters 4 function keys Text blocks Time channels Real-time clock Recipe handling RS-232C and RS-422 ports +5 VDC, external or from PLC 64 Kbytes flash memory Transparent mode HMI Tools support

E200 - As simple as it can be Background lit text LCD-display 4 rows x 20 characters, 5 mm text height 5 function keys 5 LEDs (two colour) Text blocks Time channels Real-time clock Recipe handling RS-232C and RS-422 ports 64 Kbytes flash memory Transparent mode HMI Tools support

E300 - Low-end graphic Background lit graphic LCD-display Two colours, 240 x 128 pixels 8 function keys 16 LEDs (two colour) Graphic and text blocks Time channels Real time trends Recipe handling RS-232C and RS-422 ports 1 expansion slot 128 Kbytes Flash memory, expandable to 8Mb Transparent mode HMI Tools and TCP/IP support

E600 - one step up Background lit graphic LCD-display Two colours, 240 x 128 pixels 16 function keys 16 LEDs (two colour) Graphic and text blocks Functionality as E300 Historical trends RS-232C and RS-422 ports 1 expansion slot 256 Kbytes Flash memory, expandable to 8Mb Transparent mode HMI Tools and TCP/IP support

E700 - A trend composer Background lit graphic LCD-display 256 colours, 320 x 240 pixels 16 function keys 14 LEDs (two colour) Graphic and text blocks Functionality as E600 RS-232C and RS-422 ports 2 expansion slots 400 Kbytes Flash memory, expandable to 8Mb Transparent mode HMI Tools support and TCP/IP support

E710 - with new hardware Background lit graphic touch LCD-display 256 colours, 320 x 240 pixels 8 function keys 8 LEDs (two color) Graphic and text blocks Functionality as E700 RS-232C and RS-422 ports 2 expansion slots 400 Kbytes Flash memory, expandable to 8Mb Transparent mode HMI Tools support and TCP/IP support

E900 - Even bigger Background lit graphic colour display 256 colours TFT, 640 x 480 pixels 22 function keys 20 LEDs (two colour) RS-232C and RS-422 ports 2 expansion slots 1.6 Mbytes Flash memory, expandable to 8Mb 220 VAC power supply Transparent mode HMI Tools and TCP/IP support

E910 - touch it! 24VDC version now available! Background lit graphic touch display 256 colours TFT, 10,4”, 640 x 480 pixels RS-232C and RS-422 ports 2 expansion slots 1.6 Mbytes Flash memory, expandable to 8Mb Dimensions 290 x 250 x 105 mm 220 VAC power supply Functionality as E900 24VDC version now available!

E900VT - more inputs... Background lit graphic TFT-display 256 colours, 10,4”, 640 x 480 pixel 22 + 28 function keys ( IFC-64E ) 20 two color + 28 green LEDs RS-232C and RS-422 ports 1 expansion slot 1.6 Mbytes Flash memory, expandable to 8Mb 220 VAC power supply Functionality as the E900

E610 - preliminary Touchversion of E600 B/W LCD display Compact Low price Release Q4 2000

Expansion cards Memory expansion with IFC-MC Increase project memory with up to 8Mb Back-up of recipes and projects Transfer of files to other terminals Profibus DP IFC-PBDP Slave connection to Profibus DP TCP/IP network IFC-ETTP, IFC-ETCX Terminal network and Internet enable via Ethernet

Expansion cards External function keys with IFC-128E For connection of up to 128 extra function-keys Parallel printer with IFC-PI For connection of an parallel printer A-bus interface IFC-GA (E900/E910 only) Direct connection to the A-bus

IFC-PI - Parallel printer port Print outs of graphic and text blocks, reports and alarm lists Graphics requires a HP PCL5, HP PCL6 or Epson FX80 compatible printer If IFC PI is used a printer can not be connected to the RS-232 port E300 and E600 have no support for HP PCL5/6 printers Black and white print outs only

IFC-PI - Parallel printer port Connectable to E300 version 4.0 or higher (only with Epson FX-80) E600 version 4.02 or higher (only with Epson FX-80) E700 version 4.0 or higher E710 version 4.0 or higher E900 version 1.01 or higher E910 version 4.02 or higher

IFC-GA - Direct bus connection With the expansion card, IFC-GA, and the bus-interface A7GT-BUS installed, you can connect the E900 and E910 terminals directly to the base unit on an A(nS)-system. The communication between the PLC and the terminal will be very effective with the IFC-GA, because the terminal communicates directly with the A-bus on the PLC. The standard RS-232/422 ports will be free for other equipment.

