PV STREET LIGHTING SYSTEM IN MARGINENI COMMON

Slides:



Advertisements
Similar presentations
ERA SOLAR PRODUCTS ERA Renewable Energy. Solar energy is the ultimate source of energy from millions of years and it is a renewable energy. This energy.
Advertisements

SMART STREET LED LIGHT LUX-CE
ACEMCO s.a.l..  ACEMCO has a partnership with one of the world’s biggest and most reliable manufacturer of solar lights: Geo-Technik.  Geo-Technik is.
Electric fish barriers NEPTUN. 1.“Informational” electric field - electric energy absorbed to scare not to stun the fish. 2.Random alterations – prevent.
Introduction Since the beginning of the oil crises, which remarkably influenced power development programs all over the world, massive technological and.
Prepared by: Hamzah Snouber For: Dr. I mad Breik.
ACCIAIO LED Beghelli.
Solar Charge Controller With Dump Load Circuit Built By Matt Smyrski.
Solar Home UPS 850VA & 1400VA India’s first Sine wave inverter with in built Solar Charge Controller and Controlled DC Load Output. Simultaneous Charging.
Internal Resistance of a Source Definition: The resistance within a battery, or other voltage source, that causes a drop in the source voltage when there.
 Our energy efficient house is located in Los Angeles, California.  The 3 energy reducing features in our home are solar panels, Energy Star light bulbs,
Sustainable Energy Systems Engineering Peter Gevorkian Ch 2: Solar Power Generation Design Brevard Community College EST1830 Bruce Hesher.
TECHNICAL OVERVIEW BY DIAMOND GREEN ENERGY CORPORATION.
Hybrid Wind & Solar Generation Project
Designing Solar PV Systems (Rooftops ). Module 1 : Solar Technology Basics Module 2: Solar Photo Voltaic Module Technologies Module 3: Designing Solar.
County Council Prahova Region Location Energy Generation.
The Influence of Climatic Factors on the Performance of Photovoltaic Panels PhD. Student Mirela Mihai, U.P.B Professor Dr. Eng. Ruxandra Vidu, U.S. Davis.
SOLA R POWE R. Solar Power is generated from the PV (Photovoltaic) solar panels and delivered to the control centre. The control centre is made up of.
Secondary legislation on renewable today and tomorrow Nicolae Opris Vicepresident, ANRE ANRE ROMANIAN ENERGY REGULATORY AUTHORITY.
Battery Backup PV Systems Design Considerations
INNOVATION BUS GROUP:INNOTHENTICTECH PHASE 1 REFURBISHED BUS THIS PRESENTATION CONCETRATES ON POWER SUPPLY AND LOADS ONLY.
Website:
THE SUSTAINABLE COMPANY Development of entrepreneurship in vocational education Leonardo Project Second Meeting Tenerife – February 2013 Spanish team presentation.
Connecting Low Carbon Generation Clive Goodman Primary System Design Engineer.
Economic Comparison off Grid System. Q1 : Sizing of Solar Panel System Let us consider that one house needs following loads; 10W, 2 lamps for 3 hours.
Introduction to Power Save LED Module March 2015.
Portable Power Station University of Wyoming Electrical and Computer Department EE Done By Mohammad S. Almoallem Mahmood S. Almoallem Advised.
1. 2 PRODUCTS OF C.E.L Solar Photovoltaic Cells Solar Photovoltaic Modules Cathodic Protection Electronic Ceramics Railway Electronics Microwave Electronics.
By:- Aliza Ibrahim RRIMT,Lucknow. Solar street lights are raised light sources which are powered by photovoltaic panels generally mounted on the lighting.
Assessment and Design of Rooftop Solar PV system
SOLAR POWERED AIR CONDITIONER
– S O L A R – – S T R E E T – – L I G H T –
Photovoltaic and Battery Primer
SOLREV Energy is a sister company of the US based Isla Energy Inc
STREET LIGHT POWERED BY SOLAR
Flood Lighting PRODUCT SPECIFICATION OVERVIEW Model No. Description
Study concerning optimization of photovoltaic lighting system in Margineni village By: Dora Okos Bacau,
Beghelli-Elplast Introducing
PRESENTED BY:- ANKITA SRIVASTAV ROLL NO PRN NO
Luebeck, June 2011 Katrin Mett
Institute for Energy and Transport
The PV Cell Cell, Module & Array.
Asst. Prof. Dr. Sameer Saadoon Algburi
Solar Energy Improvement Techniques
A Microcontroller Based Power Management System for Standalone Micro grids With Hybrid Power Supply 1.
ABB i-bus® KNX Valve Drive Actuator VAA/A
Luebeck, June 2011 Katrin Mett
Photovoltaic Systems Engineering Session 15 Stand-Alone PV Systems
PV STREET LIGHTING SYSTEM IN MARGINENI COMMON
An-Najah National University
Specification & Description
Photovoltaic Module Solet P60.6-BF-250/265
Solar Charge Controllers
Specification & Description
By: Raed Wa’el Ennab & Raja Sa’ed Anabtawi
The Design Process Abstraction & Synthesis Part II Solar Candle Continued… by Prof. Bitar.
Renewable energy sources
ACCIAIO LED Beghelli.
SOLAR INSTALLATION AND DESIGN: THE DOS AND DON’TS
Battery 101.
NATIONAL LIGHTING CODE
Self-Adjusting Jacket ECE 445 SP2017
CONSTRUCTION PROJECT IN YAGOTYN DISTRICT, KIEV REGION
Photovoltaic Systems Engineering Session 10
Photovoltaic Systems Engineering Session 16 Solar+Storage Systems
Case Studies on Field Deployment of PV Battery Storage Systems
Indoor Off-Grid and Grid Lighting
CHARACTERISTICS OF ELECTRICITY
Arduino Based Solar Street Light
Presentation transcript:

