FRIGI-TECH REFLECTIVE ROOF COATINGS. MAIN BENIFITS INSULATES – Outperforms 7 of fiberglass insulation. Keeps interiors cooler and more comfortable. CUTS.

Slides:



Advertisements
Similar presentations
Wetsuit Roofing and Waterproofing
Advertisements

AES Specialties Contractors Ceramic Cover Systems 100 Photo Album.
Contents: Cover
Wilko Paint, Inc. Wilko Paint is the premier supplier of industrial finishes and coatings.   Our staff of industrial coatings specialists will provide.
Microteja Plus ® A State of the Art Heat-Dissipating Coating.
Unit 55 Roof Finish Roof Overhangs and Cornices • Open Cornices • Closed Cornices • Cornice Soffit Systems • Covering Roofs • Asphalt Shingles • Wood Shingles.
Ceramic Tile Installation Step 5 – Install Tile TNC EDUCATION SERVICES, INC Instructional Design and Learning Management.
A Technical Review of Proper Masonry Detailing
Moisture Control. Indications of Excessive Moisture Condensation,frost or ice on the inside surface of windows Damp spots on ceilings or inner surfaces.
A passive investment towards improved control over energy costs.
RESINOUS FLOOR COATINGS
MarineMend Repair Kit Procedure
K&W Permanent Metallic ® Block Seal
The Miracle Coating! Polycoat 750D What is it?.
Above Ground Storage Tanks &
Permanent Head Gasket & Block Repair w/Nanotechnology, 32 Fl Oz
 Ecocoat® Coatings with Nano technology  Features and Benefits  Superior water repellency  Excellent breathability (Permeability)  Hygrothermal Performance.
® SPACE TECHNOLOGY THAT STAYS ON TOP SPM THERMO-SHIELD ® INC BY.
Polarhide Roof Coating,Roof Retrofits And Solar Energy.
SYNTHETIC RED OXIDE METAL PRIMER It has good anti-corrosive properties. It contains Zinc-chrome. Recommended for agricultural, steel structures & other.
AutoAid Technologies Sdn. Bhd. Presents. Product Presentation.
1470 NW 107 th Ave Suite E, Miami, FL Phone:
Roofing Barrier System AC100 RF Best Coat  SCS Coatings, LLC 8 Timberbrooke Drive, Hopewell, NJ
Example of a successful lining Description: Tuff Stuff is sprayed as a protective lining onto a boat hull. The lining with TS provides a high level of.
Corrosion Control. ™ Drylar™ * Daclar™ * Vezlar™ * Zavlar™ * Voxlar™ * Nular ™
International Building Solutions Pty.Ltd Is proud to present.
Liquid Rubber is the world’s only EPDM rubber in liquid form. Liquid Rubber provides a seamless, single coat roof coating that can be applied up to 6.
Manufactured by Marketed by. ALL SEASON PROTECTION FOR ROOFS PROVEN SOLAR INSULATOR & LEAK PROOF COMPOUND ENJOY COOL SUMMERS & LEAK FREE MONSOONS.
ROOF MATE Step-By-Step Application Over BOARD-STOCK INSULATION
ROOF MATE Step-By-Step Application Over MODIFIED BITUMEN ROOFING Master Guide Specifications List of materials: ROOF MATE WHITE ROOF MATE BASECOAT ROOF.
A member of Sayegh Group
Objectives : ANALYZE home maintenance techniques.
AUZIE QUIC SLIP PTY LTD AQS METAL PRO – 001 INTERIOR AND EXTERIOR.
ROOF MATE Step-By-Step Application Over METAL ROOFING Master Guide Specifications List of Materials: ROOF MATE WHITE ROOF MATE BASECOAT ROOF MATE BUTTER.
Unit 26. Sizes 7-5/8” high 15-5/8” long Common depths – 8”, 10”,12” 3/8” mortar joints Walls usually stand 7’-4”
Presented by: Peter Emmons,
ROOF MATE Step-By-Step Application Over EPDM ROOFING Master Guide Specifications List of Materials: ROOF MATE WHITE ROOF MATE LIGHT GRAY ROOF MATE BUTTER.
Master Guide Specifications List of materials: ROOF MATE WHITE ROOF MATE BASECOAT ROOF MATE BUTTER GRADE ROOF MATE MESH Optional materials: UCC (United.
Part 2: Buildings as a System Lee F. Ball Jr., PhD
Protactinium 台 灣 拓 鏷 化 工 PD-660.  Oriental Star insulation paints are compounded of polymeric resins and inorganic insulating powders, which features.
ROOF MATE Step-By-Step Application Over CONCRETE ROOFING
Windows and Doors. Typically once the roofing material has been installed/completed the windows and doors are installed. It’s important to install these.
PAINT BASICS for APPLICATORS Dan P. Buelk PCS Presented by:
TEAM: FIBREX Waterproofing Coating. Introduction  The ASTM Standard defines it is a treatment of a surface to prevent the passage of water under hydrostatic.
Aqua-Therm Superior roof waterproofing system. Aqua-Therm Aqua-Therm is a uniquely formulated two pack coating system, the first of it's kind in the world,
Hard Floor Care VCT floor finish application This presentation is available for review at:
9.02 Exterior Maintenance and Cleaning. Roof, Gutters, Downspouts Check roof for leaves and twigs as they contribute excess moisture that can cause rot.
Getting Moldy Smell Out of Clothes Just A Few Tips
Welcome To Astec Paint. Our Product Energy Star Heat Reflective Coatings Exterior Finishes Interior Finishes Texture Coatings & Acrylic Renders Roof Restoration.
NATURAL TOUCH 2014 PROJECT Industrial II. Ceramic –Anticorrosive Coating BBN NATURAL TOUCH.
1 DISTEK N.A LLC Introduces: A revolutionary, new environment-friendly space age rust converting paint system Moshe Moked, P.Eng. ERX TM.
Cold Fluid Applied Reinforced Roofing. Agilast Cool Roof Systems Highly durable Water based Waterproof Reinforced with tough polyester fabrics/chopped.
Exterior Maintenance and Cleaning
Welcome To Astec Paints Paint With Pride
Garland’s White-Knight® Plus/ White-Stallion® Plus System
Elastomeric Wall Coating: Garland’s Tuff-Coat™ Systems
Garland’s Rust-Go System
Energizer® BK System.
MonostoneTM MonostoneTM is a specially formulated combination of polymers, modifiers and aggregates designed to enhance aesthetics of architectural features.
White-Star.
Innovative roof cool roofs by T.Maniammai & T.M.Supraja
Pyramic® & Solex® Systems
Corrosion Control.
Objectives : ANALYZE home maintenance techniques
CPR™ System.
Revitalizer™ Systems.
“Thermo reflective Nano technological treatment "
Interior Finishes and Detailing
Exterior Maintenance and Cleaning
Who is Weatherskin? WEATHERSKIN is a North American company who is focused on developing the highest caliber, eco-friendly coatings for use in the construction.
Presentation transcript:

