Group names  أبوبكر عبد المعز & عبدالله سلامه. Circuit breakers  Circuit breakers are be considered one of the most important component in power systems.

Slides:



Advertisements
Similar presentations
Seminar on Circuit Breaker
Advertisements

Medium-Voltage Switchgear - Then and Now -
Detail Discussion on Different type of Circuit Breaker
CIRCUIT BREAKERS.
1S25 Arc Fault Monitor. 1S25 Arc Fault Monitor 1S25 Arc Fault Monitor Electrical arc short circuits in metal clad switchgear may occur for many different.
Inspection & Preventive maintenance of breakers
Fuses vs Circuit Breakers for Low Voltage Applications
During fault behavior of circuit breaker
2. Circuit Breakers and Recloser
WHAT IS A CIRCUIT BREAKER
Prepared by Kazi Md. Shahiduzzaman Circuit Breker.
Introduction to Plasma Processing SF 6 Circuit Breaker Student: Hosny, Ahmed A. Instructor: Prof. Kasra Etemadi.
SWITCHYARD
INTRODUCTION TO SWITCHGEARS
Circuit Breakers.
CIRCUIT BREAKER.
By R. Vijay Krishna. CONTENTS  INTRODUCTION  WORKING PRINCIPLE OF C.B  TYPES OF CIRCUIT BREAKERS  SF6 CIRCUIT BREAKER.
SEMINAR REPORT ON SF6 CIRCUIT BREAKER
Circuit breakers The main purpose of a circuit breaker is to: Switch load currents Make onto a fault Break normal and fault currents Carry fault current.
SEMINAR REPORT ON SF6 CIRCUIT BREAKER BRANCH-EEE.
Transformer Taking the ratio of the two equations
CIRCUIT BREAKER Definition  Device designed to open the circuit automatically under abnormal conditions without damage to itself.
Welcome to Electric Dept. Rajkot Division. How MCB works.
Sulfur Hexafluoride (SF6) Gas Handling. Description Sulfur hexafluoride (SF6) in its pure state is inert, nontoxic, odorless, nonflammable and colorless.
Electrical Safety and Electrical Safe Work Practices EHS Course #525 Reference EHS Electrical Safety Procedure
SEMINAR REPORT ON “GAS INSULATED TRANSFORMER”
Introduction to switchgears
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
Submitted to: Submitted by:
Air Blast Circuit Breaker
Department of Electrical Engineering
Prepared by : M.Azeem Zahid
220 KV GRID SUB STATION MORAK,KOTA SUBMITTED TO:- SUBMITTED BY:- SHRI VIKAS BHALLA LAKHAN SINGH ASSISTENT PROFESSOR ROLL NO.-12ECTEE029 ELECRTICAL DEPARTMENT.
VACUUM CIRCUIT BREAKER. WHAT IS A CIRCUIT BREAKER A circuit breaker is an equipment that breaks a circuit either manually or automatically under all conditions.
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
By: Chandramohan S. Jha Class :- 7 th EE Roll no :- 26.
1. كليدهاي فشارقوي 2 DS CB 3 كليدهاي فشارقوي ـ يكي از اصليترين اجزاء سيستم ‌ هاي انتقال و توزيع به منظور : ـ قطع و وصل خطوط ، ترانسها ، ژنراتورها و.
  The traditional molded-case circuit breaker uses electromechanical (thermal magnetic) trip units that may be fixed or interchangeable.  An MCCB provides.
Jeudi 7 juillet 2016 ELECTRICAL. 2 INTRODUCTION: SINGLE PHASE INDUCTION MOTOR: TYPES OF SINGLE PHASE INDUCTION MOTOR: 1)Shaded Pole(Very Small Motors)
Mahakal Institute Of Technology Ujjain(mp) Seminar on circuit breakr Submitted to :Submitted by : Prof. sonali pandey pooja rathore.
SEMINAR PRESENTATIon ON C IRCUIT B REAKER DEPT. OF ELECTRICAL ENGG. JALPAIGURI GOVT. ENGG. COLLEGE PRESENTED BY Madhusudan Mahato Malay Ghosh.
By:- Abhishek Bhardwaj IV year VIII sem Roll NO.– four(04)
SEMINAR REPORT ON SWAGATIKA SAHOO REG NO:
ETP 2161C Week #1 HV Power Circuit Breakers (Text book ref.) This course will refer to the following text book, chapter and page #. Power Line Worker:
Electrical Safety and Safe Work Practices
UNIT-5. ELECTRICAL SAFETY, WIRING & INTRODUCTION TO POWER SYSTEM
Install protection equipment
IDENTIFYING SYMPTOMS OF SURPRISE ELECTRICITY (ELECTRIC SHOCK)
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
Development of The SF6 Circuit Breakers
Circuit Protection Unit 9.
High Voltage Engineering Insulation: Liquid dieletrics
CIRCUIT BREAKER presented by: M Aamir sohail khan & sufyan saleem Dept, of electrical engineering bahaudain.
AIR CIRCUIT BREAKER.
Oil circuit breakers.
Switching transient phenomena
Circuit Breakers & Reclosers
Do’s and Don'ts of SF6Gas Handling
Air Circuit Breaker This type of circuit breakers, is those kind of circuit breaker which operates in air at atmospheric pressure. After development of.
FAULTS.
High Voltage Power Circuit Breakers
ELECTRICAL POWER-II Electrical engineering sixth semester
Sulfur Hexafluoride (SF6) Gas Handling
SWITCH GEAR AND PROTECTION(IV-1) TOPIC-CIRCUIT BREAKER
CIRCUIT BREAKER presented by: M Aamir sohail khan & sufyan saleem Dept, of electrical engineering bahaudain.
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
By LCdr NS Wickramasinghe BSc Hons (E & E Eng) MSc (HRM) AMIE (I) AMIE (SL) C Eng (I)
0 Air Blast Circuit Breaker under the guidance of:- Presented By:- Mr. B.R.Reddy Anuj Kumar Pandey EN-3 rd year Roll No Unrestricted.
Substation Equipment's
Fuses vs Circuit Breakers for Low Voltage Applications
Presentation transcript:

