Heat transfer Steady state conditions not for dynamic systems in buildings through walls, roofs, floors, windows, doors building structures and U-values.

Slides:



Advertisements
Similar presentations
Presentation Heading Air Source Heat Pumps Jordan Jeewood
Advertisements

Guidelines and Required Codes That Affect Building Design
Building Energy Rating
Heating, Ventilating, and Air-Conditioning
Tas seminar/demonstration on Part L 2006 of the Building Regulations Presented by Alan Jones EDSL February
Load Calculations Dr. Sam C M Hui MECH3005 – Building Services
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
1 ISAT Module III: Building Energy Efficiency Topic 6:Stead-State Building Loads z Fabric Loss z Ventilation Loss z Environmental Temperature z Steady-State.
The House as a System 1. Air Temperature and Water Vapor.
Heating energy calculation methods Anti Hamburg Lecture TTK-UAS.
Energy in Focus Energy Savings with Water Based Systems By Maija Virta Specialist of Indoor Environment Technology.
Passive House Seminar for the Professionals from the Building Sector.
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
The Energy Star Home Drew Tepper. Overview What is an energy star home? What is an energy star home? New Homes New Homes Existing Homes Existing Homes.
HEATING, VENTILATION AND AIR-CONDITIONING Prof. dr Maja Todorović University of Belgrade, Faculty of Mechanical Engineering.
STEAM CONDENSERS.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
CHANGES IN THERMAL ENERGY CONSUMPTION IN APARTMENT BUILDINGS OF ESTONIA Teet-Andrus Kõiv,
Heat Loss and Gain Heat Loss and Gain
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
SPF-calculation methods in Finland IEA annex 39 meeting in Tokyo Jussi Hirvonen Finnish Heat Pump Association SULPU ry.
Calculation of Energy Performance of Buildings - Lithuanian Case. Dr
Passive House Seminar for Professionals from the Building Sector
Lindab Solus - Simply the natural choice.... lindab | comfort Chilled beam revolution! + Save up to 45 % cooling energy!* + Installation and investment.
Design of HVAC systems for bld 3862 – LHCb control room and for bld 2885 – LHCb new workshop.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
Heat Exchange Ventilation Heat Exchange Ventilation.
-Too little or too much ventilation -Insufficient ventilation results in excessive indoor humidity -Uncontrolled ventilation can cause exhaust leaks within.
Lecture Objectives: Clarify issues related to eQUEST –for midterm project Learn more about various HVAC - economizer - heat recovery Discuss about the.
INTRODUCTION TO HEAT LOAD HEAT LOAD12 3 TOPICS COVERED INTRODUCTION DESIGN CONSIDERATIONS DEFINITIONS/CONCE PT/FORMULA THE FORM LOAD COMPONENTS –External.
A Closer Look at Energy Demands: Quantification and Characterisation.
Introduction to Energy Management. Lesson 4 Determining the Loads on the HVAC System.
Heat loss, U-values and all that stuff. First a bit of Science First Law of Thermodynamics You can’t get more heat out of a closed system than you put.
Contract: EIE/07/069/SI Duration: October 2007 – March 2010Version: July 7, 2009 Ventilation for buildings - Calculation methods for the determination.
Technical Seminar on Application and Technical Specification June 2016
Vendelso.
Under floor heating Designing underfloor heating (UFH) system must always comply with the system suppliers instructions.
Air source heat pump Understand the fundamental principles and
Heat Loss and Gain Civil Engineering and Architecture
Johann ZIRNGIBL CSTB / France
Under floor Heating Graduation Project submitted By: Adli Mosleh
DRAUGHT (British English) Draft (American English)
THERMAL LOADING OF BUILDINGS
Chapter 6: INFILTRATION
BUILDING HEATING AND COOLING
RESIDENTIAL HVAC (HEAT LOSS & GAIN)
Thermal mass dynamics 1.00 Heat absorption
Environmental Thermal Engineering
Heat gain and heat loss in buildings
CONFIDENTIAL Technical Seminar on Application and Technical Specification 21 June 2016 Rezza Arif Bin Mustapa Kamal Senior Engineer Project And Application.
Heat Loss and Gain.
Heat Loss and Gain Heat Transfer Winter Heat Loss Summer Heat Gain
Conduction Cooling Loads
Martti Veuro.
Heating and cooling demand in buildings
CHAPTER 3 VENTILATION.
Temperature and Heat Loss
Chapter 6A: INFILTRATION BACKGROUND
EMPTY BIN TREATMENTS Mimoun Abaraw.
Heat Loss and Gain Heat Loss and Gain
Energy performance of buildings
Heat Loss and Gain Heat Loss and Gain
ATA Melbourne Branch presentation April 2008 Jim Lambert
Heat Loss and Gain Civil Engineering and Architecture
Technology in Architecture
Smokes extraction principle
Heat Loss and Gain Heat Loss and Gain
HEAT EXCHANGE IN BUILDINGS. TERMINOLOGIES Thermal conductivity: is the rate of heat flow through a unit area of unit thickness of the material for a unit.
Heat Loss and Gain Heat Loss and Gain
Jerzy KWIATKOWSKI, Jerzy SOWA, Andrzej WISZNIEWSKI
Presentation transcript:

Principles of HEVAC design Course Spring term 2015 Heat loss calculations in buildings

Heat transfer Steady state conditions not for dynamic systems in buildings through walls, roofs, floors, windows, doors building structures and U-values National building codes (NBC) in Finland (C3 Regulations) C4 (2003, draft 2012) Thermal Insulations Guidelines D3 (2012) Energy efficiency in buildings D5 (draft 2012) Energy and heat loss calculations in buildings D2 (2012) Indoor Climate and Ventilation in Buildings Guidelines and Regulations

Heat loss calculations and heat demand for heating Introduction Heat loss calculations and heat demand for heating based on National building code D5 aim is to give information so that a student can calculate heat demand at the design outdoor temperature this information is needed for designing heating systems in buildings heating of buildings is one of the main subjects in HEVAC engineering the main purpose of heating is to maintain healthy and comfortable conditions in buildings and usually also to produce hot domestic water heating of supply and leakage air and HDW is also included in the calculations and design (Figure 1)

Calculation of heat demand in buildings Heat and energy demand are related to each other in buildings The procedure starts always by calculating heat demand for every single room or space in a building Normally any internal or external heat gains are not taken into account The heat demand for a building is got by calculating together all room and space heat demands and heat demand of air handling units By calculations can be chosen correct heating devices (boilers, heat exchangers, pipes, heat emitters etc.)

Heat demand Calculations are made for the design conditions The design conditions are the “worst” case, when heating is needed, usually the minimum outdoor temp. In all other conditions the heat output of the heating system is controlled/reduced to those (other) outdoor and indoor conditions The heat demand is calculated for every room or space because this heat demand determines the selection of the heat emitters (radiators, convectors etc.) for those rooms or spaces Dimensioning of heat production for a building is based on these calculations

Heat demand for a building The heat demand for a building is calculated according to Figure 2 η (eta) is the efficiency of each part in the heating system there are losses in every parts of the heating system like losses in production (e.g. boiler system) losses of heat storage (e.g. water tank) losses in heat distribution losses in heat emitters (e.g. under floor heating) losses in control systems If the efficiencies of each part is not known or calculated (D5 Chapter 6) then as the value of η (eta) can be used 0,9 Heat demand is the same as heat losses, only the perspective is different

Heat losses through building envelope (fabric) These are called normally as heat losses by conduction The basic information needed here are the U-values of different building components, the dimensions/areas of each component, length of joints between different parts of building elements and temperature difference between indoors and outdoors (or underground)

Heat loss calculations Thermal transmittance of a building component is U (W/m2,K) D3 (NBC) gives the reference values for thermal transmittance, mostly these are used in real buildings Usually the constructor engineers calculates the U-values New values in the beginning of the 2010 windows and doors has been especially improved Areas of building components walls, floors and roofs (ceilings) according to the internal measures of a space or room (length, width and height) windows and doors according to the measures of the installation apertures (hole) (external measures of the frames) Length of joints between building components walls, floors, roofs, windows, doors

