Jim Vermeulen MSA Territory Manager

Slides:



Advertisements
Similar presentations
Gas Detection Instruments
Advertisements

Monitoring Equipment and Detection Devices Chapter 14.
OFFLINE COMPOSITION MEASURING SENSORS
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
SOLARIS 3-GAS METER Complete operation of Solaris multi-gas meter can be found on the LAFD Ethernet.
[Compact. Durable. Ingenious.]. Extra bright, highly visible LEDs Fits comfortably in the hand Separate Info display Extremely robust construction High.
DP-IR Detecto-Pak Infrared
(PLEASE SWITCH TO THE SLIDE SHOW MODE)
Hazmat Industry Technician. Types of Equipment Monitoring equipment Detection devices Air sampling systems.
Luminescence Dissolved Oxygen
THS3000 Product Introduction Market Dynamics  Customers require more flexible solutions  Many test solutions are driven by both measurement needs.
Personal Surveyor 200 (PS200) Series
Company Confidential © 2005 All Rights Reserved. What is it? State-of-the-art: microprocessor-based, wall-mount gas monitor Easy installation and operation:
January 12, 2013 G460 PID sensor performance and maintenance Slide 1 G460 PID sensor performance and maintenance GfG Instrumentation, Inc Oak Valley.
Gas Chromatography in the detection of Volatile Organic Compounds.
THE LATEST DETECTION TOOLS FOR LEAK / ODOR RESPONSE, CARBON MONOXIDE AND CONFINED SPACE ENTRY Paul D. Wehnert Vice President – Sales & Marketing Heath.
Basic Air Monitoring Concepts And Use Of The Altair 4 Gas Meter
MSA - ALTAIR 4X Gas Meter.
4135 Bluebonnet Dr. Stafford, TX
Air Monitoring Presented By: Etech Environmental & Safety Solutions, Inc.
ITX 4-Gas Detector Quick Reference Guide. Case:Type 304 Stainless Steel,.024" (.61mm) thick Dimensions:4.75" X 3.2" X 1.68" (121mm X 81mm X 43mm) Weight:18.5.
Altair® 5X MultiGas Detector Altair® 5X MultiGas Detector The ALTAIR 5X MultiGas Detector is to be used when performing a hazard assessment.
Ultima® X Series Gas Monitors
ALTAIR ® 5X Multigas Detector It’s what’s inside that counts!
Environmental Investigators Lonnie Gilley Robin Pugh.
ALTAIR ® 4X Multigas Detector It’s what’s inside that counts!
MULTI-GAS MONITOR FOR CONFINED SPACE APPLICATIONS
Altair ® 5 & 5IR Multigas Detectors IR and toxic gases added!
HazMat Technician Mod 1 Unit 2 Slide 1 Ohio Hazmat & WMD Technician Module 1 Unit 2 Field Survey Instruments.
WELCOME TO Gas Tester Training O2, LEL Monitoring
Chapter 8 Solutions, Acids & Bases
Tools Available for Real-Time Exposure Assessment Phil Smith, PhD, CIH CDR MSC, USN
New type of Add-on Monitor for Continuous PAH Nano Particles Surface SOOT by Hans Grimm International Sales Meeting 2008.
Florida Operations Level Hazardous Materials Training Unit 5.5 MISSION SPECIFIC: Air Monitoring and Sampling.
Reducing risk with Exposure Monitoring Equipment.
Welcome Acklands-Grainger April 16, Technology Applications Advantage: VX500.
MX6 iBrid Multi-Gas Monitor
© 2007 Multigas Detector Reliability in a small package.
PID Gas Meter/Detector. Introduction Air monitoring data is useful for: *Assessing the health risks to the public and response workers. *Selecting personal.
It’s a GasBadge…
Chapter 13 - Analytical Instrumentation 1 Chapter 14 Analytical Instrumentation.
ORION ®plus IR Detector [ Compact. Durable. Ingenious. ] When you need more versatility….
© 2006 MSA VaporLab™ 700 Gas Analyzer. © 2006 MSA Product Description  Rack mount, turn-key gas analyzer  Analyzes a complex matrix for trace quantities.
1 Setting Action Levels and Controlling exposure with Air Monitoring A review...
Continuous Benzene-Specific Monitoring Werner R. Haag & Stephen Powell Ion Science IPEC Denver 19 November 2015.
Free Residual Chlorine Measurement
© MSA 2015 Because every life has a purpose… Altair 5X with PID and Xtirpa Fall Protection Solutions 11/9/15 – Airgas Joe Gormley / Andy DeLair– MSA Safety.
Misuse of Combustible Gas Meters Supervisor Training 1/11/08.
GmbH Specialist hotel application ComplianceCommercial refrigeration Industrial refrigeration Light Industrial Gas Detection MGS-550 Product Portfolio.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
Atmospheric Monitoring. ATMOSPHERIC MONITORING INSTRUCTIONAL GOAL The participant will understand the need for atmospheric monitoring and the types, uses,
How to ensure Safety? Calibration vs Functional (Bump)Test Differentiate between calibration and functional (bump) test functional test –the sensors.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
By, T.Aathmanesan.. Everybody knows about pollution, in fact is a part of our lives today. Definition : “Presence of contamination in the environment.
1 1.
Agenda What is MicroRAE? Value Proposition Markets & Applications
Microwave Plasma Discharge and Its Applications
IN SAMPLE PUMP INNOVATION
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
Bob Henderson, BS, MBA GFG Instrumentation Inc. Ann Arbor, MI
SKC IS PROUD TO INTRODUCE A NEW LOW FLOW SAMPLING PUMP
Gas Chromatography.
SKC IS PROUD TO PRESENT SAMPLE PUMPS FOR A NEW GENERATION
G450 and G460 battery pack maintenance
Ohio Hazmat & WMD Technician
FLAME SPECTROSCOPY The concentration of an element in a solution is determined by measuring the absorption, emission or fluorescence of electromagnetic.
Everyone is talking about
Automobile Emission Gas Analysis Solution
Dräger X-am 5000 / X-am 5600 VIDEO BASIC TRAINING
Detecting and measuring atmospheric hazards in underground mines
Presentation transcript:

