Transient Waveform Recording Utilizing TARGET7 ASIC

Slides:



Advertisements
Similar presentations
Interfacing to the Analog World
Advertisements

Constructing an Analog Digital Converter (ADC) to Measure Neutron Depolarization in Deuterium Aung Kyaw Sint and Dr. Alexander Komives CsI scintillator.
Analog-to-Digital Converter (ADC) And
Lecture 17: Analog to Digital Converters Lecturers: Professor John Devlin Mr Robert Ross.
COMP3221: Microprocessors and Embedded Systems
LSU 06/04/2007Electronics 71 Analog to Digital Converters Electronics Unit – Lecture 7 Representing a continuously varying physical quantity by a sequence.
Current-Mode Multi-Channel Integrating ADC Electrical Engineering and Computer Science Advisor: Dr. Benjamin J. Blalock Neena Nambiar 16 st April 2009.
Front-end electronics for Time Projection Chamber I.Konorov Outlook:  TPC requirements  TPC readout options  Options for TPC FE chips  Prototype TPC.
Data Acquisition System for 2D X-Ray Detector Beijing Synchrotron Radiation Facility (BSRF) located at Institute of High Energy Physics is the first synchrotron.
JF 12/04111 BSC Data Acquisition and Control Data Representation Computers use base 2, instead of base 10: Internally, information is represented by binary.
Large Area, High Speed Photo-detectors Readout Jean-Francois Genat + On behalf and with the help of Herve Grabas +, Samuel Meehan +, Eric Oberla +, Fukun.
© 2009 Pearson Education, Upper Saddle River, NJ All Rights ReservedFloyd, Digital Fundamentals, 10 th ed Digital Fundamentals Tenth Edition Floyd.
PH4705/ET4305: A/D: Analogue to Digital Conversion
1 Digital to Analog Converter Nov. 1, 2005 Fabian Goericke, Keunhan Park, Geoffrey Williams.
FASEP Presents What is the difference between PSD and CCD sensor technology?
Data Converters ELEC 330 Digital Systems Engineering Dr. Ron Hayne
Electronics Involves the use of devices and circuits to control the flow of electric current to achieve some purpose. These circuits contain: Resistors,
Digital Fundamentals Floyd Chapter 1 Tenth Edition
Development of Readout ASIC for FPCCD Vertex Detector 01 October 2009 Kennosuke.Itagaki Tohoku University.
Adopting Multi-Valued Logic for Reduced Pin-Count Testing Baohu Li, Bei Zhang and Vishwani Agrawal Auburn University, ECE Dept., Auburn, AL 36849, USA.
Electronics for PS and LHC transformers Grzegorz Kasprowicz Supervisor: David Belohrad AB-BDI-PI Technical student report.
Gunther Haller SiD LOI Meeting March 2, LOI Content: Electronics and DAQ Gunther Haller Research Engineering Group.
Data Acquisition Systems
© 2009 Pearson Education, Upper Saddle River, NJ All Rights ReservedFloyd, Digital Fundamentals, 10 th ed Digital Fundamentals with PLD Programming.
10/26/20151 Observational Astrophysics I Astronomical detectors Kitchin pp
Data Acquisition ET 228 Chapter 15 Subjects Covered Analog to Digital Converter Characteristics Integrating ADCs Successive Approximation ADCs Flash ADCs.
Floyd, Digital Fundamentals, 10 th ed Digital Fundamentals Tenth Edition Floyd © 2008 Pearson Education Chapter 1.
Team 2 Yimin Xiao Jintao Zhang Bo Yuan Yang.  An ability to sample analog voltage signal range from -12 V to 12 V via BNC;  An ability to reconstruct.
1 Status Report on ADC LPC Clermont-Ferrand Laurent ROYER, Samuel MANEN.
Digital to Analog Converter (DAC)
- Herve Grabas - Ecole Superieure d’Electicite 1 Internship presentation - University of Chicago – 3 sept
PCAR Precision In Practice 1 Precision In Practice Achieving the best results with precision Digital Multimeter measurements Paul Roberts Fluke Precision.
Lecture Notes / PPT UNIT III
Sampling. Introduction  Sampling refers to the process of converting a continuous, analog signal to discrete digital numbers.
Digitization at Feed Through Wu, Jinyuan Fermilab Feb
FUNCTION GENERATOR.
 13 Readout Electronics A First Look 28-Jan-2004.
What is the difference between PSD and CCD sensor technology?
MECH 373 Instrumentation and Measurements
DAQ ACQUISITION FOR THE dE/dX DETECTOR
EKT124 Digital Electronics 1 Introduction to Digital Electronics
Ivan Perić University of Heidelberg Germany
A 2 Gsps Waveform Digitizer ASIC in CMOS 180 nm Technology
Jinfan Chang Experimental Physics Center , IHEP Feb 18 , 2011
B.Sc. Thesis by Çağrı Gürleyük
CTA-LST meeting February 2015
Analog-Digital Conversion
SCADA for Remote Industrial Plant
Yuzhe Liu1,2, Lian Chen1,2, Futian Liang1,3, Feng Li1,2, Ge Jin1,2
96-channel, 10-bit, 20 MSPS ADC board with Gb Ethernet optical output
KRB proposal (Read Board of Kyiv group)
MPGD Detectors and Electronics at CIAE
Shanshui Yang1, Li Liu1, Xi Jiang1, Li Wang1, Weifang Liu2
A First Look J. Pilcher 12-Mar-2004
Analog to Digital Converters Electronics Unit – Lecture 7
Hellenic Open University
A Low Power Readout ASIC for Time Projection Chambers in 65nm CMOS
Digital Acquisition of Analog Signals – A Practical Guide
Digital Control Systems Waseem Gulsher
The New Readout Electronics for the SLAC Focusing DIRC Prototype (SLAC experiment T-492 ) L. L. Ruckman, G. S. Varner Instrumentation Development Laboratory.
BESIII EMC electronics
Digital instrumentation – Unit 1
Conversation between Analogue and Digital System
Digital Fundamentals Floyd Chapter 1 Tenth Edition
Data Acquisition (DAQ)
Analog-to-digital converter
FAN5358 2MHz, 500mA, SC70 Synchronous Buck Regulator
CAL crosstalk issues and their implications
A 12 bit 50 MS/s Dual Channel Time Domain Two Step ADC
A 12 bit 50 MS/s Dual Channel Time Domain Two Step ADC
Presentation transcript:

Transient Waveform Recording Utilizing TARGET7 ASIC J. Zhang, S. Liu*, Y. Wang, C. Yang, X. Zhu, C. Feng University of Science and Technology of China Presented by Yu-Wang(Nick) Good afternoon everyone. With today’s technology, more and more electronics element such as cellophane and computer become smaller and smaller, and what we have done is to make detectors smaller 15’(0:00-0:15)

Signal In Real World and Computer Analog signal in real world Such as sounds Hard to store and process Digital signal in computer Computer only know 0 and 1 Easy to store Computer can process Convert analog signal to digital signal Need an element: ADC(Analog-Digital Convertor) In electronics world, the most important thing is to convert analog signal to digital one. All the signal in real world we call it analog signal, such as sound and movement, it’s hard to store and can only be processed by human. The signal that computer can understand we call it digital signal, it is just 0 and 1. It’s easy to store and can be processed by computer quickly. The element between analog and digital we call it Analog-Digital Convertor (short as ADC) 40’(0:15-0:55) 2018/1/30

Technology In Particle Detector Traditional way Cannot get the waveform Record the amplitude of the signal Advanced way Record the waveform using fast ADC Only record one waveform in one chip Our new way Record 16 waveform in one chip In traditional way, particle detector can not record the waveform of signals, it can only record the amplitude of the signal, so that lots of information is lost. In recent years, an advanced way has been developed. With the help of fast ADC, detector can record the waveform of the signal. Waveform means more accurate measurement and more information. But modern physics experiments need to record tens of thousands signal at one time. We have developed a new method to achieve this goal. 40’(0:55-1:35) 2018/1/30

TARGET-7 ASIC ASIC(Application-Specific Integrated Circuit) TARGET-7 An integrated circuit (IC) customized for a particular use TARGET-7 An IC designed for high-speed and multi-channel particle detector 16 input channels Can convert 100 billion signal in one second Just as big as a coin We used an ASIC to realize this. An ASIC is an integrated circuit customized for a particular use. Our TARGET-7 ASIC is an IC for high-speed and multi-channel particle detector. It has 16 input channels and just as big as a coin. Target7 can convert 100 billion times in one second. 30’(1:35-2:05) 2018/1/30

Detail of TARGET-7   It has two main parts, the analog and digital part. The analog part has 16 input pins. Due to the switched-capacitor array(short as SCA) the analog part can store 2^16 signals, we call this kind of store acquisition. The digital part use 16 Wilkinson ADC to convert the analog signal. It uses a method called ping-pang way to reach 100 billion sample rate. 40’(2:05-2:45) 2018/1/30

