Glue curing studies (contd)

Slides:



Advertisements
Similar presentations
ATLAS Module building at Glasgow
Advertisements

Die Attach Process.
Design Ash finished electric hybrid tracing to connector fields –Changes to allow for HCC-less and HCC running on one hybrid awaiting final confirmation.
The AMS-02 detector is based on a large acceptance (~0.5 m²sr) and high sensitivity spectrometer composed by a super-conducting magnet (0.8 T), cooled.
GAUGES Gauges perform an essential services in any scheme of quantity production on an interchangeable basis A gauge (or Limit Gauge) is a tool or instrument.
QA during Stave Core Assembly Stephanie Qing Yang (Oxford) 25 th Sept 2014 WP4 f2f meeting at RAL.
Stave core assembly Stephanie Yang WP4 face to face meeting, Lancaster University 20 Feb 2014.
S Pyatt Cicorel optimised welding parameters. S Pyatt 30 degree loop parameters.
TP We will identify the relationships between objects and kinetic and potential energy by completing a lab P4L a skydiver releases 1,700,000 Joules of.
June 8-th 2004W.Baldini1 Ferrara production center Ferrara production center Production Readiness Review OverviewOfOperations P R R.
Andy Blue Glasgow Update. Andy Blue WP3 Meeting UV Glue In November, I sent UV Glue, hybrid panel + jig to Anglo Production Process LTD –UK supplier of.
Received new "130nm" jigs from Liverpool and after the "module workshop" 25/3/15 at Liverpool and ready to make dummy modules New jigs need to be slotted.
Mickael Frotin– 07/06/2009 Demonstrator - Assembly ECAL meeting - London.
S Pyatt Dummy module with copper on glass sensor An adhesive tape has been identified that is suitable for dummy module building. This tape can be stuck.
Uncertainty and error Distinguish between precision and accuracy Accuracy is how close to the “correct” value Precision is being able to.
Gage Blocks Unit 12.
18 November 2010 Immanuel Gfall (HEPHY Vienna) SVD Mechanics IDM.
LPNHE activities Contribution in the development of an assembly line for highly granular calorimeters with semiconductor readout Gluing robot system Metrology.
Marc Anduze – 09/09/2008 Report on EUDET Mechanics - Global Design and composite structures: Marc Anduze - Integration Slab and thermal measurements: Aboud.
Status of production at LNF E. Dane, C. Forti, D. Pinci, A. Sarti – LHCb Muon CERN 25-may-04 Monday 24-may: closed chamber 30. Will close 2 more this week.
M. Gilchriese Module Assembly and Attachment at LBNL M. Gilchriese for F. Goozen April 2000.
Silicon /pcb assembly R Thompson, J Freestone LAL 3 June 08.
Petalet-Stavelet; 13 July Birmingham Update Gluing to mechanical sensor with Epolite (as reported earlier). 1 st hybrid – too much glue on stencil.
Birmingham Update Module bonding (Sam and Simon) Great difficulty bonding on to patterned glass ASICs. (OK on sensor). After 1 st two rows of bonds, abandon.
Fred Doherty Module Work Fred Doherty. Stave Module Building Hybrid Bonding Bonding table for the BJ820 still in workshop Modified working height of the.
S Pyatt UV glue dispensing studies on the Dima Dotmaster 1.
Accurate Robot Positioning using Corrective Learning Ram Subramanian ECE 539 Course Project Fall 2003.
Hybrid panel heated plate study Currently the curing of the ASIC glue for the hybrid panels are done at room temperature. This is a study to determine.
WP3_Bham; 10July 2014; John Wilson1 Gluing: more investigations (Simon and Sam) New clamping method provides a good base for systematic studies. Sketch.
David Bailey Gluing. Silicon /pcb assembly Previously Using Sony Robot and precision dispenser Have established acceptable glue dot parameters Dot electrical.
We have to fix the design of the flanges on the 1 st horn frame to which the target support beams are attached.
Birmingham update: making modules? ASICS to hybrid Gluing: many trials i) heated plate with silver loaded (8 hybrids i.e. 1 panel per day) ii) UV cured.
Gluing, measuring and shearing Heated plate curing Is the process feasible? Tests with 130nm hybrids Measure resulting glue thickness Determine the shear.
WP3_Bham; 29May 2014; John Wilson1 Heated plate curing Tests with 130nm hybrids and glass ASICs the glue thickness is controllable. i)Room temp curing.
A.Cheremukhin (JINR, Dubna) CMS Preshower PRR, July 5-6, 2001, CERN1 Micro-module assembly -  -module elements - alignment of the silicon sensors to the.
Gluing trials continuing: Loctite is favourite (for Dispensemaster) Bonding: exercising the machine; practising in laying down patterns (Simon and.
Simon Calibration Instructions Main Antenna Jig Peter Karlsson V2.
S Pyatt 1 UV glue dispensing studies on the Dima Dotmaster Glue gap checks.
WP3; 15 Jan 2015; John Wilson.1 Birmingham Update All back and operational after Christmas! Simon in contact with Dario Ariza at DESY re gluing (Boron.
Module Assembly Jig Status Cambridge and DESY came to Liverpool Nov. 15 th -16 th for training on module assembly – A complete jig set was sent back with.
WP3_Bham; 15May 2014; John Wilson1 Heated plate curing Tests with 130nm hybrids and glass ASICs i) Room temp curing the glue thickness is controllable.
Birmingham Status ASIC shear tests (250nm Panel with hybrids cured at room temp and with heated plate, sent to Berlin for shear testing. (Complication:
The problem is to design, construct and test the most efficient bridge within the specifications. Back to start of slide show.
Activity report from LNF Panels Soldering tests Production site and tooling status WPC miscellanea (+7 cm layout, cathode costs, aging tests)
Temperature vs. Viscosity Lab
Infrastructure & issues and solutions for ATLAS Upgrade Hybrid/Module strip bonding Fred Doherty, Joe Ashby, Fiona McEwan & Calum Gray ATLAS Upgrade Module.
ATLAS pixel module assembly flow
RAPID PROTOTYPING REVISION.
T. Bowcock University of Liverpool
Bonding study of wrapping part of PA1/2
→ need to guide UV light into gap; also beware temp effects
Ladder Assembly All tools and jigs produced Glue dispensing works
Sector 002 Assembly status report
Nikhef/Bonn LepCol meeting
ITK Strip Module Meeting; 12st October 2015
Gluing jigs for Demonstrator
UV glue dispensing studies
ATLAS Upgrade Module Bonding Trials Using Glass Asics
ATLAS ITK WP3 WP3 Bi-weekly meeting
Group meeting, 2nd Sept, 2013; JAW
Update from Birmingham
Auto Level View though eye piece Purpose
Module/Ladder Assembly
Codification of Flip Chip Knowledge
INTRODUCING THE ROYAL MAIL GROUP ADVERTISING MAIL CHRISTMAS INCENTIVE
Recruitment & Selection Process For Talent Acquisition
Honors Physics I and AP Physics
Pipette Calibration.
Survey Networks Theory, Design and Testing
Presentation transcript:

Glue curing studies (contd) Intention (collaboration: Berlin - Birmingham) glue and cure at room temp and elevated temp (+35C approx) and then shear test the glue bonds in Berlin. b) exercise our ex-SCT Dotmaster glue dispenser to see if it could be used to lay down appropriate dot patterns for UV curable glue. Immediate problem with (a) As reported at last (petalet/stave) meeting, the hybrid panel in Bham was so uneven that the hybrids fell off after gluing. Next step Make a feature of the problem? WP3_Birmingham; 16 Jan2014; John Wilson

WP3_Birmingham; 16 Jan2014; John Wilson Current plan (a) Tony has procured for us another 250nm panel, similarly uneven. Our gluing jig, originally out of shape, has been machined flat. The heights of the ASIC pads on the panel have been measured. Knowing the pad and jig dimensions, we can set the jig spacing legs so that the gaps straddle values around 80 μm. (Sam) 2 hybrids have been at room temp and 2 at elevated temp (all with glue thicknesses around 80μm); 2 hybrids have been glued at room temp with a wide range of glue thicknesses (Simon). will send to Berlin for shear testing (Ingo and Luise) in next few days. If all goes well, we shall be able check for a systematic difference between curing at room and elevated temps and also for a dependence of glue strength with spacing (jig to ASIC pad). WP3_Birmingham; 16 Jan2014; John Wilson

