Electromyography E.M.G..

Slides:



Advertisements
Similar presentations
Electromyography: Recording
Advertisements

BIOPOTENTIAL AMPLIFIERS
ECG Biopotential Amplifier ASHLEY MULCHRONE ZEXI LIU.
7th Lecture Dimitar Stefanov. Recapping Three types electrodes are used for sensing of EMG signals: 1.indwelling (intramuscular) electrodes (single fiber.
Analog Basics Workshop RFI/EMI Rejection
Differential Amplifier
Electromyography (EMG) Instrumentation
Biofeedback Jennifer L. Doherty-Restrepo Entry-level Athletic Training Education Program PET 4995: Therapeutic Modalities.
The Use of Surface Electromyography in Biomechanics by Carlo De Luca
Designing a EMC Compatible Electronic Meter using AD7755 a.
Data and Computer Communications
In the name of God Electromyography Electromyography (EMG) (EMG) By:sahar shahbazi.
Chapter 5 Signals and Noise  Signal carries information about the analyte that is of interest to us.  Noise is made up of extraneous information that.
ENTC 4350 BIOMEDICAL INSTRUMENTATION I BASIC DIFFERENTIAL AMPLIFIER.
Electromyography: Recording D. Gordon E. Robertson, Ph.D. Biomechanics Laboratory, School of Human Kinetics, University of Ottawa, Ottawa, CANADA.
Analogue Electronics II EMT 212/4
COMMUNICATION SYSTEM COMMUNICATION :
GG 313 Lecture 26 11/29/05 Sampling Theorem Transfer Functions.
EMG Analysis and Interpretation
Biopotential Amplifier Speaker: Sun Shih-Yu 3/20, 2006.
The Illinois Society of Electroneurodiagnostic Technologists (ISET) Fall Meeting: Electronics Crash Course for Technologists Saturday, November 9, 2013.
Vital Signs Monitor UConn BME 4900 Vital Signs Monitor Purpose As the population ages, many people are required by their doctors to take vital signs.
1 ELE5 COMMUNICATIONS SYSTEMS REVISION NOTES. 2 Generalised System.
ELECTRICA L ENGINEERING Principles and Applications SECOND EDITION ALLAN R. HAMBLEY ©2002 Prentice-Hall, Inc. Chapter 6 Frequency Response, Bode Plots,
University of Minnesota Duluth
1 Analog versus Digital Information-bearing signals can be either analog or digital. Analog signal takes on a continuous range of amplitude values. Whereas.
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Fourth Edition, by Allan R. Hambley, ©2008 Pearson Education, Inc. Lecture 17 Fourier Analysis, Low.
Signal Analyzers. Introduction In the first 14 chapters we discussed measurement techniques in the time domain, that is, measurement of parameters that.
Portable Real Time ECG Design
PROSTHETIC LEG PRESENTED BY:-AWAIS IJAZ HASNAT AHMED KHAN.
ELECTRICAL ENGINEERING: PRINCIPLES AND APPLICATIONS, Third Edition, by Allan R. Hambley, ©2005 Pearson Education, Inc. CHAPTER 6 Frequency Response, Bode.
1.1 What is Noise? any ‘unwanted” part of the analytical signal always some noise in a signal 1.2 Signal-to-noise ratio (S/N) for a set of data (replicate.
Electromyography E.M.G..
Operational Amplifiers Chapter 10 Boylestad Electronic Devices and Circuit Theory.
BME 311: BIOMEDICAL INSTRUMENTATION I Lecturer: Ali Işın
Ch7 Operational Amplifiers and Op Amp Circuits
Physiologic signals Lecture (2).
Technological evolution of BCI
Biomedical Instruments Design Biopotential Amplifiers
SIGNAL CONDITIONING Signal conditioning is stage of instrumentation system used for modifying the transduced signal into a usable format for the final.
Chapter 10: Operational Amplifiers
PUSAT PENGAJIAN KEJURUTERAAN KOMPUTER & PERHUBUNGAN
Three types electrodes are used for sensing of EMG signals:
(4) Filters.
Chapter 5: Signals and Noise
Experimental methods in nerve muscle physiology
Chapter 5. Signals and Noise
Analogue Electronics Circuit II EKT 214/4
Analogue Electronic 2 EMT 212
Medical electronics II
Operational Amplifiers
Physiologic signals Lecture 6.
Operational Amplifiers (Op Amps) in Chemical Instrumentation
TOPIC 3: FREQUENCY SELECTIVE CIRCUITS
FINAL YEAR PROJECT 1 WPB49804 Development of arm gesture device
Overview Communication is the transfer of information from one place to another. This should be done - as efficiently as possible - with as much fidelity/reliability.
Chapter 6 Feedback Circuits
Lesson 11: Transducer Electrical Interfaces
Electromyography E.M.G..
Instrumentation & Measurement (ME342)
Biofeedback Chapter 7.
Filters A filter removes a signal’s unwanted frequency components.
Amplifiers: A Bio amplifier is an electrophysiological device, a variation of the instrumentation amplifier, used to gather and increase the signal integrity.
Chapter 11 Amplifiers: Specifications and External Characteristics
Chapter 4 Transmission Impairments and Multiplexing
Biomedical Instruments Design Biopotential Amplifiers 1.
Medical electronics II
8.5 Modulation of Signals basic idea and goals
Uses of filters To remove unwanted components in a signal
Chapter 10 Analog Systems
Presentation transcript:

Electromyography E.M.G.

