1 Chapter No. 9 Measurements and Detection of Radiation, Nicholas Tsolfanadis, 2010, McGRAW-HILL BOOK INTRODUCTION TO SPECTROSCOPY.

Slides:



Advertisements
Similar presentations
EPOCH 1000 Series Software Feature AWS D1.1/1.5
Advertisements

Topic 8. Gamma Camera (II)
Instruments for Radiation Detection and Measurement Lab # 4.
NUCP 2371 Radiation Measurements II
Lab B4: The Creation and Annihilation of Antimatter SFSU Physics 490 Spring 2004 Professor Roger Bland.
Constructing an Analog Digital Converter (ADC) to Measure Neutron Depolarization in Deuterium Aung Kyaw Sint and Dr. Alexander Komives CsI scintillator.
Analog-to-Digital Converter (ADC) And
Gamma-Ray Spectra _ + The photomultiplier records the (UV) light emitted during electronic recombination in the scintillator. Therefore, the spectrum collected.
Copyright © 2010, 2007, 2004 Pearson Education, Inc. All Rights Reserved. Lecture Slides Elementary Statistics Eleventh Edition and the Triola.
DIGITAL SYSTEMS TCE INTERFACING WITH ANALOG DEVICES (Week 12)
Properties of Instrumentation
Olin Student Projects 2008 Keith Gendreau Code 662 NASA/GSFC
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
Multichannel Analyzers A multichannel pulse-height analyzer (MCA) consists of an ADC, a histogramming memory, and a visual display of the histogram recorded.
Multichannel Analyzer (MCA) Raphael Cherney Dan Elg Sam Sun Chen Wang.
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
Gamma Spectroscopy HPT TVAN Technical Training
Spectral contrast enhancement
Ni.com Data Analysis: Time and Frequency Domain. ni.com Typical Data Acquisition System.
Lecture 1 Signals in the Time and Frequency Domains
Understanding ADC Specifications September Definition of Terms 000 Analogue Input Voltage Digital Output Code FS1/2.
Techniques for interference mitigation on RATAN-600 radio telescope in dm ranges A.B. Berlin, N. A. Nizhel'skij, M. G. Mingaliev, P. G. Tsybulev, D. V.

