Truss Heel Heights and Energy Code Requirements

Slides:



Advertisements
Similar presentations
BUILDING ENERGY CODES UNIVERSITYwww.energycodes.gov/BECU 1 BUILDING ENERGY CODES UNIVERSITY ANSI/ASHRAE/IES Standard Scope and Application April.
Advertisements

Presents 2012 Revisions to the NC Energy Code For Residential Building started after March 1, 2012.
ENERGY CONSERVATION: HOME WRAP, INSULATION, AND STOPPING AIR LEAKS.
EarthCraft: Insulating Strategies Energy Efficient Insulation Systems by Church Hill Homes.
eQuest Quick Energy Simulation Tool
Carpentry Skilled Trades Ceiling and Roof Framing The most commonly used types of residential roof and ceiling construction are: Joist and Rafter.
Walls of Structure Decreasing the Amount of Heat Exchange.
“Do not take anyone’s advice as to how this building should be assembled.”
Energy Square 1111 “O” Street, Suite 223 Lincoln, Nebraska Website: Phone:
PERMITS & INSPECTIONS DEPARTMENT 2003 INTERNATIONAL RESIDENTIAL CODE IRC.
C A L I F O R N I A E N E R G Y C O M M I S S I O N Cool Roofs in California’s Title 24 Building Energy Efficiency Code 2005 Update and 2008 Preview CRRC.
Energy Rating Index Performance Path Speaker Name Speaker Affiliation.
Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010.
This 12 part PowerPoint series is taken directly from Energy Savers Booklet, Tips on Saving Energy & Money at Home, U.S. Department of Energy.
THE IMPACT OF STATE LEVEL BUILDING CODES ON RESIDENTIAL ELECTRICITY CONSUMPTION Anin Aroonruengsawat UC Berkeley, ARE Maximilian Auffhammer UC Berkeley,
The Energy Star Home Drew Tepper. Overview What is an energy star home? What is an energy star home? New Homes New Homes Existing Homes Existing Homes.
Chapter 2: Energy Ratings and Economics To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Chapter 4: Air Leakage Control: Materials and Techniques
Unit A3-12 Insulating Agricultural Structures Problem Area 3 Construction Systems.
Copyright 2008, International Code Council 2012 IECC ® for SERBCA Based on the 2012 International Energy Conservation Code.
What You Need to Know About EPA’s ENERGY STAR Certified Homes Program Learn more at energystar.gov 1.
Roof Types, Components & Terminology
Flash and FOIL® Frame Wall Insulation. Module 1 Masonry Wall Insulation Hybrid Spray Foam and Reflective Insulation System – Fi-Foil® Company Introduces…
MECHANICAL ASPECTS OF MICHIGAN UNIFORM ENERGY CODE MIAM DOHERTY INN CLAIRE, MICHIGAN MARK RILEY.
SEEA Presentation to SEES March 2006 SEEA Presentation to SEES February 2006 SOUTHEAST ENERGY EFFICIENCY ALLIANCE.
What You Need to Know About EPA’s ENERGY STAR Certified Homes Program Learn more at energystar.gov 1.
What is Thermal Bridging? A reduction of the effectiveness of insulation to reduce conductive heat flow through the building envelope otherwise know as.
Part 2: Buildings as a System Lee F. Ball Jr., PhD
Energy Performance and Moisture Control of Ceilings and Roofs 1.
Attending the ICC Conference in Detroit this September or know someone who is?
EDT Elevations1 Weekend Cabin Retreat Project Elevations Sacramento City College EDT 300/ENGR 306.
PowerPoint ® Presentation Unit 52 Thermal Insulation and Other Insulating Methods Thermal Insulation Exterior Insulation and Finish Systems (EIFS) Roof.
1 Energy Efficient Housing. 2 Why construct energy efficient structures? Bottom Line !!! Money It may save up to 60% of the cost to heat/cool the structure.
EDT Cabin Design Project - Elevations1 Weekend Cabin Retreat Project Elevations Sacramento City College EDT 300 Kenneth Fitzpatrick, P.E.
Chapter 28 Structural Components of Framed Construction.
Sprinkler Loads on Trusses
MWFRS Method v/s Components and Cladding Method for Truss Uplift Connection Design for Wind Overview.
Fire Resistance Rated Truss Assemblies Educational Overview.
Position Statement on Sealed Truss Placement Diagrams for the State of California (including Los Angeles) Overview.
Heel Blocking Requirements and Capacity Analysis
Hillsborough Building & Planning. Green Building 101  Efficiency of buildings and responsible use of water, and construction materials  Reducing building.
Sprinkler Loads on Trusses Educational Presentation.
Stretch Code Informational Session March 16, 2011.
Overdriven Nails in Structural Sheathings Overview.
Energy Codes and the Building Envelope
Floor Vibration: Causes and Control Methods
Competency: Draw roof plans
FRT Lumber Use in Type III-A Buildings
Bottom Chord Live Load Concurrency and Truss Design
Use of Resilient Channel or Hat Channel to Meet the Lateral Restraint/Bracing Requirements of the Bottom Chords of MPCWT Floor Systems Overview Revised.
Home Energy Savings Program Wyoming
Position Statement on Sealed Truss Placement Diagrams for the State of Texas Overview Revised 3/23/2017.
Use of Cantilevered Sill Plates with MPCWT to Align with Varying Thicknesses of Exterior Sheathing Overview Revised 3/22/2017.
Product Evaluation and Indemnification
Long Span Truss Installation
Competency: Draw roof plans
Impact of C&C loads due to ASCE/SEI 7-16
Prescriptive R-values, U-factor equivalents, and total ua analysis
Wood Structures Topic 8 Quality Workmanship
Overdriven Nails in Structural Sheathings
Energy Codes and the Building Envelope
Thermal Bypass Checklist Round-Table
Position Statement on Sealed Truss Placement Diagrams for the 2012 or 2015 International Residential Code Overview Revised 3/23/2017.
Competency: Draw roof plans
Floor Truss Ribbon Board Load Path
Truss Submittal Packages and Jobsite Packages
Wall and Ceiling Construction
Competency: Draw roof plans
BUREAU OF STANDARDS JAMAICA
Building standards Mr. Da Silva.
Presentation transcript:

