Presentation is loading. Please wait.

Presentation is loading. Please wait.

ALTAIR ® 4X Multigas Detector It’s what’s inside that counts!

Similar presentations


Presentation on theme: "ALTAIR ® 4X Multigas Detector It’s what’s inside that counts!"— Presentation transcript:

1 ALTAIR ® 4X Multigas Detector It’s what’s inside that counts!

2 Our Vision of Safety Built on Durability – Based on tough Altair 4 Multigas Detector Powered by Performance – New High Performance XCell ™ Sensors

3 XCell Technology  Typical life >= 4 Years – 60% longer sensor life than the industry average – Standard 3 year warranty  XCell-erated response time, clear time, bump test – 38% faster response time than the industry average – Typical <= 15 seconds  Typical cost of ownership savings > 50% – Longer sensor life and fast response – 50% less calibration gas used per minute than industry average  Embedded microelectronics elevate performance – Each sensor has a microprocessor and digital output

4 Application Specific Integrated Circuit (ASIC)  Industry 1 st ! Every XCell Sensor has an embedded ASIC! – Microprocessor, memory, and all circuitry to drive the sensor – Digital output  Way beyond a “Smart Sensor” – Competitor’s “Smart Sensors” have a passive memory chip to store gas type, serial number, initial sensor settings, etc…. – The MSA ASIC drives the sensor, actively compensates the output, and coverts it into a digital signal.  Benefit – Higher performing sensors with greater stability

5 XCell O2 Sensor Life  Most Other O2 Sensors (Typical Life <= 2 years) – Use a consumable chemical reaction – Filled with lead which is converted to lead oxide – Sensor dies as lead is depleted (limited shelf life)  XCell O2 Sensor (Typical Life >= 4 years) – Non-consuming chemical reaction (No lead) – O2 reduced to water and then oxidized back to O2 – Vastly increased shelf life

6 XCell Ex Sensor Life  Most Other LEL Sensors (Typical Life = 2 years) – End of life caused by slow poisoning Poisoned by silicon, sulphur, or lead containing compounds – End of life can also result from a large physical shock  XCell Ex Sensor (Typical Life = 4 years) – Two detectors double the active life of the sensor – Only one detector is catalytically active at a time – Metal alloy support rod added to increase durability

7 XCell CO/H2S Sensor Life  Most Other CO/H2S Sensors (Life = 2-3 years) – Chemical poisoning of the electrode material – Loss of sensitivity due to electrolyte drying out  XCell CO/H2S Sensor (Typical Life >= 4 years) – Increased active sites on electrodes Increase sensitivity Reduce the effects of poisoning – Robust carbon filter to protect the CO electrode – Expansion electrolyte well minimizes drying effect

8 Response Times Significantly Faster Than the Competition!  Span Calibration: 60 sec  Bump Test: < 15 sec  Combustible sensor t90 <10 seconds (Methane) t90 <15 seconds (Pentane)  Oxygen sensor t90 < 10 seconds  CO sensor t90 < 15 seconds  H2S sensor t90 < 15 seconds

9 XCell Sensor  Designed and built by MSA – MSA IS Advancing Sensor Technology! – Our sensors are designed for OUR instruments! – We have the experts to support YOU!

10 Altair 4X Multigas Detector Personal 4-gas monitor – Detects O 2, H 2 S, CO, combustible gas – Rechargeable lithium-polymer battery Standard: – Event log – Full data log – Vibrating alarm – MotionAlert™ – InstantAlert™

11 Small Size  Small, unobtrusive, lightweight design  Easy to wear all day  Alarms visible from 360º  Fits in gloved hand  One-handed operation  Robust construction

12 Rugged Design  Over-molded case design  Built-in rubberized armor  Impact shock protection – Withstands 20-foot drop  Easy to grasp and hold  Sealed against water/dust ingress to IP67 – Third-party tested – Dunk it in a bucket!