The new concept Before: Today: Project Project Driver Terminal code + Drivers Project Terminal code Driver Project Omron.dll Omron.hlp Omron.pdf

The new concept Downloadable drivers All terminals in the E series from version 4.0 The driver and the system program are separated in the terminal New drivers can be used without a update of MP+ Installation via Internet using MP+ or from floppy (first download from web) Current driver is automatically transferred to the terminal by MP+ New standard cables to new PLC systems Manual in pdf-format to each driver WEB

2 ports gives you freedom Transparent mode Communication with the PLC system via the terminal Mitsubishi Omron Matsushita No protocol mode - Communication with external units i.e. barcode readers Serial printer

Transparent mode Reach PLC through terminal in operation Online changes Easier troubleshooting GPP/WIN MM+

Are you an individual? Individual customised products - from simple panels to PC platforms Integration into your machine design Customised OEM products, your operator control concept in style and functionality What can we offer you: Individual design and front layout Modular Hardware Flexible Software We will implement your requirements - So You can be successfully in business Professionalism and competence is our name And You: Be an individual...

The lifecycle - Of a terminal... Even at the design stage we try to think in a long time perspective The choose of : Components Material Recycled Recycling Handling Transports Minimum And in the end... We take care of old used products, and sees that every part is handled in a minimum non-polluting way. As our contribution to the environment . ISO 14001

Do it the hard way... The usual information way Process/ Operator RUN STOP FWD REV Process/ Machine Operator

Or the easy way! HMI as information provider! The HMI-solution gives you: Information in a easy way The Information will be clear and in right time Easier to determine when changes occur Process/ Machine Operator HMI

You will save: Money Effective Flexible Simplicity Time Easy - Handle Quick - Learn Simple - Install Right information - In Right Time

Basic functions Alarm handling Recipe handling Realtime clock Time channels Trend diagram Password handling 6

Operator interface Text Graphic Colors Touch screen LEDs Functionkeys Printouts

Mac Programmer+ Easy to use Windows 95, 98, 2000 and NT Documentation Back-up Full support for Windows copy/paste Toolbox and ToolTips Multiple project can be open at the same time Compatible name list with MELSEC MEDOC and MELSEC MEDOC + Support for MXChange

Structure Using a tree structure when developing a project Ett projekt i MAC-terminalen byggs upp i en trädstruktur för att på ett enkelt sätt få översyn och kontroll på projektet nu och i framtiden Block 0 är huvudmeny Block 0 -989 är till för användaren En del block används av systemet (990-999)

Block manager Simplifying the handling of the blocks. Gives the engineer a visual overview how the project is created. Nyhet i MP+ 3.00. Man kan visa trädstrukturen på projektet, och lättare se hur blocken hänger ihop. För att skapa nya block finns en liten verktygslåda, med vanliga Windows symboler för nytt block, samt hopp av olika slag. Högerklick på musen ger ett meny val för att lägga till block samt inställningar i Block Manager.

Object based All object data is stored in the terminal The signals is configured directly in the object No PLC-programming is needed* Only the object´s which is viewed on the screen is updated * except Profibus

Downloadable drivers Now you are just a click from upgrading your drivers

The Internal Name list For easy changing of different PLC devices

Message library Manoeuvrable message objects 64 libraries can be manoeuvrable with 512 texts, 40 characters Values between 0-65535 can be linked with texts Medelandebibliotek

News in Mac Programmer+ 32-bit version to Windows 95, 98, 2000 and NT Supporting downloadable drivers Supporting TCP/IP network Installation from CD

News in Mac Programmer+ New configuration of peripheral units Acknowledge of individual alarms from the PLC system Alarm on the negative edge

More news! Modem handling in all terminals except E50 Call up with the terminal 10 different numbers stored in the terminal 1 number stored in the PLC system Larger size on the alarm text in E900 System monitor in E700, E710, E900 and E910

More news! Show terminal in text blocks Printing text strips to all terminals from MP+ Improved project documentation in print-outs Use terminal font in MP+ Cursor colour in the alarm list can be changed

And more…. Recipes sorted in alphabetic order Turning off printing from the PLC system to avoid conflicts when transparent mode is used Min- and max limits on numeric objects in graphic blocks The alarm group name can contain national characters New data formats HEX 16-bit, 32-bit BCD 16-bit, 32-bit Float without exponent