WP3_Birmingham; 16 Jan2014; John Wilson Current plan (b) Before Christmas, Simon has been exercising the Dotmaster with the 3 UV curable glues, sent by Luise and Ingo. Lots of results which were discussed with Ingo, Luise and Denis last Friday. Please see a selection of Simon’s slides next. WP3_Birmingham; 16 Jan2014; John Wilson

UV glue dispensing studies on the Dima Dotmaster S Pyatt UV glue dispensing studies on the Dima Dotmaster WP3_Birmingham; 16 Jan2014; John Wilson

WP3_Birmingham; 16 Jan2014; John Wilson S Pyatt The study involves the testing of 3 UV cure glues, received from Berlin. The candidates are: Loctite 3525 Dymax 6-621 Dymax 3013 Two dot pattern types have been defined, a five dot pattern and a one dot pattern. Due to time constraints this study will focus on the five dot pattern only. There are several steps to the testing procedure, they are: Dispensing feasibility. Can the glue be dispensed and what setup is required for the Dima Dotmaster glue dispenser? Dispensing timing step test. Stepping through different dispense times until a target dispense time duration is indentified which gives the correct mass of glue. Dispensing consistency for the identified fixed dispense time. WP3_Birmingham; 16 Jan2014; John Wilson

WP3_Birmingham; 16 Jan2014; John Wilson S Pyatt Glue dispense testing system A specially designed glue testing system is used for qualifying glues. This consists of a jig designed to hold three glass slides, one slide for a pre-test glue purge and two glass slides for dispensing test dots. The method is as follows: Weigh the glass slide. Dispense test dots on to the test slides. Weigh glass slide to determine mass of glue dispensed. WP3_Birmingham; 16 Jan2014; John Wilson

WP3_Birmingham; 16 Jan2014; John Wilson S Pyatt Loctite 3525 Dispense time step test, 5 dots per slide. Increments are in 0.05 and 0.1 seconds. Target mass is 2.0 mg. 1 bar pressure. 0.6mm distance. Blue 22 gauge needle. Target dispense time is around 1.80 seconds. WP3_Birmingham; 16 Jan2014; John Wilson

WP3_Birmingham; 16 Jan2014; John Wilson S Pyatt Loctite 3525 Variation in weight for fixed dispense times Average 1.90 Std Dev 0.29 Average 2.32 Std Dev 0.31 Average 2.27 Std Dev 0.23 WP3_Birmingham; 16 Jan2014; John Wilson

WP3_Birmingham; 16 Jan2014; John Wilson S Pyatt Conclusions All three glues can be dispensed with the Dotmaster but the Dymax 3013 looks the least suitable. The trial demonstrates all three glues require different parameters which is most likely caused by the differences in viscosity. The trail also demonstrates the variations in accuracy of the Dima Dotmaster glue dispensing system. This variation could be used as a guide for buying an up to date dispensing system. Newer dispensing systems may be more accurate. WP3_Birmingham; 16 Jan2014; John Wilson

WP3_Birmingham; 16 Jan2014; John Wilson Next Steps 250nm With “end of line” panels, gratefully received from Tony , we have learned a lot: measuring, adjusting jigs to meet 80μm glue thickness, remeasuring etc. But shear tests of ASIC-hybrid glue bonds will not be conclusive due to inferior quality of panels. 130nm Look forward to receiving soon. repeat tests to compare room temp and heated plate curing. With 250nm, potential to glue/cure 8 hybrids per day with heated plate curing (cf 2 hybrids per day at room temp). Can the same rate be achieved with 130nm? If so, is ASIC-hybrid glue bond strength with elevated temp cure sufficient? WP3_Birmingham; 16 Jan2014; John Wilson