Group names  أبوبكر عبد المعز & عبدالله سلامه

Circuit breakers  Circuit breakers are be considered one of the most important component in power systems.  Circuit breakers are used to protect the power systems from any fault like short circuit or overload current.

Operating Principle Two contacts called electrode remains closed under normal operating conditions. When fault occurs on any part of the system, the trip coil of the circuit breaker get energized and contacts are separated.

Arc Phenomenon  An arc is struck when contacts are separated. The current is thus able to continue. Thus the main duty of a circuit breaker is to distinguish the arc within the shortest possible time.  The arc provides the low resistance path to the current and the current in the circuit remains uninterrupted.

1-oil circuit breaker

Consists of two parts. Supporting Chamber. Circuit-Breaking chamber( consist of fixed and moving contact)

Disadvantages Of Oil Circuit Breaker  It is inflammable and there is a risk of fire.  It may form an explosive mixture with air.  It requires maintenance.  Absorbs moisture, so dielectric strength reduces.  Oil leakage problem.  Oil has to be replaced after some operations because of the carbonization of oil.

Vacuum Circuit Breaker  Vacuum is used as an arc quenching medium.  Have greatest insulating strength.  to pressure is to be maintained.  Used in 11KV panel in control room of grid station.

Advantages  Compact, reliable and have longer life.  No fire hazards.  No generation of gas during and after operation.  Can interrupt any fault current.  No noise is produced while operating.  Require less power for control operation.

SF6 Circuit Breaker 1. Sulphur Hexafluoride (SF6) gas is used as an arc quenching medium. 2. SF6 is an electro-negative gas. 3. It has strong tendency to absorb electrons. 4. When contact are opened in a high pressure flow of SF6 gas, arc produced. 5. Free electron in the arc are captured by the gas. 6. Which build up enough insulation strength to extinguish arc. 7. it is much effective for high power and high voltages services,

Advantages  Simple construction, less cost.  SF6 gas is non flammable, non toxic & chemical inert gas.  Same gas is recirculated in the circuit.  Maintenance free C.B.  Ability to interrupt low and high fault current.  Excellent Arc extinction.