The Installation CD MAC Programmer+ 32-bit HMI Tools 32-bit All current drivers Manuals to all products E-series and MAC-series Expansion cards Installation manuals Drivers Floppy-copying of Full version, Demo and Transfer

New manuals New E-series manual New installation manual The same manual to all E-terminals and MP+ New installation manual The same manual to all E-terminals Enclosed with all terminals Separate manual to each driver Downloaded with the driver in MP+ All pdf-manuals are available at WEB-site and on installation CD

HMI Tools Windows 95, 98, 2000 and NT Transferring of recipes, trends and alarm lists Downloading of system programs Communication via modem MP+ Transfer is a separate program

Why choose an operator terminal from Mitsubishi? High Quality User friendly Functionality One Software for all terminals Possibility to upgrade the operating system High quality support And of course the openness

Support at the web http://www.mitsubishi.co.uk/automation Downloadable: Latest versions of software's Demo Projects Product news Drivers Manuals Manufacturer´s declarations Upcoming features Application examples FAQ http://www.mitsubishi.co.uk/automation http://www.e-terminals.com

The Open Concept Drivers & Connections Allen-Bradl Mitsubish iemens Omro n

Drivers Melsec A (C24*, CPU, E71** or Profibus DP**) Melsec A-bus (A-bus*) Melsec A CC-Link connection (AJ65BT-G4) Melsec FX (CPU or 485ADP*) Melsec QnA (QC24*, QCPU* or Profibus DP**) Freqrol FR-A/E Melservo MRJ2CS100 * Can not be used with E50 ** Can not be used with E50, E100 or E200

Drivers Siemens SIMATIC S5 (3964R/RK512*, PG-port* or Profibus DP**) SIMATIC S7 (3964R/RK512*, MPI*, PPI or Profibus DP**) * Can not be used with E50 ** Can not be used with E50, E100 or E200

Drivers ABB Allen-Bradley Control Techniques Delta Tau SattCon (Comli master*) Allen-Bradley Micrologix (DF1) SLC500 (DF1 or DH485**) Control Techniques Unidrive (ANSI*) Delta Tau PMAC, UMAC (ASCII*) Demonstration driver Internal in the HMI DVT Vision System SmartImage Sensor (ASCII or TCP/IP**) Festo/Beck IPC, FEC series (FXT CI*) GE Fanuc Series 90 (SNPX) Hitachi H Series (HCOM*) IAI SuperSEL (Serial*) * Can not be used with E50 ** Can not be used with E50, E100 or E200

Drivers Idec Klockner Moeller Koyo Matsushita Modicon Omron FA-1/2/Junior/Micro1 (FA-series 1:1 expanded*) FA-3 (FA series 1:1*) MICRO3/3C (Micro Computer Link) Klockner Moeller PS4 series (SUCOM-A*) Koyo Direct logic series (DirectNET* or K-sequence) Matsushita FP-series (MEWTOCOL-COM) Modicon All PLC types (Modbus master ASCII/RTU or Modbus slave RTU*) MXCC VLC (Serial* or Profibus DP**) Omron All PLC types (Hostlink) * Can not be used with E50 ** Can not be used with E50, E100 or E200

Drives … and more will come! SAIA SEW Eurodrive Telemecanique Toshiba PCD series (SBUS*) SEW Eurodrive Movidrive (Movilink*) Movidyn (Movidyn*) Movitrac (Movitrac*) Telemecanique TSK series (UniTelway*) Toshiba PROSEC T-series (Computer Link) VT100 Yaskawa MP9xx series (MemoBus master RTU*) … and more will come! * Can not be used with E50 ** Can not be used with E50, E100 or E200

How to make a connection Cable?

Mitsubishi - E71 driver PLC-program E71-profile The PLC-systems in Melsec A/QnA(S)-series via AJ71E71 or AJ71QE71 using the ASCII protocol. All E-series terminals can be used, with the exception of E100 and E200. Requires Ethernet card. TCP/IP or UDP/IP Server Client BDTP IFC-ETCX

Mitsubishi - MELSERVO All E-series terminals can be used MR-J2-C-S100 RS422 or RS232 connection Multidrop of up to 32 servos possible Read/Write all inverter parameters, digital/analog signals, alarm codes All E-series functionality available (text/graphic, trending, recipe, reporting, networking …)

Default station number Mitsubishi - MELSERVO Point-to-point RS-232 Default station number Multidrop RS-485 RS-422 Cable as drawing in the manual