Design of the Test-Board Use FPGA to Control as Master FPGA: CPU like element, Can process multiple task at one time Structure of Test-Board Signal Control Command Data The first step of our work is to design a test-board for target-7. We use an FPGA to control the Target-7.This is the structure of out test-board. The computer send a command to the FPGA, then the FPGA control the Target-7 to convert the signal. When the conversion is done, the FPGA get the data and transfer to the Computer 30’(2:45-3:15) Data 2018/1/30

DC(Direct Current) Transfer Function Relation Between Signal and Data ADC counts is a function of input signal Result Linear voltage:0.5~1.8V 552 to 3785 ADC counts 11.6-bits resolution The next step is testing the board. This is the DC transfer function of out board. DC means direct current. The ideal function line should be linear. We measured our test board and get the linear voltage area which is 0.5V~1.8V. This represents 11.6-bits resolution. It corresponds this area in the figure. Also we can see, there are many nonlinear factors. 40’(3:15-3:55) 2018/1/30

Voltage Calibration   We need to do some calibration to correct the nonlinearity. The 16 channels have different offset and this will cause mismatch. A more important reason to calibrate is there are differences among the storage cells. These differences may cause serious distortion. So that, we developed series of methods to calibrate the voltage. We calibrate every cell individually and use polynomial fit to get the calibration parameters. 40’(3:55-4:35) 2018/1/30

Voltage Calibration Result Before calibration After calibration These figures show the result of the calibration. Two of the upper figures is the signal without calibration. There are serious nonlinearity and distortion in the signal. The lower two figures is the signal after calibration. There is no distortion on it and the nonlinearity is 1%. The calibration is effective. 30’(4:35-5:05) 2018/1/30

AC(Alternating current) Performance AC Transfer Function Using sinusoidal signals as input Linear in low amplitude(<0.6V) AC saturation happens in high amplitude(>0.6V) Another important parameter we care about is the AC performance, AC means alternating current. We use sinusoidal signal as input to test the AC transfer function. It show that when the signal is smaller than 0.6V, the function is linear. Nonlinearity happens when the signal is over 0.6V 40’(5:05-5:45) 2018/1/30

Application in Charge Measurement Most important information Recording charge waveform Measurement method Use CSA(Charge Sensitive Amplifier) and shaper to collect charge Compared with Oscilloscope Then we applied our test-board to charge measurement. What we need to do is to record the charge waveform to get full information. We use a signal generator to generate the charge signal. Then we used a charge amplifier to change it into waveform. To get more accurate result, we compare our result with an advanced oscilloscope. 35’(5:45-6:20) 2018/1/30

Application in Charge Measurement Result Nonlinearity of TARGET7 is 0.6% Better than oscilloscope 0.1% These two figures is the result of our test. The red waveform on the left figure is recorded by Target-7, and the black one is the result of oscilloscope. It’s clear to see that our result is 2 times more accurate than the oscilloscope. The right figure is the comparison of the nonlinearity. The nonlinearity of our test-board is 0.6%, better than the oscilloscope. The accuracy satisfies the requirements of particle experiments. 40’(6:20-7:00) 2018/1/30

Conclusion1 We have designed a 16-channel 1GSPS waveform digitizer with TARGET7 ASIC The dynamic range is 1.8V DC noise is 1.76mV After DC calibration, nonlinearity is 1.1% Timing resolution is 152ps In conclusion, the goal of our research was to design a multi-channel high seed waveform digitization system. As shown before, utilizing Target-7, we completed this goal. After this we have tested the performance of Tartget-7 and we designed a method to calibrate Target-7 These are parameters we measured. All these parameter is better than the requirements of particle experiments. 35’(7:00-7:35) 2018/1/30

Conclision2 We have applied the TARGET-7 to charge measurement The waveform record is better than the same speed Oscilloscope The nonlinearity of charge measurement is 0.6% We succeed to apply the Target-7 to charge measure experiments. The result show that our system is better than the same speed oscilloscope, the nonlinearity of our system is 0.6%. 20’(7:35-7:55) 2018/1/30

Future Work Some experiments needs millions of channels, and Target-7 ASIC is an optimal option. We need to test other ASIC as well as Target-7 New calibration methods are under investigation The final goal of our research is to apply waveform digitization method to the large-scale particle detection such as cosmic-ray detection and collider experiment. In these experiments, physicists need millions of channels to get experiment data. At present the Target-7 ASIC is an optimal option to realize the goal. In the feature research, we have two directions. One is to utilize more Tartget-7 ASIC in one system to achieve more channel acquisition. The other is to do research on higher integration density ASIC to get more data in one ASIC. At the same time, we are investigating new calibration method to get more accurate calibration. Thank you! Are there any question? 55’(7:55-8:50) 2018/1/30