FRIGI-TECH REFLECTIVE ROOF COATINGS

MAIN BENIFITS INSULATES – Outperforms 7 of fiberglass insulation. Keeps interiors cooler and more comfortable. CUTS COST of air conditioning by up to 40%. Increase in storage capacity of fuel storage tanks. INSULATES – Outperforms 7 of fiberglass insulation. Keeps interiors cooler and more comfortable. CUTS COST of air conditioning by up to 40%. Increase in storage capacity of fuel storage tanks. INHIBITS RUST – Prevents perforation and damage due to corrosion. INHIBITS RUST – Prevents perforation and damage due to corrosion. PROTECTS - against UV, chemical damage. Is not affected by high winds or rain. Resists Mildew and algae. PROTECTS - against UV, chemical damage. Is not affected by high winds or rain. Resists Mildew and algae. REDUCES THERMAL SHOCK - by lowering roof temperatures by as much as 60 degrees. This translates to less expansion/contraction and less stress and wear on fasteners and connections. REDUCES THERMAL SHOCK - by lowering roof temperatures by as much as 60 degrees. This translates to less expansion/contraction and less stress and wear on fasteners and connections. WATERPROOF – Stops leaks and prevents moisture absorption on all surfaces. WATERPROOF – Stops leaks and prevents moisture absorption on all surfaces. FIRE RETARDANT – Zero flame spread. FIRE RETARDANT – Zero flame spread. IMPROVES APPEARANCE - with an extremely durable elastomeric finish that will not crack, chip, or peel. Can be tinted any color. Cuts your maintenance cost. IMPROVES APPEARANCE - with an extremely durable elastomeric finish that will not crack, chip, or peel. Can be tinted any color. Cuts your maintenance cost. ENVIRONMENTALLY SAFE – No asbestos, lead, vinyl acetate, plastics, oils, odors or gases. Wash with water. ENVIRONMENTALLY SAFE – No asbestos, lead, vinyl acetate, plastics, oils, odors or gases. Wash with water. ENCAPSULATES - asbestos surfaces and existing hazardous coatings. ENCAPSULATES - asbestos surfaces and existing hazardous coatings.

APPLICATIONS Any surface that heat needs to stay in or out of. Metal Metal Concrete Concrete Asphalt Asphalt Rubber Rubber Glass Tar and Gravel Wood Shingle

ENERGY STAR APPROVAL ENERGY STAR is a U.S. government- backed program helping businesses and individuals protect the environment through superior energy efficiency. ENERGY STAR is a U.S. government- backed program helping businesses and individuals protect the environment through superior energy efficiency.