FREQROL FR-A/FR-E All E-series terminals can be used FR-A and FR-E series RS422 or RS232 connection Multidrop of up to 32 inverters possible Read/Write all inverter parameters, digital/analog signals, alarm codes All E-series functionality available (text/graphic, trending, recipe, reporting, networking …)

Default station number FREQROL FR-A/FR-E Point-to-point RS-422 CAB-9 PU-Port PU-Port SC-FRPC RS-232 RJ45 Default station number Multidrop FR-A5NR RS-422 Cable as drawing in the manual

MXCC <-> E-series alt.1 PROFIBUS-DP connection E300-900 can be connected MXCC-program handles the HMI-profile

MXCC <-> E-series alt. 2 Serial connection MXCC-program (Profile) All E-series HMIs can be used Low price connection Survives NT-crash Terminal network through Ethernet possible RS232 I/O-bus Detta är lämpligen lösningen då PCn ej önskas placeras ute i processen utan att en/flera operatörspaneler räcker som HMI eller då inga lokala I/O finns i apparatskåpet utan alla I/O finns utspritt på maskinen el.dyl.

ABB - COMLI Master Supports multidrop CAB-8 RS-422 RS-485 Nod ID: Cable as drawing in the manual

Allen-Bradley DF1 Micrologix The PLC-systems in the Micrologix 1000-series CRC-16 checksum Full duplex This node = Terminal Remote node = PLC CAB-2 8-pol Mini-Din RS-232

Allen-Bradley DF1 SLC-500 The PLC-systems SLC 500, SLC 5/01, SLC 5/02, SLC 5/03 and SLC 5/04 Requires the module 1747-KE, 700 DEM (The DF1 connection at SLC 5/03 and SLC 5/04 is not recommended because of more disturbance) CRC-16 checksum Full duplex This node = Terminal Remote node = PLC DH-485 CAB-5 Cable 1747-C13 from Allen-Bradley RS-232

Control Technique - UNIDRIVE All E-series terminals can be used Inverters in the Unidrive series with serial interface i. e. UD 71. RS422 or RS232 connection Multidrop of up to 32 servos possible Read/Write all controllers parameters, digital/analog signals, alarm codes All E-series functionality available (text/graphic, trending, recipe, reporting, networking …)

Control Technique - UNIDRIVE Point-to-point RS-422 Default station number RS-485 CAB-8 CAB8 Multidrop RS-422 2-wire 4-wire RS-422 RS-422 Cable as drawing in the manual

Delta Tau - PMAC/UMAC All E-series terminals can be used RS422 or RS232 connection Point to Point or Multidrop Read/Write all controllers parameters, digital/analog signals, alarm codes All E-series functionality available (text/graphic, trending, recipe, reporting, networking …)

Default station number Delta Tau - PMAC/UMAC The Positioning-system in Delta Tau PMAC/UMAC-series Default station number MAC 40+-CAB RS-422 Multidrop is performed by a band cable between the PMAC/UMAC systems

Demonstration driver Driver for demonstration without PLC-system 99 M-coils 99 data registers 4 counters 4 timers

GE Fanuc SNPX The terminals supports all GE Fanuc PLC systems, connected via the SNPX protocol. SNP ID number No PLC-program requires for the communication CAB-4 RS-422

Idec - FA series The PLC-systems in Idec FA-series RS-422 RS-422 8-pol connector RJ11 RS-422 RS-422 Cable as drawing in the manual Contain electronically devices, se driver manual

Default station number Idec - Micro 3-series The PLC-systems in Idec Micro 3-series Default station number 8-pol Mini-din RS-485 CAB-8 CAB8 I Alt. RS-422 RS-232 Cable as drawing in the manual

Koyo - DirecNet & K-Sequence Koyo Direct Logic Series K-Sequence PLC Koyo via the DirectNET Default station number 15-pol RJ12 RS-422 RS-232 RS-232 Cable as drawing in the manual

Default station number Matsushita - FP series The PLC-systems in Matsushita FP-series via the MEWTOCOL-COM protocol Default station number 15-pol 9-pol 5-pol Mini-Din RS-422 RS-232 RS-232 Cable as drawing in the manual

Default station number Modbus ASCII / RTU Supports Multidrop Default station number CAB-8 CAB8 RS-422 RS-485 Cable as drawing in the manual

Default station number Omron Hostlink The terminals supports all Omron PLC systems, connected via the Hostlink protocol. Supports transparent mode Default station number No PLC-program requires for the communication CAB-3 RS-232

