Impact of High-Efficiency Filtration Combined with High Ventilation Rates on Indoor Particle Concentrations and Energy Usage in Office Buildings National.

Slides:



Advertisements
Similar presentations
IAQ, FILTRATION AND THE CONSUMER MARKET Matthew Klein, PE-ME, MBA Indoor Air Quality Solutions, Inc.
Advertisements

To Flush or Not to Flush Compliance with LEED-NC ® 2.2 EQ 3.1 & 3.2 Tom Hanlon LEED AP, NEBB Cx.
PowerPoint ® Presentation Chapter 15 Troubleshooting and Mitigating IAQ Problems Troubleshooting and Mitigating IAQ Problems Overview of Non-IAQ Problems.
Controlling the amount of ventilation to a space based on demand Reset based on occupancy: Use carbon dioxide sensors to track space CO2 levels and raise.
Bringing the Outside In: Ventilation for Your Health Henry Slack U.S. Environmental Protection Agency Region 4.
The Role of Controls for Indoor Air Quality Kent W. Peterson, PE, Fellow ASHRAE P2S Engineering, Inc. Mid Columbia ASHRAE Chapter.
Indoor Air Quality (IAQ) March 2009 UCOP Safety Meeting.
The Portland Street Building Back to “Select a building” Back to “Select a building” NatVent Presentation of the building Presentation of the building.
Timber Research Centre Michael Anderson– Mohamed Farid Pablo Prallong – Lewis Macleod Ross Turbet & Group A 26/04/20054 th Presentation.
PowerPoint ® Presentation Chapter 5 Handheld Meter Testing IAQ Complaints Measurement and Testing Air Properties Handheld Meter Testing for Contaminants.
BRE Energy Efficient Office of the Future
Ventilation Effectiveness & Indoor Air Quality Douglas Spratt February 2001.
1 Transportation, Air Pollution, Climate The Road Ahead in Asia August 19, 2014 Michael P. Walsh International Consultant Founding Chairman Board of Directors,
The Air We Breathe - Indoor Air Quality and Natural Ventilation Dr Yuguo Li Associate Professor Department of Mechanical Engineering The University of.
Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015.
SUSTAINABILITY ANALYSIS OF RESIDENTIAL BUILDINGS Ashok Kumar Abhilash Vijayan Department of Civil Engineering.
WESTINGHOUSE ELECTRIC NUCLEAR ENGINEERING HEADQUARTERS DANIEL AUGHENBAUGH - MECHANICAL OPTION Westinghouse Nuclear Engineering Headquarters Daniel Aughenbaugh.
Indoor Firing Ranges Training Education Recommended Practices.
The Velux Building NatVent Presentation of the building Presentation of the building The design issue The design issue The building concept The building.
High Performance Buildings Research & Implementation Center (HiPer BRIC) December 21, 2007 Indoor Environment in Commercial Buildings Connection to reducing.
Data Centers - They’re Back… E SOURCE Forum September, 2007 William Tschudi
High Performance Building Congressional Caucus Coalition December 14, 2010 Thomas H. Phoenix, P.E. LEED AP.
Impact of Temperature on Occupants: Theory vs. Reality
Importance of Lightning NO for Regional Air Quality Modeling Thomas E. Pierce/NOAA Atmospheric Modeling Division National Exposure Research Laboratory.
The EWZ building Presentation of the building Presentation of the building The design issue The design issue The building concept The building concept.
1 Scripps Inst. of Oceanography University of California at San Diego Oakland, California, October 18, 2013 V. Ramanathan, University of California, San.
Grocery VSD Measure Deemed Savings Reid Hart, PE & Ken Anderson September 28, 2010.
Final Projects Grading criteria is posted on the course website Preliminary results are due Next Tuesday Final Project delivery on Monday Dec. 7 th –Final.
V3 vs. v4 New Protocols for LEED Tommy Linstroth, Principal.
ICT- PRACTICAL. TYPES OF POLLUTION WATER POLLUTION NOISE POLLUTION AIR POLLUTION SOIL POLLUTION.
Formaldehyde Emission Modeling in Manufactured Homes Jacqueline Bayer 1, Dr. Patrick Gurian 2, and Dr. Jin Wen 2 1 BS/MS Student, Dept. of Civil, Architectural,
Human Impact on the Atmosphere Human Impact on the Atmosphere Chapters 18 and 19 Living in the Environment, 11 th Edition, Miller Advanced Placement Environmental.
Data Center Energy Efficiency SC07 Birds of a Feather November, 2007 William Tschudi
Free Air Cooling for Data Centres
Air Pollution and Public Health in India
Testing & Comparing Stoves
Impact of High Efficiency Filtration Combined with High Ventilation Rates on Indoor Particle Concentrations and Energy Usage in Office Buildings Michael.
Air Filtration and Indoor Air Quality Panel Discussion
Particulate Matter Sources, Health Effects, and Control Strategies
PARTICULATE MATTER REMOVAL THROUGH THE USE OF VENTILATION SYSTEM, A CASE STUDY IN UNIVERSITY CLASSROOMS Wannawit TAEMTHONG, Watchara SIRIKULYANONA King.
William Fisk and Rengie Chan Indoor Environment Group
Residential HVAC Filtration What Does it Do?
Update on USGBC LEED and Air Filtration NAFA 2008 Annual Convention San Francisco, CA September 19, 2008 by Francis (Bud) J. Offermann PE CIH Indoor.
The Indoor Air Quality in a Multi-garage
XXXXXXXX Xxxxx XXXXX Xxxxxx XXXXXX Xxxxxx
ASHRAE’s 62.2 Residential Ventilation Standard Proposed Changes
EXPOSURE OF CHILDREN TO ULTRAFINE PARTICLES AROUND AN URBAN INTERSECTION S Kaur, M J Nieuwenhuijsen & R Colvile Environmental Processes & Systems Research.
NAFA Guide To Air Filtration
Data Center Research Roadmap
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
Filtration and Coil Fouling
Sustainability and Life Cycle Costing of Air Filtration
In-Situ Filter Testing
Better Student Performance So, What Are We Waiting For?
Lecture Objectives Learn about particle dynamics modeling
Residential Indoor Air Quality
Chapter 3B: INDOOR AIR QUALITY
VENTILATION ASPECTS OF INDOOR AIR QUALITY
OZONE INTERACTIONS WITH HVAC FILTERS
Student Activities Centralized Training
Variability in 52.2 Testing
Bart Ostro, Chief Air Pollution Epidemiology Unit
Technology in Architecture
Chapter 3B: INDOOR AIR QUALITY
Property of National Air Filtration Association
Chapter 3B: INDOOR AIR QUALITY
Air Quality and Health Dr Liz Robin Director of Public Health
Dental Office Hours Air Quality By Olivia Potthoff and Abigail Shaffer
Presentation transcript:

Impact of High-Efficiency Filtration Combined with High Ventilation Rates on Indoor Particle Concentrations and Energy Usage in Office Buildings National Air Filtration Association (NAFA) Friday, August 28, 2015 Michael S. Waring Associate Professor Director of Architectural Engineering Program Civil, Architectural and Environmental Engineering at Drexel University Indoor Environment Research Group (http://www.indoor-envi.com/) Drexel Air Resources Research Laboratory (DARRL) Building Science & Engineering Group (BSEG) msw59@drexel.edu

Introduction Motivation Introduce upcoming NAFA + ASHRAE funded research project Examine the impact of using high efficiency filters at the same time as using high ventilation rates (VRs) in offices Why do this work? ASHRAE minimum for VRs in offices is ~17 CFM/person Yet, increased VRs, particularly in offices, may have many positive effects on occupant wellbeing Lower infection risk, less Sick Building Syndrome (SBS), reduced absenteeism, better productivity and decision making However, higher VRs will increase particulate matter (PM) indoors PM exposure = reduced health! Impact of High-Efficiency Filtration + High Ventilation Rates in Offices Slide 2/11

Introduction Motivation E.g. Impact of CO2 exposure on human decision making: Experiments: Mock office Clean air CO2 added to: 600, 1000, and 2500 ppm Aptitude testing Satish et al. (2014) EHP Impact of High-Efficiency Filtration + High Ventilation Rates in Offices Slide 3/11

Methodology Filtration impact field and modeling study Conduct field experiments to demonstrate ability of filters of different efficiencies to mitigate indoor PM concentrations with varying VRs Third floor of Drexel University campus building Measure in ambient air, supply air, and return air: Fine particles (TSI DustTrak DRX 8533) Ozone (2B Technologies 205) Nitrogen oxides (2B Technologies 405) Carbon dioxide (PP Systems, WMA-4) Fan energy determined with installed sub-meters Other energy used with building automation system (BAS) reporting Model impacts for 14 cities in U.S. climate zones Impact of High-Efficiency Filtration + High Ventilation Rates in Offices Slide 4/11

Methodology Filtration impact field study Conduct three weeks of testing, at three times in one year: 3 weeks in Winter 3 weeks in Spring 3 weeks in Summer At least 63 days of testing Week 1 Week 2 Week 3 MERV 8 MERV 11 MERV 15 Day 1 2 3 4 5 6 7 VR High Low High Med High Low High Impact of High-Efficiency Filtration + High Ventilation Rates in Offices Slide 5/11

Methodology Filtration impact field study Air handling unit (AHU) and sampling schematic: Impact of High-Efficiency Filtration + High Ventilation Rates in Offices Slide 6/11

Methodology Filtration impact field study E.g., PM2.5 sampling at three locations: Impact of High-Efficiency Filtration + High Ventilation Rates in Offices Slide 7/11

Methodology Filtration impact field study E.g., PM2.5 indoor/outdoor (I/O) ratios as a function of OA/SA: 1.0 MERV 8 pre-filter + MERV 11 V-filter, Supply flow = ~5500 cfm 0.8 I/O ratio 0.6 0.4 0.2 0.3 0.4 0.5 0.6 Fraction of Outdoor Air (OA) / Supply Air (SA) Impact of High-Efficiency Filtration + High Ventilation Rates in Offices Slide 8/11

Future Impacts Deliverables Literature review on the impact of high efficiency filtration at mitigating exposure to indoor PM of outdoor origin at different VR conditions Description of Quality Control/Quality Assurance (QA/QC) Full time series of all measured data over 63 days of experiments Measured I/O ratios at the different VRs and filtration efficiencies Results of the modeling study over the 14 U.S. cities Cost-benefit analysis of using higher efficiency filters in terms of filter cost and fan energy requirements for a typical year of operation, placed in context of energy needed to supply higher VR Impact of High-Efficiency Filtration + High Ventilation Rates in Offices Slide 9/11

Future Impacts Benefit to NAFA and society Demonstration of ability to control PM, even at high VRs Improve work performance and health in offices by using higher VRs, with least negative side effects Contextualization of energy needed for PM control at high VRs Influence building design/operation of healthy indoor spaces Advance NAFA mission to: “educate end-users about the importance of air filtration” Impact of High-Efficiency Filtration + High Ventilation Rates in Offices Slide 10/11

Questions? Acknowledgments Special thanks to: National Air Filtration Association (NAFA) American Society for Heating, Refrigeration, and Air-conditioning Engineers (ASHRAE), New Investigator Award Questions? Impact of High-Efficiency Filtration + High Ventilation Rates in Offices Slide 11/11