Heat loss calculations Designing temperatures Indoor air temperature Ts from D2 year 2010 (or Indoor air classification 2008) Outdoor air temperature Tu,mit, 4 different weather zones in Finland (Appendix 1 in D3) Under floor temperatures outdoor air temp. when totally against outdoor air crawling space and ventilated = designing temp. (formula 2.10) annual outdoor average temp. – 2 K against the ground, designing temp. (Formula 2.11) annual outdoor average temp. + 2 K

Heat loss calculations Heat losses through leakage air (infiltration air) there is always uncontrolled ventilation through building envelope leakage air flow is not considered as a part of ventilation air flow leakage air flow rates are affected by e.g. the following air tightness of the building envelope the positions of the holes of leakage temp. difference between indoors and outdoors wind conditions on the site the air balance (outdoor and exhaust air flow rates) Heat demand is calculated by general formula (Formula 2.12) in D5 with (formula 2.13) in general with (Formula 2.15) Heat demand for leakage air is calculated for rooms with at least one building component against outdoor air or ground under the building

Heat loss calculations Heat losses through leakage air (infiltration air) The air flow rates are calculated with the coefficient of leakage air flow rate (called n, unit 1/h) and with the internal volume of the calculated room or space (Formula 2.16) Usually is needed the conversion from one unit to another (m3/h -> m3/s or litres/second l/s) value of n depends essentially of the tightness of the building definition of n50 (Figure 2.2) overpressure inside the building is 50 Pa air flow rate with that overpressure and the nleakage air (Formula 2.19) the procedure is n50 q50 qv,leakage air flow rate

Heat loss calculations Heat losses of ventilation The heat demand of ventilation is calculated (Formula 2.22) the density of air the temp. difference between supply air and room temp. air flow rate specific heat capacity of air the air flow rates which are used are got from the ventilation design drawings The heat demand of the air handling unit (AHU) (Formula 2.23) without heat recovery The heat demand in an AHU with the heat recovery Efficiency for heat recovery either for exhaust air or for supply air The efficiency for heat recovery for supply air (Formula 2.30) Values for temp. ratio (efficiency) in different types of heat recovery Ratio between supply air and exhaust air R

Heat loss calculations Heat losses of ventilation The power (effect, heat output) of the heat recovery TtLTO is calculated with or with exhaust air temp ratio And the power for the heating coil of an AHU the design value of the supply air temp. after the heating coil is used usually the heating coil is dimensioned for 5 °C lower temp. after heat recovery to ensure enough heating power For the whole building the heat demand of AHU’s are calculated together If there is only exhaust air system in the building (or in a part of it) all heat losses of ventilation are compensated by the heat emitters in the rooms or spaces (radiators, convectors etc.)

Heat loss calculations Heat losses (or heat demand) of hot domestic water Usually the hot domestic water (HDW) is heated in one place for the whole building (a centralized heating and distribution system) in D5 is given a general way The dimensioning flow of HDW is got by D1 Temperature difference is normally 50 °C The required temp. of HDW is +58 °C The HDW system usually always include the circulation system to avoid delay when using HDW in taps (faucets) The heat demand of circulation is very small when comparing it to the heat demand of HDW In D5 are given values for calculations The magnitude of the heat demand for HDW is so high that usually a HDW storage is needed in all systems except district heated buildings

Heat loss calculations Heat losses (or heat demand) of hot domestic water The magnitude of the heat demand for HDW is so high that a HDW storage is needed in all systems except district heated buildings A building with a boiler system, principles of producing HDW part of the heating power from the boiler and part of the power from the storage D5 guidelines: the storage capacity and the loading capacity are calculated for one day (diurnal, 24 hours) and the heat losses of the storage must be taken into account When calculating the total heat demand of the building, only the loading share of the HDW power is taken into account (at the same time as other heat demands occur) The boiler capacity is calculated with Values for η (eta) for each share can be 0,9 if there is no other information Usually in boiler systems some extra capacity is designed ( e.g. two boilers of 400 kW capacity for total heating demand for 650 kW)