How to Save Energy in Air Systems

Slides:



Advertisements
Similar presentations
Fans and Blowers.
Advertisements

1 Optimal Control of Chiller Condenser Sub-cooling, Compressor Speed, Tower Fan and Pump Speeds, and IGV Omer Qureshi, Hassan Javed & Peter Armstrong,
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
Coupling a Network HVAC Model to a Computational Fluid Dynamics Model Using Large Eddy Simulation Jason Floyd Hughes Associates, Inc Fire + Evacuation.
Fundamentals of Test & Balance for Engineers. Objectives Help the CxA understand and identify challenges of the TAB Agency Explain what can be accurately.
Variable Frequency Drives VFD Basics
Treatment of Mechanical Extract Ventilation and Balanced Whole House Mechanical Ventilation in DEAP Date October-2007.
H. Clay Moore & Associates Key Account Manager - Nuclear
Engineer Presentation
System Effects Presented by: Joe Brooks, AMCA International, Inc. AMCA International Technical Seminar 2009.
Presented by: John-John Fourie
Energy Efficient Motor Drive Systems. Motor Electricity Use Motors consume about 75% of all the electricity used by industry. Their popularity is a testament.
44 th Annual Conference & Technical Exhibition By Thomas Hartman, P.E. The Hartman Company Georgetown, Texas Sustainable Chilled Water.
A GLOBAL CORPORATION WITH EUROPEAN ORIGINS No. 1 in Europe 5 continents 40 countries 92 regional offices worldwide 630,000 units sold.
PLENUM FANS Terminology, History, Testing, Application and Trends AMCA International Technical Seminar 2009 Presented by: John Cermak, Acme Engineering.
Fans.
Static Pressure Control Loop The purpose of the static pressure control loop is to maintain an optimal static pressure in the ductwork. The control loop.
© American Standard Inc Fan Pressure Optimization The Trane Company.
Product Ratings and Performance Certifications Presented by: Tom Gustafson, Hartzell Fan, Inc. AMCA International Technical Seminar 2009.
Examples of Commissioning Cost Savings Commissioning for Sustained Building Performance September 29, 2011 Marriott Birmingham, AL.
Water piping design.
Understanding Fan Operation and Performance
TEAM UP! FOR FAN AND PUMP SAVINGS It can be as easy as replacing an old drive belt.
Operated by the Southeastern Universities Research Association for the U.S. Department of Energy Thomas Jefferson National Accelerator Facility Page 1.
automation 4 me TYPES OF LOAD 1 automation 4 me CONSTANT TORQUE LOAD : PERCENT SPEED NOTE:- A CONSTANT TORQUE LOAD IS NOT NECESSARILY 100% LOAD TORQUE.
The International Authority on Air System Components Fan Performance Mark Stevens Director of Laboratory Services AMCA International.
People who care Increasing Profit & Contributing to Global Sustainability (Reducing carbon footprint through effective compressed air management) Presented.
Directional Control Valve CV691. Present system New Proposed System with CV691 valve Directional Control Valve CV691 with integrated Flow Control Valve.
Variable Frequency Drives and Irrigation Pumps Stefanie Aschmann Bozeman, MT 11/30/11 1.
Fan Performance and Selection
Cleanrooms: Two promising research areas William Tschudi – LBNL Peter Rumsey – Rumsey Engineers November 4, 2004.
Improved Precision Leading to Improved Energy Efficiency Edward Decker AE 790 – Intelligent Buildings June 6, 2006.
Agriculture Ventilation Fans: A National Energy Efficiency Standard R. D. MacDonald, P.Eng, M. E. Armstrong, P.Eng, and K. Gibb, Agviro, Inc., Guelph,
Air quality made simple A Balanced Approach Whole House Ventilation and IAQ Airflow Control Make-up Air Solutions Application by Geographic Region.
HVACR416 - Design Pressure Measurement Part 1. Why Measure? Need to Make Sure: All combustion appliances vent properly All HVAC systems are installed.
AMCA International Technical Seminar 2009 Energy Efficiency Classification for Fans John Cermak, Ph.D., P.Eng., M.Sc. Executive Vice President ACME Engineering.
Introduction to Energy Management. Week/Lesson 10 Air Moving Equipment: Fans and Ducts.
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Are you sitting… well? About comfort,. As a responsible of occupant comfort, we all have a duty to make a careful selection of appropriate diffusers and.
Objectives Describe room distribution basics Select diffusers
Designing Efficient Blower
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Kaeser Compressors, Inc.
Course Exam Next Thursday (April 15) 7 pm Same classroom (ECJ 7.208) 2.5-hour exam Open book open notes All problem types of questions (short but comprehensive)
Air balance inc. abi Mr. Greg Crosby: VP of Sales & Marketing Mr. Ken Wahlers: VP of Manufacturing.
 2008 Kaeser Compressors, Inc., USA (V4.1) SFC Product Introduction “Specifications are subject to change without notice” 1 SFC Sigma Frequency Controlled.
ENERGY CONSERVATION IN MOTOR SYSTEMS. Introduction 2.
1 Detailed EM&V Approach for each of BGE’s Proposed Conservation Programs January 10, 2008.
Review of ABB Drives. 1.Direct torque control explains what DTC is; why and how it has evolved; the basic theory behind its success; and the features.
Implementing Wind Responsive VAV Exhaust Systems at NREL's ESIF Building: A Four-Year Follow-Up Otto VanGeet, PE, NREL Brad Cochran, CPP I2SL -August 29,
About the AMCA Certified Ratings Program
Robert Greenwald, P.Eng, MBA February 26, 2004
How to Ensure AMCA-Certified Products Get Installed
An Introduction to AMCA
Part 4 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Yaskawa Electric America on Variable Torque Loads
Maria’s Restaurant Chapter 3 Section 13
Part 2 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Kaeser Compressors, Inc.
Parul Institute of Technology
High Performance HVAC Installation
System One Pumps Selecting Centrifugal Pumps S1-201
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Mandatory Design Requirements
Introduction to Air Movement and Control Association International
Copyright Materials This educational activity is protected by U.S. and International copyright laws. Reproduction, distribution, display, and use of.
Introducing the Fan Energy Index Metric for Energy Efficient Fan Systems
Presented by Mike Zacharias
Presentation transcript:

How to Save Energy in Air Systems

Originally Presented by Michael Ivanovich, Senior Director, AMCA international mivanovich@amca.org Steve Dikeman, President, AcoustiFLO stevedikeman@acoustiflo.com

Learning Objectives Ivanovich About AMCA Value of Certified Products Damper Leakage Dikeman System Effect  System Leakage Right-Sizing Fans Here are the things we will be going over today.

What is AMCA? Air Movement and Control Association International, founded in 1917 Not-for-profit manufacturers association of fans, dampers, louvers and other air movement and control products Mission is to promote the health, growth and integrity of the industry

What is the AMCA Certified Ratings Program? How AMCA’s Certified Ratings Program works: Companies send products to AMCA for testing AMCA tests products for parameters specified AMCA checks its data against manufacturer literature After certification, the product Is licensed to bear AMCA’s seal Is listed in AMCA’s online database The AMCA CRP was developed in response to a need for validated product performance ratings Buyers, specifiers, and users of air movement and control devices needed to know they were getting what they paid for. AMCA created the CRP to provide third-party verification of manufacturer data, and it 1. Companies send products to the AMCA laboratory for testing, requesting certification for performance parameters 2. AMCA tests products for parameters specified by the manufacturer 3. AMCA checks its test data against the data the manufacturer provided to verify it is the same, within a certain tolerance Only after the product has been tested and the manufacturer’s cataloged ratings have been approved can manufacturers display the AMCA seal for the parameters tested.

The Cost of Inefficient Products Centrifugal fan Performance out of tolerance > 6% AMCA fan energy waste calculator Centrifugal fans check-tested at AMCA every three years 25% fail – data from failures used to create an online calculator http://www.amca.org/certified-listed/fanenergywastecalculator.php

Data from Failed Tests

Data from Failed Tests

The Cost of Inefficient Products What if dampers leaked more than rated? What if louvers had higher pressure drop? What if …? Why gamble?