PRODUCTS FRIGI-TECH TOP COAT FRIGI-TECH TOP COAT FRIGI-TECH TOP COAT II FRIGI-TECH TOP COAT II FRIGI-TECH PRIMER FRIGI-TECH PRIMER POLYESTER MEMBRANE POLYESTER MEMBRANE

TOP COAT An Acrylic white coating with nearly 400% elongation. Ideal for metal, built-up roofs with good drainage, shingles and all types of walls. Produces a tough washable coat that reduces dirt pick-up and stays cool with ceramic ingredient. An Acrylic white coating with nearly 400% elongation. Ideal for metal, built-up roofs with good drainage, shingles and all types of walls. Produces a tough washable coat that reduces dirt pick-up and stays cool with ceramic ingredient.

TOP COAT II All of the qualities of TOP COAT original with the added ability to resist standing water conditions. To be used on all surfaces in area that experience high humidity. Can reduce heat gain as efficiently as 7 inches of conventional insulation All of the qualities of TOP COAT original with the added ability to resist standing water conditions. To be used on all surfaces in area that experience high humidity. Can reduce heat gain as efficiently as 7 inches of conventional insulation

PRIMER 100% acrylic, Elastomeric roof mastic formulated to exhibit hi- adhesion and flexibility. For use over most types of roof and wall surfaces. Recommended for use on all foam roofs. 100% acrylic, Elastomeric roof mastic formulated to exhibit hi- adhesion and flexibility. For use over most types of roof and wall surfaces. Recommended for use on all foam roofs.

POLYESTER MEMBRANE A spun bound and woven 100% polyester fabric, which is embedded into the basecoat to prevent extreme movement by greatly increasing the tensile strength of the system. A spun bound and woven 100% polyester fabric, which is embedded into the basecoat to prevent extreme movement by greatly increasing the tensile strength of the system.

PROPERTIESPRIMER TC I TC II ASPHALT Viscosity Total Solids 50%50%55%53% Permeance Tensile P.S.I Elongation600%380%400%2000% Flex 0 F PassPassPassPass

% Solar Reflective ModifiedBitumenBlack6.8ModifiedBitumenTOPCOAT88.4ConcretePainted24.0Concrete Painted w/ TOPCOAT87.1GalvanizedMetal29.4GalvanizedMetalTOPCOAT88.0

METAL ROOF APPLICATION VISUAL INSPECTION and REPLACEMENT of DAMAGED BUILDING MATERIALS The substrate to be coated must be in SOUND condition. Physically inspect the surface area for missing or damaged building materials. Replace and/or repair all damaged areas back to sound and solid condition. Check for loose or missing fasteners (screws) and tighten or replace them. Inspect for any existing leaks and be sure to repair leaks prior to the application of coating. Make sure roof is adequately vented. Check with a roofing contractor if necessary. VISUAL INSPECTION and REPLACEMENT of DAMAGED BUILDING MATERIALS The substrate to be coated must be in SOUND condition. Physically inspect the surface area for missing or damaged building materials. Replace and/or repair all damaged areas back to sound and solid condition. Check for loose or missing fasteners (screws) and tighten or replace them. Inspect for any existing leaks and be sure to repair leaks prior to the application of coating. Make sure roof is adequately vented. Check with a roofing contractor if necessary.

METAL ROOF APPLICATION STEP#:2 PRESSURE CLEANING High Pressure Blast entire roof surface with at least 1500 P.S.I. of pressure using a water and chlorine solution (1 quart chlorine to 5 gallons of water). Thoroughly remove all dirt, oil, grease, residues, mold, mildew, algae and any other surface contaminants. When roof is completely cleaned, rinse with water only. Let roof surface dry before continuing. STEP#:2 PRESSURE CLEANING High Pressure Blast entire roof surface with at least 1500 P.S.I. of pressure using a water and chlorine solution (1 quart chlorine to 5 gallons of water). Thoroughly remove all dirt, oil, grease, residues, mold, mildew, algae and any other surface contaminants. When roof is completely cleaned, rinse with water only. Let roof surface dry before continuing.

