MECH 391 Instrumentation Lab 9 Vibration Analysis of an Aluminum Cantilever Beam Performed: 03/15/04 Sinan Ozcan : I believe I performed 100% of this lab.

Similar presentations


Presentation on theme: "MECH 391 Instrumentation Lab 9 Vibration Analysis of an Aluminum Cantilever Beam Performed: 03/15/04 Sinan Ozcan : I believe I performed 100% of this lab."— Presentation transcript:

1 MECH 391 Instrumentation Lab 9 Vibration Analysis of an Aluminum Cantilever Beam Performed: 03/15/04 Sinan Ozcan : I believe I performed 100% of this lab

2 ABSTRACT In this experiment, the Cantilever Beam configuration was modeled as a simple spring-mass system. Then an equivalent system was built. The theoretical natural frequencies were compared with the natural frequencies obtained from the Data Acquisition System. The percentage difference between those two values ranges between 5 to 10 %. For constant length, the natural frequency of the system increases as the load decreases. For constant load, the natural frequency decreases as length increases. The damping coefficient seems to have a strong relation with the length of the beam under vibration. As length decreases, the damping coefficient of the system increases. Since all the damping ratios are less than one, the system we modeled was an under-damped system.

3 Table 1 Characteristics of an Aluminum Cantilever Beam This table presents the measured values (T,W,L,m beam ) and calculated values (E,I) of an Aluminum Cantilever Beam. Area Moment of Inertia of a beam which has a rectangular cross section can be found from the equation: I = 1/12*W*T 3.

4 Table 2 Experimental Data of the System This Table presents the values of the variables in each configuration. Equivalent mass of the system was calculated from the relation M+0.23m where m is the mass of the beam that was subjected to vibration also M value includes the masses of the screw, nut and accelerometer used during the experiment.

5 Table 3 Characteristics of an Aluminum Beam under Vibration Spring constant of the system increases dramatically as the length of the aluminum beam that is under vibration decreases. Natural Frequency of the system is also sensitive to the changes in Length and mass. The theoretical natural frequencies of the system are very close to the actual natural frequencies obtained from the Data Acquisition system. The percentage error is between 5 to 10 %. The error can be decreased by improving the experimental set-up. Since all the Damping Ratios are less than one, the System we modeled is an under-damped system.

6 Figure 1 Acceleration vs. Time Plot of Exp#1

7 Figure 2 Acceleration vs. Time Plot of Exp#2

8 Figure 3 Acceleration vs. Time Plot of Exp#3

9 Figure 4 Acceleration vs. Time Plot of Exp#4

10 Figure 5 Acceleration vs. Time Plot of Exp#5

11 Figure 6 Acceleration vs. Time Plot of Exp#6

12 Figure 7 Front Panel of the Vi Program

13 Figure 8 Block Diagram of the Vi Program


Download ppt "MECH 391 Instrumentation Lab 9 Vibration Analysis of an Aluminum Cantilever Beam Performed: 03/15/04 Sinan Ozcan : I believe I performed 100% of this lab."