Surgical protocol for NobelParallel™ CC

Slides:



Advertisements
Similar presentations
Temporary Abutment.
Advertisements

SURGICAL PROCEDURE GUIDE FOR BR SYSTEM USING THE UNIVERSAL KIT.
Composed by Dr. Gary F. Turnier Implant placement Dr.Gary F. Turnier.
Large Taper Files. Engine-driven files Hand-Using Large Taper Files.
Presenter Date Time: 20 minutes, 2 Cases Q&A : 10 minites.
Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.
Typical Walk-in Closet with elfa® décor
Bilateral Maxillary Sinus Lift Right side is planned as a staged sinus lift procedure with the surgical removal of the second bicuspid Right side is planned.
Impression procedure.
About Servo - dental. about Servo - dental.
1- Pipsqueak Engine Millwork on uprights and base.
Connecting crank and pivot shaft assemblies. Press fits, or interference fits are sometimes used in manufacturing to reduce manufacturing costs or liabilities.
In partnership with Nobel Biocare Diagnosis and treatment planning for the replacement of missing teeth Module 1 | Session 4 Treatment planning and restoring.
NobelActive Internal and External Hex Implants Nobel Marketing Claims this is the “Implant of the Future”
Tatum Bone Expansion Illustrations
Surgical extraction with Immediate Implant Placement These cases are selected only after careful review and preparation These cases are selected only after.
Immediate loading after extraction - implantation
PROSTHETIC PROCEDURE MANUAL BR SYSTEM. CEMENTED RESTORATION Impression Copings Set Screw Pick-up Transfer Implant Analog Cemented Abutment Angled Abutment.
Surgical Guides With GuideMia. About dental implant surgical guides Designed according to patient’s anatomy Accurately guide implant drilling and placement.
DROP IN ANCHOR DETAIL COMMERCIAL SERIES LIFTS INSTALLATION MANUAL Drop In Anchor/COMMERCIAL SERIES.
Immediate loading after extraction - implantation CASE #2 MR X G, 38 Central right replaced.
Straumann® Bone Level Implant Surgical Product Portfolio
Facility Implants Placement Techniques. Surgical Kit.
Dental Implants Chapter 11. Implant Materials Implant metals have been used in orthopedic medicine for many years. In dentistry, titanium is the metal.
MegaGen Implant System
SURGICAL PROCEDURE GUIDE FOR IR SYSTEM USING THE UNIVERSAL KIT.
Description Neck Rounded apical area Rounded apical area - Protects the soft tissue during insertion of the implant Thread.
APOLONIA APOLONIA Submerged Implant System C S M Feb 25, 2009.
Case series of wide diameter (6 mm) implants immediately loaded with posterior single restorations A Immediate loading of implants replacing single molars.
Straumann® Bone Level Implant Prosthetic Product Portfolio
Guide to Tatum Hand Tools HT.01 - HT.10. HT.01 Hand Mandrel (for use with HT.09 Implant Driver)
Straumann® Bone Level Implant
Tatum Tapered Implant Placement Instructions. When acceptable attached Gingiva is present, use an appropriate tissue punch at implant site.
Level 1 Diploma in Plumbing Studies © 2013 City and Guilds of London Institute. All rights reserved. 1 of 23 PowerPoint presentation Preparation techniques.
Module 12 RESTORE RESTORE ® External Hex Implant System Surgical Hands-On.
KISplant 2016 Dr. Meor Ahmad Isharra Ishak By
# 23 SINGLE IMPLANT CASE Osteotomy Progression in Open Guide Sleeve
Guide Right™ CASE FOR ANGLED IMPLANTS
Guide Right™ Immediate Placement & Immediate Load
Full Arch Restoration.
Guide Right™ Surgical Guide System
Maxillary Single Implant Case Angular & Linear Correction in 2 Planes
Serial Guide Technique
Immediate implant placement and function in the anterior region (cement-retained) – Hands-on presentation Disclaimer: Some products may not be regulatory.
Clinical solutions with NobelActive™ implant design
Study Club Name NobelReplace Straight Drill Protocol
Overview on complete guided surgical protocol for partially edentulous cases with NobelSpeedy® Groovy and Shorty.
Overview on complete guided surgical protocol for partially edentulous cases with NobelReplace® Tapered and Replace Select™ Tapered.
NobelProcera® restorations for edentulous cases
SmartFix™ for ANKYLOS® Your solution to the Edentulous Patient?
Overview on complete guided surgical protocol for partially edentulous cases with NobelReplace® Straight, Replace Select™ Straight and NobelSpeedy® Replace.
Locator® Abutment Workflow presentation
Restoring an All-on-4™ case with NobelGuideTM
Overview on complete guided surgical protocol for edentulous cases with Brånemark System® Groovy and Shorty.
Location, date Presenter name
NobelProcera™ Implant Bridge
NobelActive™ Clinical Cases
Snappy™ Abutment – clinical cases
NobelParallel™ CC.
Powered vs Manual Periotome?
ALMITECH Implant system Mike Shulman, DDS Alex Breytman Almitech Inc.
NCB® Plating System Display
W201 3R hardboard Replacement Procedure.
NCB® Distal Femoral Workshop
Treatment of Midshaft Clavicle Fractures: Application of Local Autograft With Concurrent Plate Fixation  Erik L. Slette, B.A., Jacob D. Mikula, B.S.,
Planning with the CrossFitTM PLAN Set
Treatment of Midshaft Clavicle Fractures: Application of Local Autograft With Concurrent Plate Fixation  Erik L. Slette, B.A., Jacob D. Mikula, B.S.,
Planning with the CrossFitTM PLAN Set
Customized Impression Post
Presentation transcript:

Surgical protocol for NobelParallel™ CC

Required implants and instruments The following implants and instruments are required for implant placement: Disposable drills for selected implant dimensions and bone density NobelParallel CC implant RP x 13mm Abutments

NobelParallel™ Surgical Kit Color-coded to match implant platform Universal color-coding enables inventory organization and stocking efficiency Colors match implant packaging Drill Protocol provided for reference Autoclavable* * See current cleaning and sterilization guidelines for details: www.nobelbiocare.com/sterilization

NobelParallel™ Surgical Kit – Drilling Protocol is provided on the drill kit Drills within [brackets] denote as optional

NobelParallel™ Surgical Kit – Drilling Protocol is provided on the drill kit Drills within [brackets] denote as optional

NobelParallel™ Surgical Kit – Drilling Protocol is provided on the drill kit Drills within [brackets] denote as optional

Drill sequence Optional Optional Reference line 13mm

Drill sequences for different bone types Soft Bone Type IV Medium Bone Type II & III 2.0mm 2.4/2.8mm [3.2/3.6mm] Reference line NobPrl CC RP 4.3mm Reference line 2.0mm 2.4/2.8mm 3.2/3.6mm *CD 4.3mm NobPrl CC RP 4.3mm [*ST 4.3mm] [optional] [optional] *CD = Cortical Drill *ST = Screw Tap

Drill sequences for different bone types Dense Bone Type I Reference line 2.0mm 2.4/2.8mm 3.2/3.6mm *CD 4.3mm NobPrl CC RP 4.3mm *ST 4.3mm *CD = Cortical Drill *ST = Screw Tap

Drill sequence for NobelParallel™ CC RP x 13mm (medium bone) Twist drill with tip Ø 2mm Direction indicator Maximum speed 2000 rpm

Drill sequence for NobelParallel™ CC RP x 13mm (medium bone) Twist step drill Ø 2.4/2.8mm Depth probe Maximum speed 2000 rpm

Drill sequence for NobelParallel™ CC RP x 13mm (medium bone) Optional Twist step drill Ø 3.2/3.6mm Cortical drill 4.3mm Screw tap 4.3mm Maximum speed 2000 rpm Maximum speed 2000 rpm Low speed 25 rpm

Unpack implant Open the outer package of the implant Empty the inner sterile container with the implant onto the sterile field Remove the plastic cylinder Notes: Each implant is packaged in a double sterile vial The outer package includes two printed peel-off labels with product data, which can be affixed to the patient chart The cap of the outer package is color-coded to identify the implant platform Cover screw is included with implant

Implant placement – using a drill unit Make sure that the Implant Driver is fully seated Low speed 25 rpm Maximum 45Ncm

Implant placement – using a manual torque wrench Make sure that the Implant Driver is fully seated Maximum 45Ncm

Implant placement – using a surgical driver Make sure that the Implant Driver is fully seated

Final implant placement For maximum esthetic results place the implant on the level of the buccal bone or 0.5 – 1 mm below. When placing the implant, align one of the black hex indicators on the implant driver parallel to the buccal wall, which ensures that one of the flat sides of the hexagon is parallel to the buccal side, ensuring preferred prosthetic abutment orientation.

Finalization options There are three options for finalizing the implant surgery One-stage immediate function Provisionalize implant for immediate esthetics and function, using Nobel Biocare temporary or final abutments. One-stage delayed function Use Screwdriver Unigrip to connect a healing abutment to implant. If applicable, suture back the soft tissue. Two-stage delayed function Use Screwdriver Unigrip to connect a cover screw to the implant. Suture tissue flap using desired technique.

BACK-UP

Drill sequence for NobelParallel™ CC RP x 13mm „Cheat sheet“ for hands-on exercise (medium bone) Optional Precision drill 2000 rpm Screw tap RP Ø 4.3mm 25 rpm Depth probe 2000 rpm Twist step drill Ø 3.2/3.6mm 2000 rpm Drill Ø 2mm 2000 rpm Twist step drill Ø 2.4/2.8mm 2000 rpm Cortical drill Ø 4.3mm Reference line