Jim Vermeulen MSA Territory Manager ALTAIR® 5X with PID + Jim Vermeulen MSA Territory Manager

Introducing the ALTAIR 5X PID NEW Advanced PID sensor option 10.6eV 0-2000ppm Detect up to 6 gases simultaneously! Integrated pump for consistent flow Up to 100 feet sampling line Rechargeable Lithium-Ion Battery 13 Hour Run-time Easy to Use

ALTAIR 5X PID What is a VOC? Volatile organic compounds, or VOCs are organic chemical compounds whose composition makes it possible for them to evaporate under normal indoor atmospheric conditions of temperature and pressure* Many compounds are toxic at very low levels…well before they near combustible levels Example: Benzene Occupational carcinogen (Toxic) & Combustible NIOSH Short-term exposure limit = 1 ppm LEL = 1.2% VOL or 12,000 ppm *Definition from United Stated EPA

ALTAIR 5X PID Common VOCs Solvents Paints Coatings Diesel Jet Fuel Gasoline Acetone Ethanol Benzene Butadiene Hexane Toluene Xylene MEK Ethylene Oxide Many Others

ALTAIR 5X PID Detection Technology Photoionization Detector Photo = Light (UV Light for PID sensor) Ionization = Energize molecules to lose electrons Detects flow of electrons More electrons = Higher concentration of gas Broad Spectrum – Does not differentiate gases Indicates the presence of many compounds Does not determine what the compound is Only works for compounds with lower Ionization Potential (IP) than PID lamp energy

ALTAIR 5X PID Detection Technology VOC molecule absorbs energy from the PID lamp in the ionization chamber VOC molecule is “excited” and loses an electron (e-) while becoming positively charged The VOC is now ionized and the detector measures the flow of electrons Sensor readings are directly proportional to number of VOC molecules ionized AIR VOC PID Lamp UV Light e- Anode Cathode Note: Only the VOC is ionized, Air is not ionized

ALTAIR 5X PID Detection Technology Compounds have different ionization energies Lamp energy must be higher than IP substance Phenol CAN be detected by 10.6eV lamp Methane can NOT be detected by 10.6eV lamp 10.6eV PID Sensor 7 Phenol 8.49 Methane 12.61 16 Lower Energy Required Higher Energy Required Ionization Energy eV

ALTAIR 5X PID Easy to Use Interface Virtually Identical to current 5X VOC page for easy access to Reference Factors Can be password protected

ALTAIR 5X PID Reference Factors For Manual Correction Set ALTAIR 5X PID to Default Isobutylene Take reading of known environment (ie – Hexane) Hexane RF = 4.5 32.0PPM X 4.5 = 144PPM Hexane Reference Factor Instrument Reading Actual Reading Hexane

ALTAIR 5X Advanced Features Confidence signal Indicates proper operation every 30 seconds Green blinking Safe LED Vibrating pulse Confidence beep End-of-sensor life warning Provides 4-6 week notice when the sensor will fail Warning shown on-screen by flashing sensor life indicator Warning icon displayed until the sensor is replaced and/or successfully calibrated

ALTAIR 5X PID Sensor Options XCell® Sensors Ex (COMB) 0-100% LEL Ex-M 0-100% LEL Ex-H 0-100% LEL O2 0-30% Vol CO 0-2000 ppm CO H2 Res 0-2000 ppm CO HC 0-9999 ppm H2S 0-200 ppm H2S LC 0-100 ppm SO2 0-20.0 ppm NO2 0-50.0 ppm Cl2 0-20.0 ppm NH3 0-100 ppm 20mm Exotic Sensors HCN 0-30 ppm PH3 0-5 ppm ClO2 0-1 ppm NO 0-100 ppm NO2 0-20 ppm PID Sensor 10.6eV 0-2000 ppm (125 Response Factors Built-In)

The MSA XCell Advantage Multiple patented technologies for: Extended Sensor Life ≥ 4 Year Life on most XCell Sensors Standard 3 year warranty on most XCell Sensors XCell-erated response/clear time, bump test >200% faster response time than industry average Longer sensor life and fast response 40% less calibration gas used per minute than industry average

ALTAIR 5X Real-Time Awareness Enabled Bluetooth® Wireless Standard* Connectivity with approved Android device(s) Enhanced functionality with MSA Application+ Real-Time Readings/Alarms SMS/Text Messages of Alarms Instrument Configuration Timed sampling mode Additional partner solutions available, SONIM & BCOM *Standard for cCSAus, UL, ATEX, & IEC approvals *Images are simulated and may not represent final product

ALTAIR 5X Real-Time Awareness Enabled Real-Time Detection Field User Supervisor *Images are simulated and may not represent final product

ALTAIR 5X Enhanced Ease-of-Use Instrument Settings *Images are simulated and may not represent final product

ALTAIR 5X PID Use Existing 5X Accessories ALTAIR 5X PID compatible with GX2® Galaxy Test stand GX2 Galaxy Charger Vehicle Charger Sample Lines & Wands MSA Link/Link Pro

Shameless Plug- Look at the Comfort!!!

Questions?