DIGITAL AC BASED ON GSM TECHNOLOGY Presented By Ravi Shankar PrasadAzeem Ahmad Ashutosh DubeyAnkit Ankit kumarRahul kumar Akshay kumarAnkur kumar Electronics.

Slides:



Advertisements
Similar presentations
GSM Relay Controller. GSM Power Supply Voltage must be between 10 – 14vdc.
Advertisements

SIMCOM MODULE FEATURES
Technical Tips. Getting Started with emPower™ Learn-in your new Z-Wave-enabled Alarm.com module following the same process as before: – Perform a Module.
IP Office Install in Basic Mode Initial Steps. ©2009. All rights reserved. Overview of Process 1. Read all documents sent from Avatel concerning install.
GS3055-I GSM Universal Wireless Alarm Communicator
V900 GSM remote Camera Introduction Digital Imaging Solutions. July
Introduction Mobile Switch is a device which will be helpful to switch on and off any electrical/electronic devices through a SMS. The parameters of these.
GS3055-I GSM Universal Wireless Alarm Communicator
SMS Module Model : SB-DN-SMS/IP Configuration of SMS Module.
Programming Software and Setting. if forget the IP address of SB-DN-1IP, programmer can press the reset button till the led goes red, then it is reset.
GS3055-I Installation Process
HDL-MGSM.431. Description MGSM.431 is an automation module based on GSM monitoring and controlling. Being at a great distance you can operate a target.
目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.
11111 Apollo Internet Monitoring Tutorial Apollo Solar, Inc. 23 F. J. Clarke Circle Bethel, CT (203)
Gsm Modems Based Irrigation Water Pump Controller for Illiterates
Sniffer for Detecting Lost Mobiles
Door Controller Device. 2 Door Controller Device (DCD) The DCD is the “Remote Brains” of the system. It is the controller device located at each access.
Products presentation Security Protecting your home has never been so easy.
Products presentation Security Protecting your home has never been so easy.
S3b Sim Secual Product Training March Connected to your smartphone Communication by SIM card Interact with your system everywhere you are Control.
What does LinkConnect do?
SIMPLE & MODULAR PC BASED DOOR ACCESS CONTROL v1.00
GSM FCT for Emergency Applications
GSM Controlled Robots.
Building Intercom Solution
Poseidon 4002 Rack monitoring.
S4 Combo Secual Product Training March 2016.
NEW RMC Rack Multi Control.
CCNA 2 v3.1 Module 2 Introduction to Routers
WEL COME.
GSM Gateway ARIA TELECOM SOLUTIONS PVT. LTD..
VOICE CONTROLLED SMART HOME AUTOMATION SYSTEM BASED ON ZIGBEE NETWORK
AUTOMATED security system
Multifunctional Sensor
CUT40P training manual March.2011.
Programming and Debugging with the Dragon and JTAG
REMOTE CONTROL OF A MECHATRONICS SYSTEM WITH WIRELESS COMMUNICATIONS
GPRS Troubleshooting.
WIRELESS ELECTRONIC NOTICE BOARD USING GSM
SMS module HDL-MGSM.431.
Arduino Based Industrial appliances control system by decoding dual tone multi frequency signals on GSM / CDMA network. Submitted by:
FLoor Heating Controller
Smart home introduction
Wireless Relay HDL-MPR01-RF.18.
SCADA for Remote Industrial Plant
FLoor Heating Controller
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Telephone Gateway TG/S 3.2
AUTOMATED security system
Wireless 4 Buttons Touch Panel
Microcontroller Based Digital Code Lock
Wireless 3 Buttons Touch Panel
Wireless Relay HDL-MPR02-RF.18.
CCNA 3 v3.1 Module 6 Switch Configuration
BUILDING MANAGEMENT SYSTEMS(BMS)
Remote Controlled Smart Socket
IP-AK2 Access Control Solution
WIRELESS INTERCOM ACCESS.
GSM door opener Model RTU5015 RTU5025 .Different appearance ,the same function.
MINNY 16 TROUBLESHOOTING Doc THE MACHINE DOES NOT START
PHASE IDENTIFICATION UNIT (PIU)
A Quick Start of Your Device - HVT001
Two factor Authentication
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
ACOE347 – Data Acquisition and Automation Systems
【Date: 】
Universal Interrupted Electronic Oil Primary R7184U Training Module
Are you looking for netgear -customer services we are 24X7 to serve you better,netgear -customer services.
Hardware Graduation Project (2) Seminar
How to install a WISE-4051 Device Presented By: Mark Brown
KX-NS Step by Step Guide Initial Setup
Presentation transcript:

DIGITAL AC BASED ON GSM TECHNOLOGY Presented By Ravi Shankar PrasadAzeem Ahmad Ashutosh DubeyAnkit Ankit kumarRahul kumar Akshay kumarAnkur kumar Electronics & Communication Engg,.

INTRODUCTION WAFER GSM-CTL-AC is an electronic board with an on-board GSM modem. The purpose of this device is to do the real time and interactive GSM remote control by means of a GSM phone. GSM-CTL-AC is designed for the industrial remote control project. That can be used to switch on and off the power supply up to 6000W.

DESCRIP TION

ADVANTAGES OF GSM CONTROL AC 2 channels: AC240V 30A 50Hz relay contact and AC240V 12A 50Hz relay contact No call charges to operate from phone calling. DIP Switch to setup the relay working methods. Work with GSM phones calling and SMS. Relay operates almost every applicance.

Remote password operation and also password change. Opetional relay working mode. One relay output with the calling mode and others with the SMS to control Caller ID confirmation for security. Quick & easy number barring. Can be operated from anywhere. Easy programming in minutes with your phone or PC software.

PROCESS OF INCERTING SIM 1.Slide back the SIM door and lift it up 2.Slide the SIM Card into the SIM door making sure that the clipped corner of the SIM card lines up with the clipped corner of the SIM holder 3.Close the SIM door 4.Slide the SIM door to lock the SIM card in place.

GSM-CTL-AC PROGRAMMING On the GSM-CTL-AC board, there is one Red DIP switch, that is used to setup the relay working method. We have two way to control the relay. SMS or phone calling. You have to select one right way as your relay working way. So Firstly need to program the Device with the DIP Switch to setup the relay working mode as the following chart:

COMMAND USED IN GSM-CTL-AC #PWD : Password # CAP : Change password #WHL : White List (add or remove numbers) #GOT: Relay working output delay time #ALARM: Alarm information setting #MODE: Relay mode #CSQ: Check Signal Quality #SCA: Set service center address #STATUS: Check status

TROUBLESHOOTING No LED is on after power up 1. Check the power supply. GSM LED D6 is not flash slowly 1. GSM Signal is not good and can't register to GSM 2. Check the SIM card. 3. Check the antenna connection. 4. Select a place with a good GSM signal. MCU LED is not flash slowly 1. MCU is not working properly, Check the system power

THANKS