Mithun Gudipati, Venkata Venigalla

Slides:



Advertisements
Similar presentations
WCB/McGraw-Hill © The McGraw-Hill Companies, Inc.,1998 Thermodynamics Çengel Boles Third Edition 13 CHAPTER Gas-Vapor Mixtures and Air-Conditioning.
Advertisements

Fig. 4-1, p Fig. 4-2, p. 109 Fig. 4-3, p. 110.
ME 322: Instrumentation Lecture 35 April 18, 2014 Professor Miles Greiner.
LabVIEW 7.1 Tutorial. Measurement Lab. MECH262-MECH261 Imran Haider Malik January 16, 2006.
ME 322: Instrumentation Lecture 33 April 14, 2014 Professor Miles Greiner.
ME 322: Instrumentation Lecture 24 March 23, 2015 Professor Miles Greiner Lab 9 calculations.
ME 322: Instrumentation Lecture 32 April 10, 2015 Professor Miles Greiner.
ME 322: Instrumentation Lecture 21
ME 322: Instrumentation Lecture 18 March 2, 2015 Professor Miles Greiner TC signal conditioner, Computer data acquisition introduction, Lab 7, myDAQ, LabVIEW.
ME 388 – Applied Instrumentation Laboratory Temperature Measurement Lab.
ME 322: Instrumentation Lecture 17
P.464. Table 13-1, p.465 Fig. 13-1, p.466 Fig. 13-2, p.467.
P449. p450 Figure 15-1 p451 Figure 15-2 p453 Figure 15-2a p453.
Volume & Temperature Relationship
Fig. 11-1, p p. 360 Fig. 11-2, p. 361 Fig. 11-3, p. 361.
ME 322: Instrumentation Lecture 40 April 29, 2015 Professor Miles Greiner Review Labs 10 and 11.
ME 322: Instrumentation Lecture 39
Table 6-1, p Fig. 6-1, p. 162 p. 163 Fig. 6-2, p. 164.
ME 322: Instrumentation Lecture 20 March 6, 2015 Professor Miles Greiner myDAQ A/D converter, temperature uncertainty, First-order, centered numerical.
ME 411/511Prof. Sailor Data Acquisition & LabView Lecture goals… –Learn the basics of how to use and modify LabView Virtual Instruments –Become familiar.
ME 322: Instrumentation Lecture 23 March 13, 2015 Professor Miles Greiner Transient TC response, Modeling, Expected and observed behaviors, Lab 9, Plot.
ME 322: Instrumentation Lecture 22 March 11, 2015 Professor Miles Greiner.
MECH 322 Instrumentation Sinan Ozcan: I believe, I performed 50% of the work. Soma : I believe, I performed 50% of the work. Transient Thermocouple Response.
MECH 322 Instrumentation Feedback Temperature Control Performed: 04/20/06 Pablo Araya : I believe I performed 100% of this lab Participation (__/50 points)
Temperature and Heat.
MECH 322 Instrumentation Lab 7 Computer Data Acquisition System for Steady Thermocouple Signals Performed: March 6, 2007 Group 0 Miles Greiner Lab Instructors:
ME 322: Instrumentation Lecture 37 April 22, 2015 Professor Miles Greiner Proportional control characteristics, Shift register and integral control program.
PSC 151 Laboratory Activity 6 Temperature and the Thermometer.
MECH 391 Instrumentation Lab 9 Vibration Analysis of an Aluminum Cantilever Beam Performed: 03/15/04 Sinan Ozcan : I believe I performed 100% of this lab.
ME 322: Instrumentation Lecture 38 April 24, 2015 Professor Miles Greiner Integral Control.
MECH 322 Instrumentation Lab 5 Elastic Modulus of an Aluminum Beam Performed: February 9, 2014 Group 0 Miles Greiner Lab Instructors: Mithun Gudipati,
Lab 3 Static Calibration of Manometers Using Electronic Pressure Transmitters Lab Instructor: A. Sunkara Performed: January 27, 2005, 10 AM Miles Greiner.
MECH 322 Instrumentation Performed: 03/15/06 Differentiation and Spectral Analysis of Discretely Sampled Signals Group 0 Pablo Araya Lab Instructors: Mithun.
MECH 322 Instrumentation Lab 5 Elastic Modulus of an Aluminum Beam Performed: February 13, 2007 Group 0 Miles Greiner Lab Instructors: Mithun Gudipati,
Lab 3 Static Calibration of Electronic Pressure Transmitters using Manometers February 1, 2013 Group 0 Miles Greiner Lab Instructors: Michael Goodrick.