13 Multiple Alarms  95+ dB horn typical  Multiple, alternating high-intensity alarm LEDs – On top and bottom of unit!  Vibrating alarm is standard on all models  InstantAlert ™ feature standard – Activates all alarms when desired  MotionAlert ™ feature standard – If no motion is detected for 30 seconds, alarm sounds to alert others – Ideal for confined space entry

14 Provides Confidence Confidence signal – Green blinking Safe LED – Vibrating pulse – Confidence beep every 30 sec. to ensure operation Can be turned off – Setup mode

15 Advanced Features  MSA exclusive MotionAlert™ feature – Indicates “man down”  MSA exclusive InstantAlert™ feature – Activates all alarms when desired  Most rugged instrument in its class – Withstands 20-foot drop  Agency certified IP67 rating – Water and dust tight √  Bump checkmark √ (24 hrs) – Displays successful test result

16 Advanced Features  Safe LED – Helps to ensures instrument’s proper operation  Missing sensor alarm – Helps to prevent errors after service  Password-protected setup mode – Controls unauthorized access  Event & data log – >500 events and >50 hours  MSA Link ™ Software-ready – Multi-language PC software to access records & change settings

17 Battery  Lithium-polymer technology  Virtually no memory effects  Holds charge better  Runs average of 24 hours – No need for multiple instruments during long shifts

18 Many Markets  Oil and gas  Chemical  Fire  Utilities  Agriculture  Construction  Steel  Water  Various industrial applications

19 Start-up  Performs diagnostic self-check – Display – 3 alarms – Sensor discovery  Displays: – Instrument name – Software version – Combustible gas type – Toxic units (ppm or mg/m 3 ) – Alarm set points (Low, High, STEL, TWA) Operation similar to that of Altair 4 & Solaris ® Multigas Detectors:

20 Start Up  Displays expected calibration gas concentrations  Shows current time and date  Indicates last successful cal. date  Indicates next cal. date (if activated)  Shows measurement countdown  Offers fresh air setup option  Defaults to measurement page

21 Pages  Measurement (default)  Bump  Peak readings  Minimum oxygen reading  STEL for toxics (if activated)  TWA for toxics (if activated)  Time  Date  MotionAlert ™ feature

22 Data Log  Event logging (500 events) – Gas and battery alarms – Calibration & bump records – Battery voltage – FAS, re-zero, calibration – Reset of TWA, STEL & Peak  Gas records(>50 hours) – Reading – Time and date – Peak, Min, Average – Temperature  Graphs & tables  Infrared-based MSA Link Software-compatible – Change instrument settings  Last successful calibration date

23 Setup  Password-protected access  Change: – Individual sensor channels – Combustible gas type – Auto calibration values – Calibration due on/off – Alarm set points – Low, High, STEL, TWA – Date – Time  Other settings through MSA Link Software

24 Calibration  Single-button auto cal-based – Access can be password-protected  Same Altair 4 & Solaris ® Detector calibration cylinders – 1.45% CH 4 – 60 ppm CO – 15% O 2 – 20 ppm H 2 S 10048280 (34L) 10045035 (58L)

25 Calibration 1. Press and hold ▲ button 2. Instrument prompts user to “Zero Cal?” 3. Press to accept & initiate zero function – Or press ▲ to cancel function 4. Unit will automatically zero sensors – Zero pass 5. Instrument prompts user to “Span Cal?” 6. Attach cal. cap & flow cal. gas to instrument 7. Press to accept & initiate span – Or press ▲ to cancel function 8. Unit automatically spans sensors

26 Accessories  Galaxy ® Automated Test System – Bump test and calibration – Record keeping  QuickCheck ® Station – Bump test only – Records activities  Charging cradle  Multi-Unit Charger – Up to 10 instruments  Universal pump probe

27 Low Maintenance Low level of end-user maintenance required:  Separate sensors  Sensor replacement kit  Filter, gasket, etc. kit  Front case with built-in filter  Battery and electronics  Most components available as replacement parts

28 Warranty Standard 3-year warranty – Sensors – Electronics – Battery Optional extended warranty – 1 year extra = 4 years total – Part of ATO!

29 Questions? Thanks!