Summary of experience with Tevatron synchrotron light diagnostics

Slides:



Advertisements
Similar presentations
Short bunches in SPEAR J. Safranek for the SPEAR3 accelerator group November 2, 20101J. Safranek CLS THz Workshop.
Advertisements

FNAL Emittance Devices Flying Wires (FW) Sync Lite Ion Profile Monitors (IPM) aah,6/20/2000.
Low energy electron beam as a nondestructive diagnostic tool for high power beams. P. Logachev, D. Malutin, A. Starostenko, BINP, RUPAC’2006, Novosibirsk.
1 Scintillating Fibre Cosmic Ray Test Results Malcolm Ellis Imperial College London Monday 29 th March 2004.
Resonance crossing and error tolerances Shinji Machida KEK FFAG05 at Fermilab, April 3-7, 2005.
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
BSRT Optics Design BI Days 24 th November 2011 Aurélie Rabiller BE-BI-PM.
Matching and Synchrotron Light Diagnostics F.Roncarolo, E.Bravin, S.Burger, A.Goldblatt, G.Trad.
Searching for Quantum LOVE at the Australian Synchrotron Light Source Eugene Tan On behalf of Rohan Dowd 120/10/2010Eugene Tan – IWLC 2010, Genega ASLS.
9/25/031 First Tests of an Optical Transition Radiation Detector for High-Intensity Proton Beams at FNAL September 25, 2003 Vic Scarpine.
Simulation of direct space charge in Booster by using MAD program Y.Alexahin, N.Kazarinov.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Emittance Growth from Elliptical Beams and Offset Collision at LHC and LRBB at RHIC Ji Qiang US LARP Workshop, Berkeley, April 26-28, 2006.
Research in Particle Beam Physics and Accelerator Technology of the Collaboration IKP Forschungszentrum Jülich & JINR A.N. Parfenov for the Collaboration.
SPS Synchrotron Light Monitor -BSR- Status G. TRAD E. Bravin, A. Goldblatt, F. Roncarolo.
05/05/2004Cyrille Thomas DIAMOND Storage Ring Optical and X-ray Diagnostics.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
Simulation of direct space charge in Booster by using MAD program Y.Alexahin, A.Drozhdin, N.Kazarinov.
C. Fischer – LHC Instrumentation Review – 19-20/11/2001 Gas Monitors for Transverse Distribution Studies in the LHC LHC Instrumentation Review Workshop.
Development of a Gamma-Ray Beam Profile Monitor for the High-Intensity Gamma-Ray Source Thomas Regier, Department of Physics and Engineering Physics University.
Tests of AWAKE spectrometer screen and camera at PHIN Introduction Layout Procedure Setup, results (runs 1 – 5) Conclusions L. Deacon, S. Mazzoni, B. Biskup.
1 Simulations of fast-ion instability in ILC damping ring 12 April ECLOUD 07 workshop Eun-San Kim (KNU) Kazuhito Ohmi (KEK)
SPATIAL RESOLUTION OF NON- INVASIVE BEAM PROFILE MONITORBASED ON OPTICAL DIFFRACTION RADIATION A.P. Potylitsyn Tomsk Polytechnic University, , pr.
Abort Gap Monitoring Randy Thurman-Keup 6 / 8 / 2004 LARP Meeting.
LARP Commissioning Plans for the LHC Synchrotron-Light Monitors Alan Fisher SLAC National Accelerator Laboratory LARP CM13 Port Jefferson, NY
Tests of spectrometer screens Introduction Layout Procedure Results Conclusions L. Deacon, B. Biskup, S. Mazzoni, M.Wing et. al. AWAKE collaboration meeting,
IPM EM Simulations 9 th DITANET Topical Workshop on Non-Invasive Beam Size Measurement for High Brightness Proton and Heavy Ion Accelerators April.
NON-INTERCEPTING DIAGNOSTIC FOR HIGH BRIGHTNESS ELECTRON BEAMS USING OPTICAL DIFFRACTION RADIATION INTERFERENCE (ODRI) A. Cianchi #1,2, M. Castellano 3,
10/5/2005 jrz1 Not quite “All” you want to know about Flying Wires At Fermilab Jim Zagel 10/5/2005.
XBSM Analysis - Dan Peterson Review of the optics elements: Pinhole (“GAP”), FZP, Coded Aperture Extracting information from the GAP what is the GAP width?
Robert R. Wilson Prize Talk John Peoples April APS Meeting: February 14,
2 February 8th - 10th, 2016 TWIICE 2 Workshop Instability studies in the CLIC Damping Rings including radiation damping A.Passarelli, H.Bartosik, O.Boine-Fankenheim,
Measurements of Intense Proton Beams using Optical Transition Radiation Vic Scarpine, Fermilab TIPP 2011 Chicago, IL June 10, 2011.
F Monitor of Beam in the Abort Gap Randy Thurman-Keup DOE Review of Tevatron Operations at FNAL March 29-31, 2005 a.k.a. Abort Gap Integrator (AGI)
What did we learn from TTF1 FEL? P. Castro (DESY).
IBS and Touschek studies for the ion beam at the SPS F. Antoniou, H. Bartosik, Y. Papaphilippou, T. Bohl.
Ultra-low Emittance Coupling, method and results from the Australian Synchrotron Light Source Rohan Dowd Accelerator Physicist Australian Synchrotron.
ESLS Workshop Nov 2015 MAX IV 3 GeV Ring Commissioning Pedro F. Tavares & Åke Andersson, on behalf of the whole MAX IV team.
ODR Diagnostics for Hadron Colliders Tanaji Sen APC.
SDA- Shot Data Analysis Jean Slaughter DOE Review July 21, 2003.
G. Trad on the behalf of the BSRT team Emittance meeting 04/11/2015.
IPM Simulations at Fermilab 3-4 March 2016 Randy Thurman-Keup.
Development of Multi-Pixel Photon Counters (1)
Ion Profile Monitors _ 2017 Jim Zagel GSI - IPM17 Workshop
FCC-ee Interaction Region design
EZDC spectra reconstruction and calibration
E. Ponce2-1, G. Garipov2, B. Khrenov2, P. Klimov2, H. Salazar1
E-beam scanner experience at FNAL
Beam-beam effects in eRHIC and MeRHIC
IMAGE ORTHICON.
Large Booster and Collider Ring
Lebanese Teacher Programme 18/04/2017
Longitudinal Effects in Space Charge Dominated Cooled Bunched Beams
Coupling Correction at the Australian Synchrotron
OTR based measurements for ELI-NP Gamma Beam Source
First Attempt to Simulate the Shielded Button Measurements with ECLOUD
Instrumentation for Colliding Beam Physics 2017
High resolution profile measurements
Department of Physics and Astronomy,
Electron cloud studies at CESR
High Level Physics Applications for LCLS Commissioning
Gain Computation Sven Reiche, UCLA April 24, 2002
Transverse size and distribution of FEL x-ray radiation of the LCLS
Linac Diagnostics Commissioning Experience
Bunch Profiling with a Rotating Mask
Diagnostics overview Beam profile monitors Cherenkov radiators Summary
MEIC Alternative Design Part V
LHC BIF test setup - update
Optimization of JLEIC Integrated Luminosity Without On-Energy Cooling*
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

