The Ludlum Project Advisors: Dr. Randal Ruchti, Dr. Dan Karmgard Mark Vigneault Teacher: Mark Kirzeder Students: Kristen Anderson Mengwen Zhang.

Slides:



Advertisements
Similar presentations
Analysis of the Optical Properties of Organic Liquid Scintillator in LENA DPG-Tagung in Heidelberg M. Wurm, T. Marrodán Undagoitia, F. v. Feilitzsch,
Advertisements

Sound and Light CHAPTER 15. All sound waves  Are caused by vibrations.
Double Chooz: Outer Veto
COSMIC RAY MUON DETECTION USING SCINTILLATION COUNTER AND WAVELENGTH SHIFTING FIBERS ARUNODAYA BHATTACHARYA VSRP-2009,TIFR,MUMBAI 6/7/09.
Collaboration Meeting, Oct : Start Counter Start Counter Eric Pooser W. U. Boeglin L. Guo P. Khetarpal Experimental Setup SiPM Scan Attenuation Lengths.
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
The performance of Strip-Fiber EM Calorimeter response uniformity, spatial resolution The 7th ACFA Workshop on Physics and Detector at Future Linear Collider.
The Detection of Radioisotopes Using a Thin Scintillating Fiber in a Spiral Adam Jernigan and Eric Blue Advisor: Dr. Thomas Dooling The University of North.
1 Cosmic Ray Test Stand with Scintillating Cells for Digital Hadron Calorimeter 06/23/2003 Kurt Francis - Northern Illinois University.
A Muon Veto for the Ultra Cold Neutron Asymmetry Experiment Vince Bagnulo with Dr. Jeff Martin Electrons Ultra Cold Neutrons Cosmic Ray Muons Protons Pions.
Radioactivity – review of laboratory results For presentation on May 2, 2008 by Dr. Brian Davies, WIU Physics Dept.
ConcepTest #65 Consider the following graph of a wave function for a particle. a) At what point(s) are you most likely to find the particle? Hold up as.
Fiber Attenuation Length Test for MINERvA Jaewon Park University of Rochester Jupiter/MINERvA Meeting, Sep 10, 2005.
Cosmic Ray Test Stand with Scintillating Cells for Digital Hadron Calorimeter As of 9am 05/28/2003.
STUDY OF AMPLIFICATION ON ERBIUM DOPED FIBER AMPLIFIER Lita Rahmasari, Assoc. Prof. Dr. Yusof Munajat, Prof. Dr. Rosly Abdul Rahman Optoelectronics Laboratory,
Sep 13, 2007CALICE Collaboration Meeting Prague 1 Long term test of LED pulsing  Long LED system stability measurement  Aging of part of optical system.
CMS UPGRADE CAPILLARY TUBE PROFILING. CAPILLARY TUBES EVALUATION Radiation damage Transmission Mixing Scintillating Quartz Tube Water/ Air EJ309 Fiber.
1 HF Laser/LED Calibration Studies L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH 1->9 light splitter w/ pulsed.
LIGO-G Z D. Ugolini, Charging Workshop July UV Illumination Studies at Trinity University Dennis Ugolini, Mark Girard 2007 Workshop on.
Cosmic Ray Muon Detection Department of Physics and Space Sciences Florida Institute of Technology Georgia Karagiorgi Julie Slanker Advisor: Dr. M. Hohlmann.
Neutron Generation and Detection Lee Robertson Instrument & Source Division Oak Ridge National Laboratory 17 th National School on Neutron and X-ray Scattering.
HCAL Laser Upgrade Study German Martinez Florida International University Vasken Hagopian Florida State University.
Trend ground array 1 1.General considerations 2.Study on the prototype detector 3.Inclined ground array simulation 4.Making work plan in 2014.
PEPPo Weekly Meeting February 23, 2011 PEPPo Electromagnetic Calorimeter First measurements Jean-Sébastien Réal, Eric Voutier Laboratoire de Physique Subatomique.
Wave Nature of Light Physics Group: Alex Pearson, Travis Christolear, Mei Mei Chan, Colin Smith Faculty Advisors: Vladimir Gasparyan, Thomas Meyer Experimental.
LED calibration systems for CALICE hadron calorimeter Jiri Kvasnicka Institute of Physics, Prague June 11, 2011TIPP 2011, Chicago1 Under.
Construct two layers of hadron calorimeter and test Makoto Harada High Energy Physics Laboratory Faculty of Physics Department of Science Shinshu University.
QuarkNet Muon Data Analysis with Shower Array Studies J.L. FISCHER, A. CITATI, M. HOHLMANN Physics and Space Sciences Department, Florida Institute of.
