EFCOG Electrical Improvement Project Electrical Hazards Awareness Briefing Awareness Working Near Overhead Electrical Lines Module 4.

Slides:



Advertisements
Similar presentations
Subcontractor Electrical Safety & NFPA 70E
Advertisements

Electrical Hazards for Fire and Rescue Departments Part III: Fires Near High Tension Power Lines Captain I Gary C. Dize Health and Safety Division Fairfax.
Captain I Gary C. Dize Health and Safety Division
Working Around/Under Loads
Electrical Safety 1926 Subpart K ‑ Electrical
EFCOG Electrical Improvement Project Electrical Hazards Awareness Briefing Excavation and Trenching Module 5.
Summary 1) Introduction 2) General comments 3) Definition
This initiative has been developed to make miners aware of the hazards associated with operating and working around shuttle cars and scoops. Please remember,
Module 1: Safety. Objectives Outline safety rules that apply to conditions at homes, labs and workshops, and jobs. Identify electrical hazards and learn.
Electrical Hazards Awareness Briefing Awareness Working Near Overhead Electrical Lines Peter Watton March 2013.
Electrocution Hazards in Agriculture October, 2010.
Electrical Safety Scenarios
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Scissor Lift Safety Training
Preventing Deaths and Injuries to Public Workers While Working Around Mobile Equipment.
Powered Industrial Trucks - Operator Training
Stairways and Ladders 1926 Subpart X - Stairways and Ladders
Ladder Safety and Aerial Lifts
FALL PROTECTION. What, me worry? According to the US DOL, falls are the leading cause of worker fatalities in the construction industry. On average, between.
EQUIPMENT SPOTTER TRAINING
Safety for Workers on Foot. Safe Practices  Consider worker behavior when developing the ITCP. Determine locations where workers are likely to go.
LADDER SAFETY.
Crane Safety, Subpart N
Crane and Hoist Training
Electrocution 44% Rigging Failure 15% Load Handling 14% Operator Error 7% Overload 7% Dismantling Boom 5% Wire Rope Failure 3% Miscellaneous 3% Struck.
Module 4: Overhead and Underground Power Lines. Overview of Module 4 Background on power lines Hazards of overhead and underground power lines Injury.
Safety Training Presentations
Elkhorn Construction Inc.
Moving Equipment Safely around Power Lines Presented by: Farmington Electric Utility FCSN-Equipment Move Task Force.
Purpose Power lines Equipment Assured Grounding GFCI Conclusion.
BUILDING TRADE SAFETY ELECTRICAL SAFETY.
Slide 1 (of 15) Aerial Lift Safety in Construction Michael McCann, PhD, CIH Director of Safety and Ergonomics The Center to Protect Workers’ Rights
Scissor Lift Safety Training Working Safely on Scissor Lifts 29 CFR OSHA Scaffolding Safety Requirements.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety.
Copyright  Progressive Business Publications Electrical Safety.
2.5.5 Student Book © 2004 Propane Education & Research CouncilPage Coordinating Loading and Unloading of ASME Tanks Using Contractor- Operated.
1a.  Exposed part  Live or energized part  De-energized part 1a.
Electricity.
Electrical Safety. Definitions v Exposed part v Live or energized part v De-energized part 1a.
1 Falls Module 2. 2Objectives After this module you should be able to – identify the most common fall hazards – take the steps necessary to avoid those.
Safety for Workers on Foot Module 3. Safe Practices.
Pennsylvania Bureau of Deep Mine Safety Lockout/Tagout Program.
Electrical Hazards Temporary Wiring and Lighting Systems.
Struck-By Hazards. Crane Tip Over and Failure Incidents Soft Ground Inadequate outrigger support Overload Crane out of level Boom strike.
Traffic Rules Clarity February 2013 Mine Operations.
MNM Fatal Electrical Electrical October 16, 2004 (Missouri) October 16, 2004 (Missouri) Crushed Stone Operation Crushed Stone Operation Laborer.
Electrical Work Practices City of Council Bluffs Presented by: SilverStone Group © 2012 Zywave, Inc. All rights reserved.
KEY LEARNING from an Electrical Discharge [Dangerous Occurrence] that occurred on Thurs 03 October 2013.
Working Safely Near Power Lines NOVA SCOTIA ASPHALT USER PRODUCER ASSOCIATION.
Mosaic Mineral’s Mobile Equipment High Voltage Overhead Line Procedure (the Foot Rule) This lesson is intended for Minerals (Mine) site employees.
Overhead and Underground Power Line Safety 1 Quentin Baker Director of Safety
Crane, Conveyor, and Rigging Part I - Crane OSHE 112, Spring 2016
Session 3: Struck-By, Caught-In or Between, and Energy Release Hazards
Electrical Safety Lesson 7.
For more Information you may visit these helpful websites:
Lifting & Rigging Continuing Education Fourth Quarter 2016
Personal Protective Equipment
Click anywhere to get started…
Electrical Safety.
Safety is part of our culture at Halliburton
Click anywhere to get started…
Click anywhere to get started…
Click to start.
Electrical Safety Lesson 7.
Click anywhere to get started…
Click anywhere to get started…
Cranes and Hoists Standard 29 CFR Part
Blind Spots & Danger Zones
Presentation transcript:

EFCOG Electrical Improvement Project Electrical Hazards Awareness Briefing Awareness Working Near Overhead Electrical Lines Module 4

EFCOG Electrical Improvement Project Overhead Electrical Power Lines- The Silent Killer The leading cause of fatal electrical incidents while on the job is contact with power lines Power lines kill an average of 133 workers per year Half of these workers are between ages of 25 and 35 Leading causes –Contact with heavy equipment (cranes, drilling rigs, backhoes, dump trucks, etc.) –Contact with long handled tools and hand carried items (ladders, scaffolds, metal siding, metal poles, etc.)

EFCOG Electrical Improvement Project A 29 year old husband and father was fatally electrocuted when a crane at a construction site contacted an overhead power line.

EFCOG Electrical Improvement Project Three people were killed at a concrete plant in Telford, PA when a crane struck a 7,200 volt electrical power line. The crane operator was electrocuted immediately, and two co-workers were themselves electrocuted when they attempted to rescue the operator.

EFCOG Electrical Improvement Project Be Aware of Overhead Electrical Lines When Operating Dump Trucks On September 21, 2005, at the Hanford Central Waste Complex, the raised bed of a dump truck operated by a subcontractor hit an energized 240-volt power line, producing an electrical arc as the line was severed. The driver exited the truck without waiting for verification that the line was de-energized, but was not injured.

EFCOG Electrical Improvement Project On Feb. 22, 1994, Lloyd Alfred "Al" Battle, on assignment for CNN in Alexandria, Va., was killed after he raised the mast of his ENG van into a 19,900 volt power line. A survival guide for those in television who raise the mast

EFCOG Electrical Improvement Project Planning for Work Near Overhead Power Lines Walk down and survey the work site before beginning the work to identify all overhead power lines. Consider equipment travel paths and movement. LOOK UP! All overhead power lines shall be considered energized until proven otherwise. Contact the owner of the lines to determine the voltage of the lines and request the lines be de- energized and grounded. NEVER ACCEPT WORKING NEAR AN ENERGIZED LINE UNLESS ITS NOT FEASIBLE TO DE-ENERGIZE IT.

