Criticality measures Low  General annoyance – screen stops working, buttons don’t work  λ < 10 -5 High  Parts get hot, catch fire, and/or explode 

Slides:



Advertisements
Similar presentations
A/C Generator Systems.
Advertisements

38GXC(Q)/40GXC(Q) Service Training Sizes 18 and 24K.
Josh Piron, Jacob Pfister, Kevin Templar, Mike Phillips Group Nine Reliability and Safety Analysis DART.
RELIABILITY & SAFETY ANALYSIS PRESENTED BY: ANDREW BATEK Team # 15: Acoustic Storm Interweaving the impressive visual power of electricity and the visceral.
Team 13 John Ashmore, Brian Bell, Jason Giles, Jing Li.
MARCELO L. BRANDON G. ADITYA B. NIKHIL S. THE INCREDIBLE HUD.
TEAM BRIGHTRIDERS Failure Modes, Effects, and Criticality Analysis “We put the SOUL in SOULAR racing”
Defender Safety and Reliability Analysis Kirk Iler Brian Bentz Stephen Wolf Fuhe Xu.
Daryl SielaffBen McQuiston Will McKennaDavid Hartman Functional Blocks and FMECA Chart.
Team 01 : QuadSquad Safety and Reliability Andrew Boldt 11/6/2013 the ECE quadcopter senior design Purdue University1.
Technical Communication Skills Practicum (TCSP) Presented by Nuhairi & Azad Team 10: “Hazard Rover” 2/21/2007.
o Portable low-cost aerial drone that can be used for reconnaissance o Relay real-time video and data, like location, heading, battery life o Take high-resolution.
Team 2 Yimin Xiao Jintao Zhang Bo Yuan Yang.  The project we propose is a digital oscilloscope with playback function that provides almost any function.
Technical Communication Skills Practicum (TCSP) Presented by Nuhairi & Azad Team 10: “Hazard Rover” 2/21/2007.
Kian Hui Wong Chia Siong Goh Wan Qi Choo Jun Jun Peh Presenter: Kian Hui Wong.
ECE 477 Group 3 The Gauntlet George Hadley Kelli Hacker Sean Ma Jacob Champion.
Team 3 Humphrey's Treasure Chest Roy Scheck Tony Leichty Charles Lan Steve Kingsley.
ECE 477 Design Review Team 6  Spring 2006 Greg Snow Allan Patterson Kyle McGhee Joseph Davidson.
Group 11. CriticalityFailure EffectMax Probability HighInjury to user may occur. LowLoss of some or all functions of the device. Customer dissatisfaction.
Team 13 Michael Stuckenschneider Loren Garby Arin Chakraverty Janell Niekamp.
TCSP – Reliability and Safety. Reliability Analysis Major component chosen for analysis:Major component chosen for analysis: Switching Regulators (LM2679SD-5.0,
Group 12 – H.E.A.D Gear Maximum Power Point Tracker Reliability and Safety Analysis Harsha Eric Atandra Daniel Vengapaty Aasen Burman Da Silva.
Solar Telematics System
Madalina Vintila David Wilkinson Michelle Zhang Zac Greenawalt.
Smart Game Management Mike Moninski James Brown Shawn Ironmonger Daniel Moore.
Team 9 - Scribacious Rabble Safety and Reliability Analysis Mitchell Erdbruegger (presenting) Paul Rosswurm William Hess Ben Kobin.
RCD Laser System Corey Lane, Ryan Scott, Danny Barjum.
Grant Thomas Anthony Fennell Justin Pancake Chris McCord TABLEGAMES UNLIMITED.
ALEX BUSCHKOETTER ALEX GLENN KIMBERLY SOONG PETRA MUSTAFA Group 4: 3MS.
FLAC Audio Player Brett Mravec with Isaac Jones Greg McCoy Danielle Miller Team 9.
Alex Wanamaker.  2 astable 555 timer circuits  Blinking rate: ~1.1 seconds  Q1 and Q2 used to provide additional current for the circuit beyond.
Matt Waldersen (Presenting) TJ Strzelecki Rick Schuman Krishna Jharjaria.
The “Drink Mixer” Reliability and SafetyAnalysis.
Technical Communications Practicum: Failure Modes, Effects and Criticality Analysis SmartShopper Jeff Richards, John Sweeney, Stevi Wood and Tera Wong.
FEST ECE 477 Fall 2011 TEAM 5 Gloria Budiman Alexander Kidarsa Christopher Sakalis Vishal Gala.
Team 5 Reliability & Safety TCSP. High Criticality = λ < Low Criticality = λ < High Criticality determined by constant vehicular movement.
Wall-E Prototype I TCSP #8 Safety and Reliability Analysis Team 1 Xin Jin Ranmin Chen Hang Xie Zelun Tie.
Chapter 6 Lesson 2. How can electricity flow? When an object gains of loses electrons, it has an electric charge. Similar to magnetic force, unlike charges.
Home Enhancement Suite Presenter: Allen Humphreys William Bouchonnet, Daniel Sabo, Nathan Irvin.
Steve Andre Eric Glover Shaun Greene Russell Willmot.
Technical Communication Skills Practicum (TCSP) Presented by Team 10: “Hazard Rover” 2/21/2007.
Fly Spy – Group 12 Reliability and Safety Analysis Heather Barrett.
Circuits A deeper look into different types of circuits.
Team 3 ATV Daniel Barrett Sebastian Hening Sandunmalee Abeyratne Anthony Myers.
SWISH SLEEVE Safety and Reliability Analysis Stephen MacNeil, Michael Kobit, Sriharsh Achukola, Augustus Hong.
P-REV Michael Connaboy Stephen Schiffli Ram Hudiara Win Than Aung.
FMECA chart April 12, 2006 The J Team Jennifer Tietz Jared Suttles
Team 16 : Project Minotaur Presenter : John Hubberts
By: Katherine Guzman, Manuel Uceta, Mohamed Mosaed
Reliability and Safety Analysis
A deeper look into different types of circuits
Avaya UPS Online Training: Advanced Battery Management
Run Standard Diagnostic Tests
Electricity 7-3 Circuits.
While Driving Why the Car Battery Lights On.
Reliability & Safety Analysis
Process of Debugging a Circuit
ADITYA B. BRANDON G. MARCELO L. NIKHIL S.
Joe Trefilek Jeff Kubascik Paul Scheffler Matt Rockey
ECE477 Team 6: The Soviet Challenge
Team We Ate 9 FMECA Worksheet.
Matt Baker Laura Kassovic Corey Zahner Jason Eaton
Uninterruptible Power Supply
Dong-Han Ryu Yukeun Sim Shiv Biddanda Po-Cheng (Robert) Wang
Safety Analysis Ian Bacon Zach Dicklin Amy Ritter Eric Yee.
Fuses
Reliability & Safety Analysis
ELECTRICAL SAFETY AWARNESS TRAINING
Presentation transcript:

Criticality measures Low  General annoyance – screen stops working, buttons don’t work  λ < High  Parts get hot, catch fire, and/or explode  λ < 10 -9

Battery Pack – “A”

Failure No.Failure ModePossible Causes Failure EffectsMethod of Detection CriticalityRemarks A1Header Output Battery Disconnected, Battery dead, Protection circuit failure Device is inoperable ObservationLow 1 = 0V A2Header Output U19 failure, R74 damaged, Unable to track battery life via uC, in the cases of U19, R74 failure ObservationLow 2 = 0VBattery dead A3Battery Shorted out Traces in battery circuit short out, wiring from battery terminals short out Battery discharges VERY rapidly (Protection circuit keeps from exploding) ObservationHigh A4Header output 1 > 8.4V Protection circuit failure Battery becomes overcharged, can lead to overheating, possibly explosion ObservationHigh

3.3V Regulator – “B”

Failure No.Failure ModePossible Causes Failure EffectsMethod of Detection CriticalityRemarks B1PWR_3.3 < 3.3V U20 failureCircuit becomes underpowered, device is inoperable ObservationLow B2PWR_3.3 > 3.3V U20 damagedOther components in circuit could be damaged by overvoltage ObservationHigh B3PWR_ON+ > 14.4V Short in SW4 between PWR_ON+ and PWR_OFF+, along with a failure of U18 Damage to U20, can lead to B2 happening ObservationHigh

Battery Recharger – “C”

Failure No. Failure Mode Possible Causes Failure EffectsMethod of Detection CriticalityRemarks C1PWR_OFF+ <8.4V Wall Wart disconnected, R76, R75 or, R70 short Battery won’t charge completely ObservationLow C2PWR_OFF+ >8.4V U18 Damaged, short in recharger, R76, R75, or R70 damaged Battery runs the risk of being overcharged if protection circuit has failed ObservationHigh C3Conn Jack Pwr input >21V Power surge from outlet U18 damagedObservationHigh

Compact Flash Circuit – “D”

Failure No. Failure Mode Possible Causes Failure EffectsMethod of Detection CriticalityRemarks D1No transmission from CompactFla sh card CF card disconnected or loose, PWR disconnected, software error TetriNET will not be playable online. ObservationLow

Microcontroller Circuit – “E”

Failure No.Failure ModePossible Causes Failure Effects Method of Detection CriticalityRemarks E1Continual resetting Y1, C26, C27 – problem with the crystal circuit Device will be inoperable ObservationLow E2Timer overflow A game of TetriNET lasts longer than days Code will have erratic effects ObservationLow

Button Circuit – “F”

Failure No. Failure Mode Possible CausesFailure EffectsMethod of Detection Criticalit y Remark s F1Buttons don’t register inputs BTN_SEL not changing, U17 damaged, button wiring loose Device cannot be properly operated ObservationLow

LCD Circuit – “G”

Failure No. Failure ModePossible CausesFailure Effects Method of Detection CriticalityRemarks G1Displays nothing U4/U5 connectors damaged or loose, ezLCD-001 damaged Device cannot be used ObservationLow G2Displays gibberish Software error, ezLCD- 001 damaged, header connections not complete Device unstable or unusable ObservationLow

Reprogramming Circuit – “H”

Failure No. Failure ModePossible CausesFailure EffectsMethod of Detection CriticalityRemarks H1Circuit cannot be reprogrammed U9/U10 damaged or loose Cannot reprogram microcontroller ObservationLow