METAL ROOF APPLICATION First Spot Prime all rusted areas and let dry at least 12 hours before applying the second coat of rust inhibitor to the effected area. Apply the rust inhibitor at a rate of square feet per gallon covering the entire rusted surface. Wet film thickness of mils wet resulting in dry film thickness of 7-9 mils. Let the rust inhibitor dry at least 12 hours before continuing First Spot Prime all rusted areas and let dry at least 12 hours before applying the second coat of rust inhibitor to the effected area. Apply the rust inhibitor at a rate of square feet per gallon covering the entire rusted surface. Wet film thickness of mils wet resulting in dry film thickness of 7-9 mils. Let the rust inhibitor dry at least 12 hours before continuing

METAL ROOF APPLICATION STEP#:4 CAULKING SCREWS Patch and Caulk all screws or fastener heads, cracks, crevices, fractures, holes, valleys, vents, voids, etc., with a Water Proofing caulk. Use a trowel or stiff brush to apply. Multiple coats are better than one thick coat if possible. STEP#:4 CAULKING SCREWS Patch and Caulk all screws or fastener heads, cracks, crevices, fractures, holes, valleys, vents, voids, etc., with a Water Proofing caulk. Use a trowel or stiff brush to apply. Multiple coats are better than one thick coat if possible.

METAL ROOF APPLICATION STEP#: 5 TAPING SEAMS Tape all visible seams, large cracks and fractures prone to water intrusion on roof surface. Apply a liberal coat of PRIMER at mils wet film thickness, directly to the affected area using brush, roller or airless spray and lay the POLYESTER MEMBRANE directly into the WET PRIMER. STEP#: 5 TAPING SEAMS Tape all visible seams, large cracks and fractures prone to water intrusion on roof surface. Apply a liberal coat of PRIMER at mils wet film thickness, directly to the affected area using brush, roller or airless spray and lay the POLYESTER MEMBRANE directly into the WET PRIMER.

METAL ROOF APPLICATION STEP#:6 PRIME COAT Apply PRIMER using 1- brush, 2- at least a one inch nap roller, or 3- at least a 1 gallon per minute, 3,000 P.S.I. piston type airless sprayer with a minimum tip size of.027 tip. STEP#:6 PRIME COAT Apply PRIMER using 1- brush, 2- at least a one inch nap roller, or 3- at least a 1 gallon per minute, 3,000 P.S.I. piston type airless sprayer with a minimum tip size of.027 tip.

METAL ROOF APPLICATION Apply the PRIMER at a rate of square feet per gallon covering the entire roof surface. Wet film thickness of mils wet resulting in dry film thickness of 7-9 mils. Let PRIMER dry at least 12 hours before continuing. Apply the PRIMER at a rate of square feet per gallon covering the entire roof surface. Wet film thickness of mils wet resulting in dry film thickness of 7-9 mils. Let PRIMER dry at least 12 hours before continuing.

METAL ROOF APPLICATION STEP#: 7 FIRST COAT of FINISH/TOP COAT When Spraying or Rolling TOP COAT the first coat of TOP COAT must be applied perpendicular to the coat of PRIMER to achieve a checkerboard pattern. Apply the first coat of TOP COAT at a rate of square feet per gallon per coat over the entire roof surface. Wet film thickness of mils resulting in dry film thickness of 8-10 mils. STEP#: 7 FIRST COAT of FINISH/TOP COAT When Spraying or Rolling TOP COAT the first coat of TOP COAT must be applied perpendicular to the coat of PRIMER to achieve a checkerboard pattern. Apply the first coat of TOP COAT at a rate of square feet per gallon per coat over the entire roof surface. Wet film thickness of mils resulting in dry film thickness of 8-10 mils.

METAL ROOF APPLICATION STEP#: 8 SECOND COAT of FINISH/TOP COAT Apply the second coat of TOP COAT at a rate of square feet per gallon per coat over the entire roof surface. Wet film thickness of mils resulting in dry film thickness of 8-10 mils. Let dry at least 24 hours before your Final Evaluation STEP#: 8 SECOND COAT of FINISH/TOP COAT Apply the second coat of TOP COAT at a rate of square feet per gallon per coat over the entire roof surface. Wet film thickness of mils resulting in dry film thickness of 8-10 mils. Let dry at least 24 hours before your Final Evaluation

METAL ROOF APPLICATION STEP#: 9 FINAL EVALUATION A detailed evaluation of the completed job will determine the quality of the workmanship and whether strict application specifications have been met. Be sure to check that all roof areas are completely coated and sealed under permanently placed roof items such as roof top air conditioning units. Divide roof into 1,000 square feet sections and randomly check one spot in each section for a dry film thickness of at least 20 mils. If specifications have not been met, determine how much material will be required to meet specifications and recoat. STEP#: 9 FINAL EVALUATION A detailed evaluation of the completed job will determine the quality of the workmanship and whether strict application specifications have been met. Be sure to check that all roof areas are completely coated and sealed under permanently placed roof items such as roof top air conditioning units. Divide roof into 1,000 square feet sections and randomly check one spot in each section for a dry film thickness of at least 20 mils. If specifications have not been met, determine how much material will be required to meet specifications and recoat.

EXAMPLES

EXAMPLES

BEFORE AND AFTER