PV STREET LIGHTING SYSTEM IN MARGINENI COMMON

European Regional Development Fund (ERDF) „ The achieving of street lighting in Margineni by using solar energy” Funding European Regional Development Fund (ERDF) Operation 4.2 ."Supporting investments in upgrading and building of new capacity for the electricity and heat production by harnessing renewable energy sources: biomass, hydropower resources (in units with installed up to10 MW), solar, wind , biofuel, geothermal and other renewable energy resources Total amount 3.5 mil euro

98% MIN. ECONOMY Eligible Costs 2% L. C. MARGINENI Project Ineligible Costs BACAU County Council+ L. C. MARGINENI (Lighting fixtures)

HISTORIC F.S. SUBMISSIONS F. S. Done 04.2010 01-04.2010 FINANCING AGREEMENT 09.2013 WORKS CONTRACT 09.2014 WORKS FINISH 10.2015

8 VILAGES including two types of road classified as EN 13433 GENERAL DATA MARGINENI COMMON 8 VILAGES including two types of road classified as EN 13433 M3: 15 km ( DN 2G + DJ119B) - 30 m distance between poles M5: 55km ( D.C.) - 50 m distance between poles STREET LIGHTS - 1606 INDEPENDENT PILLARS

COMPONENTS 2 PANELS 1 LED LAMP 1 CONTROLLER 1 PILLAR 2 ACCUMULATORS INDEPENDENT PILLAR

PHOTOVOLTAIC PANEL CHARACTERISTICS P = 240 W T max= 29.8 V I max= 8.06 A P = 172 W T max= 26.78 V I max= 6.7 A I sc= 6.95 A Design features Number of cells: 60 Cell type: polycrystalline Internal drainage channels frost Length / width / height: 1700/100/50 box connections Mounting and connection accessories In laboratory condition Photovoltaic panel (240W) In real conditions

ACUMULATOR PILLAR Without maintenance Type: Deep-cycle Electrolyte: acid sulfate Nominal voltage: 12 V 100Ah nominal capacity Hardened safety valve Dimensions: 350/200/250 mm Material: OL37 Mounting: the base plate anchored in reinforced concrete foundation Corrosion protection by painting Height: 8 m Wind resistance: 150km / h Accessory: Mounting box controller Battery mounting box Anchors embedded in the foundation PILLAR

CONTROLLER Auto Detect operating voltage: 12V (24V) Input voltage: 47 V Maximum output voltage: 34 V Maximum output current: 20A Operating Temperature: -25 +55 Short-circuit protection Automatic voltage detection System monitoring and control of electrical parameters Multistage charging technology Voltage and current adjustment Automatic load reconnection

LAMP Aluminium housing Flat or curved treated glass lens Maximum consumption: 80W 60 W MINIMUM NET FLUX: 6400 lm 4300lm Aluminium housing Flat or curved treated glass lens Light color temperature: 3000-4500 K Driver 12-24V supply with possible settlement at least 4 hourly intervals Adjustable vertical: 0-15 degrees Temeperatura operation: -30, +35 Console: OL 37 The minimum duration to decrease the luminous flux at 90% : 50000h Protection: minimum IP66

ELECTRIC DIAGRAM

Inclined Panel : 35-45 degrees DESIGN INFORMATION The annual average of sun glow - 2000 hours The annualaverage of temperature: 8-9 ° C Maximum temperature: 38.8 degrees C Minimum temperature - 32.5 degrees C The average value of speed wind: 2.1 m / s Inclined Panel : 35-45 degrees The system has been made so as to ensure the functioning for at least 3 consecutive days without any solar energy intake.

GENERAL DESIGNER : SC FINANCE PROIECT SRL, ing. Ciuche Dan RESISTANCE DESIGN : SC AMA-ZING SRL, ing. Andrisoaia Gheorghe ELECTRICAL DESIGNER : SC NEXANO CONSULTING SRL ing: Danila Nicu

cronic

THANK YOU FOR YOUR ATTENTION!