Frenger “Radiant” chilled beam performance at 1 Shelly St - Sydney

Slides:



Advertisements
Similar presentations
HVAC 13a CNST 305 Environmental Systems 1 Dr. Berryman
Advertisements

Chapter 3. HVAC Delivery Systems
HVAC Basics Bin Yan HVAC – Heating, Ventilation, Air-conditioning.
Institute of Energy and Sustainable Development HVAC S YSTEMS E NERGY D EMAND VS. B UILDING E NERGY D EMAND I VAN K OROLIJA I NSTITUTE OF E NERGY AND S.
HEALTHCARE BUILDING AUTOMATION
Commercial Mechanical Requirements
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Foundations of Real Estate Management BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building ®
Foundations of Real Estate Management TM BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building.
Mechanical Engineering Department  Temperature Control  Cooling  Heating  Humidity Control  Humidification  Dehumidification  Air Quality Control.
Chilled Beam Presentation
Lecture 23: Primary System Loops and Components Material prepared by GARD Analytics, Inc. and University of Illinois at Urbana-Champaign under contract.
Objectives Finish with ducts and fans Define project topics.
Energy in Focus Energy Savings with Water Based Systems By Maija Virta Specialist of Indoor Environment Technology.
Presented by: Terry Stohs Viessmann Manufacturing Company Inc.
Engineer Presentation
Energy Saving DDC Control Strategies
Active beams versus VAV with Reheat Analysis of May 2013 ASHRAE Journal article Ken Loudermilk Vice President, Technology & Developement.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
Objectives Review/Learn about HVAC Configurations Describing systems and processes in the psychrometric chart Analyze processes in AHU and buildings –Finish.
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
Lecture 15: Air Primary Loops and Controls Material prepared by GARD Analytics, Inc. and University of Illinois at Urbana-Champaign under contract to the.
Lecture Objectives: Model HVAC Systems –HW3 Asignemnet Learn about eQUEST software –How to conduct parametric analysis of building envelope.
Lecture Objectives: Final discussion about HW3 Introduce more final project topics Continue with HVAC Systems.
Lecture Objectives: Model processes in AHU –Use eQUEST predefined models –Use detail modeling Define your topics for your final project.
Static Pressure Control Loop The purpose of the static pressure control loop is to maintain an optimal static pressure in the ductwork. The control loop.
Lecture 16: Zone Air Paths and Air Distribution Units
Equation solvers Matlab Free versions / open source codes: –Scilab MathCad: Mathematica:
Important variables Water: Air: Conversion:
Announcements Midterm Project Prepare groups of 3 to 4 students You can submit the list at the end of next class Midterm Exam 03/09/10 - In class Exam:
1 Medical Office Building. 2 Occupancy – 400 persons 8 a.m. – 5 p.m. Monday - Friday Building Characteristics Three stories 40,000 square feet (200’ x.
Lecture Objectives: Finish with HVAC Systems Discuss Final Project.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
Objectives Analyze processes in AHU and buildings.
Lecture Objectives: Clarify issues related to eQUEST –for midterm project Learn more about various HVAC - economizer - heat recovery Discuss about the.
Malory J. Faust ∙ Mechanical Option ∙ Senior Thesis 2007.
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
Lecture Objectives: Discuss the exam problems Answer question about HW 3 and Final Project Assignments Building-System-Plant connection –HVAC Systems.
Lecture Objectives: Differences in Conduction Calculation in Various Energy Simulation Programs Modeling of HVAC Systems.
Objectives Propose residential system related final project –Compare VAV systems with DOAS systems.
HCB 3-Chap 19A: All-Air Systems_Single Zone 1 Chapter 19A: ALL-AIR SYSTEMS: SINGLE ZONE AND SINGLE DUCT Agami Reddy (July 2016) 1)Introduction and common.
Field Trip Time: Tomorrow (Tuesday) 8 am Duration 1 hour (you will be back latest at 10 am) Location Texas State University: Round Rock
Design & Analysis of Psychrometric Processes Various ways of Generating A Comfort… BY P M V Subbarao Associate Professor Mechanical Engineering Department.
LEVEL 4 BUILDING SERVICES TRAINING Level 3 Re-cap Cooling Systems looked at within Level 3 included; –Through-the-wall packages –Individual reversible.
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Lecture Objectives: Discuss Final Project
Objectives Finish analysis of most common HVAC Systems
HVAC Basics Arkan Arzesh HVAC – Heating, Ventilation, Air-conditioning.
Types of HVAC Technology Used in Business Establishments
Lecture Objectives: Answer questions related to HW 4
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Munters DOAS, Chilled Beams and VRV
Lecture Objectives: Answer questions related to HW 4
Energy Efficiency in District Coiling System
Brian Wallingford, Applications Engineer
Chilled Beam Performance:
Objectives Humidifying - steam - adiabatic Cooling towers
Roof Top Unit Overview (MAGNUM)
HCB 3-Chap 19A: All-Air Systems_Single Zone
Objectives AHU processes - HW2 Cooling cycles.
Case Study: Marks & Spencer Oxford Street
Lecture Objectives: Discuss HW4 parts
Project Overview Carrying out a 90.1 Appendix G Project
Objectives Finish with Heat exchangers
Objectives Psychometrics Examples in AHUs.
Announcements Exam 1 Next Class (Thursday, March 14th):
Objective Revie the Cooling Cycle Learn about air distribution systems
Objectives Processes in Cooling towers and AHUs.
Presentation transcript:

Frenger “Radiant” chilled beam performance at 1 Shelly St - Sydney Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... Frenger “Radiant” chilled beam performance at 1 Shelly St - Sydney 1

State of the art building simulation software... Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... 3D Model Creation 1 Shelly St - Sydney 2

State of the art building simulation software... Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... Daylight Analysis 1 Shelly St - Sydney 3

Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... Comparison of the performance of various HVAC systems at 1 Shelly St, Sydney VAV fancoil Active chilled beam Passive chilled beam (95% convective / 5% radiant absorption) Passive “Radiant” chilled beam (65% convective / 35% radiant absorption) Traditional VAV Modern VAV (temperature and CO2 control with “static reset”) 1 Shelly St - Sydney 4

Systems Setup – Cooling Circuit Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... Systems Setup – Cooling Circuit Cooling circuit (common to all air side systems) Chiller has a COP of 4 (typical chiller performance based on flow of 6°C and return temp of 12°C). Addition of Dry Air Cooler for free cooling when available. DAC efficiency = 67%, SFP of fans = 0.4W/l/s 1 Shelly St - Sydney 5

Systems Setup – Heating Circuit Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... Systems Setup – Heating Circuit Heating circuit (common to all air side systems) Boiler has an efficiency of 90% and a flow set point of 65°C. DHWS also fed from this circuit. 1 Shelly St - Sydney 6

Systems Setup – DX Circuit Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... Systems Setup – DX Circuit DX circuit - common to all air side systems Nominal heating energy input ratio 0.261 (COP = 3.83) Nominal cooling energy input ratio 0.307 (COP = 3.26) (Performance taken from typical Mitsubishi VRF heat recovery unit) 1 Shelly St - Sydney 7

Systems Setup – VAV Fancoil Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... Systems Setup – VAV Fancoil VAV fancoil air side A high efficiency chiller supplies chilled water at 6°C to the fan coils with a nominal return temperature of 12°C. An air source heat pump supplies heating and cooling to the DX coils in the AHU The AHU is based on a total SFP of 1.8 W/l/s and includes heat recovery at 75% efficiency and provides air to the fan coil units at 14°C. The fresh air flow rate is 2.2 l/s/m2 for perimeter zones and 1.1 l/s/m2 for core zones. The fan coil units include EC motors and VAV control and have an SFP of 0.25 W/l/s. The fan coil units have a minimum flow turndown to 60% of the maximum flow rate. 1 Shelly St - Sydney 8

Systems Setup – Active Chilled Beam Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... Systems Setup – Active Chilled Beam Active chilled beam air side A dedicated high efficiency chiller supplies 14°C water to the chilled beams; the chiller incorporates a "Free Cooling" circuit so that when the outdoor conditions permit the chiller can turn off. During other times the free cooling runs in conjunction with the chiller to further reduce energy usage. The pump speed is varied to ensure the chilled water return is 3K higher than the supply. A DX cooling coil provides the conditioned air at 16°C but also provides sufficient dehumidification of the supply air, to ensure latent gains within the space are controlled and maintains the dew point at 1.0°C lower than the chilled water flow temperature onto the beams. A DX heating coil provides the conditioned air at 13°C and supplies reheat during dehumidification. The AHU is based on a total SFP of 1.8 W/l/s and includes heat recovery at 75% efficiency. The fresh air flow rate is 2.2 l/s/m2 for perimeter zones and 1.1 l/s/m2 for core zones. 1 Shelly St - Sydney 9