MECH 322 Instrumentation Lab 9 Transient Thermocouple Response in Water and Air Performed: 03/23/07 Group 0 Miles Greiner Lab Instructors: Mithun Gudipati,
Pressure Law.
ME 322 LAB 7 Computer Data Acquisition System for Steady Thermocouple Signals Performed : 02/13/2004 Sinan Ozcan : I believe I performed 50% of this lab.
MECH 322 Instrumentation Lab 6 Fluid Speed and Volume Flow Rate Performed: February 27, 2007 Group 0 Miles Greiner Lab Instructors: Mithun Gudipati, Venkata.
ME 322: Instrumentation Lecture 31 April 8, 2015 Professor Miles Greiner.
MECH 322 Instrumentation Lab 10 Damped Vibration of a Weighted Cantilever Beam Performed: 4/1/15 Group 0 Miles Greiner Lab Instructors: Marissa Tsugawa.
Vadodara institute of engineering Harshang shah( )
MECH 391 Instrumentation Lab 11 Unsteady Velocity in a Karman Vortex Street Performed: 04/07/05 Sinan Ozcan: I believe I performed 50% of this lab Participation.
Chapter 14 Gas-Vapor Mixtures and Air-Conditioning Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 8th edition.
Figure 4.1 Computerized data-acquisition system.
Dalton’s Law of Partial Pressures
Lithium + Magnesium Hydroxide 
ME 322: Instrumentation Lecture 41
ME 322: Instrumentation Lecture 34
ME 322: Instrumentation Lecture 23
ME 391 LAB#5 Construction of a Computer Data Acquisition System for Measuring Steady Thermocouple Signals Performed : 02/13/2004 Sinan Ozcan : I believe.
TEMPERATURE.
Chemical Engineering Explained
Insert Title of Lab Here
Temperature and Thermometers
P1V1 = P2V2 (99.0 kPa) (300.0 mL) = (188 kPa) V2
Figure 20.1  Joule’s experiment for determining the mechanical equivalent of heat. The falling blocks rotate the paddles, causing the temperature of the.
Figure 20.1  Joule’s experiment for determining the mechanical equivalent of heat. The falling blocks rotate the paddles, causing the temperature of the.
P1V1 = P2V2 (99.0 kPa) (300.0 mL) = (188 kPa) V2
Figure 19.6  Absolute temperatures at which various physical processes occur. Note that the scale is logarithmic. Fig. 19.6, p. 585.
ENGR 2213 Thermodynamics F. C. Lai School of Aerospace and Mechanical
Basic Chemistry Chapter 11 Gases Chapter 11 Lecture
Gases and Pressure Section 11.1.
Instrumentation and Control: ME- 441 Department of Mechanical Engineering UMT 1.
The University of Adelaide, School of Computer Science
Weather Prediction.
FIGURE 1-1 Examples of Voltage Ranges and Waveforms for Binary Signals
Evaporation vs. Boiling
Introduction to LabVIEW
Introduction to LabVIEW
Presentation transcript:

Mithun Gudipati, Venkata Venigalla MECH 322 Instrumentation Lab 7 Computer Data Acquisition System for Steady Thermocouple Signals Performed: March 6, 2007 Group 0 Miles Greiner Lab Instructors: Mithun Gudipati, Venkata Venigalla

ABSTRACT The temperature of boiling and room-temperature water, and an ice/water bath were measured using a mercury-in-glass thermometer and a computer data acquisition system. Measurements from both instruments were in agreement for all three baths. The measure boiling water temperatures were in agreement with the predicted saturation temperature at the measured barometric pressure.

Figure 1 VI Front Panel

Figure 2 VI Block Diagram

Fig. 3 Measured Temperature versus Time The measured temperatures are fairly constant

Table 1 Measured and Predicted Temperatures This table presents the computer data acquisition system and thermometer measured temperatures for the three baths. The temperatures from both measurement devices are in agreement for all three baths The saturation temperature at the measured barometric pressure of Patm = 87 kPa is 95.6oC (Reynolds, W.C. and Perkins, H.C., Engineering Thermodynamics, 2nd edition, McGraw Hill, 1977). This is within the confidence interval of the boiling water temperature for both measurement techniques.