Siemens SIMATIC S5 PG1/AS511 The PLC-systems SIMATIC S5 90, 115, 135 and 155 No PLC-program requires for the communication CAB-7 CAB-1 Siemens Converter 6ES5 734-1BD20 RS-232 RS-422

Higher priority=Master Siemens SIMATIC S5 3964R/RK512 The PLC-systems SIMATIC S5 90, 115, 135 and 155 Requires communication card CP525 Writing is only possible to DB, other devices can only be read The terminal Higher priority=Master PLC 3964R / RK512=Slave CAB-6 RS-422 Null modem RS-232 CAB-5

Siemens SIMATIC S5 Profibus DP The PLC-systems SIMATIC S5 90, 115, 135 and 155 Requires Profibus DP interface (IFC-PBDP) IFC-PBDP PLC program HMI-profile Requires timedelay in connection with fast CPU:s

Siemens SIMATIC S7 MPI The PLC-systems SIMATIC S7 300- and 400-series The MPI station number of the terminal The MPI stationnumber of the PLC system Highest MPI address CAB-6 CAB-11 RS-422 + CAB-5 RS-232

Siemens SIMATIC S7 PPI The PLC-systems SIMATIC S7 200-series The station number of the terminal The stationnumber of the PLC-system Highest PPI address Only the terminal can be Master in the network PPI-Port CAB-8 RS-422 Cable as drawing in the manual

Siemens SIMATIC S7 3964R/RK512 The PLC-systems SIMATIC S7 300- and 400-series Requires communication card CP341 Writing is only possible to DB, other devices can only be read The terminal Higher priority Master PLC 3964R/RK512 Slave CAB-5 RS-232

Siemens SIMATIC S7 Profibus DP The PLC-systems SIMATIC S7 300- and 400-series Requires Profibus DP interface (IFC-PBDP) IFC-PBDP PLC-program HMI-profile

Default station number Toshiba The PLC-systems in PROSEC T-series via Multidrop connection Default station number The Computer Link protocol RS-232 RS-485 RS-485 RS-485 RS-422 MAC30/40-CAB CR-01 RS-422 CR-01 Cable as drawing in the manual

Cables CAB1 cable to connect Siemens SIMATIC S5/PG1 via Siemens Converter to the RS-232-port on the terminals in the E-series. 0,5 m. CAB2 cable to connect Allen-Bradley's PLC system Micrologix to the RS-232-port on the terminals in the E-series. 3 m. CAB3 cable to connect Omron PLC system via the Hostlink protocol to the RS-232-port on the terminals in the E-series. 3 m.

Cables CAB4 cable to connect GE Fanuc PLC system via the SNPX protocol to the RS-422-port on the terminals in the E-series. 3 m. CAB5 cable to connect Siemens SIMATIC S7/MPI via Siemens HMI Adapter, Siemens SIMATIC S7/3964R, Siemens SIMATIC S5/3964R and Allen-Bradley/DF1 PLC-systems to the RS-232-port on the terminals in the E-series and to connect a PC to the RS-232-port on the terminals in the E-series. (MAC PROG/9-CAB) 3 m.

Cables CAB6 cable to connect Siemens SIMATIC S7/MPI via Siemens HMI Adapter, Siemens SIMATIC S5/3964R and PC to the RS-422-port on the terminals in the E-series. 3 m. CAB7 cable to connect Siemens SIMATIC S5/PG1 straight to the RS-422-port on the terminals in the E-series. 3 m.

Cables CAB8 to connect the terminals in the E-series to PLC-systems via RS-485. Adapter placed on the RS-422-port at the terminals. CAB9 cable to connect Mitsubishi Fr-A / E inverters straight to the RS-422-port on the terminals in the E-series. 3 m.

2 serial ports gives you freedom Transparent mode Communication with the PLC system via the terminal, online No protocol mode Communication with external units Serial Printer Communication with a serial printer ? Controller

The Communication ”Point to point”, master/slave Terminal read/write information. PLC replys on requested information. Signals which effects the communication time Overhead signals except signals in the current block. alarms, trends, display-signals, LED-registers, block-prints, index, register for PLC-watch etc. Message packet

The Communication Signals which NOT effects the communication time Signals connected to function keys, time channels, objects in alarm texts. Effective communication = (as few message packets as possible) Group signals. Don’t dump the watch with to short interval. Block change with display register. Packaging of signals (consecutive order). Message packet