Measurement of 'intrinsic' properties of scintillating fibers H. Sakamoto Osaka University, Japan A.Sato M. Yoshida Y. Kuno Osaka Univ. K. Yoshimura KEK.
LMS Stability, Data Correction and the Radiation Accident within the PrimEx Experiment by LaRay J. Benton M.S. Nuclear Physics May 2006 Graduate North.
N 2 Laser 300  QQ 150m HF  HF + 9 PMT Boxes  QP Calib Box 1  4 Counting Room HF Calibration Optical Fiber Path 9 PMT Boxes / Quad 24 PMT Tubes.
March 12, 2006R. Abrams LCWS06 Bangalore1 ILC Prototype Muon Scintillation Counter Tests Robert Abrams Indiana University.
Fig. 3 Wind measurements experimental setup Lidar (light detection and ranging) operates using the same concept of microwave RADAR, but it employs a lot.
1 Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH.
Optical Part of the CMB for AHCAL-CALICE Jaroslav Zalesak Institute of Physics, Prague.
EODU, Mixers and Plans for 2012 B. Baumbaugh, C. Broughton, C. Burke, J. Conti, K. Daily, J. Freeman, A. Heering, D. Karmgard, S. Los, J. Marchant, M.
H. Dauerty Attracting HS Student Participation in HEP AAPT Meeting 11 Ja2001nuary Attracting High School Student Participation in Particle Physics Research.
E. A. Albayrak, HCAL Meeting, Fermilab, Nov HE CALORIMETER DETECTOR UPGRADE R&D STATUS E. A. Albayrak for The University Of Iowa Fairfield University.
PCAL Strips light transmission properties April 25, 2011April 26, 20111April 27,
1/10/2016Collaboration Meeting Feb 2011 Start Counter 1 Start Counter Update W. U. Boeglin L. Guo E. Pooser Measurements on EJ-212 scintillator bars Attenuation.
1 P.Rebecchi (CERN) “Monitoring of radiation damage of PbWO 4 crystals under strong Cs 137  irradiation in GIF-ECAL” “Advanced Technology and Particle.
Linearity Tests The laser induced high noise pulses on the APD rendering it useless. We tried several methods to shield and filter the noise. With a stabilized.
PMT-RAS. Turning the Clean Room Into a Dark Room.
The Ludlum Project Scintillating and wave shifting fibers.
Christopher Cowden Advisor: Mario Spezziga Project: CMS HF (Forward Calorimeter)
Scintillator and Fiber Test Measurements with Gluing Clas12 upgrade pcal user group May 13, 2009 Clas12 upgrade pcal user group May 13, 2009 Dustin Keller.
FORWARD ATLAS {major contributions from Per Grafstrom (CERN), Michael Rijssenbeek (Stonybrook), Brian Cox (Manchester} Andrew Brandt Luminosity measurement.
M EASURING L IGHT G UIDE P ERFORMANCE IN L IQUID A RGON Jarrett Moon Massachusetts Institute of Technology FNAL New Perspectives – 6/9/15.
Preliminary results from the attenuation scans in BGO crystal. 1 F.Lacava CERN
Lab: Linear Motion Experimental Procedure:
PS Timing & Alignement Progresses 17 April 2008 LPC Clermont.
Date of download: 9/19/2016 Copyright © 2016 SPIE. All rights reserved. Phase-dependent probe amplitude in the continuous wave regime. The blue line is.
H.E. Fisk, A. Meyhoefer, A. Para, E. Ramberg, P. M. Rubinov Fermilab
Lab: Linear Motion Experimental Procedure:
GCSE (1-9) Physics: Radioactivity Nuclear Decay and Half Life
CLAS12 Forward Detector Element PCAL
Cavity Ring-Down Spectroscopy
Instrumentation for Colliding Beam Physics 2017
The Life and Times of Cosmic-ray Muons
MFM setup. MFM setup. The excitation lasers are combined in a fiber through an acousto-optic tunable filter, collimated, reflected on a dichroic mirror.
Equipment Tests for DHC Tower
Notre Dame QuarkNet Center D. Wiand
Efficiency Study of Prototype Scintillator for INGRID
Notre Dame QuarkNet Center D. Wiand
PHYS 3446 – Lecture #16 Particle Detection Silicon Photo-Multipliers
Objectives Write the standard equation of a parabola and its axis of symmetry. Graph a parabola and identify its focus, directrix, and axis of symmetry.
Volume 104, Issue 1, Pages (January 2013)
Vision A community of researchers including faculty, postdoctoral, graduate and undergraduate students and high school teachers and high school students.
University of Sheffield
The Development of a Segmented Detector using ZnS:Ag/6Li
Presentation transcript:

