Creative Filtration and Chromatography Products

Slides:



Advertisements
Similar presentations
Chromatography Dr.Tawfeq A. Al-Howiriny Associate Professor
Advertisements

A Grace company Avoiding Matrix Interferences in Ion Chromatography Using Solid Phase Extraction Alltech Associates, Inc. Brandstraat 12, 9160 Lokeren.
For Large Scale Purification
Gas Chromatography Introduction 1.) Gas Chromatography
Chromatography Integration and Trouble-shooting
Mobile phase is a gas! Stationary phase could be anything but a gas
ENVIRONMENTAL ANALYSIS I. Solid Phase Extraction sorbent configurations – layered phases.
Separation of molecules and determination of there molecular weight by gel filtration chromatography. Experiment 7 BCH 333.
Practical HPLC. 2 In This Section, We Will Discuss: How to set up an HPLC System for a sample injection including:  Solvent Handling  Mobile Phase preparation.
KROMATOGRAFİ Sedat Türe. HPLC Liquid Chromatography.
Lecture 9 Yuri Kazakevich Seton Hall University
High Performance Liquid Chromatography. HPLC originally refered to: High Pressure Liquid Chromatography currently refers to: High Precision Liquid Chromatography.
Paper and Thin layer Chromatography
Figure 1. Influence of sample solvent on peak shape. The sample is dissolved in buffer with (a) 0%, (b) 30%, (c) 50%, and (d) 70% acetonitrile. Sample.
1 Chapter 25 HPLC High-Performance Liquid Chromatography.
Chem. 31 – 4/8 Lecture. Announcements I Exam 2 – Monday –Covering Ch. 6 (topics since exam 1), 7, 8-1, 17, and parts of 22 (up to and including retention.
Chem. 133 – 5/5 Lecture. Announcements Lab Report 2.4 due Thursday – can turn in today for reduction of late penalties Term Project Progress Report –
Experiment 4 Thin Layer Chromatography. Silica gel (SiO2) glass or aluminum plate edge view.
Column Chromatography. Types of columns: 1- Gravity Columns: The mobile phase move through the stationary phase by gravity force. 2- Flash Columns (Air.
High-Performance Liquid Chromatography HPLC, when GC won’t cut it!!!
Close your books and take out a piece of paper. Give an example of each of the following. 1)Element that exist as a solid at room temperature (298.15K)
Gel Filtration Chromatography.
Pn. Suryati Bt. Syafri 2009 High Performance Liquid Chromatography (HPLC)
CHAPTER 29 Supercritical Fluid Chromatography The mobile phase is a supercritical fluid (a fluid above its critical T and critical pressure) Supercritical.
Solvents, Recrystallization, and Melting Point
EXTRACTION: solvent partition crude extract hexane-solubles ethyl ether-solubles ethyl acetate-solubles 1-butanol-solubles polar residues water-solubles.
ENVIRONMENTAL ANALYSIS I. Solid Phase Extraction example - triazines.
HIGH PRODUCTION VOLUME CHEMICALS – UNDERSTANDING THE POLLUTION PREVENTION IMPLICATIONS Professor Michael Overcash Department of Chemical and Biomolecular.
High Performance Liquid Chromatography
Flash Chromatography 150 & 300 ml/min Flash Pumps New 200 ml/min Binary Flash Pump.
High Performance Liquid Chromatography (HPLC) Jeannette Comeau CHEE April 2004.
SPT-Soft Pack Technology. Produce the best HPLC columns !
High Performance Liquid Chromatography Instrumentation.
Experimental Hypothesis The experimental hypothesis is that the process of steam distillation will yield a higher percent recovery of Eugenol from cloves.
CONFIDENTIAL Applications for Field Service Engineers.
Acid/Base Neurtalization. Acid-Base Reactions Acid – substance that increases the H + concentration in aqueous solutions HCl → H + + Cl - H 2 SO 4 → H.
General methods for flash chromatography using disposable columns Special report Marlon Vincent V. Duro McK group meeting July 6, 2015.
Normal-phase chromatography is really not that normal. That is to say that it is used much less frequently than reversed-phase chromatography. The main.
Structure and Molecular Properties
CAN YOUR HPLC COLUMN DO THIS ?. Type B SILICA TYPE-C SILICA 
CAN YOUR HPLC COLUMN DO THIS ?. Type B SILICA TYPE-C SILICA 
Wound Drainage Suction Pumps Fill Need in Marketplace AC has developed and tooled a novel wound drainage suction pump with the following unique proprietary.
Extraction and HPLC of Hypericin Courtney Arnott Intermediate Lab Fall 2001.
Best Broken into four categories
Created with MindGenius Business 2005® Instrumentation (1) Instrumentation (1) Origins Preparative column chromatography (Glass columns) Internal diameter:
Chromatography High Performance Liquid Chromatography HPLC Chapter Dr Gihan Gawish.
Application Of Macroporous Scavengers For Parallel Synthesis Qunjie Wang, Joseph J. Kirkland, Timothy Langlois. Agilent Technologies Inc.; Lorin A. Thompson.
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
PURIFCATION OF ORGANIC COMPOUNDS
Extractions Mixture of benzoic acid, anthracene, and p-nitroaniline.
Chem. 133 – 5/3 Lecture. Announcements Lab – Term Project Progress Report Due Today – Last Assignments: Term Project Poster and Peer Review Grading (Friday,
Table 2. Summary of chromatographic methods of Terazosin in different matrices Alankar Shrivastava et al. Various Analytical Methods for the Determination.
 Laboratory technique for the Separation of mixtures  Chroma -"color" and graphein - "to write”.  Colour bands - separation of individual compounds.
Experiment 5: Chromatography
WMCTC Chromatography Workshop: 7th Feb 2017
9 Adsorption Chromatography: Normal-Phase Chromatography
High-Performance Liquid Chromatography HPLC, when GC won’t cut it!!!
Chem. 133 – 5/2 Lecture.
Extraction and Sample Purification
Professor Michael Overcash
Automation of Solid Phase Extraction Column Chromatographic Cleanup
Horizon Chromatography
Chapter 9 Column Chromatography
HPLC Applications Training
Extraction Procedure (2)
Extractions Mixture of benzoic acid, anthracene, and p-nitroaniline.
Gel Filtration Chromatography.
EFFECT OF SOLVENT POLARIRTY UP ON RF VALUES OF ALKALOIDS
BASICS OF SUPERCRITICAL FLUID CHROMATOGRAPHY
Warm-Up What is a solution? Very small particles Evenly distributed
Presentation transcript:

Creative Filtration and Chromatography Products  Luknova, Inc. 20 Cabot Blvd., Suite 300, Mansfield, MA 02048, USA Confidential

About Luknova Incorporated in Princeton, New Jersey (Feb. 2004) R&D started from the Advanced Technology & Manufacturing Center (ATMC), University of Massachusetts, Dartmouth Relocated to Boston (2009) Designed in Massachusetts by Luknova Manufactured in both U.S. and overseas. Confidential

Products - EasyFil™ filters Absolutely leak free design with ground joint – built-in peace of mind in filtration Confidential

Products - EasyFil™ filters Three welded-seals and one bump seal - absolutely leak-free Confidential

Products - EasyFil™ filters Proprietary products (patents spending) All made with polymer Safe, not fragile Leak-free Faster filtration High yield Disposable Reusable Adjustable long stem - No splashing and No molecular damage Confidential

Products - EasyFil™ filters Application advantages Speed, faster separation Save time, save solvent No contamination, disposable No bypass leakage No sample-loss to strong vacuum No splashing No molecular damage Adjustable long- and short-stem Reusable (>20 times) Construction Characs Polypropylene (PP) housing Polyethylene (PE) frit (pore size 10µm) Multiple welded-seals to prevent leakage All parts are welded together as one piece Recommended max temperature 110oC 14/20, 14/35, 24/25, and 24/40 standard joints Confidential

Products - EasyFil™ filters Solvent test We tested a variety of common solvents and found there are no apparent changes at following conditions: at the boiling points of Ethyl acetate , DMF, DMA, diethyl ether, dichloromethane, THF, hexane, and water; at concentrated H2SO4, HCl, HBr, HI, acetic acid, and TFA; at saturated NaOH and KOH solution; DMSO, at temperature of 120oC (not tested above 120oC) Confidential

Flash columns Confidential

Flash Columns – Design Five piece composition a perforated cap a sealing insert an inlet filter an outlet filter a column body Features Easy assembly and disassembly Easy sample recovery and load Easy sorbent packing/repacking Disposable and reusable Confidential

Flash Columns – Performance Date: March 6, 2009 Column: Luknova 40g silica Gradient: 0 to 50% EA/Hexane Run length: 15 min Detection wavelength: 254 nm Monitor wavelength: 280 nm Flow rate: 40 mL/min Equilibration volume: 235 mL Initial waste: 0 mL Column: Luknova 40g prepacked standard flash column. Sample: A total volume 390 µL of 1:1:1 ratio of toluene, phthalic acid dimethyl ester, and phthalic acid diethyl ester mixed with 500µL methylene chloride. Solvent: Hexane (A) and Ethyl Acetate (B). Instrument: CombiFlash system. Confidential

Performance – Luknova vs. ISCO Luknova column did reach baseline separation Isco RF column ISCO column did not reach baseline separation Confidential

Products – QC Control Luknova’s 5-Component QC Standard Accurate Results Quicker More efficient Symmetric peaks Sharper peaks No fronting No doubling No overlapping High yield No compound decomposition Reliable purification Consistent performance Confidential

A variety of flash columns Silica columns 4g-1500g 50 and 25µm particles Specialty columns Amine, Cyano, Diol, Florisil, Alumina (basic, neutral, acid) C4, C8, C18, C30, Cyclohexyl, Phenyl WCX, SCX, SCX-2, SAX, and WAX Mixed phases Confidential