OEZ s.r.o. Quick and universal solution for your order Modeion 05/2012.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

New Energy Horizons Opportunities and Challenges Fault Current Contributions from Wind Plants Dean Miller PacifiCorp July 25,
RMM Systems, LLC By Sam Rietta RMM Systems, LLC is a manufacturer's representative firm focused on providing value added sales solutions by providing.
M iniature circuit breakers to UL 489
Circuit Breakers and Busbars. Circuit Breakers Altech’s Circuit Breaker Line UL1077 (R-Series) UL508 (V-EA Series) UL489 (L-Series, AB-Series)
ABB SACE LPD RCDs System pro M compact ®. © ABB SACE RCDs: 3 families RCCB’sRCBO’sBlocks Earth leakage Indirect contact Overload Short circuit.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
Inspection & Test Overview suite412.
Schutzvermerk / Copyright-Vermerk SION Vacuum Circuit-Breaker For Standard Applications Siemens Medium Voltage Sector Energy, Business Unit Medium Voltage.
December, 2010 Vmax – Indoor vacuum circuit-breakers for Primary Distribution Product presentation 1VCP – Rev. D, en – Presentation –
LHC UPS Systems and Configurations: Changes during the LS1 V. Chareyre / EN-EL LHC Beam Operation Committee 11 February 2014 EDMS No /02/2014.
Dry type transformers Zaragoza Traction application
SF6 load-break switch-disconnector
Miniature Circuit Breakers (MCB) Multi 9
Engineer Training Electrical System Overview and Requirements.
Breaker Basics Welcome to this general overview of ABB.
Multi-function apparatus for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
Masterpact LV power air circuit breakers and switch disconnectors
DC Motor Drives Dr. Ahmad Harb.
Welcome DIN Rail product training ISOLATOR/MCB/RCD/RCBO
High Voltage Insulation Diagnostics
EGD ELECTRICAL ELECTRICAL SYMBOLS.
Electro-Pneumatics Module 1
Protection against Electric Shock (Note: All the mentioned tables in this course refer to, unless otherwise specified, Low Voltage Electrical Installation.
Engineer Training XL1200 Electric. Engineer Training XL1200 Electric Confidential 2 Block Diagram.
Electrical Installation 2
Electrical Distribution Training
MNS Sprint - A Market Driven Solution
Vadodara institute of engineering,kotambi NAME:NAFISKHANPATHAN(13ELEE181) BARIYA VIPUL(13ELEE182) PATEL AMIT(13ELEE180) BRANCH:EE-2 PPT OF EEE.
Domestic Wiring Two wires come from the power pole to the house. The ACTIVE wire is 240 V RMS. The NEUTRAL wire is 0 V and is connected to.
Reyrolle LMT Breaker Retrofit BU PPMV – PG Service Marketing and Sales
PowerIT Air Insulated Cubicle Uniswitch
EPack relaunch. Schneider Electric 2 -Industrial – Eurotherm – 16/12/2015 ●1. Reduce your equipment costs.
© 2015 Eaton Corporation. All rights reserved. This is a photographic template – your photograph should fit precisely within this rectangle. Eaton software.
SERVICE ENTRANCE EQUIPMENT
Suggestion on How to Use
1 © 2015 Eaton. All Rights Reserved.. Suggestion on How to Use Industry Trainers are encouraged to use this material in their sessions Download the presentation.
Gates automation. Summary  Choosing the appropriate model  Faac Product Range (Sliding Gates)
HIGH VOLTAGE UNION Vacuum Circuit Breaker 110 kV VRS-110 Series ВЫСОКОВОЛЬТНЫЙ СОЮЗ
R-Series Rotary Disconnects
5SV9 Residual Current Circuit Breakers with Overcurrent Protection
Frei verwendbar / © Siemens AG Alle Rechte vorbehalten.siemens.com/answers 5SU9 Residual Current Circuit Breakers with Overcurrent Protection SENTRON.
5SL4 10 kA / 5SL6 6 kA miniature circuit breakers
Switches and Over Current Protective Devices Class Instructor ALPHER E. DE VERA, uap.
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 MRI4-2 Feeder Relay Sales presentation 2015/08/10.
Single Phase and three Phase Distribution Substation
© 2015 Eaton Corporation. All rights reserved. This is a photographic template – your photograph should fit precisely within this rectangle. Eaton software.
© 2008 Eaton Corporation. All rights reserved. This is a photographic template – your photograph should fit precisely within this rectangle. Electrical.
This is a photographic template – your photograph should fit precisely within this rectangle. © 2016 Eaton. All rights reserved. Eaton software tools xSpider.
ELECTRICAL PLANT DIMENSIONING
A technical proposal for the consolidation of the LHCA cryogenic elec/control system for the HL-LHC era. 07/10/2017 Simon MARTIN Marco PEZZETTI Simon MARTIN.
Measuring device to test completely installed insulated rail joints safely and contactless with direct resistance indication.
3AH5 Vacuum Circuit-Breaker For Standard Applications
INDUCTION MOTOR PROTECTION FOR SINGLE PHASING, OVERVOLTAGE AND OVER TEMPERATURE Submitted by:
LV Safe Powering from UPS to Clients
EE6501 POWER SYSTEM ANALYSIS
3AH5 Vacuum Circuit-Breaker For Standard Applications
Peter Erning, PSP-T11, Power Gen 2010
SION Vacuum Circuit-Breaker For Standard Applications
ELECTRICAL POWER-II Electrical engineering sixth semester
Calculations: Transformers and Service Conductor Calculations
Universal Dim Actuator UD/S
Instructional presentation
3AH5 Vacuum Circuit-Breaker For Standard Applications
Its strengths, your benefits
Its strengths, your benefits
Presentation transcript:

OEZ s.r.o. Quick and universal solution for your order Modeion 05/2012

Quick and universal solution Quick and available support ►Technical support by specialists. ►Proposal of devices according to design ►Training of distributors and customers ►Contact to Your distributor

Quick and universal solution Quick and available support ►Design calculations by Sichr program –short-circuit loops –impedance loops –selectivity –cable rating and optimizing ►Device designing by means of configurator –correct and quick creation of an order ►CAD and CAE support –menu for Autocad –database of OEZ devices

Overcurrent releases ►Basic overcurrent releases –DTV3 for optimal protection of lines and transformers –MTV8 for optimal protection of motors ►regulation of I R = 0.4 ÷ 1 I n (-60 %) ►regulation of short-circuit release current Quick and universal solution

Overcurrent releases ►Additional installation –speeds up switchboard production ►Replacement in operation ►Change of switch-disconnector to circuit breaker and vice versa –lower costs in change of application

Quick and universal solution Connection ►Circuit breaker up to 630 A – BH630 –up to 3x 240 mm 2 per pole ►Circuit breakers BL1000 and BL1600 –up to 4x 300 mm 2 per pole

Quick and universal solution Signalling ►Remote signalling of circuit breaker state ►Remote signalling of switching off by failure –by overcurrent –by short-circuit –design for voltage 60 ÷ 250 V –design for voltage 5 ÷ 60 V with gold- plated contacts

Quick and universal solution Control ►Remote switch-off in 30 ms –Undervoltage release -safety switch-off by the STOP push-button -blocking in standby of power supplies -24 ÷ 400 V a.c./d.c. –Shunt trip for quick switching off -24 ÷ 230 V a.c./d.c.

Control ►Remote switch-on in 70 ms –Motor drive -for standby of power supplies -cycle counter -24 ÷ 230 V a.c./d.c. Quick and universal solution

Basic parameters BC160BD250BH630BL1000BL1600 Rated current 12 ÷ 160 A40 ÷ 250 A100 ÷ 630 A125 ÷1000 A315 ÷ 1600 A Rated voltage 690 V a.c. 250 V d.c. 440 V d.c. 690 V a.c. Dimensions 75 x 135 x 70 mm 105 x 225 x 105 mm 140 x 225 x 105 mm 210 x 350 x 135 mm Number of poles Rated short-circuit ultimate breaking capacity 25 kA36, 65 kA 65 kA Working temperature -55 ÷ +55 °C Overview ►3-pole design

Basic parameters Overview ►4-pole design BC160BD250BH630 Rated current 12 ÷ 160 A40 ÷ 250 A100 ÷ 630 A Rated voltage 690 V a.c. 250 V d.c. 440 V d.c. 690 V a.c. Dimensions 75 x 135 x 70 mm 105 x 225 x 105 mm 140 x 225 x 105 mm Number of poles 333 Rated short-circuit ultimate breaking capacity 25 kA36, 65 kA Working temperature -55 ÷ +55 °C

