The Shashlik Option for CMS B. Cox University of Virginia On behalf of: Baylor, Boston U, UC Davis, Caltech, CERN, ETH Zurich, Fairfield, Fermilab, Florida.

Slides:



Advertisements
Similar presentations
An improvement of radiation hardness of CMS Hadron Endcap Calorimeters under increased LHC luminosity Joint Institute for Nuclear Research, Dubna, Russia.
Advertisements

Roger Rusack – The University of Minnesota
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
CMS Phase 2 Upgrade: Scope and R&D goals CMS Phase 2 Upgrade: Scope and R&D goals October 21, 2014 Jeremiah Mans On behalf of the CMS Collaboration.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
New Calorimeter Technologies for NLC (a) Secondary Emission Calorimeter Sensors (b) Cerenkov Compensated Precision Calorimetry Y.Onel, University of Iowa.
Calorimeters A User’s Guide Elizabeth Dusinberre, Matthew Norman, Sean Simon October 28, 2006.
Update on Quartz Plate Calorimetry Y. Onel HCAL GENERAL MEETING March 27,
1 Tianchi Zhao University of Washington Concept of an Active Absorber Calorimeter A Summary of LCRD 2006 Proposal A Calorimeter Based on Scintillator and.
Status of the PiN diodes irradiation tests B. Abi( OSU), R. Boyd (OU), P. Skubic (OU), F. Rizatdinova (OSU), K.K. Gan (Ohio State U.)
INSTR-08, BINP, Novosibirsk 1 Belle calorimeter upgrade B.Shwartz, Budker Institute of Nuclear Physics Novosibirsk on behalf of BELLE calorimeter.
Status of EIC Calorimeter R&D at BNL EIC Detector R&D Committee Meeting January 13, 2014 S.Boose, J.Haggerty, E.Kistenev, E,Mannel, S.Stoll, C.Woody PHENIX.
Shashlik type calorimeter for SHIP experiment
TOF for ATLAS Forward Proton Upgrade AFP concept: adds new ATLAS sub-detectors at 220 and 420 m upstream and downstream of central detector to precisely.
Roger Rusack – The University of Minnesota 1.
Status of Projectile Spectator Detector A.Kurepin (Institute for Nuclear Research, Moscow) I. Introduction to PSD. II. Conception and design. III. Development.
R&D on W-SciFi Calorimeters for EIC at Brookhaven E.Kistenev, S.Stoll, A.Sukhanov, C.Woody PHENIX Group E.Aschenauer and S.Fazio Spin and EIC Group Physics.
Shower Containment and the Size of a Test Calorimeter Adam Para, September 6, 2006.
Study of Sampling Fractions Shin-Shan Yu, A P, Hans Wenzel, October 18, 2006.
CMS Hadronic Endcap Calorimeter Upgrade Studies
Valery Dormenev Institute for Nuclear Problems, Minsk
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
CMS ECAL Laser Monitoring System Christopher S. Rogan, California Institute of Technology, on behalf of the CMS ECAL Group High-resolution, high-granularity.
Hadron Calorimeter HCAL-J GEp Electron Calorimeter BigCal Hadron Calorimeter 1 G. Franklin, Carnegie Mellon University 10/13/2011.
HE CALORIMETER DETECTOR UPGRADE R&D Y. Onel for University of Iowa Fairfield University University of Mississippi.
E. A. Albayrak, HCAL Meeting, Fermilab, Nov HE CALORIMETER DETECTOR UPGRADE R&D STATUS E. A. Albayrak for The University Of Iowa Fairfield University.
LHC The Large Hadron Collider (LHC) is an accelerator with 27 km circumference. Being built on the France- Switzerland border west of Geneva. It will start.
Quartz Plates R&D Status By F. Duru, S. Ayan, U. Akgun, J. Olson, Y. Onel The University Of Iowa V.Podrasky, C. Sanzeni, D.R.Winn Fairfield University.
Photon Detector with PbWO 4 Crystals and APD Readout APS “April” Meeting in Denver, CO on May 4, 2004 presented by Kenta Shigaki (Hiroshima University,
Concept of NA62 IRC based on PWO scintillation crystals A.Fedorov, M. Korjik, A. Lobko Institute for Nuclear Problems, Minsk, Belarus A. Kourilin JINR,
The Prototype Simulation of SDHCAL Ran.Han Gerald.Grenier Muriel.Donckt IPNL.
Calorimeters Design Issues and Simulation Needs C.Woody Physics Department Brookhaven National Lab EIC Simulation Workshop Oct 9, 2012.
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
PbWO 4 crystals Calorimeter Liping Gan University of North Carolina Wilmington.
PPAC Jonathan Olson University of Iowa Thesis Defense 8 April 2005.
1 Status of Zero Degree Calorimeter for CMS Experiment O.Grachov, M.Murray University of Kansas, Lawrence, KS A.S.Ayan, P.Debbins, E.Norbeck, Y.Onel University.
Roger Rusack – The University of Minnesota Upgrades to the CMS detector.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
I nstrumentation of the F orward R egion Collaboration High precision design ECFA - Durham2004 University of Colorado AGH University, Cracow I nstitute.
PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004.
Ilhan TAPAN* and Fatma KOCAK
Mu2e crystals qualification
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
Particle Identification (PID) at HIEPA Experiment
Scintillation Detectors in High Energy Physics
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
IOP HEPP Conference Upgrading the CMS Tracker for SLHC Mark Pesaresi Imperial College, London.
Results achieved so far to improve the RPC rate capability
Frontier Detectors for Frontier Physics
CMS plans for Endcap Calorimetry at HL-LHC
NRC Kurchatov Institute, ITEP I. Korolko, M.Prokudin, Yu.Zaitsev
standard THGEM versus FLOWER
SiD Calorimeter R&D Collaboration
superB Detector Workshop I University of Perugia and INFN
Radiation Damage Studies for Solid State Sensors Subject to Mrad Doses
Explicitly Radiation Hard Fast Gas Cerenkov Calorimeter
HE Calorimeter Upgrade Studies
Radiation Damage Studies for Solid State Sensors Subject to MRaD Doses
CMS ECAL Calibration and Test Beam Results
Alternative CEPC Calorimeter
Overview on calorimetry R&D for FACTOR (Messina/Trieste/Udine approach) (V. Bonvicini et al.) A. Penzo (June 4, 2008)
Study of a Scintillating Digital Hadron Calorimeter Prototype
Calorimeter Backgrounds
Calorimeter technology
νe flux prediction = e+ counting
General Introduction to IFR
LC Calorimeter Testbeam Requirements
Presentation transcript:

The Shashlik Option for CMS B. Cox University of Virginia On behalf of: Baylor, Boston U, UC Davis, Caltech, CERN, ETH Zurich, Fairfield, Fermilab, Florida State, INFN (Milano-Bicocca, Roma1, Torino, Trieste), IHEP(Beijing), IHEP(Protvino), INP (Minsk, Moscow, Tashkent), Iowa, JINR Dubna, Kansas State, KIPT Kharkov, ISMA Kharkov, Maryland, MEPHI Moscow, NCPHEP Minsk, Northeastern, Notre Dame, Princeton, Rochester, Saclay, Saha Institute of Nuclear Phys., SINP Kolkata Institute, Texas Tech, TIFR Mumbai Institute, Virginia The Shashlik Collaboration B. Cox

2 The Need for new CMS Endcaps It became obvious (due to the work of the CMS FCAL group, predecessor of the Shashlik group) in the time period that the PbWO 4 endcaps would not survive to the stated goal of an integrated luminosity of 3000 fb -1 for the Phase II operation of the CMS detector in the decade of the 2020’s. The left hand plot shows the actual experience to date of the endcap light loss and the right hand plot has a simulation of the loss of Higgs  mass resolution (  ) as a function of eta and integrated luminosity.

B. Cox The CMS FCAL group, after they determined that the PbWO 4 endcaps would not survive to 3000 fb -1 was charged with developing a endcap solution that would survive Phase II and, in addition, do as well or better for photon (and diphoton) resolution as the undamaged PbWO 4 electromagnetic endcap. do no worse than the present hadronic HCAL endcap on hadrons. Starting with this charge, three different options were investigated in a “downselect” process which resulted in two options selected for a final downselect: The Shashlik option (light based option) The HGC option ( electrical based option) This talk will describe the Shashlik Option Charge to the CMS FCAL Group (circa 2010)

B. Cox Requirements imposed by the Charge on the endcap calorimetry Radiation hardness of all components of the calorimeter to integrated particle fluxes of a few X /cm 2 Detector speed (fast scintillation of detector material and waveshifters) Ability to deal with pileup (minimize shower size with high density of detector material) Sufficient light light output to minimize stochastic contribution to resolution Avoid major issues that would lead to systematic contributions to the constant term; maintain its level to 1% or less.