Part 1: Basic Principle of Measurements
Scintillation Detectors
Pulse-Height Analyzers Basic Functions Single Channel Analyzers Time Methods Multi-channel Analyzers.
British Computer Society (BCS)
Pulse Code Modulation PCM is a method of converting an analog signal into a digital signal. (A/D conversion) The amplitude of Analog signal can take any.
Copyright © 2010, 2007, 2004 Pearson Education, Inc. Section 2-2 Frequency Distributions.
MEASUREMENT Of γ-RAY ENERGY SPECTRA BY A SCINTILLATION COUNTER
Section 2-1 Review and Preview. 1. Center: A representative or average value that indicates where the middle of the data set is located. 2. Variation:
Radiation Detection and Measurement, JU, First Semester, (Saed Dababneh). 1 Counting Statistics and Error Prediction Poisson Distribution ( p.
CY1B2 Statistics1 (ii) Poisson distribution The Poisson distribution resembles the binomial distribution if the probability of an accident is very small.
Radiation Detection and Measurement, JU, 1st Semester, (Saed Dababneh). 1 Radioactive decay is a random process. Fluctuations. Characterization.
Acquisitions Systems. Electronic modules and functions Fast Linear Signals for Timing Examples of Systems Assembled Using Modular Electronics.
Radiopharmaceutical Production Radionuclidic identity STOP.
1 Chapter No. 9 Measurements and Detection of Radiation, Nicholas Tsolfanadis, 2010, McGRAW-HILL BOOK INTRODUCTION TO SPECTROSCOPY.
CHAPTER 2.3 PROBABILITY DISTRIBUTIONS. 2.3 GAUSSIAN OR NORMAL ERROR DISTRIBUTION  The Gaussian distribution is an approximation to the binomial distribution.
Signal Analyzers. Introduction In the first 14 chapters we discussed measurement techniques in the time domain, that is, measurement of parameters that.
Chapter No. 18 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Multichannel Pulse Analysis.
The requirements of Ideal pulse-type counter :  1 Every particle entering the detector should produce a pulse at the exit of the counter,
Ambient Feedback Control System Jonathan Uht.  Description of Ambient Feedback Control System  Block Diagram of Ambient Feedback Control System  Hardware.
1 Chapter No. 17 Radiation Detection and Measurements, Glenn T. Knoll, Third edition (2000), John Willey. Measurement of Timing Properties.
 A) Pulse Height Spectroscopy  Identify the equipment such as detector, electronics modules and NIM.
ΨΗΦΙΑΚΟΣ ΕΛΕΓΧΟΣ (22Δ802) Β΄ ΕΞΑΜΗΝΟ Καθηγητής Πέτρος Π. Γρουμπός  Ώρες Γραφείου: Τετάρτη Πέμπτη Παρασκευή 11:00- 12:00 Γραφείο: 1.
Digital Instrumentation Topics Multimeters Digital Multimeters (DMMs) Specifications (Display,Accuracy, Resolution) Meter Applications.
Lecture Notes / PPT UNIT III
 13 Readout Electronics A First Look 28-Jan-2004.
MECH 373 Instrumentation and Measurements
BioTector Diagnostic Download
A First Look J. Pilcher 12-Mar-2004
Introduction to data converters
Lecture 2—Associated Electronics and Energy Spectrum
Introduction to data converters
Measurements of digital signals with spectrum analyzers
Pulse Processing Chapter No. 17
Digital Control Systems Waseem Gulsher
© 2014 John Wiley & Sons, Inc. All rights reserved.
© 2014 John Wiley & Sons, Inc. All rights reserved.
Gamma-Gamma Correlations in Na-22
General Properties of Radiation
Multichannel Pulse Analysis
Multichannel Pulse Analysis
General Properties of Radiation
BESIII EMC electronics
Measurements of digital signals with spectrum analyzers
Chapter No. 10 General description of electronic units used in radiation measurements. viewpoint of ‘ input-output'-i.e., the input and output signals.
Section 2-1 Review and Preview
HE instrument and in-orbit performance
Essentials of Statistics 4th Edition
Presentation transcript:

1 Chapter No. 9 Measurements and Detection of Radiation, Nicholas Tsolfanadis, 2010, McGRAW-HILL BOOK INTRODUCTION TO SPECTROSCOPY

2

3

4

5

6

7

8 9.4 MEASUREMENT OF A DIFFERENTIAL SPECTRUM WITH A SCA  determination of the number of particles within a certain energy interval  E for several values of energy;  Counting the number of pulses within a certain interval  V, for several pulse heights.  Differential spectrum measurement can be counted using SCA operating in the differential mode with the lower threshold of the SCA is set at Vl (or El) and the window has a width  V (or  E), then only pulses with height between Vl and Vl +  V are recorded. All pulses outside this range are rejected.  To measure the pulse spectrum of Fig. 9.6, start by setting the lower threshold at Vl, where Vl > Vo, with a certain window  V (e.g.,  V = 0.1 V) and then keeps lowering the lower threshold of the SCA.  Table 9.2 shows the results of the measurement, where n(V)  V is the number of pulses with height between V and V +  V. Figure 9.8 shows these results. It is assumed that the width is  V = Vi – Vi-1, where Vi, are the successive settings of the lower threshold of the SCA. It is important to note that one never measures the value of n(V), but only the product n(V) AV.