The Ludlum Project Advisors: Dr. Randal Ruchti, Dr. Dan Karmgard Mark Vigneault Teacher: Mark Kirzeder Students: Kristen Anderson Mengwen Zhang

History of Notre Dame  Ongoing  Ludlum Measurements Inc.  In the past, separate wave shifting and scintillating materials were used in combination with one another.

 Current experiments are focused on materials that are manufactured with both properties in a single fiber. Old 3HF New 3HF OX-550F 4CN-HBT Current Focus of ND

Current Goals of Ludlum  The goal of the project is to find a material that can be used in new particle detectors.  Several methods have been developed in the past and are in use at FermiLab and CERN currently.

Factors Tested This Summer  Brightness How much light is transmitted along the fiber  Decay Time How much time passes between excitation and relaxation of molecules in the fiber  Attenuation Length How long can a fiber be before light begins to escape

Test – Scintillation  Used to test all three factors

Experiment Set Up within a light tight box Sr 90 Fiber PMT Counter Paddles Brass plate Apiazon Radioactive source Data PMT

Experiment Set Up Optical fiber Bronze plate Radioactive source Time- gate paddles

Data Gathering  Two paddles are used as triggers  Brass plate shields  Radioactive source  Data is stored on an oscilloscope  2048 data points per run - averaged  6 or more runs per graph - averaged  Several distances from source to PMT

Data Gathering

Calculating Brightness  Brightness is a measure of how much light the fiber transmits  Integration yields total light Several integrations completed

Calculating Brightness Average brightness is 1021 units at 1.5 m.

Calculating Decay Time  Used for comparative analysis.  90% - 10% of curve used  A best fit exponential or semi-log plot  2.93m magic number

Calculating Decay Time

Decay time = 1 / c =18.35ns

Calculating Attenuation Length  L out = L in * exp (-x / Attenuation Length)  Attenuation length is the distance at which 1/e of the original light remains  Light out data was gathered at 1.0m, 1.5m, 2.0m, 2.5m, and 2.93m  Incomplete data set

Calculating Attenuation Length Attenuation Length = 1 / c =4.96m

Test – LED Attenuation  A new test  UV LED’s 395nm and 405nm Quicker Easier

Test – LED Attenuation  Failures Inconsistent data Unexpected results  Success Development of sound data analysis techniques Improvement of experimental techniques

Experimental Set Up within a light tight box Sr 90 Fiber Apilazon LED Photo Diode

Experimental Set Up Fiber LED Photo Diode

Calculating Attenuation Length Attenuation Length = 1/c = 3.00m

Calculating Attenuation Length Attenuation Length = 1/c = 4.74m

Conclusions  Preliminary results indicate New 3HF is the brightest fiber 4CN-HBT has shortest decay time 4CN-HBT has the longest attenuation length  The nature of future experiments will dictate which fibers will be used There may not be one perfect fiber