Damper Leakage

Damper Leakage

Damper Leakage

System Effect: 1ST Definition Installed duct configuration does not match tested duct configuration

System Effect: 2nd Definition Even when the tested duct configuration matches the installed duct configuration, improper duct design can introduce adverse flow conditions

Rules of Thumb Minimum 2.5 duct diameters on outlet Minimum 3 to 5 duct diameters on Inlet Avoid inlet swirl

Recommendations 1. Allow enough space in the building design for fan connections 2. Use allowances in design calculations when space is a factor 3. Reference AMCA 201 4. Include allowance for the effect of all accessories and appurtenances Allow enough space in the building design to allow for appropriate fan connections to the system Take into account the fact that the total cost for the building is the original capex cost plus the cost to operate it 2. Use allowances in the design calculations when space or other factors dictate less than optimum arrangement of the fan outlet and inlet connections 3. Reference AMCA 201 4. Include adequate allowance for the effect of all accessories and appurtenances on the performance of the system and the fan Belt drive loss VIVs Belt guards

System Leakage Establish level of tightness needed Specify air system components and sealants that perform together as a system Select a testing standard that ensures the leakage objective is met 2012 ASHRAE Handbook—HVAC Systems and Equipment and 2013 ASHRAE Handbook— Fundamentals Establish level of tightness (system leakage percentage) that the project merits, Specify air system components and sealants that will perform together as a system to meet the system leakage objective. Select a testing standard that contractors or commissioning providers will use to ensure the leakage objective is met. 2012 ASHRAE Handbook—HVAC Systems and Equipment and 2013 ASHRAE Handbook—Fundamentals

Right Sizing Fans Efficient Quiet Cheap …Select any two!

Constant Speed Air Systems Variable volume air systems = variable speed systems Constant volume systems with variable pressures = variable speed systems Night setback, after hours, weekend modes are candidates for variable speed Constant speed air systems are neither constant volume or constant pressure Variable volume air systems are obvious examples of variable speed systems Constant volume systems with variable pressures are variable speed systems (healthcare, labs) Night setback, after hours, weekend modes are candidates for variable speed Constant speed air systems are neither constant volume or constant pressure

Variable Speed Air Systems Minimal reduction in speed offers a massive reduction in input power 90% speed  73% impeller bhp 80% speed  50% impeller bhp 70% speed  34% impeller bhp 60% speed  22% impeller bhp

Design Wheel Speed For every duty point, there is an optimum wheel speed. Pulleys and belts Direct drive No belts and speed control! For every duty point, there is an optimum wheel speed. Pulleys (and belts) provide unlimited speeds and constant wheel speed Direct drive - motor speed will seldom be optimum wheel speed, changing motor speed offers unlimited wheel speeds No belts and speed control!

Belt Loss 3% to 10% 4% to 15% 6% to 22%

Right-Sizing Fans Design flow (includes a safety factor) Design pressure (includes a safety factor) Filter loading (all filters at the same time) Plus another safety factor? Input flow and pressure into selection software

Right-Sizing Fans Fan diameter (inches) Input power (bhp) 30” 10.2 27” 10.3 24” 10.7 22” 11.9 20” 14.4 All selections require a 15 HP motor. Unless input power is defined which wheel will you get? – the cheapest/smallest A 42% difference in energy consumption “It’s only 4.2bhp” (12,000cfm at 4”)

Fans are Simple Machines

Fans are Simple Machines The smallest wheel – design flow & 80% pressure. Fan efficiency down yet another 5% from the selection point

Fans are Simple Machines Largest wheel – design flow & 80% pressure. Still near design efficiency

Right-Sizing Fans Imperative to specify a maximum absorbed power “Bigger wheel” minus “slower speed” isn’t always better For VAV supply fans, reset minimum pressure set point Evaluate the fan curve, not just the tabular output Imperative to specify a maximum absorbed power Impeller input bhp is one metric Motor input kW another “Bigger wheel”-“slower speed” isn’t always better. More low frequency sound might require a sound trap and higher pressure For VAV supply fans, best efficiency can be problematic regarding turn down . Reset minimum pressure set point!! Evaluate the fan curve, not just the tabular output

Questions? Contact Information Michael Ivanovich: mivanovich@amca.org Steve Dikeman: stevedikeman@acoustiflo.com