The future requires new concepts New concepts reach new markets - new markets gives us new customers Openness is one key to the future More effective development work Even higher quality

PC-based HMI functionality The HMI strategy Internet technology More openness PC-based HMI functionality Windows CE More efficient tools High functionality Easy handling Optimized for Mitsubishi Electric products

Future customer requirements * Supervisory connectivity - Remote HMI/PLC process monitoring/control - Diagnostics - Statistic reporting - Internet connection - Data file exchange * Flexible HMI application - Data exchange with Word, VB, Excel. - Reuse of objects - More options for advanced users * Plant floor connectivity - All major PLC:s - PC-based control systems - Fieldbuses - Local networks * OPEN STANDARDS ! - TCP/IP-Ethernet. - Windows CE/NT/95 - OPC, ActiveX, COM/DCOM - Internet technology

CEZAR Product hierarchy SCADA system Operator terminals - Graphic - Text CEZAR

CEZAR concept Same concept-different platforms C-terminals Desktop Microsoft® Windows CE® Microsoft® Windows NT® C-terminals Adaptions for NT / NT-E / CE environment Desktop Adaptions for NT environment

CEZAR concept The CEZAR-RT and the CEZAR software will check if all the necessary components exist on the target platform. If not, they will be distributed automatically by the software. CEZAR Developing tool C-Terminal Any PC CEZAR-RT ( TCA* ) CEZAR-RT ( TCA ) The Terminal Client Application is always included in the C-terminals *The Terminal Client Application must be purchased separate

Basic functions Alarm handling Recipe handling Real-time clock Time channels Trend diagrams Password handling 6

Operator interface Text Graphic/Pictures Colours Touch screen 125º Text Graphic/Pictures Colours Touch screen Print-outs Possibility to start other Windows applications

CEZAR developing tool Three selectable user levels: 3. Enterprise 2. Professional 1. Basic Three selectable user levels: Event driven programming (level 2-3) Programming with Visual Basic-script (level 3) Drag n’ Drop ActiveX controls Copy/Paste from Windows

Improved HMI functionality (1) Data exchange with... Script language using… Extended character support - Unicode - True Type Fonts Multimedia support - Video - Sound

Improved HMI functionality (2) Internet access Web Server - Allow access from other sites Web Client - Get data from other sites Network possibilities Distributed objects Shared data files (alarm list, application) Network with NT-stations

Open system Microsoft technology: Objects based: OPC - allows for 3.rd party drivers COM/ActiveX - object component base DCOM - distributed objects Objects based: Object accessible from external applications Reuse of objects Customer can create new objects

How many inputs do You have? CEZAR Connections How many inputs do You have? USB-Ports 2 x USB Parallell-Port Ethernet-Port TP with RJ45 Serial-Ports 1 x RS422 2 x RS232 Support for Multiple drivers

Hardware specification NT (1) Intel/Pentium MMX 266 processor 12.1” Touch TFT display, 800*600, 256 K colours C&T 69000, 2MB SDRAM video Chips 64 MB RAM memory, expandable to 128 MB 6.1 GB hard drive , 2.5", EIDE 2 x USB ports 2 x RS-232 ports RS-422 Microsoft® Windows NT®

Hardware specification NT (2) Parallel port Ethernet TP 100M, RJ-45 connector 32 bit PCI slot, 2 brackets 2 x 16 bit PC104 slot, stacked Keyboard, Mouse and sound* connectors Microsoft® Windows NT® * Optional

Future developments

Development areas More E-series drivers will still come Strengthen low-end area of E-series EX classified environment Integration of Internet-technology Use the benefits from Windows CE and NT And...

The HMI WEB THE NET

Overview TCP/IP network Functionality Terminal network, replacing MAC network, 10Mbit/s Transfer data between PLC-systems Project transfer More will come ... Connection possibilities Ethernet Twisted Pair or coaxial Serial New expansion cards IFC ETTP, Twisted Pair IFC ETCX, Coaxial Server Client Server/Client BDTP

Overview TCP/IP network - twisted pair IFC ETTP in each terminal Maximum length between terminal and HUB is 100 m Twisted pair CAT5, shielded or not shielded RJ45 connector The number of connections on the HUB settles the maximum number of terminals connected to each HUB No HUB if only two terminals

Overview TCP/IP network - coaxial cable IFC ETCX in each terminal Maximum length on each segment is 185 m Maximum 30 units on each segment Maximum 5 segments can be connected via repeaters and maximum 3 segments can have units Coaxial cable RG58 Termination 50  Segment

BDTP improvements in version 5 Server Alarms - Define the alarm in the server, this will be sent to all the clients automatically when the signal is activated. RAS* functionality Automatic restart of clients when server restart. * Recovery Automatically System

Available now! TCP/IP - step 2 Intranet / Internet connection Remote monitoring/Maneuvering Via web-sites Free Browser Data transfer FTP transfer E-mail SMTP

Local connections Intranet Call-up Intranet Local factory network Good response time Local domains Call-up Intranet World-wide access Good response time Local domains

Global connection - www Internet Published on the WEB. Uncertain response time. Global domains. Mainly for data of public interest.