Truss Heel Heights and Energy Code Requirements Overview Revised 2/17/2017

Copyright © 2017 Structural Building Components Association. SBCA has been the voice of the structural building components industry since 1983, providing educational programs and technical information, disseminating industry news, and facilitating networking opportunities for manufacturers of roof trusses, wall panels and floor trusses. SBCA endeavors to expand component manufacturers’ market share and enhance the professionalism of the component manufacturing industry. Copyright © 2017 Structural Building Components Association.

Introduction In recent years, there has been increased interest in improving the energy efficiency of buildings throughout the United States. Tax credits are available for homeowners who purchase energy efficient upgrades including insulation, high efficiency windows and doors, heating and cooling equipment and caulking. Out of all these recent efforts, what may have the greatest long term effect are improvements to energy efficiency requirements in the building codes.

Introduction Energy use has decreased significantly as a result of the American Clean Energy and Security Act (ACES) of 2009 which mandated overall energy savings targets to be met by the model building codes. This presentation will address the requirements of the 2009, 2012 and 2015 International Residential Code (IRC) and International Energy Conservation Code (IECC) as they impact ceiling insulation and truss heel heights. Source: ACEEE

Key Definitions Building Designer – Owner of the Building or the Per­son that contracts with the Owner for the design of the Building Structural System and/or who is responsible for the preparation of the Construction Documents. When mandated by the Legal Requirements, the Building De­signer shall be a Registered Design Professional. Standard Truss – Any construction that does not permit the roof/ceiling insulation to achieve the required R-value over the exterior walls.

Key Definitions Truss Heel Height – The vertical depth of the truss at the outside face of the bearing. Standard Heel – Typical truss heel height is about 4". Raised (Energy) Heel – Typical truss heel height is about 12" but may be designed to most any height per the Building Designer specification.

