New optics for X’Pert PRO

Slides:



Advertisements
Similar presentations
(see Bowen & Tanner, High
Advertisements

Focusing monochromators/analyzers Asymmetric diffraction geometry of the monochromator Dispersive double crystal monochromator Two wavelength sandwich.
Interference and Diffraction
CHAPTER 3: CRYSTAL STRUCTURES X-Ray Diffraction (XRD)
Internal – External Order We described symmetry of crystal habit (32 point groups) We also looked at internal ordering of atoms in 3-D structure (230 space.
X-Ray Crystallography The most important technique for mineralogy The most important technique for mineralogy Direct measurement of atomic arrangement.
Diffraction of Light Waves
A plane monochromatic light wave is incident on a double slit as illustrated in Active Figure As the viewing screen is moved away from the double.
Copyright © 2010 Pearson Education, Inc. Lecture Outline Chapter 28 Physics, 4 th Edition James S. Walker.
Properties of Multilayer Optics An Investigation of Methods of Polarization Analysis for the ICS Experiment at UCLA 8/4/04 Oliver Williams.
Tuesday, May 15 - Thursday, May 17, 2007
Diffraction through a single slit
Chapter 25: Interference and Diffraction
Problems with Bragg-Brentano diffractometer geometry Multilayer optics.
Chapter 5 Telescopes: “light bucket”. Telescopes have three functions 1.Gather as much light as possible: LGP ∝ Area = πR 2 LGP ∝ Area = πR 2 Why? Why?
Chapter 6: The Tools of the Astronomer. Telescopes come in two general types Refractors use lenses to bend the light to a focus Reflectors use mirrors.
X’Pert Epitaxy Software Version 3.0
Applying X-Ray Diffraction in Material Analysis Dr. Ahmed El-Naggar.
BROOKHAVEN SCIENCE ASSOCIATES BIW ’ 06 Lepton Beam Emittance Instrumentation Igor Pinayev National Synchrotron Light Source BNL, Upton, NY.
PHENOMENA OF LIGHT Chapters 27, 29, & 31. Easy to get mixed up… Polarization (Light)Ch 27 Reflection (Water & Light)Ch 29 Refraction (Light)Ch 29 Dispersion.
1 Electromagnetic waves: Multiple beam Interference Friday November 8, 2002.
D8DISCOVER-for-Material-Research.1: Dr. H. R. Reß © 1999 BRUKER AXS All Rights Reserved D8 DISCOVER for Material Research.
Micro-mirror Micromechatronics System FH AACHEN
Assessing Single Crystal Diamond Quality
Light Wave Interference In chapter 14 we discussed interference between mechanical waves. We found that waves only interfere if they are moving in the.
Difference of Optical Path Length Interference Two waves One wave Many waves Diffraction.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
Page 1 Phys Baski Diffraction Techniques Topic #7: Diffraction Techniques Introductory Material –Wave-like nature of electrons, diffraction/interference.
Higher Physics – Unit Waves. a a λ λ crest trough Wave Theory All waves transmit energy. The energy of a wave depends on its amplitude. a = amplitude.
1 Electromagnetic waves: Reflection, Transmission and Interference Monday October 28, 2002.
Chapter 5 Telescopes Chapter 5 opener. This composite photograph shows two of the premier optical telescopes available to astronomers today. At the top,
Phase Contrast sensitive Imaging
The HESSI Imaging Process. How HESSI Images HESSI will make observations of the X-rays and gamma-rays emitted by solar flares in such a way that pictures.
Astronomy: A Beginner’s Guide to the Universe Seventh Edition © 2013 Pearson Education, Inc. Chapter 3 Lecture Telescopes.
Neutron Scattering Group February, 2001 A High Performance Instrument for the Single Crystal Spectroscopy at the Pulsed SNS. n What is the spectrometer.
Physical optics Done by P G LOGAN. Physical optics Physical optics deals with phenomena that depend on the wave nature of light. There are three types.
Fourier transform from r to k: Ã(k) =  A(r) e  i k r d 3 r Inverse FT from k to r: A(k) = (2  )  3  Ã(k) e +i k r d 3 k X-rays scatter off the charge.
X-ray diffraction for today and tomorrow
October, 2001 Hybrid Spectrometer for Single Crystal Studies at the Pulsed SNS: an update. n Principal features of the proposed hybrid spectrometer. n.
X-RAY METHODS FOR ORIENTING CRYSTALS
Lecture 26-1 Lens Equation ( < 0 )  True for thin lens and paraxial rays.  magnification m = h’/h = - q/p.
VERTICAL SCANNING INTERFEROMETRY VSI
Chapter 35-Diffraction Chapter 35 opener. Parallel coherent light from a laser, which acts as nearly a point source, illuminates these shears. Instead.
Chapter 35-Diffraction Chapter 35 opener. Parallel coherent light from a laser, which acts as nearly a point source, illuminates these shears. Instead.
Diffraction in TEM Janez Košir
Other imaging techniques
Light.
© 2017 Pearson Education, Inc.
Laser Physics & Nonlinear Optics
Diffraction through a single slit
Space Tools 4.10 Here is a satellite image of the east coast of the United States at night. This is a satellite image because the space technology is.
NANO 230 Micro/NanoFabrication
Reflectivity Measurements on Non-ideal Surfaces
Determining the Index of Refraction of AlF3
Waves & optics Newton Rings By GurwinderSingh 1043/12 To j.p.sir
1 Electromagnetic waves: Interference Wednesday October 30, 2002.
Light Through a Single Slit
Substrate High Resolution Medium Resolution Substrate Substrate
How to Use This Presentation
Chapter 35-Diffraction Chapter 35 opener. Parallel coherent light from a laser, which acts as nearly a point source, illuminates these shears. Instead.
Reflectivity Measurements of Oxide Layers on Glass
The Microscopes.
MICHELSON INTERFEROMETER
Example Example 3: This experiment demonstrates the interference of light. S1 S2 S single slit slide light source translucent screen interference fringe.
Activity 1: Properties of radio arrays
Chapter 18 Section 2 Telescopes Bellringer
Crystal and X-ray Diffraction
Chapter 16: Interference and Diffraction
Unit Physical Science Systems
Presentation transcript:

New optics for X’Pert PRO The hybrid monochromator for high-resolution measurements In this presentation, the use of the 4-bounce hybrid monochromator for high-resolution measurements is explained. It is shown, by measurements on a superlattice, that the hybrid monochromator can best be used when fast collection of data with a good resolution is required. For ultra-high resolution, the Ge(220) and Ge(440) 4-crystal monochromators are better, but measurement times are much longer.

Contents What is a hybrid monochromator? For which applications can it be used? What is the advantage in the analysis of epitaxial layers? Contents of the talk: it will be shown what a hybrid monochromator is, for which applications it can be used and what the advantage is when the hybrid monochromator is used for high-resolution measurements of epitaxial layers.

What is a hybrid monochromator? A combination of an X-ray mirror and a channel-cut Germanium crystal Only Cu K1 is transmitted The combination gives a high-intensity, parallel, monochromatic X-ray beam Two varieties: two bounces in the monochromator four bounces in the monochromator The hybrid monochromator is a combination of an X-ray mirror and a channel cut Germanium crystal. The X-ray mirror transfers the diverging beam coming from the line focus of the X-ray tube into a high-intensity parallel beam. In the Germanium crystal, only a part of the Copper K-Alpha1 line is selected.

For which applications? Two-bounce type: Phase analysis on rough samples with complex patterns Samples in glass capillaries Four-bounce type: Measurement of rocking curves and reciprocal space maps How are these two types positioned with respect to each other? One is meant for phase analysis of powder samples for which a monochromatic parallel beam is required. In this monochromator, two bounces (reflections) of the X-ray beam in the Germanium crystal yield a strong signal with a divergence of about 25 arcseconds (about 0.007°). Optionally, it can be used for measurement of rocking curves and reciprocal space maps when intensity is of higher importance than resolution. The other one has four reflections in the Germanium crystal and is meant for fast measurement of rocking curves and reciprocal space maps. It has a divergence of 18 arcseconds (about 0.005°). In the remainder of this talk we will discuss the four-bounce hybrid monochromator and demonstrate its capabilities when compared with other monochromators.

Example: measurements on a superlattice What is a superlattice? What is the layer thickness? GaAs substrate GaAs AlAs 8 x } In order to demonstrate the power of the hybrid monochromator, we consider an example, measurements on a superlattice. A superlattice is a periodic repetition of several layers with different composition. Superlattices are used for many applications, such as Bragg reflectors, quantum wells and wave guides. We use this sample to demonstrate the versatility of the X’Pert PRO MRD for analyzing such a superlattice with different optical components.

Which instrument? X’Pert PRO MRD: Standard MRD Extended MRD In the next slides we will show the usefulness of the four-bounce hybrid monochromator on a standard MRD and on an extended MRD.