9

10

11

12

13

14

15

16

17

18

19

20

21

22 T9.9 BRIEF DESCRIPTION OF A MULTICHANNEL ANALYZER (MCA) The pulse-height distribution produced by the particles emitted from the source is recorded using a multichannel analyzer (MCA). Multichannel analyzers. Two modes: the pulse-height analysis (PHA) mode or the multichannel scaling (MCS) mode. MCS mode is used to count events as a function of time. The individual channels of the memory count all incoming pulses for a preset time width  t.. After time  t, the counting operation is switched automatically to the next channel in the memory, thus producing in the end a time sequence of the radiation being detected. For example, if the radiation source is a short-lived isotope, the MCS mode will provide the exponential decay curve that can be used for the measurement of the half-life of this isotope. The MCS mode is also useful for Mossbauer experiments. PHA mode is the traditional function of an MCA and is used to sort out incoming pulses according to their height and store the number of pulses of a particular height in a corresponding address of the MCA memory called the channel number. PHA mode, an MCA performs the function of a series of SCAs placed adjacent to one another. When only one SCA with width  E is used, the experimenter has to sweep the spectrum by moving the lower threshold of the SCA manually (see Sec. 9.4). On the other hand, if one had many SCAs, all counting simultaneously, the whole spectrum would be recorded simultaneously

23

24

25 Figure 9.18 shows a simplified block diagram of an MCA. In the PHA mode, the incoming pulse enters into a unit called the analog-to-digital converter (ADC). The ADC digitizes the pulse amplitude: it produces a number proportional to the height of the pulse, a number that determines the channel where the pulse will be stored. The size of the ADC, in channels, defines the absolute resolution of the system. the ADC determines the number of discrete parts into which the pulse height can be subdivided. Commercial ADCs have at the present time a size up to channels, with the full scale adjustable in steps of 256, 512, 1024, etc., channels.The number of discrete parts (channels) into which the input pulse range (0 to + 10 V) is divided is called the conversion gain. The conversion gain is set by a stepwise control knob located on the front of the instrument. As an example, if the conversion gain is set at 2048 channels, it means that the maximum pulse height (10 V) is divided into that many parts. Therefore, the resolution of the MCA at this setting is 10 V/2048 = 4.88 mV/channel The memory of the MCA is a data-storage unit arranged in a series of channels. Every channel is capable of storing up to data (pulses), in most cases. Commercial MCAs have memories with up to channels. Normally, the MCA provides for selection and use of the full memory, only half of it, or one-fourth of it. Transfer of data from one fraction of the memory to another is also possible.

26 Figure 9.17 Measured spectrum for Case In the PHA mode, the first channel of the region used is called channel zero and records, in almost all late model MCAs, the live time of the analysis, in seconds. If the full memory or the first half or first quarter of the memory is used, channel zero is the address If the second half of 4096 memory is used, channel zero is address 2048; if the second quarter is used, channel zero is address 1024; and so on. How does one determine the size of the MCA memory needed for a specific experiment? The decision is made based on the requirements for the PHA mode. One equation frequently used is energy range of interest (keV) where  is the FWHM of the detector used. The factor h is equal to the number of channels at or above the FWHM of the peak. Its value is between 3 and 5.

27 As an example, assume that the energy range of interest is 0 to 2.0 MeV and consider a NaI(T1) and a Ge detector. The resolution of the NaI(T1) detector is about 50 keV. Therefore, the minimum number of channels is (h = 5): The resolution of a Ge detector is about 2 keV. Now, the number of channels is: ADC, not the memory, determines the absolute resolution of an MCA. An MCA with an ADC of 1000 channels and a memory of 2000 channels has an actual resolution of only 1000 channels. In using an MCA to record a spectrum, there is "dead time" involved, which is, essentially, the time it takes to store the pulse in the appropriate channel. That time depends on and increases with the channel number. More details later. MCAs have a meter that shows, during counting, the percentage of dead time. A timers that determine the counting period in live time or clock time. In clock time mode, the counting continues for as long as the clock is set up. In live time mode, an automatic correction for dead time is performed. In this case, the percent dead time indication can be used to determine the approximate amount of actual time the counting will take.

28 For example if the clock is set to count for 5 min (in live mode) and the dead time indicator shows 25 percent, the approximate actual time of this measurement is going to be; Modern MCAs can do much more than just store pulses in memory. They are computers that may, depending on the hardware and software available, be able to 1. Perform the energy calibration of the system 2. Determine the energy of a peak 3. Integrate the area over a desired range of channels 4. Identify an isotope, based on the energy peaks recorded, etc CALIBRATION OF A MULTICHANNEL ANALYZER The calibration of an MCA follows these steps: 1. Determination of range of energies involved. Assume this is 0 I E I Em