Background Chapter 11 of the IRC deals with energy efficiency and is closely coordinated with Chapter 4 of the IECC (section numbers in parenthesis). There have been a few section number changes between versions, as well as some revisions for clarity and some increases to R-value requirements. Section/Table Reference 2006 2009 2012 2015 Table: Insulation and Fenestration Requirements by Component N1102.1 (402.1.1) N1102.1.1 (R402.1.1) N1102.1.2 (R402.1.2) Section: Ceilings with attic spaces N1102.2.1 (402.2.1) N1102.2.2 (R402.2.2) N1102.2.1 (R402.2.1)

Background The following table illustrates some general insulation thicknesses to meet the 3 ceiling R-Value requirements (R-Values for similar products can vary greatly among manufacturers): Insulation R-Value per inch R-30 R-38 R-49 Fiberglass blown 2.2 - 4.3 9″-10″ 12″-14″ 16″-18″ Fiberglass batt 3.1 - 3.4 Mineral wool blown 3.1 - 4.0 Cellulose blown 3.2 - 3.7 8″-9″ 10″-12″ 14″-16″ Open cell Spray Foam 3.5 - 3.6 11″-12″ 14″ Closed cell Spray Foam 6.0 - 6.5 5″ 6″-7″

Background An air space for ventilation above the insulation is required in vented attics, which adds 1-2″ of additional height at the eaves. Questions have been asked about the proper application of ceiling R-Value requirements when the roof framing may limit the height of the insulation at the outside face of the building.

Background The ultimate aim is to answer the following questions: What happens at the outside of the wall where the vertical depth of the roof framing is typically less than the required depth of insulation? Does the depth of the framing need to increase? Does the building designer need to modify the profile of the building to accommodate this increased framing depth?

Analysis There is also confusion as to the required height of the roof framing above the wall top plate at the eaves. Section N1102.2.1 of the 2006 through 2015 IRC allows substitutions when full height insulation extends over the wall top plate at the eaves. R-30 may be used in place of R-38 R-38 may be used in place of R-49 Note that this substitution applies only when R-values are used. If U-factors or the total UA alternative is used, the reduced thickness must be accounted for in the calculations.

Analysis Insulation installed in a typical roof assembly is full height in the center of the assembly and tapers to less than full height at the edges. This taper is caused by, and is proportional to the slope of the roof. Because of the lower insulation depth, the R-value will be less at the truss heels than the rest of the span. Compression Zone

Analysis Compression Zone The ceiling R-value requirement assumes standard framing and thus accounts for a certain level of reduced thickness. This area of reduced thickness is referred to in the codes as “compression”, although the insulation itself may or may not be compressed. When insulation can be installed full thickness over the plate line of the exterior wall, the code will allow a lower level of insulation throughout. Higher level of insulation throughout No Compression Zone Lower level of insulation throughout

Analysis This allowance recognizes that a partial thermal "bypass" has been made more efficient by using insulation with the full R-value at the eaves. The full insulation R-value is sometimes achieved by what is termed an "energy heel truss" or "advanced framing." No Compression Zone

Analysis Note that this reduction can also apply to conditioned attics if the insulation is installed directly under the roof deck, rather than on the attic floor The insulation would be permitted to meet the reduced R-value, if the full R-value is met all the way over the exterior walls. This assumes that the attic space beneath the insulation is not vented.

Conclusion It is important to recognize that code prescriptive R-value requirements for ceiling insulation take into account the lower depth of insulation found in standard heel roof framing. The ceiling R-values in the IRC, therefore, are not intended to be the minimum R-values for the attic space directly above an exterior wall but rather the rated R-value for the majority of the attic space.

Conclusion The exception in Section N1102.2.1, allowing R-30 where R-38 is required or R-38 where R-49 is required is a trade-off to the initial requirement. Note that there is no similar exception given for the R-30 requirement in Climate Zone 1 to reduce the R-Value requirement if 100% of the ceiling area can be covered with a lesser R-Value.

Conclusion With this information in mind, the answers to the questions posed earlier are clear: What happens at the outside of the wall where the vertical depth of the roof framing is typically less than the required depth of insulation? Nothing. The amount of insulation R-value over the remaining area has been increased to account for this very situation. Does the depth of the framing need to increase? No, not as long as the required insulation R-value is covering most of the ceiling area. Does the building designer need to modify the profile of the building to accommodate this increased framing depth? No, as there is no need for increased framing depth. “Component Performance” versus the “Prescriptive” approach for the entire building is also a means to achieve objectives for minimal insulation levels over exterior walls. When all of the components of the building envelope come into play, it expands the opportunity for successful tradeoffs.

References International Energy Conservation Code, 2009, 2012, and 2015 by the International Code Council International Residential Code, 2006, 2009, 2012 and 2015, by the International Code Council TPI 1 – 2007, by the Truss Plate Institute BCSI (Building Component Safety Information), June 2011 by Structural Building Components Association (SBCA) and Truss Plate Institute (TPI)