Summary of experience with Tevatron synchrotron light diagnostics 9th DITANET Topical Workshop on Non-Invasive Beam Size Measurement for High Brightness Proton and Heavy Ion Accelerators 15-18 April 2013 Randy Thurman-Keup Fermilab

9th DITANET Topical Workshop -- R. Thurman-Keup Tevatron 1985(?)-2011 Collided 980 GeV protons and antiprotons in the same beampipe Proton intensity was ~1 x 1013 (300 x 109/bunch) Antiproton intensity was typically ~2 x 1012 (50-100 x 109 / bunch at start of store) Beams were arranged in 3 sections of 12 bunches Bunch longitudinal sigma was 2-3 ns 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Synchrotron Radiation Monitors Original creation by Alan Hahn and Pat Hurh early 1990’s 2 profile monitors: one for protons, one for antiprotons 2 abort gap beam intensity monitors Proton Gated Abort Gap PMT Antiproton Intensified CID Cameras 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Synchrotron Radiation Devices Pickoff Mirrors Protons Antiprotons Half-Dipole Dipole Dipole Proton Antiproton Near Far Proton light source Antiproton light source Proton’s Eye View Antiproton Pick-off Mirror Proton Pick-off Mirror 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Synchrotron Radiation Devices Abort Gap Monitor Focusing lens Optional attenuator Beam Splitter Gated Hamamatsu MCP-type PMT Profile Monitor Focusing lens Optional attenuator Beam Splitter ~400 nm filter Hamamatsu Image Intensifier CID Camera (Rad tolerant) 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