E.M.G. EMG is a continuosly changing voltage in the time domain EMG - Electromyography

E.M.G. Characteristics The amplitude of the EMG signal is stochastic (random) The amplitude can range from 0 to 6 mV (peak-to-peak) The energy of the signal is is in the 0 to 500 Hz frequency range, with the dominant energy being in the 50-150 Hz range. EMG - Electromyography

Frequency Analysis Fourier transformation quantifies the amount of each frequency in the signal Frequency domain EMG - Electromyography

Resultant signal produced by summing the 10 signals to the left 10 individual sinusoids each with different amplitudes and frequencies Frequency spectrum. Plot of amplitude of signal at each frequency

Detecting and Recording the EMG signal Two main issues of concern that influence the fidelity of the signal: Signal to noise ratio. the ratio of the energy in the EMG signal to the energy in the noise signal. Noise is defined as electrical signals that are not part of the wanted EMG signal. Distortion of the signal relative contribution of any frequency component in the EMG signal should not be altered. EMG - Electromyography

Electrode Stability When an electrode is placed on the skin a chemical reaction takes place which requires some time to stabilize, The chemical reaction should remain stable and should not change significantly if the electrical characteristics of the skin change from sweating or humidity changes. EMG - Electromyography

Electrical Noise All electronics equipment generates electrical noise. Inherent noise in the electronics components in the detection and recording equipment All electronics equipment generates electrical noise. EMG - Electromyography

Electrical Noise Ambient noise - originates from sources of electromagnetic radiation. The dominant concern for the ambient noise arises from the 60 Hz (or 50 Hz) radiation from power sources. The ambient noise signal amplitude may be 3 times the magnitude of the EMG signal. EMG - Electromyography

Electrical Noise Motion artifacts - two main sources of motion artifact: Interface between the detection surface of the electrode and the skin Movement of the cable connecting the electrode to the amplifier. Most of their energy in the frequency range from 0 to 20 Hz EMG - Electromyography

Electrical Noise Inherent instability of the signal The frequency components between 0 and 20 Hz are particularly unstable Because of the unstable nature of these components of the signal, it is advisable to consider them as unwanted noise and remove them from the signal. EMG - Electromyography

Electrode Placement Place 1 - 2cm apart –A distance of 1 – 2cm is adequate to obtain a representative sample of the EMG signal from a muscle. Midline placement – Electrodes should be placed away from the edges of muscles where crosstalk from signal of adjacent muscles is more likely to occur. Electrode orientation - The axis connecting the two electrodes should be parallel with longitudinal axis of the. Place away from musculotendonous junction – Near the musculotendonous junction there are less fibers and they are thinner, thus the amplitude of the EMG will be less. The signal also becomes more susceptible to crosstalk from adjacent muscles. Place away from the motor point – Action potentials travel distally and proximally along the muscle fibers from the motor point. Because the positive and negative phases of the action potentials (detected by the differential configuration) will add and subtract with minor phase differences there will be erroneous higher frequency components in the resulting EMG signal.

Surface Electrode Placement

FILTERING Analog filters are electronic circuits which are designed to transform an input to a desired output by eliminating signals of specified undesired frequency bands Kin 304 Spring 2005 EMG - Electromyography 11

FILTERING High Pass Low Pass V Band Pass Band Elimination Frequency When filters are used, some of the desired signal may be lost Preprocessing of signal is desirable and may minimize computing demands

Filtering EMG signal will be contaminated by some noise. The signal to noise ratio can be increased by filtering between 20 - 500 Hz. (Band Pass) EMG - Electromyography

Amplification Single-ended Amplification Skinfold caliper output from potentiometer Differential Amplification EMG - preamplifier EMG - Electromyography 13

Differential Amplification

Differential Amplification The output voltage (Vo) results from the difference between two inputs (V1 and V2). Then Vo = K(V2-V1). T This type of recording minimizes noise This assumes that the two signals are subtracted perfectly, which unfortunately they are not. How well your differential amplifier subtracts the two signals is quantified by the Common Mode Rejection Ratio (CMRR). Perfection would be a CMRR of infinity. EMG - Electromyography

Ground Electrode The ground or reference electrode provides the common reference for the differential amplifier. Placed on an electrically neutral tissue a long way from the detecting electrodes. Large electrode with electrically conductive gel to ensure a very good electrical contact with the skin. Reduces power line interference noise. EMG - Electromyography