Accessories Overview ►Plug-in/withdrawable device ►Residual current device ►Auxiliary/signal switch ►Shunt trip/undervoltage release ►Hand drive - front/side ►Motor drive - front/side

Protection Basic overcurrent releases for 80 % applications ►DTV3 –optimal protection of lines and transformers –reduced current control –regulation of short-circuit release current ►MTV8 –optimal protection of motors –complete protection of motors – protection at phase failure –setting according to motor starting class

Protection Special overcurrent releases ►For 4-pole circuit breakers – 4D01 –TN-S and TN-C-S networks ►For time selective protection – MTV9 or U001 –higher selectivity between circuit breakers and fuses

Protection Special overcurrent releases ►Protection of transformers of distribution companies - DTVE –special tripping characteristic for transformers –enables optimal overload of transformers –high selectivity with HV fuses –simple setting according to transformer output –for BD250, BH630, BL1000 –for transformers 50 kVA, 63 kVA, 100 kVA, 160 kVA, 250 kVA, 400 kVA, 630 kVA

Connection Original connecting sets ►All circuit breakers already contain connecting sets BC160 – direct connection of Cu/Al cables of cross-section 2.5 to 95 mm 2 BD250 – connection of Cu/Al busbars or cable lugs up to width of 25 mm BH630 – connection of Cu/Al busbars or cable lugs up to width of 32 mm BL1000 – connection of Cu/Al busbars – front connection BL1600 – connection of Cu/Al busbars – front connection

Connection Connection of more cables per pole.Connection of hollow Cu/Al conductors.Possible degree of protection – IP20.BC160 ►up to 2x (25 ÷ 120) mm 2 ►up to 5x (2.5 ÷ 25) mm 2.BD250 ►up to 2x (25 ÷ 240) mm2 ►up to 6x (6 ÷ 35) mm2.BH630 ►up to 3x (150 ÷ 240) mm 2 ►up to 6x (6 ÷ 35) mm2.BL1000, BL1600 ► up to 4x (70 ÷ 300) mm 2

Hand drive For frequent and convenient control.Locking in off state of the circuit breaker.Red lever with yellow background for the main switch ►Control by the lever directly on the circuit breaker ►Control on the switchboard door –switchboard door opening blocking with the circuit breaker switched on ►Control on the switchboard side –both left and right design

Accessories for special applications Withdrawable and plug-in design ►For BD250, BH630, BL1000 and BL1600 circuit breakers –quick replacement, safe and visible disconnection of the circuit Mechanical interlocking ►For circuit breakers BC160, BD250, BH630, BL1000, BL1600 –for circuit breakers with both hand and remote control –for circuit breaker blocking in standby of power supplies Residual current device ►For BC160 circuit breaker up to 160 A –protection against both direct and indirect contact with live parts

Accessories for special applications Automatic standby unit MODI ►Feeding from two power supplies ►Feeding from two power supplies with longitudinal coupling –control via touch display –signal for start of the generator –switchboard door built-in design –separate wall-mounted switchboard design Delay unit ►For undervoltage releases ►Bridge short-time power supply failures for up to 3 s –circuit breaker with safety STOP button will not switch off in short-time power supply failure

Quality and certification Quality ►StandardsIEC , IEC ►Declaration of Conformity ►CB certificates ►CQS 9001 ►CQS National certification ►ESČ ►GOST – Russia ►UA - Ukraine

Applications Energy sector ►Nuclear power plants –withdrawable and plug-in design ►Coal-burning power plants ►Photovoltaic –remote signalling and control ►Heating plants Distribution of electrical energy ►HV/LV substations ►LV installations –DTVE overcurrent releases ►Main protection of buildings

Applications Industry ►Automotive ►Food ►Metallurgical ►Chemical Infrastructure ►Administration buildings ►Airports, metro ►Shopping centres ►Highways, tunnels

Summary Speed and universality ►Professional technical support ►SW for device and protection design Standard overcurrent releases for 80 % applications ►Optimal protection of lines, transformers and motors ►Additional installation and replacement Wide options for connection of circuit breakers ►Up to 4x 300 mm 2 for circuit breaker BL1000 and BL1600 Remote signalling and control ►Remote signalling of a failure and quick switching off and on Accessories for special applications ►Plug-in and withdrawable devices ►Mechanical interlocking

Modeion moulded case circuit breakers Tel.: Thank you for your attention