9th DITANET Topical Workshop -- R. Thurman-Keup Antiproton Light 200 nm 300 nm 400 nm Synchrotron Radiation Workshop (SRW) used extensively to understand various effects These images are SRW simulations of illumination at the antiproton pickoff mirror Antiproton source is two edges, hence the interference structure at 200 nm 500 nm 600 nm 700 nm 800 nm 900 nm 1000 nm 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Profile Measurement, aka Synclite After object… Object Efficiency # of photons / bunch / 25 nm Protons Antiprotons Magnet Edge — 750,000 Pickoff Mirror 90% 675,000 Vacuum Window 608,000 Lens 93% 565,000 x-y Mirror 509,000 Beam Splitter 44% 224,000 x-y Mirror (proton only) 202,000 Wavelength Filter 10 nm 40% 40 nm 160% 81,000 358,000 Photocathode 14% 11,000 p.e. 50,000 p.e. Proton Object Distance = 769 cm Proton Image Distance = 187 cm Proton Optical Magnification = 0.24 Antiproton ½ Dipole Object Distance = 503 cm Antiproton Full Dipole Object Distance = 544 cm Antiproton Image Distance = 85 cm Antiproton Optical Magnification = 0.17 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

9th DITANET Topical Workshop -- R. Thurman-Keup Acquisition Camera image acquired through LabVIEW program Image consisted of a variable number of turns to optimize image intensity bunch-by-bunch Dark current image subtracted Line-by-line linear background subtracted from image Horizontal and Vertical Profiles fit with gaussian plus linear background Emittance evaluated from beam size plus lattice parameters plus dp/p 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Intensity Effects on Measured Size 4 sources of intensity variation in the system Intensifier gain Intensifier gating duty cycle Intensifier gating voltage Synchrotron radiation intensity All intensity effects can be parameterized with image intensity 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Intensity Effects on Measured Size 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

9th DITANET Topical Workshop -- R. Thurman-Keup Diffraction Classical diffraction Plot is measured sigma vs. wavelength Data points are taken with 10 nm bandwidth filters Red points are SRW simulation 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

9th DITANET Topical Workshop -- R. Thurman-Keup Diffraction SRW simulation of diffraction as a function of sigma Proton simulations agree with classical but antiproton does not Diffraction varies across image Presumably due to multiple source points and/or body light Classical Vertical Classical Horizontal 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

9th DITANET Topical Workshop -- R. Thurman-Keup Camera Focus Because synchrotron radiation is not a point source, focusing is a more complicated issue Particularly in the antiproton case with 2 magnet edges 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Impact of Extended Source 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

9th DITANET Topical Workshop -- R. Thurman-Keup Proton Mirror Study Moved the pickoff mirror which selected differing contributions of light 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Antiproton Mirror Study 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Resolution vs. Position on Intensifier Variation of measured sigma as a function of position on the intensified camera RMS is < 10 mm Saw signal degradation towards end of Tevatron 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Synclite vs. Flying Wire Overall resolution term obtained by flattening the comparison within store (red lines) Pre 2006 shutdown 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Synclite vs. Flying Wires Post 2006 shutdown 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Synclite vs. Flying Wire Variation from store to store 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

9th DITANET Topical Workshop -- R. Thurman-Keup Synclite Use With the advent of electron cooling Antiproton beam too bright Proton beam emittance growth Poor luminosity lifetime So… uncool the antiprotons a bit Noise source kicker Synclite antiproton signal as feadback 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

9th DITANET Topical Workshop -- R. Thurman-Keup Abort Gap Monitor PMT is a Hamamatsu 3-stage MCP type PMT charge signal is integrated for a specified duration and digitized Critical time was during the early part of the gap in which the abort kicker would fire The table below lists the number of photons or or photoelectrons after a particular optic element 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Abort Gap Monitor Calibration Calibration of the abort gap monitor via Baseline-subtracted DCCT signal Tevatron Electron Lens (abort gap cleaner) 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

9th DITANET Topical Workshop -- R. Thurman-Keup Pedestal Algorithm Pedestals have two components A beam-off pedestal A beam-on non-gated pedestal Tracks changes over time 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Beam Growth Between Bunches Tevatron Electron Lens keeps the level low in the gaps 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

Bunched Beam From Main Injector Measurements in photon counting mode Bunch 36 is 2 microsecs to the left of this plot The red crosses show my best guess at the location of the center of the buckets. 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup

9th DITANET Topical Workshop -- R. Thurman-Keup Conclusions Synclite Worked well Should have had a uniform illumination calibration source (actually did, but not very uniform) Should have measured the optical resolution Planned to but didn’t finish it 16 April 2013 9th DITANET Topical Workshop -- R. Thurman-Keup