EFCOG Electrical Improvement Project Power Line Clearances Know the power line clearance requirements (Refer to NFPA 70E for safe approach distances) –For lines 50kV or less, the operator must keep all equipment parts and personnel at least 10 feet away –For lines above 50kV, this distance increases by 4 inches for each kV over 50kV Determine your safe working clearance (the closest you can place equipment or personnel without crossing the buffer zone)

EFCOG Electrical Improvement Project Safe Practices for Working Near Energized Overhead Lines Implement a two barrier control system to maintain effective standoff distances. Examples include: –Use trained dedicated spotters that maintain radio contact with operator. Ensure spotters understand hand signals. Use of radios is preferred for communications. –Use physical barriers that prevent equipment from intrusion (insulation blankets, etc.) –Use stakes, cones, and painted lines to remind operators of demarcation lines

EFCOG Electrical Improvement Project Two Barrier Control Other examples of controls include: –Procure and use remote measurement techniques and equipment to determine actual clearance distances –Use reflective materials to enhance visual identification of spotter by equipment operators –Disable equipment functions to prevent rotation, elevation, extension or movement of components to prevent inadvertent contact

EFCOG Electrical Improvement Project Other Considerations Have a brief job site meeting to discuss the planned work as it relates to the power lines. Discuss topics such as the use of long-handled tools, and equipment (raised dump trucks, back hoes, etc.) that could come in contact with the lines. Consider the two barrier controls. Prohibit work when environmental conditions warrant (fog, precipitation, smoke, darkness, etc.) Only use nonconductive ladders and material handling equipment. Aluminum ladders and metal scaffolds or frames are efficient conductors of electricity.

EFCOG Electrical Improvement Project Other Considerations Consider grounding mobile equipment Avoid storing materials under or near overhead power lines. Always STAY ALERT when working near power lines. Monitor actions of others and stop work if required to reduce risk of contact.

EFCOG Electrical Improvement Project Electrical Hazards for Crane and Heavy Equipment Operators The crane is the most common type of equipment which most often contacts overhead power lines. When contact happens, the rigger or ground worker is most often electrocuted (90% of time)

EFCOG Electrical Improvement Project Safe Practices Operating Cranes and Mobile Equipment Make it a HABIT to look up before you unload or load a crane from a truck or lowboy. Make sure there are no overhead lines before you start. Operate equipment at a slower-than-normal rate in the vicinity of power lines. Exercise caution near long spans of overhead power lines, since wind can cause the power lines to sway laterally and reduce the clearance between the crane and the power line. Mark safe routes where equipment must repeatedly travel beneath power lines. Exercise caution when traveling over uneven ground that could cause the crane to weave or bob into power lines. Keep all personnel on ground well away from the crane whenever it is close to power lines. Prohibit persons from touching the crane or its load until a signal person indicates that it is safe to do so.

EFCOG Electrical Improvement Project Dump Truck Contacting Power Lines

EFCOG Electrical Improvement Project Electrical Hazards for Dump Truck Operators Make it a HABIT to Look up before you raise a dump bed. Make sure there are no overhead lines before you start. Always look up before you pull forward or move your truck with the dump bed extended upward.

EFCOG Electrical Improvement Project Electrical Hazards for Painters and Material Handlers Material Handling is such a common activity on a job site that most workers don’t give it a second thought.

EFCOG Electrical Improvement Project Safe Practices Handling Material and Ladders When working around overhead electric lines or with electrical equipment, use non-conductive ladders and tools Never attempt to carry a ladder in a vertical position. Ladders should be lowered and turned horizontally when transported from one location to another. Extension ladders should be collapsed before lowering from a vertical position. Unload materials from trucks and flatbeds away from overhead lines

EFCOG Electrical Improvement Project If Your Equipment Makes Contact with Power Line Stay on the equipment and wait until the line is de- energized by the power company If you must leave the equipment, such as in a fire, jump clear and attempt to land with both feet together. –Do not touch any part of the equipment when contacting the ground –Shuffle away from equipment in small steps while keeping feet together

EFCOG Electrical Improvement Project Power Line Contact DO NOT allow anyone on ground to come near or touch the machine. Warn personnel to stay away from the machine. Never touch a person who is in contact with a live power line. Call for help and get power line de-energized.