The solution: the Shashlik Option: An Optical Calorimeter Radiation hardness 1.Use of dense materials 2.Small Molière Radius 3.Rad-hard materials 4.Short optical paths 5.Rad-resistant, small pixel photosensor B. Cox LYSO(Ce) – High Brightness – Slowly degrades with dose – Blue/Violet emission WLS Capillaries – Liquid cores accommodate various WLS materials – Spectral matching straightforward – Sealed and Replaceable Photosensors – GaInP if proximate position – SiPM, small pix, cooled in a more remote location Shashlik style module configuration Transverse size of modules ~ ½ Swiss Franc Technologies chosen

The Shashlik Option as proposed for CMS Endcap Region Elevation viewView from the IP B. Cox ~30,500 LYSO/W modules per endcap

Expected Shashlik EM Energy Resolution from GEANT4 + SLitrani B. Cox As a function of eta the LYSO/W Shashlik has excellent photon resolution and is relatively invulnerable to radiation damage A series of tests at CERN in the H4 electron beam undertaken in to validate the resolution expectations

Shashlik 4x4 H4 Beam Test June 2016 (a complete test of the actual Shashlik modules) B. Cox W/LYSO Shashlik Prototype of 16 modules: 28 W plates 2.5mm thick 29 LYSO Plates 1.5mm thick 64 WLS Capillaries: 1mm dia, DSB1 WLS Monitoring Fiber 0.9mm dia Holes drilled in LYSO Plates/No polishing Readout SiPM (10μm pixels, adjustable PDE = 7-25%) Fermilab PADE Boards (Preamp/Digitizer) Total 64 channels 10 million electrons accumulated At 20, 50, 100, 150, 200 GeV in the CERN H4 test beam BEAM

Basic Capillary Structure See poster on capillaries August 6, 18:00-20:00, Riverwalk A/B ( B. Cox Core Blocking Thermal Expansion Reservoir Diffusive Reflector (DR) Surface Coating just before the Reservoir 180 mm Readout End Rad Hard Quartz (Polymicro QA): OD:ID = 1mm:0.4mm 9 Photons wavelength shifted from 425 nm to 550 nm in DSB1 core and transported in the rad had quartz outer cylinder to the SIPMs. No photon travels far in rad vulnerable materials

GaInPSmall Pixel SiPM B. Cox Photosensor Choices Pixels: 5, 7.5, 10, 12um Operate cooled (down to -30c) to increase rad hardness Nearby or remote placement Experience with SiPM and multiple vendors Vendors: FBK, HPK… Pixels: 5um, 10um Can operate at ambient temperature because of good rad hardness Radiation hard due to large band gap Can be placed at the LYSO module Vendor: LightSpin 4x4 mm 2 GaInP light sensor 10 arrays of 0.5x1.5 mm µm pixels GaInP

Preliminary Resolutions from the October, 2014 and June, GeV H4 Electron Beam Tests B. Cox Capillary resolutions are to be considered as preliminary and upper limits but even so are equivalent to Y11 fiber resolutions. Further Analysis in Progress.

Radiation Study: Irradiation Study at LANL of a LFS(LYSO)/W/Capillary Shashlik Module B. Cox

Shashlik Time Resolution with SiPM W/LYSO/DSB1 WLS B. Cox Timing resolution improves with faster rise time. Achieving around 60ps for single capillary / SiPM (similar to Y11). Combined performance < 50ps for a single Shashlik cell. Further studies needed to understand if other limiting factors emerge. Dots: DSB1 fiber WLS Squares: Capillaries with DSB1 WLS

Future radiation testing upcoming to further quantify radiation hardness of key elements of the Shashlik technology Specific aspects of the R&D are potentially applicable to CMS Phase II upgrade and s other experiments Small pixel SiPM and GaInP photosensors WLS and Scintillator R&D Fast timing capability with LYSO and DSB1 We will present future results obtained to the broader scientific community (at CPAD, IEEE/NSS, APS) in the next several months. Papers are in preparation B. Cox Summary Conclusion: The Shashlik was a viable option for CMS endcap calorimetry and is interesting for other experiments

BACK UP B. Cox

Radiation Studies: LYSO(Ce) Crystal Plates B. Cox LYSO characteristics Bright (200 times PbWO 4 ) Decay time (40ns) Radiation damage to LYSO does not recover, leading to a stable calorimeter with slow degradation. Gamma and proton induced absorption coefficient is about 3m -1 for a dose of 150Mrad or 3 x p/cm 2. This leads to a robust calorimeter with a few percent light output loss at HL-LHC.

Radiation Induced Absorption in LYSO B. Cox

Radiation Studies II: Light Collection losses due to radiation for a Capillary (425 nm light shifted to 500nm by DSB1 waveshifter) B. Cox Relative Light Yield Distance from LED to Photosensor (mm) Mrad/0Mrad 100Mrad/0Mrad 150Mrad/0Mrad 200Mrad/0Mrad 18 Good Longitudinal uniformity

Shashlik 4x4 H4 Beam Test ( ) B. Cox W/LYSO Shashlik Prototype of 16 modules: 28 W plates 2.5mm thick 29 LYSO Plates 1.5mm thick WLS Fibers: Kuraray 1.2mm dia, Y11 Monitoring Fiber 0.9mm dia Holes drilled in LYSO Plates/No polishing Readout both Upstream and Downstream SiPM (15μm pixels, PDE = 20-25%) Fermilab PADE Boards (Preamp and Digitizer) Total 128 channels