Fluid Sampling Made Simple OilScan

Slides:



Advertisements
Similar presentations
ODOT BULK FUEL MAINTENANCE PLAN WHAT TO EXPECT THE DAY THE VENDOR TAKES A SAMPLE.
Advertisements

CHAPTER 45 Engine Lubrication.
ENGINES, TRANSMISSIONS, FINAL DRIVES, TRAVEL/SWING MOTORS & HYDRAULICS: IMPROVE LIFE BY 2X TO 3X STRATEGIES TO INCREASE LIFE OF COMPONENTS AND EQUIPMENT.
Customer Service – International Dept. The thermal solar systems  Installation  Commissioning  Maintenance.
General System Maintenance BUS 4 COMPONENT FLOW.PPT
Metering Pump Spare Parts Replacement. Pump Components (Metering Pump) Pumps are supplied with a 120VAC or 240VAC power cord. Use care to ensure pump.
Oil Analysis Implementation Strategy J. Mike Weiksner BSME - Auburn University Years in Industry (EMO) Hold Certifications in Vibration & Oil.
© Blue Graphics Concept Sauer-Danfoss START-UP PROCEDURE PROPEL PUMP Instruction Sauer-Danfoss Belgium – T. Van Mossevelde.
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
1 Oil Fuel Line De-aerators What they are, what they do and how to install.
Expect More. World’s leader in pressure technology NA Sales Training Rev B – 10/10/13.
1B-1 Fire Engine Maintenance Unit 1B – Pump Inspections and Maintenance.
Diesel Generator Reliability: Lessons Learned from Storms
LAB SAFETY ORIENTATION
DHHB, 1ID MAINTENANCE Effects of Cold on Military Vehicles.
Unit 205: Cold water systems
ENGINE CLEAN OIL TOOL OIL RX • 999 TRAINING
Muhajir Ab. Rahim School of Mechatronic Engineering
Water Supply.
Monitoring Well Sampling. SAP (Sampling Analysis Plan) SAP (Sampling Analysis Plan) Frequency Frequency Purging Purging Pumps and Bailers Pumps and Bailers.
LubeWatch® Oil Analysis Program Review
CHAPTER 4 CPB 20004: Plant Utility n Maintenance
Unit 6 Engine Oil Life Extension. Baseline: “Prescribed” Oil Change Need-it-or-not changes based on: Mileage Calendar Operating Time.
Operating and maintenance of generator. Operating Generator If it is manually operated generator, whenever power goes off, before starting the generator,
Collection and Preservation of Water and Wastewater Samples
15 Water Supply. 2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe.
VpCI™ Packaging Solutions VpCI Metalworking Products World Sales Meeting 2009.
1 SHELL FLEET TECHNOLOGY TOUR August 29, VALUE DELIVERY THROUGH SERVICES OIL CONDITIONING MONITORING PROGRAM.
What tests are necessary to make sure your kegs are being cleaned, sanitized and filled correctly By Andrew J. Brewer
Cold Climate Operation: Diesel Engines 12/14. General Cold Climate Preparation  For cab climate control, prolonged idling may be necessary. Idle the.
Phase Separation and the Consequences of Water Infiltration Greggory Addam Vanover Safety Compliance Manager.
Floods in the Lab “In nature, floods are acts of God, but in the chemical laboratory, floods are preventable accidents that still happen.” – Bruce D. Pollard.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
Presentation Outline Cook Inletkeeper Mission & Programs Water Quality Basics Water Testing Options Sampling Schedule and Instructions Questions? Wrap.
1. Swab throat. 5. Read Results Positive = 2 lines. Strep A Rapid Test Strip Procedure For details, consult Lab Manual located at: P:\Clinical\Lab Manual.
MAINTENANCE INTERVAL SCHEDULE D6R TRACK TYPE TRACTOR 7AR EVERY 10 SERVICE HOURS OR DAILY.
Energy In Buildings By Mina Greas  Lighting and Daylighting  Water Heating Systems.
ACTIVE SOLAR DESIGN ALTERNATIVE ENEGRY SOURCES.
Sampling Oil-Filled Transformers
Lubricating system Components
S·O·S Fluid Analysis. S·O·S Fluid Analysis No Longer “Scheduled Oil Sampling” Caterpillar Dealer Labs now perform Coolant and Fuel analysis in addition.
Engine Lubrication Systems
Edward S. Kubinsky Jr. CROMPCO, LLC
AUTOMOTIVE COOLING SYSTEMS
Phase Separation and the Consequences of Water Infiltration
14 Refrigerant Recovery, Recycling, and Recharging.
Lecture (9): Monitoring & sampling methods, maintenance ,
JTSS / THE WAYS.
Dealing with Gasoline and ULSD Cross Drops
INDUSTRIAL HYDRAULICS
Engine Lubrication Systems
Fault detection Lecture (1).
Presented by:- ARAVIND P V MS S5 NO:-60
What are the Essential Fluids to Keep your Car Running Smoothly
Drawing Blood And Collecting Diagnostic Samples. 1. Performing Blood Draws / Heel sticks 2. Labeling Specimens 3. Blood Bank Collections 4. Performing.
BOP FLUID MAINTENANCE SIMON McMANUS WM CANNING LTD.
LubMat| Cooling System Predictive Maintenance| 2018
Auto Upkeep Basic Car Care, Maintenance, and Repair (2nd Edition)
Lubricating system Components
CHAPTER 45 Engine Lubrication.
Fluid Analysis Program Offerings
Maintenance Lubrication
TRENTON Casing Filler Presentation
NEW COMPLIANCE REGULATIONS
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Chapter 13 Lubrication.
Light Vehicle Diesel Engines
Lubrication Systems Chapter 12 Page 149.
Effects of Cold on Military Vehicles
Presentation transcript:

Fluid Sampling Made Simple OilScan

What is Oil Analysis? Oil analysis provides a detailed view of what is happening within machine components during operation Identifies Wear, Contaminant & Additive Elements: Detects 21 elements that can represent wear metals ] wear corrosion, dirt contamination and oil and coolant additives in the lubricant Monitors Lubricant Physical Properties: Viscosity Total Acid Number Water Content Soot Fuel Dilution

Step 1: Sample Collection 5 methods, 1 standard. Fill Port Dip Stick Port Sampling Port Return Line Tap Drain Port

Step 1: Sample Collection Fill Cap – Utilizes Vacuum Sample Device (Bellow,® or Sample Pump) Sample drawn through fill cap Vacuum container pulls sample into bottle Tube length should be cut to meet center level of the sump Simple, Clean, Easy, and Reliable

Step 1: Sample Collection Dip-Stick / Drop Tube - Utilizes Vacuum Sample Device (Bellow,® or Sample Pump) Most popular sampling method for static tanks and crankcases Universal lube access through fill-ports and/or dipstick channels No special hardware installation Insert tube to center level of sump Avoid jamming tube against bottom of sump

Step 1: Sample Collection Dip-Stick / Drop Tube - Utilizes Vacuum Sample Device (Bellow,® or Sample Pump) Most popular sampling method for static tanks and crankcases Universal lube access through fill-ports and/or dipstick channels No special hardware installation Insert tube to center level of sump Avoid jamming tube against bottom of sump

Step 1: Sample Collection Drain Port – No special sampling apparatus required Least accurate and reliable method Remove drain plug from bottom of tank and allow sufficient flow to remove any bottom sediment and water Perform visual assessment of sample to ensure no visible debris is present, resample if necessary

Step 1: Sample Collection Sample Port (Sump) - Utilizes fixed sample port such as Mini-mess or Push-Button Permanent sampling fixture or port Collection source provides consistent accuracy Provides exceptional assessment of machine status Applicable on pressurized and unpressurized systems

Step 1: Sample Collection Sample Port (In-Line) - Utilizes fixed sample port such as Mini-mess or Push-Button Sample drawn from common return line Collection point provides superior accuracy Should be located up- stream of the filter Best method for assessment of a machines contamination

Step 2: Ensure a Quality Collection Sample Precautions Draw all lube samples from optimal areas of the tank or return line Collect while lubricant is circulating or collect within 30-minutes of shutdown Consistency is key, take samples the same way each time

Step 2: Ensure a Quality Collection Don’t Wait for the Lab… Perform visual assessment on-site Look for irregularities in your sample: Water Visible Metal or Debris Abnormal Discoloration Cloudiness Take any necessary corrective actions ***Note any abnormal condition(s) on your sample form***

Step 3: Provide Detailed Sample Information Help the Lab Help You Complete all required documentation (Sample Form / Label) Report if sample was drawn cold Describe atypical conditions Include consistent equipment ID numbers Supply test point locations

Step 4: Equipment Precautions Inspect lube levels before sampling Monitor lube levels while sampling Ensure all caps are put back on and sample ports closed after sampling is completed

Step 5: Review Results Review sample reports immediately and implement corrections and recommendations without delay Sample reports are available electronically through Analysts’ cloud-based Lube Oil Analysis Management System (LOAMS®) Login at: www.analystsLOAMS.com

For additional information on how to take samples visit our website at www.analystsinc.com or contact our Customer Care Center at 800-655-4473

OilScan, CoolScan, FuelScan, PowerGardTM and Inspection Plus Offerings Program Tests Part numbers OilScan · Spectrochemical · Fuel dilution · Soot   ·Viscosity · Water · Glycol IPSKIT1 IPSKIT1B IPSKIT2 DS0552 CoolScan ·Corrosion Metals & Inhibitors ·Visual Assessment ·pH ·Glycol % ·Nitrite ·Freeze Pt. ·Specific Conductance ·Total Hardness ·Carboxylic Acid  DS0251 Fuelcan ·Density · Distillation · Cetane index · Sulfur · Water and sediment ·Cloud point · Flash point · Viscosity · Micro-organism/bacteria count TY26054 Inspection Plus Contains Oilscan and Coolant Kits. Available in 3-pack & 4-pack TY26859 TY26860 PowerGard / CPO Single kit per machine warranty DKGA2019

17