Systems Setup – Passive Chilled Beam Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... Systems Setup – Passive Chilled Beam Passive chilled beam air side system (common to both radiant and / convective) Two passive chilled beam systems were modelled; one with a 5% radiant proportion and one with a 35% radiant proportion. The room thermostat setpoint for cooling was increased by 1°C for the 35% radiant case, to compensate for the lower resultant temperatures. A dedicated high efficiency chiller supplies 15°C water to the chilled beams; the chiller incorporates a "Free Cooling" circuit so that when the outdoor conditions permit the chiller can turn off. During other times the free cooling runs in conjunction with the chiller to further reduce energy usage. The pump speed is varied to ensure the chilled water return is 3K higher than the supply. A DX cooling coil provides the conditioned air at 16°C but also provides sufficient dehumidification of the supply air, to ensure latent gains within the space are controlled and maintains the dew point at 1.0°C lower than the chilled water flow temperature onto the beams. A DX heating coil provides the conditioned air at 16°C and supplies reheat during dehumidification. The AHU is based on a total SFP of 1.8 W/l/s and includes heat recovery at 75% efficiency. The fresh air flow rate is 2.2 l/s/m2 for perimeter zones and 1.1 l/s/m2 for core zones. 1 Shelly St - Sydney 10

Systems Setup – Traditional VAV Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... Systems Setup – Traditional VAV Traditional VAV air side A high efficiency chiller supplies chilled water at 6°C to the cooling coil with a nominal return temperature of 12°C. The VAV system is based on a total SFP of 1.8 W/l/s and includes heat recovery at 75% efficiency and provide air to the zones to meet the heating and cooling demands. The fresh air flow rate is 2.2 l/s/m2 for perimeter zones and 1.1 l/s/m2 for core zones. The zone dampers are set up to control air flow based on zone temperature requirements. The supply fan is controlled to maintain a constant static pressure. 1 Shelly St - Sydney 11

Systems Setup – Modern VAV Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... Systems Setup – Modern VAV Modern VAV air side A high efficiency chiller supplies chilled water at 6°C to the cooling coils with a nominal return temperature of 12°C. The VAV system is based on a total SFP of 1.8 W/l/s and includes heat recovery at 75% efficiency and provide air to the zones based on heating and cooling demand. The fresh air flow rate is 2.2 l/s/m2 for perimeter zones and 1.1 l/s/m2 for core zones. The zone dampers are set up to control air flow based on zone temperature requirements and CO2 levels. The supply and return fans are controlled to give “static pressure reset” as described in Ashrae 90.1. 1 Shelly St - Sydney 12

Systems Setup – Frenger ‘Radiant’ Chilled Beam (A) Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... Systems Setup – Frenger ‘Radiant’ Chilled Beam (A) Passive chilled (65% convective / 35% radiant absorption) beam air side Evaporative cooling of exhaust air before heat recovery. 1 Shelly St - Sydney 13

Systems Setup – Frenger ‘Radiant’ Chilled Beam (B) Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... Systems Setup – Frenger ‘Radiant’ Chilled Beam (B) Passive chilled (65% convective / 35% radiant absorption) beam air side Evaporative cooling and sensible heat recovery on fresh air. 1 Shelly St - Sydney 14

Copyright © 2010 EDSL www.edsl.net State of the art building simulation software... Results of the various different air conditioning systems modelled for 1 Shelly St building, Sydney.   Heating (kWh) Cooling (kWh) Auxiliary (kWh) Total (kWh) VAV fancoil 84,504.39 541,862.09 252,238.47 878,604.95 Active beam 84,468.56 529,660.69 203,059.41 817,188.66 Passive Beam (95% Convective / 5% Radiant absorption) 87,021.97 509,811.69 206,553.40 803,387.06 Frenger “Radiant” Passive Beam (65% Convective / 35% Radiant absorption) 86,836.56 454,034.25 203,257.08 744,127.89 Traditional VAV 365,106.69 663,804.59 389,736.06 1,418,647.34 Modern VAV 86,167.17 609,406.33 276,391.29 971,964.79 From the above results the Frenger “Radiant” passive beam system consumes the least energy for the building modelled.   Heating (kWh) Cooling (kWh) Auxiliary (kWh) Total (kWh) Frenger “Radiant” Passive Beam (65% Convective / 35% Radiant absorption) 86,836.56 454,034.25 203,257.08 744,127.89 By applying evaporative cooling on the exhaust air further energy savings can be achieved, however when applied to the fresh air system additional energy would be consumed.   Heating (kWh) Cooling (kWh) Auxiliary (kWh) Total (kWh) Evaporative cooling on exhaust air 88,454.71 411,994.34 209,178.74 709,178.93 Evaporative cooling on fresh air 88,319.67 383,777.83 282,394.64 754,491.95 1 Shelly St - Sydney 15