. Level 3 Air Conditioning Inspections for Buildings

Slides:



Advertisements
Similar presentations
Chapter 3. HVAC Delivery Systems
Advertisements

Heating, Ventilating, and Air-Conditioning
Technical Committees – the Brains of ASHRAE Section 1.0 — Fundamentals and General.
Ductless Heat Pumps in Residential Applications Proposed Research Plan.
ASHRAE Presentation: VRF Overview Mitsubishi Electric Presenter: Phone number ©2011 Mitsubishi Electric& Electronics USA, Inc.
Domestic GDA Training – Annex F – ECO Regulations1Training Material © Stroma Certification 2012 | Version 1.0 ABBE Level 3 Diploma in Domestic Green Deal.
Domestic GDA Training – 1. Welcome & Housekeeping1Training Material © Stroma Certification 2013 | Version 1.1 ABBE Level 3 Diploma in Domestic Green Deal.
Air Conditioning Systems
The new Super Multi from TCUK
Air-Source Heat Pumps I North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed. Airsource Heat Pump 1.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee March 27, 2013 Mira Vowles, P.E., CEM Emerging.
How a Heat Pump Works By: Adam Meeker. What is a Heat Pump? A heat pump is a device which transfers heat energy from one place to another.
N O R T H A M E R I C A C O M M E R C I A L TDP
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 22, 2012 Mira Vowles, P.E., CEM.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee June 12, 2014 Mira Vowles, P.E., CEM Emerging.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 27, 2013 Mira Vowles, P.E., CEM.
Remember... Resistance in Mechanical systems (friction) opposes motion of solid objects.
Keeps heat indoors in winter and outdoors in summer – means lower heating and cooling bills Rated by it’s R-value. The greater the R- value the better.
System Appliances Division Training Manual MODERATO-P/J -. AQ09MSB -. AQ12MSB -. AQ18MSB -. AQ24MSB.
Thermal Physics III Cooling Processes Refrigerators, air conditioners, and heat pumps are devices that make heat flow from cold to hot. This is called.
Systems and Applications Basic Types Direct Expansion Air-WaterAll-AirAll-Water.
By: Peter Francis Sarabosing
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee July 24, 2013 Mira Vowles, P.E., CEM Emerging.
Geothermal. Defining “Geothermal” Energy Dictionary definition – Relating to the internal heat of the earth The Earth acts as a giant solar collector,
Chapter 32 Heating, Ventilation, and Air Conditioning.
. Level 3 Air Conditioning Inspections for Buildings 5. Mechanical Refrigeration (Day 2) PRESENTED BY Anthony Balaam
. Level 3 Air Conditioning Inspections for Buildings 10. CIBSE TM44 Reporting Methodology (Day 3) PRESENTED BY Anthony Balaam
LEVEL 4 RENEWABLE TECHNOLOGIES TRAINING RENEWABLE ENERGY TECHNOLOGIES.
. Level 3 Air Conditioning Inspections for Buildings 7. Compressors (Day 2) PRESENTED BY Anthony Balaam
Solar Water Heater System Suppliers in UAE
LEVEL 4 BUILDING SERVICES TRAINING Level 3 Re-cap Cooling Systems looked at within Level 3 included; –Through-the-wall packages –Individual reversible.
CHIGO HVAC Product Introduction.
Maria’s Restaurant Chapter 2 Section 6
Level 3 Air Conditioning Inspections for Buildings
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
. Level 3 Air Conditioning Inspections for Buildings
. Level 3 Air Conditioning Inspections for Buildings
. Level 3 Air Conditioning Inspections for Buildings
E4 HVACR Electrical Installation
.. Level 3 Air Conditioning Inspections for Buildings
ABBE Level 4 DipACEA. Air Conditioning Energy Assessors Inspections course Day 2. 19, Next Steps after Training PRESENTED BY Anthony Balaam
Special-Purpose Outlets— Electric Heating, Air Conditioning
PHOTO GALLERY Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 7th edition by Yunus A. Çengel and Michael A. Boles.
. Level 4 Air Conditioning Inspections for Buildings Day 1.
Level 3 Air Conditioning Inspections for Buildings
. Level 3 Air Conditioning Inspections for Buildings
Level 3 Air Conditioning Inspections for Buildings
. Level 3 Air Conditioning Inspections for Buildings
E4 HVACR Electrical Installation
BUILDING HEATING AND COOLING
Heating, Ventilating, and Air Conditioning
Heating Ventilating and Air Conditioning
Energy- and mass flows in cooling and in heat pumps
. Level 3 Air Conditioning Inspections for Buildings
. Level 3 Air Conditioning Inspections for Buildings
Types of HVAC Technology Used in Business Establishments
. Level 3 Air Conditioning Inspections for Buildings Day 1.
Section 3: Using Thermal Energy
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Section 1.0 — Fundamentals and General
Lecture Objectives: Answer questions related to HW 4
Heating, Ventilating, and Air-Conditioning
. Level 3 Air Conditioning Inspections for Buildings 15. User Controls
R3 Controls, Valves, Accessories & Heat Pumps
Lecture Objectives: Discus Final Project Learn about Solar Systems
Lecture Objectives: Discuss HW4 parts
FBE03: Building Construction & Science
Choosing Energy Efficient Heating Systems For Your Home Your home can be heated in a variety of ways, as there are many different types of heating systems.
Level 3 Air Conditioning Inspections for Buildings
Household Circuits Can u count how many different things your home require electrical energy? You cant see the wires because they are hidden behind your.
Presentation transcript:

. Level 3 Air Conditioning Inspections for Buildings 3. Unitary & Packaged Units for L3 Competent Air Conditioning Assessors (Day 1) PRESENTED BY Anthony Balaam aircon@stroma.com

L3 Packaged System Unitary Packaged Units:- Indoor and outdoor components in self-contained ‘unitary’ package. Installed as ‘through the wall unit’. May be reversible if a heat pump. May have electric resistance heater. Unitary packaged units: the indoor and outdoor units are both contained in a self-contained ‘unitary’ housing, often installed as a ‘through the wall’ unit. The unit may be reversible allowing operation as a heat pump, or electric resistance heating may be included.

L3 Packaged System

L3 Packaged System Also referred to as ‘split packaged units’. Individual Split Systems:- Also referred to as ‘split packaged units’. HEAT REJECTION REFRIGERANT CIRCUIT COOLING Maximum length depends on the manufacture but as a guide about 30m Split packaged units: a single indoor unit is connected by refrigerant pipework to a single outdoor unit. The indoor unit may be floor, wall or ceiling mounted. The unit may be reversible allowing operation as a heat pump, or electric resistance heating may be included. HEAT REJECTION REFRIGERANT CIRCUIT COOLING INDOOR UNIT OUTDOOR UNIT

L3 Packaged System Also referred to as ‘multi-split packaged units’. Multi-Split Systems:- Also referred to as ‘multi-split packaged units’. HEAT REJECTION REFRIGERANT CIRCUIT Multi-split packaged units: a number of indoor units are connected to a common outdoor unit by their own dedicated refrigerant pipework. The indoor units may be floor, wall or ceiling mounted. The system may be reversible allowing operation of all the indoor units as heaters in heat pump mode, or electric resistance heating may be included. DISTRIBUTION PIPES SINGLE or MULTIPLE OUTDOOR UNITS MULTIPLE INDOOR UNITS

(CAN HAVE VARIABLE FLOW) L3 Packaged System Variable Refrigerant Flow (VRF) Systems Allows variable control of different branches. REFRIGERANT CIRCUITS (CAN HAVE VARIABLE FLOW) HEAT REJECTION Variable refrigerant flow ( VRF) systems: a number of indoor units are connected to a common outdoor unit by refrigerant pipework on a common network. The indoor units may be floor, wall or ceiling or mounted. Each indoor unit may operate to provide either cooling or heating, allowing heat transfer between zones that require cooling and those that require heating, with the outdoor unit operating in heat rejection or heat pump mode as necessary. REFRIGERANT CIRCUIT BRANCH CONTROL MANIFOLD SINGLE or MULTIPLE OUTDOOR UNITS MULTIPLE INDOOR UNITS

L3 Packaged System Typical layout of VRF System

LEVEL 3 Air Conditioning ENERGY ASSESSORS TRAINING ANY QUESTIONS OR FEEDBACK ON ANY SLIDE Any questions or clarity needed over this topic and slides 8

Contacts:- STROMA Certification Ltd – Contacts Web Links www.stroma.com/certification Contacts:- STROMA Certification Ltd. 4 Pioneer Way, Castleford, WF10 5QU 0845 621 11 11 training@stroma.com

End of this section