Standard X’Pert PRO MRD Tube focus: point Ge(440) monochromator Ge(220) monochromator Tube focus: line four-bounce hybrid monochromator For the standard MRD, we have four possibilities. Depending on the demands on resolution and intensity, one can choose different incident beam monochromators. With the tube rotated to the point focus position one can choose between the Ge(440) 4-crystal monochromator, the Ge(220) 4-crystal monochromator and the Ge(220) asymmetrical 4-crystal monochromator. In this example we will take a look at the first two only. Once the tube is rotated to the line focus position, it is possible to use the four-bounce hybrid monochromator. On the next slide we will compare the different measurements in one graph, created with the Philips X’Pert Epitaxy software package.

This graph shows the difference in intensity between the three monochromators. In each experiment, the illuminated area on the sample was taken as large as possible. The size of the illuminated area thus depended on the perfection of the sample. Because the measurement with the Ge(440) high-resolution 4-crystal monochromator was most sensitive to sample imperfections, the smallest beam size was used in that experiment. For the other measurements it was found that the beam size could be increased without decreasing the resolution. On the next slide we will show the trade-off between resolution and intensity in more detail by zooming in on the central peaks.

This graph shows the trade-off between intensity and resolution in more detail. In the high-resolution measurement with the Ge(440) monochromator, fine fringes between the main peaks are visible, resulting from the interference between the diffracting X-rays. The presence of these fringes illustrates the perfectness of the superlattice sample. With the hybrid monochromator however, the superlattice peaks are clearly resolved with an intensity increase of more than 1000 with the hybrid monochromator. An intensity increase of about 40 is possible with respect to the Ge(220) point focus 4-crystal monochromator. Imagine the increase in efficiency you can reach by decreasing your measurement time for each sample!

Normal MRD: conclusions Features of the hybrid monochromator Intensity increase: > 30 compared with Ge(220) point focus > 10 compared with Ge(220) asymm. Fast, compact tool for reciprocal space maps and rocking curves How can this be compared with Extended MRD? The plots in the previous slide show that the 4-bounce hybrid monochromator can well be compared with the Ge(220) 4-crystal monochromator. The resolution of the hybrid monochromator is slightly lower, this can be seen in the less perfect separation between the two largest peaks in the spectrum. In terms of intensity, however, a increase of around 30 can be reached, depending on the application. In other words: the same information is gathered in 4% of the time! When compared to the Ge(220) asymmetrically cut 4-crystal monochromator (not shown in the previous slides), the resolution of the 4-bounce hybrid monochromator is comparable, the typical intensity gain will be about 10. Let us compare the 4-bounce hybrid monochromator with a diffraction system in which the 4-crystal monochromators can be used together with a separate X-ray mirror; the so-called Extended MRD.

Extended MRD Mirror with Ge(220) and Ge(220) asymmetrically channel-cut monochromator Compare with four-bounce hybrid monochromator and with Ge(220) point focus In this case, we will compare the following configurations: tube focus: line X-ray mirror with 4-crystal Ge(220) monochromator X-ray mirror with asymmetrically cut 4-crystal Ge(220) monochromator 4-bounce hybrid monochromator tube focus: point 4-crystal Ge(220) monochromator

It is clear that in this case the difference between the hybrid monochromator and the mirror + 4-crystal monochromators is less pronounced.

Especially in this picture it can be seen that the resolution of the 4-bounce hybrid monochromator is comparable to the asymmetrically cut 4-crystal Ge(220) monochromator in combination with the separate X-ray mirror.

Conclusions (1) Let us compare the intensities of the possible incident beam optical modules for the analysis of epitaxial layers.

Conclusions (2) The four-bounce hybrid monochromator is an excellent tool for fast measurements of rocking curves and reciprocal space maps It can best be used when high intensity is required in combination with moderate resolution When ultra-high resolution is required, it is easy to change to a four-crystal monochromator In this talk I have introduced the hybrid monochromator to you. Two types of hybrid monochromator exist, the 2-bounce and the 4-bounce hybrid monochromator. The 4-bounce types is mainly designed for measuring rocking curves and reciprocal space maps. It can best be used when a high intensity is required at moderate resolution. When ultra-high resolution is required, the hybrid monochromator can easily be exchanged for a four-crystal monochromator. The ultimate flexibility is possible with an extended-MRD, in which the mirror and four-crystal monochromators can be used together. The hybrid monochromator, however gives the highest intensity and can also be used on standard MRD systems.