WEB server HTML Each terminal has a homepage. Standard Web Browser (Internet Explorer, Netscape Navigator) W.W.W. Each terminal has a homepage. HTML-pages can contain real-time and PLC/HMI-data HTML-pages are created on PC and downloaded to the terminal WEB Server HTML blablablabbl HTML blablablabbl HTML <ssi> -------l -----

WEB server - remote Monitoring/Manoeuvring and Control W.W.W.

WEB server - remote Monitoring/Manoeuvring and Control W.W.W.

HTML codes User HTML-pages with SSI-code Standard Web Browser (Internet Explorer, Netscape Navigator) W.W.W. User HTML-pages with SSI-code <-!get_date.fn-!-> <-!get_time.fn-!-> <-!get_diag.fn-!-> <-!get_ipaddr.fn-!-> <-!get_domainname.fn-!-> <-!get_mode.fn-!-> <-!get_device.fn-!-> Function executed when server sees special codes

HTML codes User HTML-pages with CGI-Scripts <-!set_date.fn-!-> Standard Web Browser (Internet Explorer, Netscape Navigator) W.W.W. User HTML-pages with CGI-Scripts <-!set_date.fn-!-> <-!get_time.fn-!-> <-!set_mode.fn-!-> <-!set_device.fn-!->

HTML codes

WEB server - remote Monitoring/Manoeuvring and Control W.W.W. Standard Web Browser (Internet Explorer, Netscape Navigator) JAVA Applet View current screen of terminal Remote control terminal by mouse clicks on PC

WEB server - remote Monitoring/Manoeuvring and Control W.W.W.

FTP server - data transfer W.W.W. Process data transfer Recipes log / Trend data Alarm list Application data transfer HTML files Standard FTP client (Included in Internet Explorer, Netscape Navigator) FTP Server

Transparent mode Reach PLC through network W.W.W. GPP/WIN (2001) MM+ (April 2001) Reach PLC through network Requires support from PLC configuration software Tunneling PLC-protocols

You have mail... Mail on alarm Reports through e-mail (textblock) W.W.W. Outlook Express/Netscape.(POP3) Can redirect mails to f.ex GSM texts Mail on alarm Reports through e-mail (textblock) Forwarding E-mails Standard POP3 Mail server SMTP Client

GOT Product line up F900GOT A900GOT GOT Software

F900GOT Range F940GOT F930GOT-BWD-E F940GOT-LWD-E Monochrome F940GOT-SWD-E 8 colours F930GOT-BWD-E Monochrome

F900GOT functions Touch screen with IP66F(F940GOT) Security function 1:n Network Transparent Mode Alarm function Recipe function Device Monitor Graphical and Text-Objects F940GOT replaces and contains all functions of FX-50DU-TK(S)-E

Communication connections FX1, FX2, FX2C, FX0, FX0S, FX0N, FX2N,FX2NC Q/A series OMRON SYSMAC C series FUJI N series PC board PLC CPU direct connection CPU direct, PC link CPU direct, RS232C RS232C Connection method PC link Allen-Bradley PLC SLC500 series * Connection to Siemens PLC is also planned.

F930GOT-BWD-E Dimensions 146 mm 49 mm 75 mm Display size : 4.4-inch (280 x 80 dots) Display colour: 2-colour (blue/white) Display device: STN Touch switches: 4 x 15 = 60 (50 positions/screen can be set.)

F930GOT benefits Small and Compact high performance GOT Dimensional analysis: Outer dimensions: 146 x 75mm Depth: 49mm (45mm recessed into panel) High resolution / Industry’s Premiere Resolution The 240 x 80-dot screen (15 x 5 lines) provides the industry’s highest resolution in the small-class display category. Long-Life Backlight / Industry’s Longest Lasting Backlight. A full 50,000 hours of operation with a single Backlight. This long-life Backlight offers maintenance-free operation.

F930GOT benefits Quick One-Touch Switching The FX2N and FX2NC series connected (direct CPU connection) One-touch operations are conducted in 0.16sec with high-speed response. Simple Multiple Connectivity (up to 4 GOTs maximum) Using direct CPU connections with the MELSEC FX or A Series A maximum of 4 F930GOTs can be connected to a sequencer.

F930GOT-BWD-E IP66F Rating 146 x 75 x 49mm- classed as the worlds smallest control unit. Easier on the eyes than any comparable screen on the market. Easy-to-read wide-angle LCD. Network expansion a standard feature for up to four units. Sampling mode for measurements and recording.

Networking Hardware Terminal Network with up to 4 stations possible Transparent mode Main control panel remote‚P remote‚Q remote‚R remote‚S 30m 15m RS422 RS232C PLC

F940GOT Display properties 320 x 240 Pixel STN LCD 8 colours or Monochrome Excellent view from all angles 45° 60° 50°

F940GOT Dimensions Compact size Display 5.7In 162 115 23.5 Frame 130 85 22.5 22.5(Frame) 57 5.7in Terminal with less Dimension Water and oil resistent IP66F!

Comparison of terminals Category Touch keys Parameters Lamps Memory Freq. Varieties Display mode Trigger Alarm FX-50DU-TKS F940GOT Sampling History 32 Number 50 I/O 30 2,000 Dust/Water/Oil IP65 IP65F 128K 512K 256 Same +Oil resist. 800 200 1,000 2 4 x 2.5 Comparison x 1.6 x 1.7 x 4 x 5.1 x 5 x 2

Mitsubishi’s new GOT’s A900GOT series A985GOT-TBA-EU 256 colours 800x600 Pixel TFT 12” A975GOT-TBA-B-EU 256 colours 640x480 Pixel TFT 10,4“ A970GOT-SBA-B-EU 16 colours 640x480 Pixel STN 10,4“ A960GOT-EBA-EU Monochrome 640x400 Pixel EL 8,9“

Introducing A900GOT High speed screen data transfers and OS transfers. also store screen data from a GOT in a memory card (PCMCIA) and then edit to a PC List program edit function minor modification can be made on site compatible with MELSEC-A Series command list offers to write, monitor, insert, delete and parameter edit functions

Improved recipe handler Data 1 Data 2 Data 3 Data m Recipe data 1 D101 D102 D103 D*** Programmable controller m=Max. 8k words Recipe data 2 n =Max. 256 Commercial SRAM card or flash PC card Recipe data n

Bus connection and Recipes Fast Bus Connections use a MELSEC-A/QnA programmable controller for the fastest bus connection. You can achieve similar performance from three GOTs connected by bus as from a single connected GOT high speed response via a bus connection for cyclic communication Recipe functions data can be stored onto memory cards useable by other GOTs Mem. card Recipes

A900GOT Security Security functions 16 security levels Password input

A900GOT Communication speed Bus connection is fastest

A900GOT dimensions Extremely slim and compact Slim line terminal using new Bus or RS422 communication modules 46mm Size (W x H x D): 297 x 208 x 46 for colour Terminals 268 x 192 x 49 for EL Terminal

Connections A9GT-BUSS A9GT-RS4 PCMCIA card (withQnA series) Bus connection A9GT-RS4 Serial connection PCMCIA card (withQnA series) Memory cards for programs and recipe

PLC connection PLC Connection method FX1, FX2, FX2C, FX0, FX0S, FX0N, FX2N, FX2NC CPU direct communication Q/A series CPU direct, PC link, A-Bus and Networks. Allen-Bradley PLC SLC500 series RS232C OMRON SYSMAC C series Yasukawa series PC link

GOT Software GT Works, one Software for all GOT (AGOT and FGOT) (SWnD5C-GOTRE-E) FX-DU-SW-WIN-E (Ver.2.30) only for FGOT F900 GOT DU GOT FX-DU-WIN-SW-E SW4D5C-GOTRE-SW Common

GT Works Converter for old projects Documentation function Improved help function Debug function Project manager Templates and tool bar Expanded libraries Simulation Tools

GOT Software Compatibility A900GOT and A870GOT Compatibility FX-50DU-TKS and F940GOT GOT900 screen data GOT800 screen data Convertor FX-DU-WIN-SW FX-50DU-TKS F940GOT

Human Machine Interfaces Questions?

HMIs Human Machine Interfaces